首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
A simple method of solventless extraction of volatile organic compounds (benzene, toluene, ethylbenzene and xylenes) from aqueous samples was developed. This method allows direct injection of large volume of water sample into a gas chromatograph using the sorption capacity of the sorbent Chromosorb P NAW applied directly in the injection port of gas chromatograph. The system prevent water penetration into a column, keep it adsorbed on its surface until the analytes are stripped into a column, and the residual water is purging using split flow. The limit of detection ranging from 0.6 for benzene to 1.1 microg l(-1) for o-xylene and limit of quantification ranging 2.0-3.6 microg l(-1) are lower that those reached by gas chromatography with flame ionization detection and direct aqueous injection before.  相似文献   

2.
The primary standard test method used for the determination of gasoline diluent in used engine oils is method D 3525-93 of the American Society for Testing and Materials (ASTM), which involves direct injection of used oil onto a packed GC column and flame ionization detection. Recently, we have utilized a new headspace sampling method: headspace solvent microextraction (HSM), for GC and GC-MS analysis of gasoline diluent in used engine oils. High resolution capillary columns can be used without the necessity for the use of inlet cryogenic cooling or expensive sampling interfaces. This analytical method, which we generically refer to as headspace microdrop analysis yields results comparable to those obtained using the ASTM method, with the added benefit that it allows the quantification of individual volatile diluent components, including benzene, toluene, ethylbenzene and the xylenes.  相似文献   

3.
韩东强  马万云  陈瓞延 《分析化学》2006,34(10):1361-1365
苯、甲苯、乙苯和二甲苯(简称BTEX)等单环芳烃是石油的重要组分。在油气地球化学勘查领域,BTEX是油气藏信息的直接指示物。BTEX具有挥发性,并且可以受到微生物的降解作用,直接影响到BTEX含量的准确测量。本研究建立了动态顶空(吹扫捕集)和光离子化检测器(PID)的气相色谱测量海水基样品中BTEX的生物降解方法。苯、甲苯、乙苯、对间二甲苯及邻二甲苯的检出限分别为7.3、8.1、11.4、8.3、13.2ng/L;1μg/L海水样品中BTEX回收率为92.84%~100.92%。样品无需预处理。BTEX生物降解规律对海洋油气地球化学勘探中所涉及的样品采集、运输、保存、测量及结果分析具有重要指导意义。  相似文献   

4.
This study describes a method for the quantification of trace‐level benzene, toluene, ethylbenzene, and xylene in cellulose acetate tow by heart‐cutting multidimensional gas chromatography with mass spectrometry in selected ion monitoring mode. As the major volatile component in cellulose acetate tow samples, acetone would be overloaded when attempting to perform a high‐resolution separation to analyze trace benzene, toluene, ethylbenzene, and xylene. With heart‐cutting technology, a larger volume injection was achieved and acetone was easily cut off by employing a capillary column with inner diameter of 0.32 mm in the primary gas chromatography. Only benzene, toluene, ethylbenzene, and xylene were directed to the secondary column to result in an effective separation. The matrix interference was minimized and the peak shapes were greatly improved. Finally, quantitative analysis of benzene, toluene, ethylbenzene, and xylene was performed using an isotopically labeled internal standard. The headspace multidimensional gas chromatography mass spectrometry system was proved to be a powerful tool for analyzing trace volatile organic compounds in complex samples.  相似文献   

5.
A new protocol for the simultaneous determination of methyl tert-butyl ether (MTBE); its main degradation products: tert-butyl alcohol (TBA) and tert-butyl formate (TBF); other gasoline additives, oxygenate dialkyl ethers: ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME) and diisopropyl ether (DIPE); aromatics: benzene, toluene, ethylbenzene and xylenes (BTEX) and other compounds causing odour events such as dicyclopentadiene (DCPD) and trichloroethylene (TCE) in soils has been developed. On the basis of US Environmental Protection Agency (EPA) method 5035A, a fully automated closed-system purge-and-trap coupled to gas chromatography/mass spectrometry (P&T-GC/MS) was optimised and permitted to detect microg/kg concentrations in solid matrices avoiding losses of volatile compounds during operation processes. Parameters optimised were the sampling procedure, sample preservation and storage, purging temperature, matrix effects and quantification mode. Using 5 g of sample, detection limits were between 0.02 and 1.63 microg/kg and acceptable method precision and accuracy was obtained provided quantification was performed using adequate internal standards. Soil samples should be analysed as soon as possible after collection, stored under -15 degrees C for not longer than 7 days if degradation products have to be analysed. The non-preservative alternative (empty vial) provided good recoveries of the most analytes when freezing the samples up to 7 day holding time, however, if biologically active soil are analysed the preservation with trisodium phosphate dodecahydrate (Na(3)PO(4).12H(2)O or TSP) is strongly recommended more than sodium bisulphate (NaHSO(4)). The method was finally applied to provide threshold and background levels of several gasoline additives in a point source and in sites not influenced by gasoline spills. The proposed method provides the directions for the future application on real samples in current monitoring programs at gasoline pollution risk sites where till now little monitoring data for MTBE in soils are available.  相似文献   

6.
Comprehensive two-dimensional gas chromatography (GC×GC) has been applied to the quantitative analysis of benzene, toluene, ethylbenzene, xylenes (BTEX), and all heavier aromatic compounds in gasoline. The two-dimensional chromatographic separation used volatility selection on the first-dimension column and polarity selection on the second-dimension column. In the resulting GC×GC chromatogram, aromatic species were resolved from other compound classes. Moreover, structurally related aromatics were grouped in a manner that facilitated identification and integration. The response of a flame ionization detector to each major aromatic group in gasoline was calibrated using internal standards. Quantitation produced results directly comparable with ASTM standard methods. The present GC×GC method can be expanded to analyze other gasoline components.  相似文献   

7.
A method based on solid-phase microextraction (SPME) and gas chromatography with flame ionization detection (GC-FID) has been optimized for the determination of benzene, toluene, ethylbenzene and xylenes (BTEX) in water released from a waste treatment plant. The extraction step was optimized using fractional factorial and central composite designs including the following experimental factors: saline concentration; extraction time; desorption time; agitation velocity; headspace volume. A multiple function was used to describe the experimental conditions for simultaneous extraction of the compounds. The procedure, based on direct SPME at 50 degrees C, using a polydimethylsiloxane fiber, showed good linearity (r>0.997 over a concentration range 2-200 microg L(-1)) and repeatability (relative standard deviation (RSD)<4.23%) for all compounds, with limits of detection ranging from 0.05 to 0.28 microg L(-1), and limits of quantification ranging from 0.14 to 0.84 microg L(-1). Concentrations of the target compounds in these samples were between 145.8 and 1891 microg L(-1).  相似文献   

8.
The aim of this study was to determine whether the new ionic liquid, N,N‐dimethyl‐2‐oxopyrrolidonium iodide, synthesized in our laboratory is a suitable solvent for the separation of aromatic components benzene, toluene, ethylbenzene, and xylenes from petroleum mixtures (reformates) in liquid–liquid extraction. In pursuance of the above aim, a method to extract all components of a mixture, containing four aromatic components simultaneously, was developed. A new ionic liquid and a previously used liquid were compared for their extraction abilities. These ionic liquids were, respectively, N,N‐dimethyl‐2‐oxopyrrolidinium iodide and 1‐ethyl‐3‐methyl imidazolium ethyl sulfate. The concentrations of each benzene, toluene, ethylbenzene, and xylenes component in the extract and raffinate phases were measured by gas chromatography with flame ionization detection as volume percent to determine the extraction ability of the ionic liquids. The results obtained for both the reformate samples and model mixtures indicated that the new ionic liquid was effective as an extracting solvent for the recovery of aromatic components from reformates. Also the analysis results, using gas chromatography with flame ionization detection, for the reformate samples were as good as the results obtained by a local oil refinery. The extraction results also show that the developed method is very suitable for the separation and analysis of aromatic components in reformates.  相似文献   

9.
A method for determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in urine is described. Determination is performed by dynamic headspace (purge and trap) gas chromatography with photoionization detection. The features of the described method, i.e. detection limits of 15–35 ng L–1, relative standard deviations of 0.2–10%, accuracy of 80–100%, removal of interference of many compounds present in urine, sharp chromatographic peaks because of cryogenic refocusing, no sample preparation, make it convenient for biological monitoring of exposure to low levels of BTEX. However, the method is time‐consuming and sophisticated.  相似文献   

10.
The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).  相似文献   

11.
Han  Dongqiang  Ma  Wanyun  Chen  Dieyan 《Chromatographia》2007,66(11):899-904

Benzene, toluene, ethylbenzene, and xylenes (BTEX) are commonly found in crude oil and are used in geochemical investigations as direct indicators of the presence of oil and gas. BTEX are easily volatile and can be degraded by microorganisms, which affect their precise measurement seriously. A method for determining the biodegradation process of BTEX in seabed sediment using dynamic headspace (purge and trap) gas chromatography with a photoionization detector (PID) was developed, which had a detection limit of 7.3–13.2 ng L−1 and a recovery rate of 91.6–95.0%. The decrease in the concentration of BTEX components was monitored in seabed sediment samples, which was caused by microorganism biodegradation. The results of BTEX biodegradation process were of great significance in the collection, transportation, preservation, and measurement of seabed sediment samples in the geochemical investigations of oil and gas.

  相似文献   

12.
单环芳烃苯、甲苯、乙苯和二甲苯(简称BTEX)是石油的重要组分,也是环境中需要重点监测的致癌污染物。本实验建立了动态顶空(吹扫捕集)和光离子化检测器的气相色谱测量海水、沉积物中痕量BTEX的方法。在120—1200ng/L的浓度范围,苯、甲苯、乙苯、间对二甲苯及邻二甲苯标准溶液的检出限分别为6.4、35.2、15.8、12.3、10.7ng/L,相对标准偏差0.9%-6.1%。样品无需预处理,海水中BTEX回收率为93.50%-98.40%。7个渤海表层海水样品中BTEX的浓度均低于140ng/L;海底沉积物中苯、甲苯、乙苯、间对二甲苯及邻二甲苯浓度分别为169—1243、531—1732、1308—5624、237—1136、510—5194ng/L。测量方法和结果对评价环境污染具有重要意义。  相似文献   

13.
A newly designed needle trap device with Carbopack X as a sorbent material is used for sampling, preconcentration and injection of volatile analytes benzene, toluene, ethylbenzene and xylenes (BTEX) into gas chromatograph. The closed system of stripping the analytes from water samples was used. An injection port with a modified metal liner was used to desorb analytes trapped in needle trap device. The main advantage of needle trap device consists in the simple methodology and easiness and rapidity of the analysis. Needle trap device is suitable for sampling in field. The experimental parameters as breakthrough volume of stripping gas, linearity, repeatability and limit of detection (LOD) and quantification (LOQ) were investigated. LOD ranges from 0.05 to 0.07 microgL(-1) and relative standard deviation ranges from 0.5% to 11.6% at concentrations 5 and 0.1 microgL(-1), respectively.  相似文献   

14.
Benzene, toluene, ethylbenzene, and xylenes (BTEX) are commonly found in crude oil and are used in geochemical investigations as direct indicators of the presence of oil and gas. BTEX are easily volatile and can be degraded by microorganisms, which affect their precise measurement seriously. A method for determining the biodegradation process of BTEX in seabed sediment using dynamic headspace (purge and trap) gas chromatography with a photoionization detector (PID) was developed, which had a detection limit of 7.3–13.2 ng L?1 and a recovery rate of 91.6–95.0%. The decrease in the concentration of BTEX components was monitored in seabed sediment samples, which was caused by microorganism biodegradation. The results of BTEX biodegradation process were of great significance in the collection, transportation, preservation, and measurement of seabed sediment samples in the geochemical investigations of oil and gas.  相似文献   

15.
Benzylsuccinic acid (BSA) and methylbenzylsuccinic acid (methyl-BSA) are unambiguous biotransformation products resulting from anaerobic toluene and xylene biodegradation, respectively. A solid-phase extraction method based on polystyrene-divinylbenzene sorbent was developed for the quantitative BSA determination in groundwater samples as an alternative to liquid-liquid extraction. Gas chromatography coupled with mass spectrometry was used for separation and detection. The recovery from spiked 11 groundwater samples was 88 to 100%. The precision of the method, indicated by the relative standard deviation, was +/- 4% and the method detection limit was 0.2 microg/l. The concentration of BSA and methyl-BSA in groundwater samples from anaerobic BTEX (benzene, toluene, ethylbenzene and xylenes)-contaminated sites ranged from below the detection limit (3 microg/l) to 155 microg/l.  相似文献   

16.
Solid-phase microextraction (SPME) with a disposable ionic liquid (IL) coating was developed for headspace extraction of benzene, toluene, ethylbenzene, and xylenes (BTEX) in paints. The SPME fiber was coated with IL prior to every extraction, then the analytes were extracted and desorbed on the injection port of gas chromatography, and finally the IL coating on the fiber was washed out with solvents. The coating and washing out of IL from the fiber can be finished in a few minutes. This disposable IL-coated fiber was applied to determine BTEX in water-soluble paints with results in good agreement with that obtained by using commercially available SPME fibers. For all the four studied paints samples, the benzene contents were under the detection limits, but relatively high contents of toluene, ethylbenzene and xylenes (56-271 microg g(-1)) were detected with spiked recoveries in the range of 70-114%. Compared to the widely used commercially available SPME fibers, this proposed disposable IL-coated fiber has much lower cost per determination, comparable reproducibility (RSD < 11%), and no carryover between each determination. Considering that IL possess good extractability for various organic compounds and metals ions, and that task-specific IL can be designed and synthesized for selective extraction of target analytes, this disposable IL coating SPME might has great potential in sample preparation.  相似文献   

17.
A method of solventless extraction of volatile organic compounds from aqueous samples has been developed and validated. A new arrangement in which the internal volume of a needle capillary adsorption trap is completely filled with Porapak Q, as adsorbent material, and wet alumina, as a source of desorptive water vapor flow, is presented. The device has been used for head-space sampling of benzene, toluene, ethylbenzene, and xylenes (BTEX) from water samples and compared with solid-phase microextraction. Under the same sampling conditions the analytical characteristics of the device for the BTEX compounds are better than those of solid-phase microextraction. Limits of detection and quantification are below 0.5 μ g L−1.  相似文献   

18.
A simple procedure for the determination of methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), ethyl butyl ether (EBE), tert-amyl methyl ether (TAME), benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using headspace (HS) solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with flame ionization detector (FID) and 100% dimethylpolysiloxane fused capillary column. A 2 Plackett-Burman design for screening and a central composite design (CCD) for optimizing the significant variables were applied. Fiber type, extraction temperature, sodium chloride concentration, and headspace volume were the significant variables. A 65 microm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 10 degrees C, 300 g/l, and 20 ml of headspace (in 40 ml vial) were respectively chosen for the best extraction response. An extraction time of 10 min was enough to extract the ethers and BTEX. The relative standard deviation (R.S.D.) for the procedure varied from 2.6 (benzene) to 8.5% (ethylbenzene). The method detection limits (MDLs) found were from 0.02 (toluene, ethylbenzene, and xylenes) to 1.1 microg/l (MTBE). The optimized method was applied to the analysis of the rivers, marinas and fishing harbors surface waters from Gipuzkoa (North Spain). Three sampling were done in 1 year from June 2002 to June 2003. Toluene was the most detected analyte (in 90% of the samples analyzed), with an average concentration of 0.56 microg/l. MTBE was the only dialkyl ether detected (in 15% of the samples) showing two high levels over 400 microg/l that were related to accidental fuel spill.  相似文献   

19.
SK Corporation developed an advanced pyrolysis gasoline (pygas) upgrading (APUSM) technology based on a catalytic process for producing valuable benzene, toluene and xylenes (BTX) and liquefied petroleum gas (LPG) from pygas containing aromatics and non-aromatic hydrocarbons. Hydrodealkylation of heavy aromatics and hydrocracking of non-aromatic hydrocarbons occurred with facility in the conversion of pygas over a proprietary catalyst, metal promoted zeolite. This catalytic process produced benzene and toluene with high purity corresponding to chemical grade while giving mixed xylenes with reduced ethylbenzene. In the present study, we described novel features of the APUSM technology in terms of the process and catalyst. The influence of the process conditions was also examined. This technology has been commercially proven, and hence is available for licensing through Axens, which is a major engineering and licensing company.  相似文献   

20.
A method based on simplified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) extraction followed by large-injection volume-fast gas chromatography and mass spectrometry detection has been developed for the determination of trihalomethanes (chloroform, bromodichloromethane, dibromochloromethane and bromoform) and BTEX (benzene, toluene, ethylbenzene and xylenes) in soil samples.The simplified version of QuEChERS used meets the requirements of the “green chemistry” and provides reliable results with high sample throughput, low solvent consumption, little labour and the use of materials commonly employed in laboratories. The GC device used is equipped with a programmable temperature vaporizer (PTV), with a liner packed with Tenax-TA®. Using the solvent-vent mode, the PTV allows the injection of large volumes of sample, affording an improvement in the sensitivity of the method. The chromatographic conditions used here allowed the separation of the compounds in less than 5.50 min. Good linearity was obtained for all the target compounds, with highly satisfactory repeatability and reproducibility values. The limits of detection were in the 0.2 to 15 μg kg−1 range. The method was validated by the analysis of two certified reference materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏