首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Sample preparation is often necessary to separate and concentrate various compounds prior to analysis of complex samples. In this regard, isoelectric focusing (IEF) is one of the best sample preparation methods. With this approach, however, carrier ampholytes have to be introduced into the samples, which may result in matrix interferences. In this paper, a simple ampholyte-free IEF free-flow electrophoresis design was developed for the separation of proteins. beta-Lactoglobulin, hemoglobin, myoglobin and cytochrome c were selected as model analytes. The experimental design took advantage of the electrolysis-driven production of H(+) and OH(-) ions that migrated from the anode and cathode, respectively, establishing a pH gradient spanning from 2.3 to 8.9. The separation chamber was filled with silanized glass beads as a support medium. Dialysis membranes were mounted at the two sides of the separation chamber (made of glass slides) and sealed with 2% agarose gel. The separated proteins drained from the outlets of the separation chamber and could be successfully collected into small glass tubes. The focusing process was visually observed and the separation was confirmed by capillary isoelectric focusing (cIEF) with pI markers.  相似文献   

2.
Stastná M  Slais K 《Electrophoresis》2005,26(18):3586-3591
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.  相似文献   

3.
Immunoglobulins in bovine colostrum were separated and fractionated from other proteins using the method and instrumentation developed in our laboratory. The proposed separation was based on bidirectional isotachophoresis/moving boundary electrophoresis with electrofocusing of the analytes in a pH gradient from 3.9 to 10.1. The preparative instrumentation included the trapezoidal non-woven fabric that served as separation space with divergent continuous flow. The defatted and casein precipitate-free colostrum supernatant was loaded directly into the instrument without any additional colostrum pre-preparation. Immunoglobulin G was fractionated from other immune proteins such as bovine serum albumin, β-lactoglobulin, and α-lactalbumin, and was continuously collected in separated fractions over 3 h. The fractions were further processed, and isolated immunoglobulin G in the liquid fractions was confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and by re-focusing in gel isoelectric focusing. Separated immunoglobulin G was detected in seven fractions by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with a gradually decreased concentration in the fractions. Re-focusing of the proteins in the fractions by gel isoelectric focusing revealed multiple separated zones of immunoglobulin G with the isoelectric point values covering the range from 5.4 to 7.2. Each fraction contained distinct zones with gradually increased isoelectric point values and decreased concentrations from fraction to fraction.  相似文献   

4.
Researchers frequently use two‐dimensional polyacrylamide gel electrophoresis (2D‐PAGE) prior to mass spectrometric analysis in a proteomics approach. The i2D‐PAGE method, which ‘inverts’ the dimension of protein separation of the conventional 2D‐PAGE, is presented in this publication. Protein lysate of Channa striata, a freshwater snakehead fish, was separated based on its molecular weight in the first dimension and its isoelectric point in the second dimension. The first‐dimension separation was conducted on a gel‐free separation device, and the protein mixture was fractionated into 12 fractions in chronological order of increasing molecular weight. The second‐dimension separation featured isoelectric focusing, which further separated the proteins within the same fraction according to their respective isoelectric point. Advantages of i2D‐PAGE include better visualisation of the isolated protein, easy identification on protein isoforms, shorter running time, customisability and reproducibility. Erythropoietin standard was applied to i2D‐PAGE to show its effectiveness for separating protein isoforms. Various staining methods such as Coomassie blue staining and silver staining are also applicable to i2D‐PAGE. Overall, the i2D‐PAGE separation method effectively separates protein lysate and is suitable for application in proteomics research.  相似文献   

5.
CIEF was developed for the rapid analysis of charge heterogeneity of trastuzumab biosimilar using commercially available fluorocarbon‐coated capillary. The CIEF master mix was composed of 0.30% w/v methyl cellulose, 2.3 M urea, 56.8 mM l ‐arginine, 1.52 mM iminodiacetic acid, 4.5% v/v carrier ampholytes (broad‐range pI 3–10 and narrow‐range pI 8–10.5 with ratio of 3:1), and 0.45% v/v 10.0, 9.5, 7.0, 5.5, 4.1 pI markers. To get a robust method to analyze charge heterogeneity, some separation parameters, including focusing time and separation temperature, were investigated and optimized. The optimized method gave good precision in estimated pI values of charge variants with RSDs of not more than 0.16% intraday analysis (n = 6) and < 0.18% interday analysis (n = 9). In addition, the applications of this method including purity, stability, lot consistency, peptide N‐glycosidase F digest, and C‐terminal lysine variants characterization were also investigated.  相似文献   

6.
Counterflow gradient electrofocusing uses the bulk flow of a liquid solution to counterbalance the electrophoretic migration of an analyte. When either the bulk velocity or the electrophoretic velocity of the analyte is made to vary across the length of the channel, there exists a unique zero‐velocity point for the analyte. This focusing method enables simultaneous separation and concentration of different analytes. The high resolution and sensitivity achieved are similar to that of isoelectric focusing, which separates analytes based on their isoelectric points, but the key difference is that analytes will instead focus based on their electrophoretic mobility. Dynamically changing the applied voltage or the counterflow rate over time will shift the zero‐velocity point, and therefore allows the focused analytes to pass through a fixed detection point, or elute from the separation channel. Throughout the review, a number of different counterflow gradient techniques will be discussed, along with their recent advancements and potential applications.  相似文献   

7.
A method for two-dimensional electrophoretic separation of myelin proteins is presented. The first dimension consists of isoelectric focusing of lyophilized and delipidated membrane proteins, solubilized in a mixture of the nonionic detergent Triton X-100, the zwitterionic detergent CHAPS, 9 M urea and carrier ampholytes, and incorporated into a slab gel before separation. Subsequent discontinuous sodium dodecyl sulfate-polyacrylamide gel electrophoresis was performed by moulding the isoelectric focusing slab gel with its supporting glass plate into the stacking gel. This method proved to give highly reproducible results since mechanical forces and thus the risk of stretching, folding or rupture of the isoelectric focusing slab gel is minimized. Furthermore, by immunoblotting, the positions of myelin-associated glycoprotein and 2',3'-cyclic nucleotide 3'-phosphodiesterase were established with specific antibodies.  相似文献   

8.
Cases of poisoning by p‐phenylenediamine (PPD) are detected sporadically. Recently an article on the development and validation of an LC–MS/MS method for the detection of PPD and its metabolites, N‐acetyl‐p‐phenylenediamine (MAPPD) and N,N‐diacetyl‐p‐phenylenediamine (DAPPD) in blood was published. In the current study this method for detection of these compounds was validated and applied to urine samples. The analytes were extracted from urine samples with methylene chloride and ammonium hydroxide as alkaline medium. Detection was performed by LC–MS/MS using electrospray positive ionization under multiple reaction‐monitoring mode. Calibration curves were linear in the range 5–2000 ng/mL for all analytes. Intra‐ and inter‐assay imprecisions were within 1.58–9.52 and 5.43–9.45%, respectively, for PPD, MAPPD and DAPPD. Inter‐assay accuracies were within ?7.43 and 7.36 for all compounds. The lower limit of quantification was 5 ng/mL for all analytes. The method, which complies with the validation criteria, was successfully applied to the analysis of PPD, MAPPD and DAPPD in human urine samples collected from clinical and postmortem cases.  相似文献   

9.
Retention and enantioseparation behavior of ten 2,2′‐disubstituted or 2,3,2′‐trisubstituted 1,1′‐binaphthyls and 8,3′‐disubstituted 1,2′‐binaphthyls, which are used as catalysts in asymmetric synthesis, was investigated on eight chiral stationary phases (CSPs) based on β‐CD, polysaccharides (tris(3,5‐dimethylphenylcarbamate) cellulose or amylose CSPs) and new synthetic polymers (trans‐1,2‐diamino‐cyclohexane, trans‐1,2‐diphenylethylenediamine and trans‐9,10‐dihydro‐9,10‐ethanoanthracene‐(11S,12S)‐11,12‐dicarboxylic acid CSPs). Normal‐, reversed‐phase and polar‐organic separation modes were employed. The effect of the mobile phase composition was examined. The enantiomeric separation of binaphthyl derivatives, which possess quite similar structures, was possible in different enantioselective environments. The substituents and their positions on the binaphthyl skeleton affect their properties and, as a consequence, the separation system suitable for their enantioseparation. In general, the presence of ionizable groups on the binaphthyl skeleton, substitution with non‐identical groups and a chiral axis in the 1,2′ position had the greatest impact on the enantiomeric discrimination. The 8,3′‐disubstituted 1,2′‐binaphthyl derivatives were the most easily separated compounds in several separation systems. From all the chiral stationary phases tested, cellulose‐based columns were shown to be the most convenient for enantioseparation of the studied analytes. However, the polymeric CSPs with their complementary behavior provided good enantioselective environments for some derivatives that could be hardly separated in any other chromatographic system.  相似文献   

10.
Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8‐fold.  相似文献   

11.
We developed a straightforward, robust, and relatively fast method for the analysis of amino acids by mixed‐mode high‐performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The method does not involve derivatization and allows the detection of 21 amino acids, representing a wide range of isoelectric points, in less than 40 min. Chromatographic separation was governed by a silica‐based mixed‐mode column providing simultaneous hydrophobic and ion exchange separation mechanisms. The use of tandem mass spectrometry increased selectivity, reducing potential problems associated with poor selectivity in the chromatographic system. For an injection volume of 1 μL, we obtained detection limits <3 μM for the majority of analytes. For all analytes, a linearity of r > 0.99 was obtained, recovery in matrix was >86%, and the retention times were highly reproducible. The method was successfully applied to soil solution and fungal culture samples, demonstrating the advantages in successfully avoiding issues associated with high amounts of substances that may interfere with derivatization‐based methods. This method represents an alternative to derivatization‐based methods and can be applied in areas where sample matrices are highly complex.  相似文献   

12.
During bacterial infections of the central nervous system the number of microorganisms in the cerebrospinal fluid is often ranging from few up to hundreds of cells per milliliter. The electrophoretic techniques with the UV-detection reach a detection limit for whole cells of approximately 107 cells per milliliter. The coupling of the filtration cartridge with capillary isoelectric focusing can improve the detection limit by four orders of magnitude. In order to improve the detection limit the red non-ionogenic surfactant 1-[[4-(phenylazo)phenyl]azo]-2-hydroxy-3-naphthoic acid polyethylene glycol ester, PAPAN 1000, has been prepared and used for the dynamic labeling of analytes before filtration of the sample with a concentration modulation in the analysis of proteins or microorganisms. Values of isoelectric points of labeled analytes have been calculated using pI markers detectable at 515 nm and have been found comparable with pI of the native compounds. Minimum detectable amounts of proteins and microorganisms were lower than nanograms and a hundred labeled cells, respectively. The introduced method, coupling of the filtration cerebrospinal fluid spiked with microorganisms and labeled by PAPAN, facilitates their rapid CIEF separation in the pH gradient pH range of 2–5 at their clinically important level 101 to 102 cells per milliliter.  相似文献   

13.
The dynamics of gel isoelectric focusing were studied by using amphoteric low-molecular-mass colored substances (isoelectric point markers). The polyacrylamide gel in slab format was in direct contact with the electrodes. In addition to isoelectric focusing with a pH gradient composed of synthetic carrier ampholytes, pH gradients created by simple buffers of acetic acid, 2-(N-morpholino)ethanesulfonic acid, histidine and N,N,N',N'-tetramethylethylenediamine were applied. The progress of the electrofocusing process was monitored by a charge-coupled device camera and video recording. The gradient profile and dynamics were approximated from the positions of isoelectric point markers, which were focused both on boundaries between individual zones of simple buffers and within the zones themselves. The obtained animated records enabled the observation of the entire real focusing run within fractions of a minute, which is useful both for the understanding and optimization of the focusing.  相似文献   

14.
Proteins extracted from gluten of the bread wheat cultivar Fiorello 2 in the presence of 2-mercaptoethanol or dithiothreitol were separated by isoelectric focusing in a free solution in a pH 3-10 gradient containing 50% v/v 1-propanol or urea. The collected fractions were analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in 10% gels (high and medium molecular weight glutenin subunits) and 16% gels (low molecular weight gliadins). The isoelectric focusing pattern of gluten polypeptides in 50% v/v 1-propanol was comparable to that obtained on two-dimensional gel electrophoresis, based on isoelectric focusing and polyacrylamide gel electrophoresis or nonequilibrium pH gradient electrophoresis and polyacrylamide gel electrophoresis. A similar isoelectric focusing pattern was also observed when 3M urea was used as solvent. New gluten polypeptides, similar in mobility to the high molecular weight subunits of glutenin were detected at acidic pH.  相似文献   

15.
Rapid (<5 min) high-performance isoelectric focusing was performed in uncoated fused-silica capillaries to resolve isoforms of monoclonal antibodies and to determine their isoelectric points (pI). The methodology involved the use of a 32 cm (effective length 9 cm)×50 μm I.D. uncoated capillary. (Hydroxypropyl)methyl cellulose was used as an additive to suppress analyte–wall interaction and to precisely control electroosmotic flow so that focusing and mobilization of focused zones past detector occur simultaneously. Urea was included in the separation medium to solubilize the antibodies that precipitated at their point of focusing. The methods with and without urea used ampholytes pH 5–8 to generate a demonstrable linear gradient between pH 5.4 and pH 7.2, based on the separation of various protein standards. Reproducibility [<2% (R.S.D.)] of the migration times (corresponding to the detectable isoforms of the antibodies) was obtained by using two sets of reagents and capillaries on three consecutive days. pI values determined from day-to-day with a reference standard were shown to vary by only 0.01 pH unit. The described capillary isoelectric focusing methods provided a rapid, simple and reproducible way of monitoring micro-heterogeneity and pI of the murine monoclonal antibodies investigated.  相似文献   

16.
Isoelectric focusing plays a critical role in the analysis of complex protein samples. Conventionally, isoelectric focusing is implemented with carrier ampholytes in capillary or immobilized pH gradient gel. In this study, we successfully exhibited a carrier ampholyte‐free isoelectric focusing on paper‐based analytical device. Proof of the concept was visually demonstrated with color model proteins. Experimental results showed that not only a pH gradient was well established along the open paper fluidic channel as confirmed by pH indicator strip, the pH gradient range could also be tuned by the catholyte or anolyte. Furthermore, the isoelectric focusing fractions from the paper channel can be directly cut and recovered into solutions for post analysis with sodium dodecyl sulfate‐polyacrylamide gel electrophoresis and matrix‐assisted laser desorption/ionization‐time‐of‐flight mass spectrometry. This paper‐based isoelectric focusing method is fast, cheap, simple and easy to operate, and could potentially be used as a cost‐effective protein sample clean‐up method for target protein analysis with mass spectrometry.  相似文献   

17.
A new β‐CD derivative, heptakis [2,6‐di‐O‐pentyl‐3‐O‐(4′‐chloro‐5′‐pyridylmethyl)]‐β‐CD, was synthesized by the selective introduction of a pyridyl group on the 3‐positions of β‐CD. The chromatographic properties of the pyridyl β‐CD derivative were studied by using it as the stationary phase in capillary GC. The polarity of the prepared stationary phase was moderate, and the separation results demonstrated that the prepared stationary phase possessed excellent separation ability and chiral recognition for a wide range of analytes. Not only the aromatic positional isomers, such as o‐, m‐, p‐xylene and α‐, β‐naphthol isomers, but also some compounds with multi‐stereogenic centers, such as n‐(1‐methylpropyl)‐3‐(2,2‐dichloroethenyl)‐2,2‐dimethylcyclopropanecarboxamide and n‐(1‐methylpropyl)‐3‐(2‐chloro‐3,3,3‐trifluoropropenyl)‐2,2‐dimethylcyclopropanecarboxamide with three stereogenic centers including eight configurational isomers, were successfully separated. The results also indicated that the polarity of the β‐CD derivative, and the hydrogen bonding between the β‐CD derivative, and the analytes had a very important effect on separation.  相似文献   

18.
A novel metal aquo‐ion affinity chromatography has been developed for the analysis of basic compounds using heat‐treated silica gel containing hydrated metal cations (metal aquo‐ions) as the packing material. The packing materials of the metal aquo‐ion affinity chromatography were prepared by the immobilization of a single metal component such as Fe(III), Al(III), Ag(I), and Ni(II) on silica gel followed by extensive heat treatment. The immobilized metals form aquo‐ions to present cation‐exchange ability for basic analytes and the cation‐exchange ability for basic analytes depends on pKa of the immobilized metal species. In the present study, to evaluate the retention characteristics of metal aquo‐ion affinity chromatography, the on‐line solid‐phase extraction of drugs was investigated. Obtained data clearly evidence the selective retention capability of metal aquo‐ion affinity chromatography for basic analytes with sufficient capacity.  相似文献   

19.
A fluorescence detection system for capillary liquid separation methods is described. The system is based on a silica capillary coated with a low refractive index fluoropolymer Teflon AF that serves both as a separation channel and as a liquid core waveguide (LCW). A fibre-coupled laser excites separated analytes in a detection point and arising fluorescence is collected at one end of the LCW capillary into the other optical fibre which brings it to a compact charge-coupled device (CCD) array spectrometer installed in a desktop computer. No additional components such as focusing optics or filters are necessary. This system was used for detecting isoelectrically focused fluorescent low-molecular-mass pI (isoelectric point) markers and fluorescein isothiocyanate (FITC) labelled proteins. The ability of the system to acquire fluorescent spectra is also demonstrated.  相似文献   

20.
The inhibition of the α‐glucosidase enzyme plays an important role in the treatment of diabetes mellitus. We have established a highly sensitive, fast, and convenient CE method for the characterization of the enzyme and inhibition studies of α‐glucosidase inhibitors. The separation conditions were optimized; the pH value and concentration of the borate‐based separation buffer were optimized in order to achieve baseline separation of p‐nitrophenyl‐α‐d ‐glucopyranoside and p‐nitrophenolate. The optimized method using 25 mM tetraborate buffer, pH 9.5, was evaluated in terms of repeatability, LOD, LOQ, and linearity. The LOD and LOQ were 0.32 and 1.32 μM for p‐nitrophenyl‐α‐d ‐glucopyranoside and 0.83 and 3.42 μM for p‐nitrophenolate, respectively. The value of the Michaelis–Menten constant (Km) determined for the enzyme is 0.61 mM, which is in good agreement with the reported data. The RSDs (n = 6) for the migration time was 0.67 and 1.83% for substrate and product, respectively. In the newly established CE method, the separation of the reaction analytes was completed in <4 min. The developed CE method is rapid and simple for measuring enzyme kinetics and for assaying inhibitors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号