首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
For the requirement of a high, fast and sufficient technology to suit the needs of 21st century biotechnology, the separation range of a microchip electrophoresis system was studied. Two DNA fragments on the human Y-chromosome, SY594 (82 bp) and 12f2 (88 bp), were successfully separated with a reproducibility of 1.9% and an accuracy of 2.8%. Then, a mixture of 10 DNA markers ranging from 61 bp to 189 bp was successfully separated with high resolution. All of these results demonstrate the superiority of microchip electrophoresis as a tool for 21st century bioseparation.  相似文献   

2.
For the diagnosis of unexplained male infertility a multiplex PCR for 6 markers, which are well-known as candidate genes for studying male infertility and located on the human Y-chromosome, has been designed. The multiplex PCR products have been separated on a 12 channel microchip electrophoresis system, which can analyze different samples simultaneously. By combining the technologies of multiplex PCR with multichannel microchip electrophoresis, the number of the DNA markers that can be screened simultaneously is increased to be 72 marker (12 x 6) in a single run while the electrophoresis analysis time is reduced to be only 180 s.  相似文献   

3.
Microfabrication technology was used to develop a system consisting of disposable glass chips containing etched channels, reagents including polymer matrix and size standards, computer-controlled instrumentation for performing electrophoretic separations and fluorescence detection of double-stranded DNA, and software for automated data analysis. System performance was validated for separation and quantitation reproducibility using samples varying in amount and size of DNA fragments, buffer composition, and salt concentrations. Several applications of the microfluidic system for DNA analysis have been demonstrated, such as of polymerase chain reaction (PCR) products, sizing of plasmid digests, and detection of point mutations by restriction fragment length polymorphism (RFLP) mapping.  相似文献   

4.
We have investigated the accuracy and reproducibility of DNA quantitation on the DNA Lab-Chip and the relationship of these to the size and concentration of the DNA fragments. We found that quantitation of small DNA fragments, i.e. less than 200 bp, suffers from high relative error which can be improved by using an internal standard of similar size to the sample. The effects of trace chloride ion on quantitation error and sensitivity of the DNA Lab-Chip were also studied, and it was revealed that 0.2 mM chloride ion reduces quantitation sensitivity by 30% and increases the relative error. We also studied the effects of purification on quantitation errors in analysis of PCR products from cloning vector pUC118 and showed that use of an unpurified sample reduces chip sensitivity by 25%.Dedicated to Professor K. Jinno on the occasion of his 60th birthday.Revised: 9 December 2004 and 17 January 2005  相似文献   

5.
Ginseng is one of the most expensive Chinese herbal medicines and the effectiveness of ginseng depends strongly on its botanical sources and the use of different parts of the plants. In this study, a microchip electrophoresis method coupled with the polymerase chain reaction (PCR)–short tandem repeats (STR) technique was developed for rapid authentication of ginseng species. A low viscosity hydroxypropyl methylcellulose (HPMC) solution was used as the sieving matrix for separation of the amplified STR fragments. The allele sizing of the amplified PCR products could be detected within 240 s or less. Good reproducibility and accuracy of the fragment size were obtained with the relative standard deviation for the allele sizes less than 1.0% (n=11). At two microsatellite loci (CT 12, CA 33), American ginseng had a different allele pattern on the electropherograms compared with that of the Oriental ginseng. Moreover, cultivated and wild American ginseng can be distinguished on the basis of allele sizing. This work establishes the feasibility of fast genetic authentication of ginseng species by use of microchip electrophoresis.  相似文献   

6.
Zhang L  Dang F  Baba Y 《Electrophoresis》2002,23(14):2341-2346
The stepwise gradient of linear polymer matrices in microchannel electrophoresis is proposed as a means of achieving high-resolution separation of DNA samples containing a wide range of fragment sizes. In this method, multiple discrete steps in terms of polymer type or concentration are created in the microchannel by injecting appropriate solutions in order. The mixing of the various steps is found to be negligible compared to the effective length of separation channel, confirming that a stepwise gradient of matrices is formed. This technique is successfully applied to the analysis of restriction digest fragments and DNA ladders, and is demonstrated to provide higher resolution than the isocratic method, for both small and large fragments simultaneously. Even though the stepwise gradient is created manually, the reproducibility of the migration times of fragments in DNA samples is found to be quite good. Taken the separation of 100 bp DNA ladder in three steps gradient pattern as an example, the relative standard deviations of migration times are respectively less than 0.53% and 3.1% in six consecutive injections in one channel and in different channels. The migration of DNA fragments in gradient mode is shown to be similar to that for the isocratic scheme, allowing the design of each step to be made in reference to existing knowledge. These promising results indicate the great potential of this stepwise gradient method for the analysis of DNA by microchip electrophoresis, offering both high resolution and good reproducibility.  相似文献   

7.
We describe the use of denaturing gradient gel electrophoresis to screen for DNA sequence polymorphisms in the human factor VIII gene. DNA fragments that differ in sequence by only a single base pair can be separated on denaturing gradient gels due to changes in their melting behavior. Previous studies have demonstrated the use of denaturing gradient gels to detect sequence changes in human genomic DNA, including mutations in the beta globin gene and polymorphisms on chromosome 20. We have begun to use denaturing gradient gels to look for polymorphisms within the human factor VIII gene. The DNA sequences of seven cloned fragments from introns in the human factor VIII gene were determined and used to predict a melting map for each fragment. The melting behavior of each cloned fragment was evaluated by electrophoresis into denaturing gradient gels. Appropriate fragments were then used as radioactive probes for hybridization to human DNA samples that had been digested with restriction enzymes. Heteroduplexes formed between the probe and genomic DNA samples were electrophoresed into denaturing gradient gels. The final positions of heteroduplex bands were determined by autoradiography. We describe a general approach for using denaturing gradient gel electrophoresis to find DNA polymorphisms, with particular emphasis on the predictive value of DNA sequence data. We compare the efficiency of polymorphism detection by denaturing gradient gel electrophoresis with detection by restriction fragment length polymorphism (RFLP) analysis. The factor VIII gene appears to have a low level of DNA sequence polymorphism.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
微流控芯片技术因具有微量、快速、高效和高通量等特点,已成为分析化学领域中的研究热点之一.在微流控芯片中,最常见的可用作芯片的材料为玻璃、石英和各种塑料.玻璃和石英有很好的电渗性和光学性质,可采用标准的刻蚀工艺加工和用化学方法进行表面改性,但加工成本较高,封接难度较大.  相似文献   

9.
Inexpensive and permanently modified poly(methyl methacrylate)(PMMA) microchips were fabricated by an injection-molding process. A novel sealing method for plastic microchips at room temperature was introduced. Run-to-run and chip-to-chip reproducibility was good, with relative standard deviation values between 1-3% for the run-to-run and less than 2.1% for the chip-to-chip comparisons. Acrylonitrile-butadiene-styrene (ABS) was used as an additive in PMMA substrates. The proportions of PMMA and ABS were optimized. ABS may be considered as a modifier, which obviously improved some characteristics of the microchip, such as the hydrophilicity and the electro-osmotic flow (EOF). The detection limit of Rhodamine 6G dye for the modified microchip on the home-made microchip analyzer showed a dramatic 100-fold improvement over that for the unmodified PMMA chip. A detection limit of the order of 10(-20) mole has been achieved for each injected psiX-174/HaeIII DNA fragment with the baseline separation between 271 and 281 bp, and fast separation of 11 DNA restriction fragments within 180 seconds. Analysis of a PCR product from the tobacco ACT gene was performed on the modified microchip as an application example.  相似文献   

10.
In this paper we report on simultaneous genotyping of adjacent polymorphisms (referred to as haplotyping) by combining double-tube allele-specific polymerase chain reaction, restriction fragment length polymorphism and capillary gel electrophoresis analysis of the resulting fragments. Direct molecular haplotyping is of particular importance in the case of double heterozygote samples, since in these instances the haplotype structure cannot be constructed based on genotype data. Our approach provided a powerful tool for coincidental genotype analysis of the 48 base pair (bp) variable number of tandem repeats of the third exon and haplotype investigation of the -616CG and -521CT single nucleotide polymorphisms of the dopamine D4 receptor (DRD4) gene. The linear polyacrylamide sieving matrix was optimized for the size range of the double-stranded DNA fragments of interest varying from 35 to 763 bp. We demonstrated that capillary gel electrophoresis in combination with laser induced fluorescence detection offers a sensitive and accurate tool for automated haplotyping in clinical settings.  相似文献   

11.
This study evaluated the applicability of microchip electrophoresis to the sizing of microsatellites suitable to genetic, clinical and forensic applications. The evaluation was performed with the D19S394 tetranucleotide (AAAG) repeat characterized by a wide variation in the repeat number (1-17) and a short recombination distance from the low-density lipoprotein (LDL)-receptor gene that makes it suitable to cosegregation analysis of familial hypercholesterolemia (FH). The study was performed with 70 carriers of two LDL-receptor mutations common in northern Italy (i.e., the 4 bp insertion in exon 10 known as FH-Savona and the D200G missense mutation in the exon 4, known as FH-Padova 1) and 100 healthy controls. The polymerase chain reaction (PCR) amplification products prepared with a cosolvent PCR protocol and an antibody-protected polymerase were directly analyzed with an apparatus for high-voltage capillary electrophoresis on microchips and laser-induced fluorescence detection equipped with chips for the analysis of 25-500 bp dsDNA fragments. The test could not be extended to dinucleotide repeats due to the resolution characteristics of the available microchip. This novel approach was able to distinguish 17 microsatellite alleles varying from 0 to 17 repeats. Many of these alleles were quite rare, but the seven more abundant accounted for over the 70% of allele distribution in control population. The standard deviation in the sizing of the most abundant alleles ranged from +0.60 to +/- 0.75 bp. This indicated that the size attribution to a conventional allele using the +/- 1 bp range around it allowed a confidence limit above the 80 %. The sizing of D19S394 obtained this way allowed the cosegregation analysis with both the FH mutations tested. Therefore, this innovative approach to microsatellite sizing was much simpler, but equally effective as traditional capillary electrophoresis, at least with tetranucleotide repeats.  相似文献   

12.
A simple amplified fragment length polymorphism (AFLP) model, using the bacteriophage lambda genome, was developed to test the reproducibility of this technique in an international comparative study. Using either non-selective or selective primers, nine fragments or subsets of two or three fragments, respectively, were predicted using in silico software. Under optimized conditions, all predicted fragments were experimentally generated. The reproducibility of the AFLP model was tested by submitting both "unknown" DNA template that had been restricted and ligated with AFLP linkers (R/L mixture) and corresponding primer pairs to nine laboratories participating in the study. Participants completed the final PCR step and then used either slab gel electrophoresis or CE to detect the AFLP fragments. The predicted fragments were identified by the majority of participants with size estimates consistently up to 3 base pair (bp) larger for slab gel electrophoresis than for CE. Shadow fragments, 3 bp larger than the predicted fragments, were often observed by study participants and organizers. The nine AFLP fragments exhibited relative intensities ranging from less than 3% to 22% and, apart from the two weakest fragments, with a % CV of 16 to 25. Fragments containing the highest guanine-cytosine (GC) content of 50-56% showed the greatest stability in the AFLP profiles.  相似文献   

13.
Cretich M  Chiari M  Rech I  Cova S 《Electrophoresis》2003,24(21):3793-3799
DNA fragment analysis requires the use of polymer solutions as sieving matrices. Generally, such matrices are constituted of high-molar-weight polymers employed at a concentration higher than their entanglement threshold concentration. These polymer solutions are highly viscous and difficult to use in the narrow channels of a microchip. Ultralarge polyacrylamides synthesized via a nonconventional method, being the low-temperature plasma-induced polymerization (PIP), were used as DNA sieving matrices for microchip electrophoresis. The distinctive features of these polymers (ultralarge molecular mass and linearity) allow their use at a dilute concentration. Dilute PIP polyacrylamides revealed a constant value of resolution in a broad range of DNA fragment sizes (123 bp-1353 bp), thus proving to be effective in common genotyping applications. Moreover, the low viscosity of the dilute solutions enable it to be easier and faster in filling the channel between runs, thus enhancing the throughput of the microchip devices.  相似文献   

14.
Amplification of genomic sequences flanked by delta elements of retrotransposons TY1 and TY2 is a reliable method for characterization of Saccharomyces cerevisiae strains. The aim of this study is to evaluate the usefulness of microfluidic electrophoresis (Caliper LabChip) to assess the factors that affect interlaboratory reproducibility of interdelta sequence typing for S. cerevisiae strain delimitation. We carried out experiments in two laboratories, using varying combinations of Taq DNA polymerases and thermal cyclers. The reproducibility of the technique is evaluated using non-parametric statistical tests and we show that the source of Taq DNA polymerase and technical differences between laboratories have the highest impact on reproducibility, whereas thermal cyclers have little impact. We also show that the comparative analysis of interdelta patterns is more reliable when fragment sizes are compared than when absolute and relative DNA concentrations of each band are considered. Interdelta analysis based on a smaller fraction of bands with intermediate sizes between 100 and 1000 bp yields the highest reproducibility.  相似文献   

15.
Luo Y  Zhang Q  Qin J  Lin B 《Electrophoresis》2007,28(24):4769-4771
Hydrostatic pressure sample injection method is able to minimize the number of electrodes needed for a microchip electrophoresis process; however, it neither can be applied for electrophoretic DNA sizing, nor can be implemented on the widely used single-cross microchip. This paper presents an injector design that makes the hydrostatic pressure sample injection method suitable for DNA sizing. By introducing an assistant channel into the normal double-cross injector, a rugged DNA sample plug suitable for sizing can be successfully formed within the cross area during the sample loading. This paper also demonstrates that the hydrostatic pressure sample injection can be performed in the single-cross microchip by controlling the radial position of the detection point in the separation channel. Rhodamine 123 and its derivative as model sample were successfully separated.  相似文献   

16.
Lin YW  Huang MF  Chang HT 《Electrophoresis》2005,26(2):320-330
Capillary electrophoresis (CE) and microchip capillary electrophoresis (MCE) using polymer solutions are two of the most powerful techniques for the analysis of DNA. Problems, such as the difficulty of filling polymer solution to small separation channels, recovering DNA, and narrow separation size ranges, have put a pressure on developing new techniques for DNA analysis. In this review, we deal with DNA separation using chip-based nanostructures and nanomaterials in CE and MCE. On the basis of the dependence of the mobility of DNA molecules on the size and shape of nanostructures, several unique chip-based devices have been developed for the separation of DNA, particularly for long DNA molecules. Unlike conventional CE and MCE methods, sieving matrices are not required when using nanostructures. Filling extremely low-viscosity nanomaterials in the presence and absence of polymer solutions to small separation channels is an alternative for the separations of DNA from several base pairs (bp) to tens kbp. The advantages and shortages of the use of nanostructured devices and nanomaterials for DNA separation are carefully addressed with respect to speed, resolution, reproducibility, costs, and operation.  相似文献   

17.
Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.  相似文献   

18.
Xu Z  Hirokawa T 《Electrophoresis》2004,25(14):2357-2362
We developed a novel on-line preconcentration procedure for microchip gel electrophoresis (MCGE), which enables application of electrokinetic supercharging (EKS) for highly sensitive detection of DNA fragments on a cross-geometry microchip. In comparison with conventional pinched injection using the cross microchip, the present approach allows loading a much larger amount of the sample by taking advantage of a newly developed operational mode. In order to obtain high preconcentration effect and prevent splitting of an enriched sample into subchannels, i.e., off the detector range, effects of the voltage applied on the reservoirs and the time of isotachophoretic preconcentration were examined. The optimal balance between the voltage and time was found for a high-sensitivity analysis of DNA fragments. After experimental optimization the detection limit of a 150 bp fragment was as low as 0.22 mg/L (S/N = 3) that is 10 times better than using the conventional pinched injection.  相似文献   

19.
Z Buzás  Z Boldogkoi 《Electrophoresis》1999,20(14):2838-2840
It has been known since 1990 that DNA curvature can be recognized on transverse pore gradient gels by an intersection of "Ferguson curves" with those of DNA size standards. The miniaturized PhastSystem polyacrylamide gels allow one to detect DNA curvature effortlessly and fast and at great economy of sample relative to alternative methods of electrophoresis. Using the transverse gradient gel electrophoresis method, it was found that the 660 bp length subfragment of the matrix attachment region (MAR) sequence of the chicken lysosyme gene migrates as a fragment of 800-900 bp length. When subjected to digestion with the restriction enzyme HaeIII, the fragment gives rise to two species of 248 and 412 bp length, respectively. The Ferguson curves of both species intersect with those of DNA size standards, indicating that both exhibit curvature. Only the curvature of the 412 bp fragment conforms to prediction. Ethidium bromide abolishes the effect of curvature on the fragment, reducing its apparent size from 900 to 660, the value obtained by agarose gel electrophoresis.  相似文献   

20.
PCR is an indispensable technique used in DNA analysis. However, with the traditional methods, the time spent on amplification and the subsequent analysis of PCR products is generally long. Therefore, it is essential to improve these two steps so that the whole procedure can be made faster. In the present work, with lambda-DNA as the control template, the amplification of 300-bp fragment could be completed within 37 s with capillary reaction chambers of LightCycler, and the following analysis of PCR products could be completed within 120 s with microchip electrophoresis as the detector. Since the high detection sensitivity of microchip electrophoresis, PCR products with template concentration as low as 5 fg/microL could be detected only after 435 s of amplification. In addition, based on additional optimized conditions simulated by CoventorWare, PCR microchips with distinct structure of the reaction chambers have been designed and successfully applied to the amplification of 300-bp fragment. By comparison, those chambers with ellipse and racket shapes were found to offer very high amplification efficiency. All of these results demonstrate the promise of integrating PCR and electrophoresis on microchip for developing easy-carrying instruments for the fast in situ detection of DNA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号