首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
A novel electrochemical biosensor design for glucosinolate determination involving bulk‐incorporation of the enzymes glucose oxidase and myrosinase into a colloidal gold ‐ multiwalled carbon nanotubes composite electrode using Teflon as binder is reported. Myrosinase catalyzes the hydrolysis of glucosinolate forming glucose, which is enzymatically oxidized. The generated hydrogen peroxide was electrochemically detected without mediator at the nanostructured composite electrode at E=+0.5 V vs. Ag/AgCl. Under the optimized conditions, the bienzyme MYR/GOx‐Aucoll‐MWCNT‐Teflon exhibited improved analytical characteristics for the glucosinolate sinigrin with respect to a biosensor constructed without gold nanoparticles, i.e. a MYR/GOx‐MWCNT‐Teflon electrode, as well as with respect to other glucosinolate biosensor designs reported in the literature. The biosensor exhibits good repeatability of the amperometric measurements and good interassay reproducibility. Furthermore, the biosensor exhibited a high selectivity with respect to various potential interferents. The usefulness of the biosensor was evaluated by the determination of glucosinolate in Brussel sprout seeds.  相似文献   

2.
In this work, a renewable tyrosinase-based biosensor was developed for the detection of catechol, using a carbon black paste electrode, without any mediator. The effect of pH, type of electrolyte, and amount of tyrosinase enzyme were explored for optimum analytical performance. The best-performing biosensor in amperometric experiments at potential −0.2 V vs. Ag/AgCl (3 mol L−1 KCl) was obtained using a 0.1 mol L−1 phosphate buffer solution (pH 7.0) as electrolyte. Under optimized conditions, the proposed biosensor had two concentration linear ranges from 5.0×10−9 to 4.8×10−8 and from 4.8×10−8 to 8.5×10−6 mol L−1 and a limit of detection of 1.5×10−9 mol L−1. The apparent Michaelis-Menten constant ( ) was calculated by the amperometric method, and the obtained value was 1.2×10−5 mol L−1 whose result was similar when compared with other studies previously. The biosensor was applied in river water samples, and the results were very satisfactory, with recoveries near 100 %. In addition, the response of this biosensor for different compounds, taking into account their molecular structures was investigated and the results obtained showed no interference with the response potential of catechol. The electrochemical biosensor developed in this work can be considered highly advantageous because it does not require the use of a mediator (direct detection) for electrochemical response, and also because it is based on a low-cost materials that can be used with success to immobilise other enzymes and/or biomolecules.  相似文献   

3.
《Analytical letters》2012,45(5):913-926
Abstract

A new nanocomposite was developed by combination of prussian blue (PB) nanoparticles and multiwalled carbon nanotubes (MWNTs) in the matrix of biopolymer chitosan (CHIT). The PB and MWNTs had a synergistic electrocatalytic effect toward the reduction of hydrogen peroxide. The CHIT/MWNTs/PB nanocomposite‐modified glassy carbon (GC) electrode could amplify the reduction current of hydrogen peroxide by ~35 times compared with that of CHIT/MWNTs/GC electrode and reduce the response time from ~60 s for CHIT/PB/GC to 3 s. Besides, the CHIT/MWNTs/PB nanocomposite‐modified GC electrode could reduce hydrogen peroxide at a much lower applied potential and inhibit the responses of interferents such as ascorbic acid (AA) uric acid (UA) and acetaminophen (AC). With glucose oxidase (GOx) as an enzyme model, a new glucose biosensor was fabricated. The biosensor exhibited excellent sensitivity (the detection limit is down to 2.5 µM), fast response time (less than 5 s), wide linear range (from 4 µM to 2 mM), and good selection.  相似文献   

4.
《Electroanalysis》2017,29(5):1267-1277
Graphite rod (GR) modified with electrochemicaly deposited gold nanoparticles (AuNPs) and adsorbed glucose oxidase (GOx) was used in amperometric glucose biosensor design. Enzymatic formation of polypyrrole (Ppy) on the surface of GOx/AuNPs/GR electrode was applied in order to improve analytical characteristics and stability of developed biosensor. The linear glucose detection range for Ppy/GOx/AuNPs/GR electrode was dependent on the duration of Ppy‐layer formation and the linear interval was extended up to 19.9 mmol L−1 after 21 h lasting synthesis of Ppy. The sensitivity of the developed biosensor was determined as 21.7 μA mM−1 cm−2, the limit of detection – 0.20 mmol L−1. Ppy/GOx/AuNPs/GR electrodes demonstrated advanced good stability (the t 1/2 was 9.8 days), quick detection of glucose (within 5 s) in the wide linear interval. Additionally, formed Ppy layer decreased the influence of electroactive species on the analytical signal. Developed biosensor is suitable for the determination of glucose in human serum samples.  相似文献   

5.
制备了易于磁性分离、硫堇(Thi)包覆的四氧化三铁(Fe3O4)纳米复合物。通过静电吸附作用,将萘酚(Nafion)、Thi包覆的Fe3O4复合纳米粒子层层修饰到玻碳电极表面,再利用Thi分子中的氨基吸附纳米金,最后固载甲胎蛋白抗体,从而制得灵敏度高、稳定性好的无试剂电流型甲胎蛋白免疫传感器。实验通过透射电子显微镜(TEM)对该复合纳米粒子进行表征,并用循环伏安法考察了电极的电化学特性。结果表明,Fe3O4/Thi复合纳米粒子修饰的电极在实验过程中呈现出良好的氧化还原活性,其检测范围为0.05~20μg/L,检出限为0.03μg/L。  相似文献   

6.
Visual detection method is a means of quantitative analysis by the naked eye through the comparison of color intensity or type of change. Owing to its simplicity, low-cost, rapid operation, and equipment-free, visual detection was widely used in the detection of numerous targets. Gold nanomaterials were widely used in the construction of visual biosensors due to its unique optical properties when compared to other nanomaterials. The local surface plasmon resonance absorption peak would change with the variety in the distance or the morphology. Herein, this paper reviewed the application of gold nanomaterials in the construction of visual biosensors for the detection of target molecules. Meanwhile, we pointed out the main problems of gold nanoparticles based colorimetric methods in the determination of actual samples. The forecast of gold nanoparticles based biosensor was also provided at the end of this article.  相似文献   

7.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

8.
This study furnished results on the enzymatic detection of phenolic compounds by means of a miniaturized heat-flow calorimeter (IC-calorimeter). Two enzymes were used: tyrosinase and peroxidase. Additionally to the investigations with the IC-calorimeter, measurements were carried out with a classical reaction calorimeter (LKB 8700) for the very slow reactions with tyrosinase. By way of contrast, the reactions with peroxidase are fast and seem more suitable for sensor application. The detection limit for the investigated phenolic compounds is of the order of 1 mmol l−1 . This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

9.
纳米铂颗粒修饰薄膜金电极的新型葡萄糖传感器研究   总被引:3,自引:2,他引:3  
在没有引入电子媒介体条件下,为了提高传感器的响应灵敏度,降低工作电位,利用电化学沉积法在薄膜金电极表面修饰纳米铂颗粒,并通过戊二醛固定酶的方法制备了一种新型生物传感器。研究了在薄膜金电极上修饰纳米铂颗粒前后传感器对低浓度葡萄糖的响应影响。结果表明,纳米铂颗粒修饰后所制备的葡萄糖传感器工作电位下降为0.4 V,测定葡萄糖的检出限从100μmol/L下降到10μmol/L。传感器对10~1300μmol/L低浓度葡萄糖的响应灵敏度为50.8 nA/(cm2μmol/L);响应时间30 s;r为0.9974;传感器精密度为2.1%,并具有较好的稳定性。  相似文献   

10.
A novel amperometric biosensor for glucose was developed by entrapping glucose oxidase (GOD) in a chitosan composite doped with ferrocene monocarboxylic acid‐aminated silica nanoparticles conjugate (FMC‐ASNPs) and multiwall carbon nanotubes (MWNTs). The entrapped FMC‐ASNPs conjugate performed excellent redox electrochemistry and the presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped GOD and was in favor of the accessibility of substrate to the active site of GOD, thus the affinity to substrates is improved greatly. Under optimal conditions this biosensor was able to detect glucose with a detection limit of 10 μM (S/N=3) in the linear range of 0.04 to 6.5 mM. The proximity of these three components FMC‐ASNPs, MWNTs and GOD enhanced the electron transfer between the film and electrode. This composite film can be extended to immobilize other enzymes and biomolecules, which will greatly facilitate the development of biosensors and other bioelectrochemical devices.  相似文献   

11.
This work constructed an amperometric biosensing platform using CuO doped mesoporous silica hybrid (CuO/SBA‐15) as a carrier. The CuO/SBA‐15 showed a pair of redox peaks of Cu2+/0. Upon immobilization of tyrosinase on the hybrid, the resulting biosensor exhibited a rapid (<0.5 s) and sensitive amperometric response to phenolic compounds under the optimized conditions. The linear response to catechol ranged from 1.2×10?9 to 3.0×10?5 M. The activation energy for enzymatic reaction was calculated to be 26.6 kJ mol?1. The apparent Michaelis–Menten constants of the enzyme electrode were estimated to be 54.6, 145, 17.0, 74.8 and 633 µM for catechol, phenol, p‐cresol, m‐cresol and dopamine hydrochloride, respectively. The metal oxide doped mesoporous silica hybrid exhibited excellent performance for construction of new biosensors.  相似文献   

12.
《Electroanalysis》2005,17(23):2147-2155
A laccase biosensor, in which the enzyme was immobilized on N‐succinimidyl‐3‐thiopropionate (NSTP)‐modified gold electrodes, is reported. Two different approaches for the preparation of N‐succinimidyl‐terminated monolayers were evaluated: a) activation of a preformed 3‐mercaptopropionic acid (MPA) SAM by reaction with 1‐(3‐dimethylaminopropyl)‐ 3‐ethylcarbodiimide (EDC) and N‐hydroxysulfosuccinimide (NHS); b) assembling of dithiobisuccinimidyl propionate (DTSP). NSTP‐modified electrodes were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Biosensors prepared by covalent binding of the enzyme and by cross‐linking with glutaraldehyde atop NSTP‐modified electrodes were compared in terms of sensitivity and operational range for caffeic acid. A much better analytical performance was found using the latter approach. Variables affecting the amperometric detection (enzyme loading, pH and applied potential) were optimized. The operational stability and characteristics of functioning of the laccase biosensor in terms of repeatability of the amperometric measurements, reproducibility with different biosensors and useful lifetime, were evaluated. The kinetic parameters of the enzyme reactions and the analytical characteristics of the corresponding calibration plots were calculated for eight phenolic compounds. Limits of detection of 0.07 μM, 0.05 μM and 0.09 μM were obtained for caffeic acid, catechol and 3,4‐dihydroxyphenylacetic acid (DOPAC), respectively. The practical usefulness of the developed biosensor was evaluated by estimating the “pool” of phenolic compounds in olive oil mill wastewaters (OMW).  相似文献   

13.
采用层层自组装技术制备了快速检测有机磷农药的生物传感器,利用带正电荷的高分子聚电解质聚二烯丙基二甲基氯化铵(PDDA)将乙酰胆碱酯酶(AChE)和金纳米粒子(AuNPs)通过静电力逐层固定到玻碳电极(GCE)表面,并采用交流阻抗和微分脉冲伏安法研究了此生物传感器的电化学行为。由于金纳米粒子优异的电催化性能和良好的生物相容性,使固定化的乙酰胆碱酯酶对其底物具有更高的亲和力和更快的响应速度。实验结果表明:修饰金纳米粒子后,传感器的氧化电流明显增大,在4.6×10-5~5.3×10-3mol/L范围内,固定化酶的抑制率与甲基对硫磷浓度的对数成正比,检出限为7.6×10-6mol/L。该生物传感器具有制备方法简便、成本低、灵敏度高等优点,已成功用于蔬菜样品中甲基对硫磷含量的测定。  相似文献   

14.
Poly(3,4‐ethylenedioxythiophene) (PEDOT) and its derivatives are relatively new, and unique members of conducting‐polymers family. In this article, we present an approach for simple, reliable and cost‐efficient electrochemical biosensor for real‐time detection and quantification of phenolic compounds (PhCs). The PEDOT:poly(styrene sulfonate) (PSS) polymer, directly screen‐printed on the surface of the working electrode, was shown to act as an effective electrical conductor but also as an efficient redox mediator. It has also been found suitable for the reduction of quinone ions at low reducing potentials, close to 0 V versus Ag/AgCl, thus minimizing interferences due to other electroactive species present in real samples. Based on these properties, a biosensor based on tyrosinase immobilized on PEDOT:PSS‐modified electrodes was developed allowing the detection of PhCs in surface waters. The biosensor displayed very good performance in terms of sensitivity, detection limit and linear range. Assays using surface water previously spiked with bisphenol A showed that the biosensor was able to detect PhCs in real conditions with no matrix effect. © 2012 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2012  相似文献   

15.
《Electroanalysis》2005,17(23):2137-2146
A screen‐printed four‐electrode sensor based on immobilization of laccase (Coriolus hirsutus), peroxidase (horseradish) and tyrosinase (mushroom) in the same array was developed for monitoring of phenols. The enzymes were immobilized onto a self‐assembled monolayer (4‐mercapto‐1‐butanol) modified gold surface via covalent attachment by epichlorohydrin coupling. The experimental conditions for simultaneous operation of the three enzymes were optimized based on catechol determination. The sensors were further applied for the amperometric detection of several substituted phenolic compounds, carried out using a single line flow‐injection system. Hydrogen peroxide served as co‐substrate for peroxidase. The limits of detection for phenols in aqueous solutions were in the micromolar range, one assay was completed in less than 5 min. The preliminary studies showed that the compatibility of the above mentioned enzyme array enabled the multielectrode biosensor to be applied to real samples including industrial wastewaters and surface waters.  相似文献   

16.
高盐生  王媛  狄俊伟 《应用化学》2010,27(3):363-366
采用溶胶-凝胶技术将金纳米粒子和葡萄糖氧化酶一次性固定于硅溶胶-凝胶的网络结构中,制备了葡萄糖生物电化学传感器并优化了传感器的制备条件。酶电极对葡萄糖具有良好的电化学响应,葡萄糖浓度在0.02~2.0 mmol/L范围内和催化电流呈线性关系,检出限为0.005 mmol/L。酶电极在4 ℃下贮存100 d后对葡萄糖的响应仅下降8%。该酶电极灵敏度高、响应快、稳定性好。  相似文献   

17.
《Electroanalysis》2006,18(21):2043-2048
A new biosensor is described for the detection of S‐nitrosothiols (RSNOs) based on their decomposition by immobilized glutathione peroxidase (GPx), an enzyme containing selenocysteine residue that catalytically produces nitric oxide (NO) from RSNOs. The enzyme is entrapped at the distal tip of a planar amperometric NO sensor. The new biosensor shows good sensitivity, linearity, reversibility, and response times towards various RSNO species in PBS buffer, pH 7.4 . In most cases, the response time is less than 5 min, and the response is linear up to 6 μM of the tested RSNO species. The lowest detection limit is obtained for S‐nitrosocysteine (CysNO), at approx. 0.2 μM. The biosensor's sensitivity is not affected by the addition of EDTA as a chelating agent; an advantage over other potential catalytic enzymes that contain copper ion centers, such as CuZn‐superoxide dismutase and xanthine oxidase. However, lifetime of the new sensor is limited, with sensitivity decrease of 50% after two days of use. Nonetheless, the new amperometric GPx based RSNO sensor could prove useful for detecting relative RSNO levels in biological samples, including whole blood.  相似文献   

18.
In this report, a label‐free electrochemical aptasensor for carcino‐embryonic antigen (CEA) was successfully developed based on a ternary nanocomposite of gold nanoparticles, hemin and graphene nanosheets (AuNPs‐HGNs). This nanocomposite was prepared by decorating gold nanoparticles on the surface of hemin functionalized graphene nanosheets via a simple wet‐chemical strategy. The aptamer can be assembled on the surface of AuNPs‐HGNs/GCE (glassy carbon electrode) through Au‐S covalent bond to form the sensing interface. Hemin absorbed on the graphene nanosheets not only acts as a protective agent of graphene sheets, but also as an in situ probe base on its excellent redox properties. Gold nanoparticles provide with both numerous binding sites for loading CEA binding aptamer (CBA) and good conductivity to promote the electron transfer. The current changes, which are caused by CEA specifically binding on the modified electrode, are exploited for the label‐free detection of CEA in a very rapid and convenient protocol. Therefore, the method has advantages of high sensitivity, wide linear range (0.0001–10 ng mL?1), low detection limit (40 fg mL?1) and attractive specificity. The results illustrate that the proposed label‐free electrochemical aptasensor has a potential application in the biological or clinical target analysis for its simple operation and low cost.  相似文献   

19.
基于纳米金和硫堇固定酶的过氧化氢生物传感器   总被引:7,自引:0,他引:7  
在铂电极上自组装一层纳米金(GNs), 构建负电荷的界面, 然后通过金-硫、金-氮共价键合作用和静电吸附作用自组装一层阳离子电子媒介体硫堇(Thio). 再以同样的作用自组装一层GNs和辣根过氧化酶(HRP)的混合物, 最后在电极最外层滴加一层疏水性聚合物壳聚糖(Chit), 由此制备了一种新型的过氧化氢生物传感器. 研究了工作电位、检测底液pH、温度对响应电流的影响, 以及GNs和HRP之间的相互作用, 探讨了传感器的表面形态、交流阻抗、重现性和稳定性. 该传感器的酶催化反应活化能为12.4 kJ/mol, 表观米氏常数为6.5×10-4 mo/L, 在优化的实验条件下, 所研制的传感器对H2O2的线性范围为5.6×10-5~2.6×10-3 mol/L, 检出限为1.5×10-5 mol/L. 应用此方法制备了HRP和葡萄糖氧化酶(GOD)双酶体系葡萄糖生物传感器, 并应用于实验样品葡萄糖含量的测定.  相似文献   

20.
Herein, we describe a new method for the detection of hydrogen peroxide (H2O2) in food by using an electrochemical biosensor. Initially, ultrafine gold nanoparticles dispersed on graphene oxide (AuNP‐GO) were synthesized by the redox reaction between AuCl4? and GO, and thionine‐catalase conjugates were then assembled onto the AuNP‐GO surface on a glassy carbon electrode. With the aid of the AuNP‐GO, the as‐prepared biosensor exhibited good electrocatalytic efficiency toward the reduction of H2O2 in pH 5.8 acetic acid buffer. Under optimal conditions, the dynamic responses of the biosensor toward H2O2 were achieved in the range from 0.1 µM to 2.3 mM, and the detection limit (LOD) was 0.01 µM at 3sB. The Michaelis–Menten constant was measured to be 0.98 mM. In addition, the repeatability, reproducibility, selectivity and stability of the biosensor were investigated and evaluated in detail. Finally, the method was applied for sensing H2O2 in spiked or naturally contaminated samples including sterilized milk, apple juices, watermelon juice, coconut milk, and mango juice, receiving good correspondence with the results from the permanganate titration method. The disposable biosensor could offer a great potential for rapid, cost‐effective and on‐field analysis of H2O2 in foodstuff.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号