共查询到20条相似文献,搜索用时 12 毫秒
1.
Jing Zhao Erwei Liu Lifeng Han Linlin Wang Yi Zhang Tao Wang Shiming Fang Xiumei Gao 《Biomedical chromatography : BMC》2016,30(6):846-851
A sensitive, rapid and specific high‐performance liquid chromatography tandem mass spectrometry method (HPLC‐MS/MS) was developed to determine ecliptasaponin A in rat plasma and tissues after oral administration. Ginsenoside Rg1 was used as the internal standard (IS). The plasma and tissues samples were prepared by liquid‐liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (2.1 mm × 150 mm, 5 µm) at a flow rate of 0.4 mL/min using acetonitrile and water (containing 0.05% acetic acid) as the mobile phase. The tandem mass detection was carried out with eletrospray ionization in negative mode. Quantification was performed by using multiple reaction monitoring (MRM), which monitored the fragmentation of m/z 633.4→587.2 for ecliptasaponin A and m/z 859.4→637.4 for the IS. The calibration curves obtained were linear in different matrices, and the lower limit of quantification (LLOQ) achieved was 0.5 ng/mL both for rat plasma and tissues. The intra‐ and inter‐day precisions were below 15%. This method was successfully applied to pharmacokinetic study of ecliptasaponin A in rat plasma and tissues after oral administration. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
2.
A sensitive, fast and simple method based on magnetic octadecylsilane particles was developed for the extraction of three fat‐soluble vitamins followed by capillary LC (CLC) analysis with UV detection. Magnetic octadecylsilane particles were prepared based on three‐step reactions including co‐precipitation, sol‐gel polymerization and alkylation. The characterization of the prepared product was studied by scanning electron microscope and Fourier‐transform infrared spectrometry. The particles were used as magnetic SPE adsorbent for the extraction of fat‐soluble vitamins in fruit juice‐milk beverage. The extraction condition and efficiency of the particles for fat‐soluble vitamins were investigated. By coupling magnetic SPE with capillary LC with UV detection, low concentrations of fat‐soluble vitamins in fruit juice‐milk beverage can be detected without the interference from other substances in the sample matrix. 相似文献
3.
Determination of nifedipine in dog plasma by high‐performance liquid chromatography with tandem mass spectrometric detection 下载免费PDF全文
Xigui Pan Shunchang Zhou Qinqin Fu Xianming Hu Jianhong Wu 《Biomedical chromatography : BMC》2014,28(7):1036-1040
Nifedipine is a dihydropyridine calcium channel blocker used widely in the management of hypertension and other cardiovascular disorders. In this work, a simple, rapid and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated to determine nifedipine in dog plasma using nimodipine as the internal standard. Chromatographic separation was carried out on a C8 column. The mobile phase consisted of a mixture of acetonitrile, water and formic acid (60:40:0.2, v/v/v) at a flow rate of 0.5 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode via an atmospheric pressure chemical ionization source. The method has a lower limit of quantification of 0.20 ng/mL with consumption of plasma as low as 0.05 mL. The linear calibration curves were obtained in the concentration range of 0.20–50.0 ng/mL (r = 0.9948). The recoveries of the liquid extraction method were 74.5–84.1%. Intra‐day and inter‐day precisions were 4.1–8.8 and 6.7–7.4%, respectively. The quantification was not interfered with by other plasma components and the method was applied to determine nifedipine in plasma after a single oral administration of two controlled‐release nifedipine tablets to beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
4.
Bo Jiang Zourong Ruan Honggang Lou Xinwei Dong Qiangmin Xie 《Biomedical chromatography : BMC》2010,24(5):490-496
A rapid, selective and sensitive liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determining bencycloquidium bromide (BCQB) in beagle dog plasma. The plasma sample was deproteinized with methanol which contained l‐ethyl‐bencycloquidium bromide as internal standard, and supernantant was assayed by LC‐MS/MS. The chromatographic separation was performed on a Phenomenex C18 column (100 × 2.0 mm, i.d., 3.0 μm) with a gradient programme mobile phase consisting of methanol and ammonium acetate (5 mm) containing 0.15% acetic acid and at a flow rate of 0.3 mL/min. Electrospray ionization in positive ion mode and selective reaction monitoring was used for the quantification of BCQB with a monitored transitions m/z 330.2 → 142.1 for BCQB and m/z 344.2 → 126.2 for IS. Validation results indicated that the lower limit of quantification was 0.05 ng/mL and the assay exhibited a linear range of 0.05–10.0 ng/mL and gave a correlation coefficient of 0.9998. The intra‐ and inter‐run precisions of the assay were 1.7–4.6 and 3.2–15.6%, respectively, and the intra‐ and inter‐day accuracies were ?8.8 to 1.1 and ?5.0 to 4.6%, respectively. The developed method was applied for the pharmacokinetic study of BCQB in beagle dogs following a single intranasal dose. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
5.
Sørensen LK 《Biomedical chromatography : BMC》2010,24(11):1208-1212
A liquid chromatographic/tandem mass spectrometric method using pneumatically assisted electrospray ionization (LC-ESI-MS/MS) was developed for determination of N-acetylneuramic acid and N-glycolylneuramic acid in infant formula. Reconstituted samples were hydrolysed in dilute sulfuric acid and deproteinized with acetonitrile. The extract was analysed directly without further clean-up by hydrophilic interaction chromatography. The substances were detected in negative ion mode and matrix matched standards were used for calibration. The relative intra-laboratory reproducibility standard deviation was better than 6% for both substances. An R2 of 0.985 was obtained by comparison with a classical colorimetric assay based on reaction with resorcinol. The developed method is expected to be applied for accurate routine analysis of infant formulas. 相似文献
6.
Liu XY Qu TT Wang BJ Wei CM Yuan GY Zhang R Guo RC 《Biomedical chromatography : BMC》2008,22(9):1021-1027
A sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of sodium cromoglycate (SCG) in human plasma after a nasal dose of 10.4 mg sodium cromoglycate nasal spray, using pravastatin sodium as the internal standard. The method was validated over a linear range of 0.300-20.0 ng/mL. SCG and I.S. were extracted from 1.0 mL of heparinized plasma by C(18) solid-phase extraction cartridges using methanol as eluting solvent. The dried residue was reconstituted with 100 microL of mobile phase, and 10 microL was injected onto the LC-MS/MS system. Chromatographic separation was achieved on a C(18) column (250 x 4.6 mm i.d., 5 microm particle size) with a mobile phase of methanol-acetonitrile-water (containing 2 mmol/L ammonium acetate; 42.5:42.5:15, v/v/v) at a flow rate of 0.4 mL/min. The analytes were detected with a triple quad LC-MS/MS using ESI with positive ionization. Ions monitored in the multiple reaction monitoring mode were m/z 469.0 (precursor ion) to m/z 245.0 (product ion) for SCG and m/z 447.2 (precursor ion) to m/z327.1 (product ion) for pravastatin sodium (internal standard) The average recovery of SCG from human plasma was 94.88% and the lower limit of quantitation was 0.3 ng/mL. Results from a 3-day validation study demonstrated excellent precision and accuracy across the calibration range of 0.3-20 ng/mL. The method was successfully applied to the pharmacokinetic study of SCG in healthy Chinese volunteers. Copyright (c) 2008 John Wiley & Sons, Ltd. 相似文献
7.
A sensitive and selective liquid chromatography tandem mass spectrometry method for determination of azasetron hydrochloride in rabbit plasma was developed. After addition of doxapram hydrochloride as internal standard (IS), protein precipitation by 10% trichloroacetic acid was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C(18) (2.1 × 50 mm, 3.5 μm) column with acetonitrile-water as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used to quantification using target fragment ions m/z 349.9 → 223.5 for azasetron hydrochloride and m/z 378.9 → 291.8 for the IS. Calibration plots were linear over the range of 6-1000 ng/mL for azasetron hydrochloride in plasma. The lower limit of quantitation for azasetron hydrochloride was 6 ng/mL. The mean recovery of azasetron hydrochloride from plasma was in the range 85.6-92.7%. The RSDs of intra-day and inter-day precision were both less than 12%. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of azasetron hydrochloride in rabbit plasma. 相似文献
8.
Lijuan Jing Kunjie Li Fen Qin Xintao Wang Li Pan Yanjuan Wang Maosheng Cheng Famei Li 《Journal of separation science》2012,35(20):2678-2684
A simple, sensitive, and rapid method for determination of L‐trantinterol in rat plasma was developed for the first time by using LC coupled to MS/MS based on chiral stationary phase. A baseline separation of the enantiomers of trantinterol was achieved on a Chirobiotic V column, using a mixture of acetonitrile–methanol–ammonia–acetic acid (80:20:0.01:0.02, v/v/v/v) as the mobile phase. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via ESI. The calibration curve was linear in concentration range from 0.270 to 108 ng/mL in plasma with the lower limit of quantification of 0.270 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 10.9% and the accuracy (relative error) was from 2.6 to 9.2% at all quality control levels. The method has been successfully applied to a study of L‐trantinterol pharmacokinetics in rats. 相似文献
9.
Oxana Yu. Kravtsova Sergey A. Paramonov Natalya I. Vasilevich Denis N. Kazyulkin Ekaterina Vlasova Michael Engsig 《Biomedical chromatography : BMC》2013,27(12):1609-1614
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
10.
Morini L Politi L Groppi A Stramesi C Polettini A 《Journal of mass spectrometry : JMS》2006,41(1):34-42
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg. 相似文献
11.
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L. 相似文献
12.
Rapid quantification of lisinopril in human plasma by liquid chromatography/tandem mass spectrometry
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers. 相似文献
13.
A quantitative method was developed for the determination of phosphatidylcholine (PC) species concentration using nanoflow LC-ESI-MS/MS. In this study, a calibration method is developed to determine the effect of PC carbon chain length on MS peak intensity. Using the multiple standard addition method, a relationship between the peak intensities of different PC species from nanoflow LC-MS and carbon chain length is established first using different injection amounts of PC standards. From this relationship, a calibration curve for each carbon chain length can be obtained for the concentration calculation. It was found that the MS peak area of PC species analyzed by nanoflow LC-MS linearly decreased with increased acyl carbon numbers, and that the effect of the degree of acyl chain unsaturation on MS peak intensity was minimized when the injection amount was maintained at less than 1 pmol. The method was applied for the quantitative calculation of 34 PC species from rat liver, which were identified from data-dependent MS/MS analysis during nanoflow LC separation. 相似文献
14.
Prasain JK Peng N Acosta E Moore R Arabshahi A Meezan E Barnes S Wyss JM 《Biomedical chromatography : BMC》2007,21(4):410-414
A highly sensitive and specific atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry method was developed for serum pharmacokinetic studies of puerarin in rats. Chromatography was carried out on a reversed-phase Phenomenex Synergi 4 microm Fusion-RP80 column (150 x 2.0 mm i.d.) using a mobile phase consisting of acetonitrile-water (10:90, v/v) in 10 mm NH(4)OAc with a flow rate of 0.2 mL/min. Puerarin was analyzed in the multiple reaction monitoring mode with a precursor/product ion transition of m/z 415/267. The method was demonstrated to be specific and sensitive, and a linear response was observed over a range of 2-5000 ng/mL in rat serum. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat serum after oral administration to spontaneously hypertensive rats. The blood concentration-time profile of puerarin showed a rapid initial increase, reaching a maximum and then declining within 1 h. Puerarin could not be detected after 24 h. The main pharmacokinetic parameters for puerarin after oral administration were as follows: C(max) (3.54 +/- 2.03 mg/L), T(max) (0.68 +/- 0.37 h), AUC(0-t) (7.29 +/- 3.79 mg h/L), AUC(0-infinity) (9.17 +/- 4.87 mg h/L), T(1/2) (1.7 +/- 0.6 h), CL/F (7.24 +/- 4.27 L/h/kg) and V/F (17.88 +/- 13.55 L/h/kg). 相似文献
15.
We established an analytical method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) in the precursor ion mode for simultaneous qualitative monitoring of various groups of cyanobacterial toxins. The toxin groups investigated were paralytic shellfish poisoning (PSP) toxins, anatoxins (ANAs), cylindrospermopsins (CYNs), microcystins (MCs), and nodularins (NODs), including rare and uncharacterized derivatives found in plankton and water matrices. Alternative analytical methods based on tandem mass spectrometry commonly operate in multiple reaction monitoring (MRM) mode and depend on prior knowledge of putative toxigenicity of the cyanobacterium species and strain, and the expected toxin variants. In contrast, the precursor ion mode yields diagnostic mass fragments for the detection of characteristic compounds of the different toxin classes and thus allows monitoring of a large set of unspecified cyanotoxins of various groups, even when the species composition is undetermined or uncertain. This rapid method enables screening for a wide spectrum of toxic cyanobacterial metabolites and degradation products in a single chromatographic separation with detection limits at nanogram levels. The precursor ion technique is a valuable adjunct to existing mass spectrometric methods for cyanotoxins, although it is not a complete replacement for detailed quantitative analysis requiring comprehensive sample cleanup. 相似文献
16.
Zhang J Rodila R Watson P Ji Q El-Shourbagy TA 《Biomedical chromatography : BMC》2007,21(10):1036-1044
Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration standards prepared in a tissue homogenate. This approach provides insufficient control of the homogenization process. In this paper, tissue quality control samples were introduced for the optimization of the homogenization process during method development, but also allowance for the performance evaluation of the entire analytical process. In addition, a new approach using rabbit blood as a homogenization medium was developed to stabilize sirolimus in rabbit tissue homogenates. Calibration standards and quality controls were prepared by spiking different sirolimus working solutions into rabbit blood. Homogenization quality control samples were prepared by injecting other sirolimus working solutions into empty test tubes and pre-cut arteries within pre-defined masses. A high-throughput homogenization procedure was optimized based on the specific chemical properties of sirolimus. The linear dynamic range was between 49.9 pg/mL and 31.9 ng/mL to accommodate the expected artery homogenate concentrations. Additionally, quality controls in rabbit blood were also used in the extraction to support the calibration standards. The accuracy and precision of the quality controls in rabbit blood reflect the extraction performance and the accuracy and precision of the homogenization tissue quality controls reflect the overall performance of the method. The mean bias was between -4.5 and 0.2% for all levels of quality controls in the blood and between 4.8 and 14.9% for all levels of the homogenization tissue quality controls. The CVs of all concentration levels were < or =5.3% for the quality controls in blood and < or =9.2% for the homogenization tissue quality controls. The method was successfully applied to determine the concentration of sirolimus in the rabbit arteries. 相似文献
17.
Jiping Huo Hongyun Wang Pei Hu Pingya Li Jinping Liu Ji Jiang 《Biomedical chromatography : BMC》2013,27(12):1701-1707
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC‐MS/MS) was developed for the determination of pseudo‐ginsenoside GQ in human plasma. Liquid–liquid extraction was used to isolate the analyte from biological matrix followed by injection of the extracts onto a C8 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer (API‐4000 system) in multiple reaction monitoring mode using negative electrospray ionization. The mobile phase consisted of methanol–10 mm ammonium acetate (90:10, v/v) and the flow rate was 0.3 mL/min. The method was validated over the concentration range of 5.0–5000.0 ng/mL for plasma. Inter‐ and intra‐day precisions (relative standard deviation) were all within 15% and the accuracy (relative error) was ≤9.4%. The lower limit of quantitation was 5.0 ng/mL. The pseudo‐ginsenoside GQ was stable after 8 h at room temperature, 24 h at autosampler and three freeze–thaw cycles (from ?30 to 25 °C). The method was successfully applied to the pharmacokinetic study of pseudo‐ginsenoside GQ in healthy Chinese volunteers. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
18.
A sensitive, specific and rapid liquid chromatography-mass spectrometry (LC-MS/MS) method has been developed and validated for enantioselective determination of darusentan enantiomers, orally active potent endothelin-A receptor antagonist, in rat plasma. The plasma samples were pretreated by protein precipitation with methanol and baseline chromatographic separation was performed on a Chiralcel OD-RH column with a mobile phase consisting of acetonitrile/water/formic acid (50:50:0.1, v/v/v) at a flow rate of 0.5 mL/min. The detection was accomplished by multiple-reaction monitoring (MRM) scanning via electrospray ionization (ESI) source operating in the negative ionization mode. The calibration curve was linear over the investigated concentration from 0.500 to 2500 ng/mL (r≥0.995) for each enantiomer using 50 μL of rat plasma. The lower limit of quantitation (LLOQ) for each enantiomer was 0.500 ng/mL. The intra- and inter-day precisions were not more than 10.2% and the accuracy was within the range from -5.4 to 6.3% for darusentan enantiomers. No chiral inversion was observed during the plasma preparation, storage and analysis. The method proved adequate for enantioselective pharmacokinetic studies of darusentan enantiomers after oral administration of three different doses of racemic darusentan. 相似文献
19.
Ling‐Zhi Wang Win‐Lwin Thuya Dorothy Su‐Lin Toh Michael George‐Limenta Lie Jie‐Ying Amelia Lau Li‐Ren Kong Seow‐Ching Wan Kian‐Ngiap Chua Edmund Jon‐Deoon Lee Boon‐Cher Goh 《Journal of mass spectrometry : JMS》2013,48(3):406-412
A sensitive analytical method has been developed and validated for the quantification of L‐ergothioneine in human plasma and erythrocytes by liquid chromatography‐tandem mass spectrometry. A commercially available isotope‐labeled L‐ergothioneine‐d9 is used as the internal standard. A simple protein precipitation with acetonitrile is utilized for bio‐sample preparation prior to analysis. Chromatographic separation of L‐ergothioneine is conducted using gradient elution on Alltime C18 (150 mm × 2.1 mm, 5 µ). The run time is 6 min at a constant flow rate of 0.45 ml/min. The mass spectrometer is operated under a positive electrospray ionization condition with multiple reaction monitoring mode. The mass transitions of L‐ergothioneine and L‐ergothioneine‐d9 are m/z 230 > 127 and m/z 239 > 127, respectively. Excellent linearity [coefficient of determination (r2) ≥ 0.9998] can be achieved for L‐ergothioneine quantification at the ranges of 10 to 10 000 ng/ml, with the intra‐day and inter‐day precisions at 0.9–3.9% and 1.3–5.7%, respectively, and the accuracies for all quality control samples between 94.5 and 101.0%. This validated analytical method is suitable for pharmacokinetic monitoring of L‐ergothioneine in human and erythrocytes. Based on the determination of bio‐samples from five healthy subjects, the mean concentrations of L‐ergothioneine in plasma and erythrocytes are 107.4 ± 20.5 ng/ml and 1285.0 ± 1363.0 ng/ml, respectively. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
20.
Yiming Liu Aihua Lin Zhifeng Wu Runmei Ou Haiding Huang 《Biomedical chromatography : BMC》2010,24(2):174-179
A sensitive, rapid and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the determination of aristolochic acid‐I (AA‐I) in rat plasma. Finasteride was used as the internal standard (IS). The analyte was separated on a Zorbax Eclipse XDB‐C18 column by isocratic elution with methanol‐10 mM ammonium acetate (75:25, v/v, pH = 7.3) at a flow rate of 0.25 mL/min, and analyzed by mass spectrometry in positive multiple reaction monitoring mode. The precursor‐to‐product ion transitions of m/z 359.0 → 298.2 and m/z 373.1 → 305.2 were used to detect AA‐I and IS, respectively. Good linearity was achieved over a range of 0.4–600 ng/mL. Intra‐ and inter‐day precisions measured as relative standard deviation were less than 13.5%, and accuracy ranged from 94.2 to 97.5%. The developed method was successfully applied in the pharmacokinetic study of AA‐I in rats. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献