首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) is a sensitive biomarker for DNA oxidative damage. However, its determination in human urine is confounded by trace level and complex matrix. In this study, a new configuration of on‐line solid phase microextraction coupled to high performance liquid chromatography‐ultraviolet detection was established with molecularly imprinted monolithic column as extraction sorbent. The tailor made monolith exhibited high extraction efficiency with the enrichment factor 101.84 for 8‐OHdG owing to its special porous structure and inherent selectivity. Under optimal condition, appreciable sensitivity had been achieved for this incorporation with limit of detection 2.04 nmol/L (S/N = 3) and limit of quantification 7.12 nmol/L (S/N = 10), respectively. Precise determination with wide range linearity (0.007–5.00 μmol/L) afforded a practical alternative in urinary 8‐OHdG analysis and 107 different subjects had been successfully analyzed. This newly developed method embodied useful prospect for the investigation of DNA oxidative damage with less expense, convenient maintenance and ease of operation  相似文献   

2.
A sensitive capillary electrophoretic method featuring spectrophotometric detection using a commercial Z‐cell was devised for the assay of 8‐hydroxy‐2′‐deoxyguanosine (8OHdG) in human urine. Solid‐phase extraction (SPE) based on hydrophilic‐lipophilic‐balanced RP sorbent was utilized for urine sample pretreatment and analyte preconcentration. The separation was carried out in conventional fused‐silica capillaries employing a Z‐cell with hydrodynamic sample injection (at 50 mbar for 12 s). The BGE (pH* 9.2, adjusted with 1 M NaOH) contained 0.15 M boric acid and 10% v/v ACN. The detection wavelength was 282 nm. The calibration curve for 8OHdG (measured in spiked urine) was linear in the range 10–1000 ng/mL; R2 = 0.9993. The LOD was 3 ng/mL (11 nmol/L) of 8OHdG. Determination of the 8OHdG urinary levels was possible even in healthy individuals.  相似文献   

3.
8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) is one of the major forms of oxidative DNA damage, and is commonly analyzed as an excellent marker of DNA lesions. The purpose of this study was to develop a sensitive method to accurately and rapidly quantify the 8‐OHdG by using CE‐LIF detection. The method involved the use of specific antibody to detect the DNA lesion (8‐OHdG) and consecutive fluorescence labeling. Next, urinary 8‐OHdG fluorescently labeled along with other constituents were resolved by capillary electrophoretic system and the lesion of interest was detected using a fluorescence detector. The limit of detection was 0.18 fmol, which proved sufficient sensitivity for detection and quantification of 8‐OHdG in untreated urine samples. The relative standard deviation was found to be 11.32% for migration time and 5.52% for peak area. To demonstrate the utility of this method, the urinary concentration of 8‐OHdG in an Alzheimer's transgenic mouse model was determined. Collectively, our results indicate that this methodology offers great advantages, such as high separation efficiency, good selectivity, low limit of detection, simplicity and low cost of analysis.  相似文献   

4.
8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) detection by high performance liquid chromatography (HPLC) with amperometric detection was studied using a Au electrode modified with different dendrimer based thin films. Gold electrode is thiol‐modified, forming self‐assembled monolayers on which different generation PAMAM dendrimers with terminal functional groups ? COOH and ? NH2 have been attached using peptidic bonds. Results obtained in synthetic samples show low limits of detection and quantification for 8‐OHdG (1.2×10?9 and 3.7×10?9 M respectively), with matrix interference elimination, thus avoiding sample pretreatment. Best results are obtained with electrodes modified with aliphatic amino thiols and 3.5 and 4.5 generation carboxylated dendrimers (Au/AET/DG3.5 and Au/AET/DG4.5), demonstrating that these materials constitute a good alternative for 8‐OHdG determination in biological fluids.  相似文献   

5.
A selective and reproducible off‐line solid‐phase microextraction procedure was developed for the simultaneous enantioselective determination of mirtazapine (MRT), demethylmirtazapine and 8‐hydroxymirtazapine in human urine. CE was used for optimization of the extraction procedure whereas LC‐MS was used for method validation and application. The influence of important factors in the solid‐phase microextraction efficiency is discussed, such as the fiber coatings, extraction time, pH, ionic strength, temperature and desorption time. Before extraction, human urine samples were submitted to enzymatic hydrolysis at 37°C for 16 h. Then, the enzyme was precipitated with trichloroacetic acid and the pH was adjusted to 8 with 1 mol/L pH 11 phosphate buffer solution. In the extraction, the analytes were transferred from the aqueous solution to the polydimethylsiloxane‐divinylbenzene fiber coating and then desorbed in methanol. The mean recoveries were 5.4, 1.7 and 1.0% for MRT, demethylmirtazapine and 8‐hydroxymirtazapine enantiomers, respectively. The method was linear over the concentration range of 62–1250 ng/mL. The within‐day and between‐day assay precision and accuracy were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic MRT to a healthy volunteer.  相似文献   

6.
Headspace solid‐phase microextraction is a solvent‐free sample preparation technique that is based on the equilibrium among a three‐phase system, i.e., sample‐headspace‐fiber. A compromise between sensitivity and extraction time is usually needed to optimize the sample throughput, especially when a large number of samples are analyzed, as usually the case in cross‐samples studies. This work explores the capability of multiple‐cumulative trapping solid‐phase microextraction on the characterization of the aroma profiling of olive oils, exploiting the automation capability of a novel headspace autosampler. It was shown that multiple‐cumulative solid‐phase microextraction has the potential to improve the overall sensitivity and burst the level of information for cross‐sample studies by using cumulative shorter extraction times.  相似文献   

7.
Triazine‐based organic polymers@SiO2 nanospheres were prepared and applied as an extraction coating onto stainless steel wires and the wires were filled into polyetheretherketone tube for in‐tube solid‐phase microextraction. Taking polycyclic aromatic hydrocarbons as targets, main factors affecting extraction performance of the tube were investigated through coupling to high performance liquid chromatography. Under the optimum conditions, an online analytical method for polycyclic aromatic hydrocarbons was established with large linear ranges (0.010‐20 µg/L), low limits of detection (0.003‐0.010 µg/L), high enrichment factors (533‐2954), and good repeatability (relative standard deviations <1.7% for intraday test, <5.0% for interday test). The analysis method was successfully applied to the detection of trace targets in real water samples and the relative recoveries ranged from 82.9 to 119.9%, which demonstrated the applicability of extraction tube in sample preparation.  相似文献   

8.
In this study, an in‐tube solid‐phase microextraction column packed with mesoporous TiO2 nanoparticles, coupled with MALDI–TOF–MS, was applied to the selective enrichment and detection of phosphopeptides in complex biological samples. The mesoporous TiO2 nanoparticles with high specific surface areas, prepared by a sol–gel and solvothermal method, were injected into the capillary using a slurry packing method with in situ polymerized monolithic segments as frits. Compared with the traditional solid‐phase extraction method, the TiO2‐packed column with an effective length of 1 cm exhibited excellent selectivity (α‐casein/β‐casein/BSA molar ratio of 1:1:100) and sensitivity (10 fmol of a β‐casein enzymatic hydrolysis sample) for the enrichment of phosphopeptides. These performance characteristics make this system suitable for the detection of phosphorylated peptides in practical biosamples, such as nonfat milk.  相似文献   

9.
Extraction of endogenous compounds and drugs and their corresponding metabolites from complex matrices, such as biofluids and solid tissues, requires adequate analytical approach facilitating qualitative and quantitative analysis. To this end, solid‐phase microextraction has been introduced as modern technology that is capable of efficient and high‐throughput extraction of compounds due to its ability to amalgamate sampling, extraction, and pre‐concentration steps, while requiring minimal use of organic solvents. The ability of solid‐phase microextraction to enable analyses on small‐volume biological samples and growing availability of biocompatible solid‐phase microextraction coatings make it a highly useful technology for variety of applications. For example, solid‐phase microextraction is particularly useful for identifying biomarkers in metabolomics studies, and it can be successfully applied in pharmaceutical and toxicological studies requiring the fast and sensitive determination of drug levels, especially those that are present at low levels in biological matrices such as plasma, urine, saliva, and hair. Moreover, solid‐phase microextraction can be directly applied in in vivo studies because this extraction technique is non‐exhaustive and its biocompatible probes offer minimal invasiveness to the analyzed system. In this article, we review recent progress in well‐established solid‐phase microextraction technique for in vitro and in vivo analyses of various metabolites and drugs in clinical, pharmaceutical, and toxicological applications.  相似文献   

10.
A temperature‐controlling device for in‐tube solid‐phase microextraction was developed based on thermoelectric cooling and heating. This device can control the temperature of the capillary column from 0 to 100°C by applying a voltage to a Peltier cooler or stainless steel tube. The extraction temperatures for angiotensin I, propranolol, and ranitidine were optimized. In all cases, setting the temperature to 10°C for extraction achieved the best extraction efficiency. Desorption showed minimum peak broadening at 70°C, contributing to better chromatographic performance. Propranolol was selected as a model compound to compare the performance of temperature‐controlled in‐tube solid‐phase microextraction at optimized conditions. Calibration curves exhibited good linearity (R2 > 0.999) over the studied range, and the limit of detection and limit of quantification were about three times lower than those obtained at standard conditions (30°C extraction and desorption).  相似文献   

11.
In this study, a platinum wire coated with poly(3,4‐ethylenedioxythiophen) was used as an electro‐assisted solid‐phase microextraction fiber for the quantification of tricyclic antidepressant drugs in biological samples by coupling to GC employing a flame ionization detector. In this study, an electric field increased the extraction rate and recovery. The fiber used as a solid phase was synthesized by the electropolymerization of 3,4‐ethylenedioxythiophen monomers onto a platinum wire. The ability of this fiber to extract imipramine, desipramine, and clomipramine by using the electro‐assisted solid‐phase microextraction technique was evaluated. The effect of various parameters that influence the extraction efficiency, which include solution temperature, extraction time, stirring rate, ionic strength, time and temperature of desorption, and thickness of the fiber, was optimized. Under optimized conditions, the linear ranges and regression coefficients of calibration curves were in the range of 0.5–250 and 0.990–0.998 ng/mL, respectively. Detection limits were in the range of 0.15–0.45 ng/mL. Finally, this method was applied to the determination of drugs in urine and wastewater samples and recoveries were 4.8–108.9%.  相似文献   

12.
In this work, zinc oxide/polypyrrole nanocomposite coating was fabricated on stainless steel and evaluated as a novel headspace solid‐phase microextraction fiber coating for extraction of ultra‐trace amounts of environmental pollutants, namely, phthalate esters, in water samples. The fiber nanocomposite were prepared by a two‐step process including the electrochemical deposition of polypyrrole on the surface of stainless steel in the first step, and electrochemical deposition of zinc oxide nanosheets in the second step. Porous structure together with zinc oxide nanosheets with the average diameter of 30 nm were observed on the surface by using scanning electron microscopy. The effective parameters on extraction of phthalate esters (i.e., extraction temperature, extraction time, desorption temperature, desorption time, salt concentration, and stirring rate) were investigated and optimized by one‐variable‐at‐a‐time method. Under optimized conditions (extraction temperature, 90°C; extraction time, 40 min; desorption temperature, 270°C; desorption time, 5 min; salt concentration, 25% w/v; and stirring rate, 1000 rpm), the limits of detection were in the range of 0.05–0.8 μg/L, and the repeatability and fiber‐to‐fiber reproducibility were in the ranges of 6.1–7.3% and 8.7–10.2%, respectively.  相似文献   

13.
In this study, a novel technique is proposed for preparation of an efficient and unbreakable metal‐wire‐supported solid‐phase microextraction fiber. A sol–gel film was deposited on electrophoretically deposited carbon nanotubes on a stainless‐steel wire. The applicability of the fiber was evaluated through the extraction of some aromatic pollutants as model compounds from the headspace of aqueous samples in combination with gas chromatography and mass spectrometry. The parameters affecting the structure and extraction efficiency of the fiber (including the type of solvent, time, and potential for electrophoretic deposition) and the parameters affecting the extraction efficiency (such as coating type, salt content, extraction temperature, and time) were investigated. The results showed that the film thickness will be increased by increasing the potential and time duration. Finally, the characterization of the deposited film was accomplished by scanning electron microscopy and thermogravimetric analysis. After the optimization of the extraction parameters, the limit of detection of less than 20 pg/mL was achieved, and the calibration curves were all linear (r 2 ≥ 0.9737), in the range from 50 to 500 pg/mL. The solid‐phase microextraction fiber has a high mechanical strength; good stability and long service life, making it potentially applicable in the extraction of trace polycyclic aromatic hydrocarbons from aqueous samples.  相似文献   

14.
Solid‐phase microextraction (SPME) has been directly coupled to an ion‐trap mass spectrometer (MS) for the determination of the model compound lidocaine in urine, hereby applying MS/MS [fragmentation of [M + H]+ (m/z 235) to a fragment with m/z 86]. The throughput of samples has been increased using non‐equilibrium SPME with polydimethylsiloxane (PDMS) fibers. The effect of temperature on the sorption and the desorption was studied. Elevated temperatures during sorption (65°C) and desorption (55°C) had a considerable influence on the speed of the extraction. The desorption was carried out with a home‐made desorption chamber allowing thermostating. Only 1 min sorption and 1 min desorption were performed, after which MS detection took place, resulting in a total analysis time of 3 min. Detection limits below 1 ng/mL could be obtained despite yields of only 2.1 and 1.5% for a 100‐ and a 30‐μm PDMS‐coated fiber, respectively. Furthermore, the determination of lidocaine in urine had acceptable reproducibilities, i.e., relative standard deviations (RSDs) below 10%. A limit of quantitation (RSD < 15%) of about 1 ng/mL was obtained. No extra wash step of the extraction fiber was required after desorption if a 30‐μm coating was used, whereas not all the analyte was desorbed from the 100‐μm coating in a single desorption. Therefore, the SPME‐MS/MS system with a 30‐μm PDMS‐coated fiber for rapid non‐equilibrium SPME at elevated temperatures has interesting potential for high‐throughput analysis of biological samples.  相似文献   

15.
Glycosides are a kind of highly important natural aromatic precursors in tobacco leaves. In this study, a novel HKUST‐1‐coated monolith dip‐it sampler was designed for the fast and sensitive analysis of trace glycosides using direct analysis in real‐time mass spectrometry. This device was prepared in two steps: in situ polymerization of monolith in a glass capillary of dip‐it and layer‐by‐layer growth of HKUST‐1 on the surface of monolith. Sufficient extraction was realized by immersing the tip to solution and in situ desorption was carried out by plasma direct analysis in real time. Compared with traditional solid‐phase microextraction protocols, sample desorption was not needed anymore, and only extraction conditions were needed to be optimized in this method, including the gas temperature of direct analysis in real time, extraction time, and CH3COONH4 additive concentration. This method enabled the simultaneous detection of six kinds of glycosides with the limits of detection of 0.02–0.05 μg/mL and the linear ranges covering two orders of magnitude with the limits of quantitation of 0.05–0.1 μg/mL. Moreover, the developed method was applied for the glycosides analysis of three tobacco samples, which only took about 2 s for every sample.  相似文献   

16.
The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid‐phase microextraction with liquid desorption followed by high‐performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β‐estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid‐phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027–0.12 μg/L. The linear range was 0.10–200 μg/L for 17β‐estradiol, 0.25–200 μg/L estriol, ethinylestradiol and estrone, and 0.50–200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54‐ to 74‐fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%.  相似文献   

17.
<正>Urinary 8-hydroxy-2'-deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with convective mass transfer and inherent selectivity,the MIP monolithic column exhibited high extraction efficiency on target analyte with the limit of detection(LOD) and quantity(LOQ) reached 2.6 nmol/L(S/N = 3) and 8.6 nmol/L(S/N= 10),respectively.The linear range was from 10 nmol/L to 1.5μmol/L(r = 0.9999) with relative standard deviation(RSD) 3.7%for peak current,and 0.5%for migration time,and the average recovery of spiked 20-200 nmol/L 8-OHdG was 85%±3.5%(n = 6).This highly sensitive method was applied to analysis of 8-OHdG in urinary samples from healthy volunteers,coking plant workers and lung cancer patients.  相似文献   

18.
The use of solid‐phase microextraction coatings based on gold nanoparticles was investigated, focusing the attention on the preparation of nanoparticles with nonclassical reduction agents of HAuCl4 such as gallic acid and H2O2, rather than the conventional sodium citrate. All nanoparticles were characterized by diode array spectroscopy, whereas novel nanoparticles prepared with gallic acid and H2O2 were also characterized by microscopic techniques. Solid‐phase microextraction coatings were prepared with a layer‐by‐layer approach. Gallic acid permitted the preparation of stable nanoparticles with milder experimental conditions (1 min, room temperature) and provided the most uniform coatings (thickness ∼3 μm). Seven organochlorine pesticides were determined in different environmental waters using gas chromatography with electron capture detection. Despite the low thickness of the coatings, limits of detection of the entire method down to 0.13 μg/L were obtained. A comparison with the commercial polyacrylate in terms of the partition coefficients of the analytes to the coatings gave logarithm of the partition coefficient values two times higher with gallic acid than polyacrylate (although the commercial fiber is 28 times thicker). Interfiber relative standard deviation values ranged from 8.67 to 21.3%. Optimum fibers also presented an adequate lifetime (>100 extractions).  相似文献   

19.
Recently the connection between oxidative stress and various diseases, including cancer and Alzheimer's, attracts notice as a pathway suitable for diagnostic purposes. 8‐Oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine produced from the interaction of reactive oxygen species with DNA become prominent as biomarkers. Several methods have been developed for their determination in biofluids, including solid‐phase extraction and enzyme‐linked immunosorbent assays. However, still, there is a need for reliable and fast analytical methods. In this context, solid‐phase microextraction offers many advantages such as flexibility in geometry and applicable sample volume, as well as high adaptability to high‐throughput sampling. In this study, a solid‐phase microextraction method was developed for the determination of 8‐oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine in biofluids. The extractive phase of solid‐phase microextraction consisted of hydrophilic–lipophilic balanced polymeric particles. In order to develop a solid‐phase microextraction method suitable for the determination of the analytes in saliva and urine, several parameters, including desorption solvent, desorption time, sample pH, and ionic strength, were scrutinized. Analytical figures of merit indicated that the developed method provides reasonable interday and intraday precisions (<15% in both biofluids) with acceptable accuracy. The method provides a limit of quantification for both biomarkers at 5.0 and 10.0 ng/mL levels in saliva and urine matrices, respectively.  相似文献   

20.
An analytical method based on online combination of polymer monolith microextraction (PMME) technique with hydrophilic interaction LC (HILIC)/MS is presented. The extraction was performed with a poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic column while the subsequent separation was carried out on a Luna silica column by HILIC. After 1:1 v/v dilution with 20 mM phosphate solution at pH 7.0 and centrifugation, urine sample was directly used for extraction. After optimization, 85% ACN (containing 0.3% formic acid v/v) was used for rapid online elution, which was also the mobile phase in HILIC to avoid band broadening during separation or carry‐over that was usually observed in PMME‐RP LC system. Online automation of extraction and separation procedures was realized under the control of a program in this study. The developed method was applied to rapid and sensitive monitoring of three β2‐agonist traces in human urine. The LODs (S/N = 3) of the method were found to be 0.05–0.09 ng/mL of β2‐agonists in urine. The recoveries of three β2‐agonists spiked in five different urine samples ranged from 79.8 to 119.8%, with RSDs less than 18.0%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号