1.
Shen CC  Shi TY 《Ultrasonics》2011,51(5):554-560

Background

Ultrasound tissue harmonic signal generally provides superior image quality as compared to the linear signal. However, since the generation of the tissue harmonic signal is based on finite amplitude distortion of the propagating waveform, the penetration and the sensitivity in tissue harmonic imaging are markedly limited because of the low signal-to-noise ratio (SNR).

Methods

The method of third harmonic (3f0) transmit phasing can improve the tissue harmonic SNR by transmitting at both the fundamental (2.25 MHz) and the 3f0 (6.75 MHz) frequencies to achieve mutual enhancement between the frequency-sum and the frequency-difference components of the second harmonic signal. To further increase the SNR without excessive transmit pressure, coded excitation can be incorporated in 3f0 transmit phasing to boost the tissue harmonic generation.

Results

Our analyses indicate that the phase-encoded Golay excitation is suitable in 3f0 transmit phasing due to its superior transmit bandwidth efficiency. The resultant frequency-sum and frequency-difference components of tissue harmonic signal can be simultaneously Golay-encoded for SNR improvement. The increase of the main-lobe signal with the Golay excitation in 3f0 transmit phasing are consistent between the tissue harmonic measurements and the simulations. B-mode images of the speckle generating phantom also demonstrate the increases of tissue harmonic SNR for about 11 dB without noticeable compression artifacts.

Conclusion

For tissue harmonic imaging in combination with the 3f0 transmit phasing method, the Golay excitation can provide further SNR improvement. Meanwhile, the axial resolution can be effectively restored by pulse compression while the lateral resolution remains unchanged.  相似文献   

2.

Purpose

A direct correlation between T, T2 and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T and T2 values in human osteoarthritic cartilage and to quantify the correlation between T, T2 vs. biochemical composition and histology in human osteoarthritic cartilage.

Materials and methods

Thirty-three cartilage specimens were collected from patients who underwent total knee arthroplasty due to severe osteoarthritis and scanned with a 3T MR scanner for T and T2 quantification. Nine specimens were scanned at three different orientations with respect to the B0: 0°, 90° and 54.7°. Core punches were taken after MRI. Collagen and proteoglycan contents were quantified using biochemical assays. Histology sections were graded using Mankin scores. The correlation between imaging parameters, biochemical contents and histological scores were studied.

Results

Both mean T and T2 at 54.7° were significantly higher than those measured at 90° and 0°, with T showing less increase compared to T2. R (1/T) values had a significant but moderate correlation with proteoglycan contents (R=.45, P=.002), while R2 (1/T2) was not correlated with proteoglycan. No significant correlation was found between relaxation times (T or T2) and collagen contents. The T values of specimen sections with high Mankin scores were significantly higher than those with low Mankin scores (P<.05).

Conclusions

Quantitative MRI has a great potential to provide noninvasive imaging biomarkers for cartilage degeneration in osteoarthritis.  相似文献   

3.

Purpose

The purpose of the study was to investigate the relationship between gas challenge-blood oxygen level-dependent (GC-BOLD) response angiogenesis and tumor size in rat Novikoff hepatoma model.

Materials and Methods

Twenty adult male Sprague-Dawley rats (weighting 301-325 g) were used for our Animal Care and Use Committee-approved experiments. N1-S1 Novikoff hepatomas were grown in 14 rats with sizes ranging from 0.42 to 2.81 cm. All experiments were performed at 3.0 T using a custom-built rodent receiver coil. A multiple gradient-echo sequence was used for R2? measurements, first during room air (78% N2/20% O2) breathing and then after 10 min of carbogen (95% O2/5% CO2) breathing. After image acquisition, rats were euthanized, and the tumors were harvested for histological evaluation.

Results

The R2? change between air and carbogen breathing for small hepatomas was positive; R2? changes changed to negative values for larger hepatomas. We found a significant positive correlation between tumor R2? change and tumor microvessel density (MVD) (r=0.798, P=.001) and a significant inverse correlation between tumor R2? change and tumor size (r=−0.840, P<.0001).

Conclusions

GC-BOLD magnetic resonance imaging measurements are well correlated to MVD levels and tumor size in the N1-S1 Novikoff hepatoma model; GC-BOLD measurements may serve as noninvasive biomarkers for evaluating angiogenesis and disease progression and/or therapy response.  相似文献   

4.

Purpose

Magnetic resonance images of biological media based on chemical exchange saturation transfer (CEST) show contrast that depends on chemical exchange between water and other protons. In addition, spin–lattice relaxation rates in the rotating frame (R1ρ) are also affected by exchange, especially at high fields, and can be exploited to provide novel, exchange-dependent contrast. Here, we evaluate and compare the factors that modulate the exchange contrast for these methods using simulations and experiments on simple, biologically relevant samples.

Methods

Simulations and experimental measurements at 9.4 T of rotating frame relaxation rate dispersion and CEST contrast were performed on solutions of macromolecules containing amide and hydroxyl exchanging protons.

Results

The simulations and experimental measurements confirm that both CEST and R1ρ measurements depend on similar exchange parameters, but they manifest themselves differently in their effects on contrast. CEST contrast may be larger in the slow and intermediate exchange regimes for protons with large resonant frequency offsets (e.g. > 2 ppm). Spin-locking techniques can produce larger contrast enhancement when resonant frequency offsets are small (< 2 ppm) and exchange is in the intermediate-to-fast regime. The image contrasts scale differently with field strength, exchange rate and concentration.

Conclusion

CEST and R1ρ measurements provide different and somewhat complementary information about exchange in tissues. Whereas CEST can depict exchange of protons with specific chemical shifts, appropriate R1ρ-dependent acquisitions can be employed to selectively portray protons of specific exchange rates.  相似文献   

5.

Objective

The objective of this study was to develop quantitative T-weighted magnetic resonance imaging methodology for the detection and characterization of cartilage degeneration in a rabbit anterior cruciate ligament (ACL) transection model.

Methods

The right knee ACLs of 18 adult female New Zealand white rabbits were transected. The left knee joint served as a sham control. The rabbits were euthanized at 3 (Group 1), 6 (Group 2) and 12 (Group 3) weeks postoperatively. High-resolution 3D fat-saturated spoiled gradient echo images and T-weighted images were obtained in both the sagittal and axial planes at 3 T using a quadrature wrist coil. Following MR analysis, histological slides from the lateral femoral condyle cartilage were graded using the Mankin grading system.

Results

For all three groups, the average overall T values were significantly higher in the ACL-transected knee compared to control knee, and the percentage differences in T values between ACL-transected and control increased with the duration of time after transection. The average Mankin score for ACL-transected knees was higher than that for control for each time point, but this difference was statistically significant only for all groups combined.

Conclusions

This study demonstrates the feasibility of using T-weighted imaging as a useful tool in the detection and quantification of cartilage damage in all knee compartments in an ACL-transected rabbit model of cartilage degeneration.  相似文献   

6.
Localized Yb 4f and itinerant Rh 4d states are subject to substantial hybridization effects in the heavy-fermion material YbRh2Si2. The proximity to the Fermi level and the high anisotropy in k space naturally raise questions regarding the role of these hybridization effects for the observed, unusual physical properties. Using angle-resolved photoemission spectroscopy (ARPES) we found that the non-dispersive behavior of the localized Yb f states is broken around the Γ point due to interaction with approaching Rh 4d bands. The intriguing point here is that the hybridization strength turns out to be systematically tunable by electron doping of the material. Gradual deposition of silver atoms onto the atomically clean, silicon terminated surface of YbRh2Si2 leads to transfer of Ag 5s charge into the Rh 4d bands. This substantially changes the energy overlap, and thus the hybridization strength, between the interacting Yb 4f and Rh 4d bands in the surface and subsurface region. The shown possibility to control the variation of the f-d hybridization at the surface of heavy-fermion materials may also be helpful for other ARPES studies on the diverse phenomena in electron-correlated materials.  相似文献   

7.

Purpose

The regional uptake of glucose in rat brain in vivo was measured at high resolution using spin-lock magnetic resonance imaging after infusion of the glucose analogue 2-deoxy-d-glucose (2DG). Previous studies of glucose metabolism have used 13C-labeled 2DG and NMR spectroscopy, 18F-labeled fluorodeoxyglucose (FDG) and PET, or chemical exchange saturation transfer (CEST) MRI, all of which have practical limitations. Our goal was to explore the ability of spin-lock sequences to detect specific chemically-exchanging species in vivo and to compare the effects of 2DG in brain tissue on CEST images.

Methods

Numerical simulations of R1p and CEST contrasts for a variety of sample parameters were performed to evaluate the potential specificity of each method for detecting the exchange contributions of 2DG. Experimental measurements were made in tissue phantoms and in rat brain in vivo which demonstrated the ability of spin-lock sequences for detecting 2DG.

Results

R1p contrast acquired with appropriate spin-lock sequences can isolate the contribution of exchanging protons in 2DG in vivo and appears to have better sensitivity and more specificity to 2DG–water exchange effects than CEST.

Conclusion

Spin-lock imaging provides a novel approach to the detection and measurement of glucose uptake in brain in vivo.  相似文献   

8.
This investigation experimentally studies the low-frequency alternating-current magnetic susceptibility (χac) of amorphous and nanocrystalline CoFeB films by measuring the magnetic field established by passing currents of various frequencies through such films of various thicknesses (tf). A CoFeB film is sputtered onto a glass substrate with tf from 100 Å to 500 Å under the following conditions: (a) As-deposited films were maintained at room temperature (RT) and (b) films were post-annealed at TA=150 °C for 1 h. The samples thus obtained are analyzed in a magnetic field that was generated by an alternating current (AC) at various frequencies from 10 Hz to 25,000 Hz. The experimental results demonstrate that the χac declines as the thickness of the as-deposited sample and the post-annealed sample (TA=150 °C) increases because the lower coercivity (Hc) of thinner CoFeB films is similar to a soft magnetic characteristic and is associated with a higher χac value. The best χac value is obtained at a thickness of 100 Å under both conditions. The χac value of the post-annealed sample exceeds that of the RT sample at thicknesses from 100 Å to 500 Å because the magneto crystalline anisotropy of the post-annealed sample yields the highest χac value at the optimal resonance frequency (fres), at which the spin sensitivity is maximal. The X-ray diffraction patterns (XRD) of as-deposited CoFeB films reveal their amorphous structure. The XRD results for the post-annealed films include a main peak at 2θ=44.7° from the body-centered cubic (BCC) nanocrystalline CoFe that indicated a (110) textured structure. Post-annealing treatment caused that the amorphous structure to become more crystalline by a thermally driven process, such that the χac value of the post-annealed sample exceeded that of the RT sample. This experimental result demonstrates that the χac value decreased as the thickness of the thin film increased. Finally, the CoFeB thin films had the best χac at low frequency (<50 Hz) following post-annealing treatment. The results obtained under the two conditions indicate that the maximum χac value and the optimal fres of a 100 Å-thick CoFeB thin film were 1.6 and 30 Hz, respectively, following post-annealing at TA=150 °C for 1 h, suggesting that a 100 Å-thick CoFeB thin film that has been post-annealed at TA=150 °C can be utilized as a gage sensor and in transformer applications at low frequencies.  相似文献   

9.
The Zn1−xMgxO thin films were grown on Al2O3 substrate with various O2 flow rates by plasma-assisted molecular beam epitaxy (P-MBE). The growth conditions were optimized by the characterizations of morphology, structural and optical properties. The Mg content of the Zn1−xMgxO thin film increases monotonously with decreasing the oxygen flux. X-ray diffractometer (XRD) measurements show that all the thin films are preferred (0 0 2) orientated. By transmittance and absorption measurements, it was found that the band gap of the film decreases gradually with increasing oxygen flow rate. The surface morphology dependent on the oxygen flow rate was also studied by field emission scanning electron microscopy (FE-SEM). The surface roughness became significant with increasing oxygen flow rate, and the nanostructures were formed at the larger flow rate. The relationship between the morphology and the oxygen flow rate of Zn1−xMgxO films was discussed.  相似文献   

10.

Objective

T2 mapping has been used widely in detecting cartilage degeneration in osteoarthritis. Several scanning sequences have been developed in the determination of T2 relaxation times of tissues. However, the derivation of these times may vary from sequence to sequence. This study seeks to evaluate the sequence-dependent differences in T2 quantitation of cartilage, muscle, fat and bone marrow in the knee joint at 3 T.

Methods

Three commercial phantoms and 10 healthy volunteers were studied using 3 T MR. T2 relaxation times of the phantoms, cartilage, muscle, subcutaneous fat and marrow were derived using spin echo (SE), multiecho SE (MESE), fast SE (FSE) with varying echo train length (ETL), spiral and spoiler gradient (SPGR) sequences. The differences between these times were then evaluated using Student's t test. In addition, the signal-to-noise ratio (SNR) efficiency and coefficient of variation of T2 from each sequence were calculated.

Results

The average T2 relaxation time was 36.38±5.76 ms in cartilage and 34.08±6.55 ms in muscle, ranging from 27 to 45 ms in both tissues. The times for subcutaneous fat and marrow were longer and more varying, ranging from 41 to 143 ms and from 42 to 160 ms, respectively. In FSE acquisition, relaxation time significantly increases as ETL increases (P<.05). In cartilage, the SE acquisition yields the lowest T2 values (27.52±3.10 ms), which is significantly lower than those obtained from other sequences (P<.002). T2 values obtained from spiral acquisition (38.27±6.45 ms) were higher than those obtained from MESE (34.35±5.62 ms) and SPGR acquisition (31.64±4.53 ms). These differences, however, were not significant (P>.05).

Conclusion

T2 quantification can be a valuable tool for the diagnosis of degenerative disease. Several different sequences exist to quantify the relaxation times of tissues. Sequences range in scan time, SNR efficiency, reproducibility and two- or three-dimensional mapping. However, when choosing a sequence for quantitation, it is important to realize that several factors affect the measured T2 relaxation time.  相似文献   

11.

Background

Permanent prostate brachytherapy (PPB) is a common treatment for early stage prostate cancer. While the modern approach using trans-rectal ultrasound guidance has demonstrated excellent outcome, the efficacy of PPB depends on achieving complete radiation dose coverage of the prostate by obtaining a proper radiation source (seed) distribution. Currently, brachytherapy seed placement is guided by trans-rectal ultrasound imaging and fluoroscopy. A significant percentage of seeds are not detected by trans-rectal ultrasound because certain seed orientations are invisible making accurate intra-operative feedback of radiation dosimetry very difficult, if not impossible. Therefore, intra-operative correction of suboptimal seed distributions cannot easily be done with current methods. Vibro-acoustography (VA) is an imaging modality that is capable of imaging solids at any orientation, and the resulting images are speckle free.

Objective and methods

The purpose of this study is to compare the capabilities of VA and pulse-echo ultrasound in imaging PPB seeds at various angles and show the sensitivity of detection to seed orientation. In the VA experiment, two intersecting ultrasound beams driven at f1 = 3.00 MHz and f2 = 3.020 MHz respectively were focused on the seeds attached to a latex membrane while the amplitude of the acoustic emission produced at the difference frequency 20 kHz was detected by a low frequency hydrophone.

Results

Finite element simulations and results of experiments conducted under well-controlled conditions in a water tank on a series of seeds indicate that the seeds can be detected at any orientation with VA, whereas pulse-echo ultrasound is very sensitive to the seed orientation.

Conclusion

It is concluded that vibro-acoustography is superior to pulse-echo ultrasound for detection of PPB seeds.  相似文献   

12.
Shen CC  Su SY  Cheng CH  Yeh CK 《Ultrasonics》2012,52(1):25-32

Objective

The goal of this work is to examine the effects of pulse-inversion (PI) technique in combination with dual-frequency (DF) excitation method to separate the high-order nonlinear responses from microbubble contrast agents for improvement of image contrast. DF excitation method has been previously developed to induce the low-frequency ultrasound nonlinear responses from bubbles by using the composition of two high-frequency sinusoids (f1 and f2).

Motivation

Although the simple filtering was conventionally utilized to provide signal separation, the PI approach is better in the sense that it minimizes the mutual interferences among these high-order nonlinear responses in the presence of spectral overlap. The novelty of the work is that, in addition to the common PI summation, the PI subtraction was also applied in DF excitation method.

Methods

DF excitation pulses having an envelope frequency of 3 MHz (i.e., f1 = 8.5 MHz and f2 = 11.5 MHz) with pulse lengths of 3-10 μs and the pressure amplitudes from 0.5 to 1.5 MPa were used to interrogate the nonlinear responses of SonoVue™ microbubbles in the phantom experiments. The high-order nonlinear responses in the DF excitation were extracted for contrast imaging using PI summation for even-order nonlinear components or PI subtraction for odd-order nonlinear ones.

Results

Our results indicated that, as compared to the conventional filtering technique, the PI processing effectively increases the contrast-to-tissue ratio (CTR) of the third-order nonlinear response at 5.5 MHz and the fourth-order nonlinear response at 6 MHz by 2-5 dB. For these high-order nonlinear components, the CTR increase varies with the transmission pressures from 0.5 to 1.5 MPa due to the microbubbles’ displacement induced by the radiation force of DF excitation.

Conclusions

For DF excitation technique, the PI processing can help to extract either the odd-order or the even-order nonlinear components for higher CTR estimates.  相似文献   

13.
Blue phosphors Ca1 − xAl2O4: xEu2+ were prepared by high temperature solid-state method. Their structure, morphology and luminescent properties were investigated by X-ray diffraction (XRD), scanning electron microscope (SEM) and fluorescence spectroscopy. The effect of different amounts of fluxing agent H3BO3 on structure, morphology and luminescent properties of blue phosphors Ca1 − xAl2O4: xEu2+ luminous intensity caused by different amount of H3BO3 was also investigated. The amount of H3BO3 doped Ca1 − xAl2O4: xEu2+ in optimal luminous intensity had been determined. The results showed that both the excitation and emission spectra of samples were all broad bands, and that the peak of emission spectra was near 442 nm, which was corresponding to the 4f65d → 4f7 transition of Eu2+ illuminating blue light. Ca1 − xAl2O4: xEu2+ (x = 3.5 mol%) could be gained with good morphology and the best luminous intensity when H3BO3 mass ratio was 0.5 wt%.  相似文献   

14.
Ca0.54Sr0.34−1.5xEu0.08Smx(MoO4)y (WO4)1−y red phosphors were prepared by solid-state reaction using Na+ as a charge compensator for light-emitting diodes (LED). The effects of Na+ concentration, synthesis temperature, reaction time and Eu3+ concentration were studied for the properties of luminescence and crystal structure of red phosphors. The results show that the optimum reaction condition is 6%, 900 °C, 2 h and 8%. The photoluminescence spectra show that red phosphors are effectively excited at 616 nm by 292, 395 and 465 nm. The wavelengths of 465 nm nicely match the widely applied emission wavelengths of blue LED chips.  相似文献   

15.

Purpose

To assess the performance and results of R2 relaxometry using a fat-suppressed (FS) multiecho sequence and compare these to conventional R2 relaxometry in estimating tissue iron overload.

Materials and Methods

Relaxation rate values (R2=1/T2) of the liver, spleen, pancreas and vertebral bone marrow (VBM) were estimated in 21 patients with β-thalassemia major, using a respiratory-triggered 16-echo Carr-Purcell-Meiboom-Gill (CPMG) spin-echo sequence before (R2) and after (R2 FS) the application of chemically selective fat suppression.

Results

Hepatic and splenic R2 FS values correlated with respective R2 values (r=0.98 and r=0.96, P<.001), whereas correlations between R2 FS and R2 values for pancreas and VBM were not statistically significant. Bland–Altman plots show disagreement between R2 and R2 FS values, particularly for pancreas and VBM. Hepatic, pancreatic and VBM R2 FS values correlated with serum ferritin (r=0.88, P<.001; r=0.51, P<.003; and r=0.75, P<.002, respectively). Hepatic R2 FS values correlated with splenic R2 FS (r=0.77, P<.03), pancreatic R2 FS (r=0.61, P<.006) and VBM R2 FS values (r=0.70, P<.001), whereas pancreatic R2 FS values correlated also with VMB R2 FS values. On the contrary, among the R2 values of the above tissues, obtained without fat suppression, only hepatic R2 values correlated with serum ferritin, whereas no correlation was documented between hepatic and pancreatic or VBM R2 values. The application of fat suppression did not improve breathing or flow artifacts.

Conclusion

Application of fat suppression in the standard CPMG sequence improved the capability of MRI in noninvasive quantification of iron, particularly in lipid-rich tissues, such as vertebral bone marrow (VBM) and pancreas.  相似文献   

16.
An optical study of a Y0.99Pr0.01PO4 single crystal is presented. Measurements of optical absorption, excitation, and emission by selective excitation into 1D2, 3P0 and 3P1, at different temperatures between 20 and 295 K, are described. A detailed account of the line assignments is given for absorption in the 4300-23 000 cm−1 spectral range, and for emission in the 6400-23 000 cm−1 range. The lifetimes of the emitting levels are determined. Vibronic sidebands accompanying absorption, emission and excitation spectra are reported. The decay processes of the 3P1, 3P0 and 1D2 levels are discussed. The aim of this study is a test of the configuration-interaction-assisted crystal field analysis as well as the accurate experimental determination of the energy level scheme. It was reported previously that the introduction of configuration interaction between the ground 4f2 configuration with the excited 4f6p configuration always resulted in a decrease (≈50-60%) in the standard deviations between the observed and calculated energy levels. In the present work the 4f5d configuration is included as well. The crystal field is analysed in the theoretical D2d site symmetry with and without configuration interaction. The results with 4f2, 4f2+4f5d, 4f2+4f6p and 4f2+4f5d+4f6p are given. The calculation on the basis of the 315 (4f2+4f5d+4f6p) levels gives the best overall standard deviation lowering it by 75% with regard to the calculation on the 91 4f2 levels only.  相似文献   

17.

Objectives

To test the effect of pulsed (Q-switched) and continuous wave (CW) laser light at wavelength of 532 nm on the viability of free-living stationary phase bacteria with and without gentamicin (an antibiotic) treatment.

Methods

Free living stationary phase gram negative bacteria (Pseudomonas aeruginosa strain PAO1) was immersed in Luria Broth (LB) solution and exposed to Q-switched and CW lasers with and without the addition of the antibiotic gentamicin. Cell viability was determined at different time points.

Results

Laser treatment alone did not reduce cell viability compared to untreated control and the gentamicin treatment alone only resulted in a 0.5 log reduction in the viable count for P. aeruginosa. The combined laser and gentamicin treatment, however, resulted in a synergistic effect and viability was reduced by 8 logs for P. aeruginosa PAO1.

Conclusions

Combination of laser light with gentamicin shows an improved efficacy against P. aeruginosa.  相似文献   

18.
Mitri FG  Fellah ZE 《Ultrasonics》2011,51(5):523-526

Background and motivation

Previous works investigating the radiation force of diverging spherical progressive waves incident upon spherical particles have demonstrated the direction of reversal of the force when the particle is subjected to a curved wave-front. In this communication, the analysis is extended to the case of diverging cylindrical progressive waves incident upon a rigid or a soft cylinder in a non-viscous fluid with explicit calculations for the radiation force function (which is the radiation force per unit energy density and unit cross-sectional surface) not shown in [F.G. Mitri, Ultrasonics 50 (2010) 620-627].

Method

A closed-form solution presented previously in [F.G. Mitri, Ultrasonics 50 (2010) 620-627] is used to plot the radiation force function with particular emphasis on the difference from the results of incident plane progressive waves versus the size parameter ka (k is the wave number and a is the cylinder’s radius) and the distance of the cylinder from the acoustic source r0.

Results

Radiation force function calculations for the rigid cylinder unexpectedly reveal that under specific conditions determined by the frequency of the acoustic field, the radius of the cylinder, as well as the distance to the acoustic source, the force becomes attractive (negative force). In addition, the numerical results show that the radiation force on a rigid cylinder does not generally obey the inverse-distance law with respect to the distance from the source.

Conclusion and potential applications

These results suggest that it may be possible, under specific conditions, to pull a cylindrical structure back toward the acoustic source using progressive cylindrical diverging waves. They may also provide a means to predict the radiation force required to manipulate non-destructively a single cylindrical structure. Potential applications include the design of a new generation of acoustic tweezers operating using a single beam of progressive waves (in contrast to the traditional version of acoustical tweezers in which an acoustic standing wave field is produced using two counter-propagating acoustic fields) for investigations in the field of flow cytometry, particle manipulation and entrapment.  相似文献   

19.
In this study, nano-scale precursors of ZnO, SiO2, and MnO2 powders were used to prepare mixtures with the compositions of 2ZnO+SiO2+X mol% MnO2 (X=MnO2/2ZnO, abbreviated as Zn2SiO4-X-MnO2), where 2≤X≤5. The mixed Zn2SiO4-X-MnO2 mixtures were calcined from 900 to 1300 °C in air in order to synthesize Zn2SiO4:Mn2+ green phosphors. The X-ray diffraction patterns of Zn2SiO4-X-MnO2 particles indicated that ZnO was present in the 900 °C-calcined Zn2SiO4-X-MnO2 phosphors, but not in particles calcined at temperatures of 1000 °C and higher. However, the unapparent secondary phase of ZnMnO3 was found in the 1200 and 1300 °C-calcined Zn2SiO4-5-MnO2 compositions. The luminescent characteristics of Zn2SiO4-X-Mn2+ phosphors were compared with that of a commercial product (Nichia Corp., Japan). The photoluminescence (PL) intensity of 1200 °C-calcined Zn2SiO4-4-MnO2 phosphors was higher and the decay times of all synthesized Zn2SiO4-X-MnO2 phosphors were longer than those of the commercial product.  相似文献   

20.
Rare-earth oxide films for gate dielectric on n-GaAs have been investigated. The oxide films were e-beam evaporated on S-passivated GaAs, considering interfacial chemical bonding state and energy band structure. Rare-earth oxides such as Gd2O3, (GdxLa1−x)2O3, and Gd-silicate were employed due to high resistivity and no chemical reaction with GaAs. Structural and bonding properties were characterized by X-ray photoemission, absorption, and diffraction. The electrical characteristics of metal-oxide-semiconductor (MOS) diodes were correlated with material properties and energy band structures to guarantee the feasibility for MOS field effect transistor (FET) application.Gd2O3 films were grown epitaxially on S-passivated GaAs (0 0 1) at 400 °C. The passivation induced a lowering of crystallization temperature with an epitaxial relationship of Gd2O3 (4 4 0) and GaAs (0 0 1). A better lattice matching relation between Gd2O3 and GaAs substrate was accomplished by the substitution of Gd with La, which has larger ionic radius. The in-plane relationship of (GdxLa1−x)2O3 (4 4 0) with GaAs (0 0 1) was found and the epitaxial films showed an improved crystalline quality. Amorphous Gd-silicate film was synthesized by the incorporation of SiO2 into Gd2O3. These amorphous Gd-silicate films excluded defect traps or current flow path due to grain boundaries and showed a relatively larger energy band gap dependent on the contents of SiO2. Energy band parameters such as ΔEC, ΔEV, and Eg were effectively controlled by the film composition.  相似文献   