首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Carnation‐like CuO hierarchical nanostructures assembled by ultrathin porous nanosheets were successfully fabricated via a facile solvothermal route followed with heat treatment. As‐prepared CuO nanostructures exhibited excellent catalytic activity toward glucose oxidation in the absence of any enzymes. Under the optimized conditions, the CuO‐based enzymeless glucose sensor showed high sensitivity of 3.15 mA mM?1 cm?2, low limit of detection (98 nM, S/N=3), good reproducibility, excellent selectivity and long‐time stability. The superb nonenzymatic glucose sensing performance of the CuO hierarchical nanostructures was attributed to the highly catalytically active sites at the edges and basal planes of the CuO nanosheets, facile transportation of analytes through the abundant mesopores and macropores, robust and stable hierarchical structure. Moreover, the CuO‐based enzymeless glucose sensor showed high accuracy and reliability in comparison with clinical glucometer for quantitative determination of glucose in human blood serum samples.  相似文献   

2.
An amperometric immunosensor for IgG was developed by covalently immobilizing anti‐IgG on multiwall carbon nanotube‐embedded conducting polymer, poly‐5,2′ : 5′′,2′′‐terthiophene‐3′‐carboxylic acid (MWCNT/pTTCA). The MWCNT/pTTCA modified electrode was characterized by SEM, EIS, and XPS. A hydrazine‐labeled secondary antibody‐MWCNT conjugate (Hyd‐MWCNT‐Ab2) was applied for detection. Hydrazine was used as a catalyst for the reduction of hydrogen peroxide, which was monitored at ?0.3 V vs. Ag/AgCl. The calibration plots showed a linear range of 0.1–10 ng/mL with a detection limit of 0.084±0.004 ng/mL. The proposed immunosensor was evaluated for clinical applications in a rabbit serum sample.  相似文献   

3.
The crystal‐plane effect of ZnO nanostructures on the toxic 2‐chlorophenol gas‐sensing properties was examined. Three kinds of single‐crystalline ZnO nanostructures including nanoawls, nanorods, and nanodisks were synthesized by using different capping agents via simple hydrothermal routes. Different crystal surfaces were expected for these ZnO nanostructures. The sensing tests results showed that ZnO nanodisks exhibited the greatest sensitivity for the detection of toxic 2‐chlorophenol. The results revealed that the sensitivity of these ZnO samples was heavily dependent on their exposed surfaces. The polar (0001) planes were most reactive and could be considered as the critical factor for the gas‐sensing performance. In addition, calculations using density functional theory were employed to simulate the gas‐sensing reaction involving surface reconstruction and charge transfer both of which result in the change of electronic conductance of ZnO.  相似文献   

4.
A slow reaction process has been successfully used to synthesize Prussian blue/single‐walled carbon nanotubes (PB/SWNTs) nanocomposites. Electrochemical and surface characterization by cyclic voltammetry (CV), scanning electron microscopy (SEM), transmission electron microscopy (TEM), UV‐vis absorption spectroscopy, Fourier transform infrared (FTIR) spectroscopy and X‐ray diffraction (XRD) confirmed the presence of PB nanocrystallites on SWNTs. PB/SWNTs modified glassy carbon electrode (GCE) exhibits efficient electron transfer ability and high electrochemical response towards hydrazine. The fabricated hydrazine sensor showed a wide linear range of 2.0×10?6–6.0×10?3 M with a response time less than 4 s and a detection limit of 0.5 μM. PB/SWNTs modified electrochemical sensors are promising candidates for cost‐effective in the hydrazine assays.  相似文献   

5.
While single‐molecule sensing offers the ultimate detection limit, its throughput is often restricted as sensing events are carried out one at a time in most cases. 2D and 3D DNA origami nanostructures are used as expanded single‐molecule platforms in a new mechanochemical sensing strategy. As a proof of concept, six sensing probes are incorporated in a 7‐tile DNA origami nanoassembly, wherein binding of a target molecule to any of these probes leads to mechanochemical rearrangement of the origami nanostructure, which is monitored in real time by optical tweezers. Using these platforms, 10 pM platelet‐derived growth factor (PDGF) are detected within 10 minutes, while demonstrating multiplex sensing of the PDGF and a target DNA in the same solution. By tapping into the rapid development of versatile DNA origami nanostructures, this mechanochemical platform is anticipated to offer a long sought solution for single‐molecule sensing with improved throughput.  相似文献   

6.
《Electroanalysis》2004,16(10):827-831
An amperometric detector for hydrophobic ions based on a plasticized poly(vinyl) chloride (PVC) membrane incorporated in a flow‐injection system was developed. A four‐electrode potentiostat with ohmic drop compensation was used, while a flow‐through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. When the influence of the applied potential and of the flow‐injection variables on the determination of tetrabutylammonium was studied, a linear relationship was observed between current peak height and ion concentration over a range of 5×10?6–6×10?5 M tetrabutylammonium. Good repeatability and between‐day reproducibility and high sample frequency were obtained. The effect of other ions was studied. Two different amperometric methods, indirect and direct, were also developed for the determination of dodecylsulfate in the concentration range 3×10?5–9×10?4 M.  相似文献   

7.
In this study, we have investigated the effect of counter anions on the morphology of cobalt oxide nanostructures. The nanostructures of cobalt oxide are prepared by a low temperature aqueous chemical growth method. The morphology of cobalt oxide nanostructure material was investigated by scanning electron microscopy and the crystalline structure was studied by powder X‐ray diffraction technique. The cobalt oxide nanostructures exhibit the nanowire, lump, bundle of the nanowire and flower‐like morphologies. The XRD study has revealed a cubic phase of cobalt oxide nanostructures. The electro‐catalytic properties of cobalt oxide nanostructures were explored through cyclic voltammetry and amperometric techniques by sensing of lactic acid in the alkaline media. The cobalt oxide nanostructures prepared from cobalt nitrate have shown a well‐resolved redox peak. The proposed mechanism for the non‐enzymatic lactic acid sensor is elucidated by considering the morphology and cyclic voltammetry response. The limit of detection for the sensor was found to be 0.006 mM and it exhibits a linear range from 0.05–3 mM of lactic acid as shown by cyclic voltammetry. The amperometric response has shown the excellent current‐concentration response and the linear range of sensor was found to be 0.1 mM to 5.5 mM. The lactic acid sensor is stable, selective and can be used for practical applications. This study provides an excellent alternative analytical tool for the determination of lactic acid.  相似文献   

8.
An enzymatic sensor detecting the analyte formaldehyde directly from the gas phase is under investigation. In contrast to existing systems, it enables the quantification of the analyte without prior sampling or accumulation and thus can be used as an online system to monitor the formaldehyde concentration in ambient air. The amperometric sensor depends on the enzymatic conversion of the analyte using formaldehyde dehydrogenase from P. putida [EC. 1.2.1.46] as the recognition element. It shows a linear response curve up to 15 ppm, with a detection limit of 0.03 pm (S/N=3). In order to optimize the sensor performance the electrolyte composition within the sensor was varied with respect to pH value, buffer concentration and the addition of Ca2+ and Mg2+ ions. To elucidate the influence of the mediator and the enzyme on the sensor performance the stability and activity of the electrochemical mediator and the enzyme alone was examined separately in these different electrolytes.  相似文献   

9.
Readily water‐soluble PEGylated amphiphiles containing bis‐thiourea‐based molecular recognition units at the interface of hydrophobic and hydrophilic blocks are developed. Self‐assembly of these amphiphiles is found to be dependent on the exact chemical composition of the hydrophobic component. Elongated, spherical, and disk‐like micelles are formed with the change in hydrophobic group from stearyl (2A), oleyl (2B), and dodecanol (2C), respectively. The length of the rod‐like elongated micelles formed by 2A could be tuned by thermal treatment as well. Synthesis and detailed structural characterization of these amphiphiles by TEM, DSC, synchrotron SAXS techniques are reported. Organic solvent‐free direct aqueous encapsulation of doxorubicin, an anticancer drug into these nanostructures is demonstrated.

  相似文献   


10.
Blends of polystyrene/poly(methyl methacrylate) (PS/PMMA) (30/70) prepared by simple melt mixing form a droplet (PS) in‐matrix (PMMA) morphology. It is found that addition of a carefully designed copolymer PS‐b‐P(S‐ran‐MMA) (SSM) compatibilizer could convert the morphology into a co‐continuous system. Indeed, the continuity of the dispersed PS phase increased with an increase in PS‐b‐P(S‐ran‐MMA) content, and a fully co‐continuous morphology (continuity = 100%) was obtained at 20% SSM fraction with a characteristic size of 100 nm.

  相似文献   


11.
《Electroanalysis》2004,16(23):1984-1991
A sol‐gel technique was used for the preparation of a three dimensional carbon composite electrode modified with [Cu(bpy)2]Br2 complex. A reversible redox couple of Cu(II)/Cu(I) is observed at the electrode surface. The electrochemical behavior and stability of the modified electrode was characterized by cyclic voltammetry. The charge transfer coefficient (α) and charge transfer rate constant (Ks) for the modified electrode were determined by cyclic voltammetry, which were found to be 0.46 and 14.2 s?1, respectively. The modified electrode showed excellent catalytic activity toward bromate reduction at significantly reduced overpotentials and can be used successfully for amperometric detection of bromate. Under the optimized conditions, the calibration plots are linear in the concentration range 0.5 μM ?200μM. Detection limit (signal to noise is 3) and sensitivity were found to be 0.1 μM and 20 nA / μM, respectively. These analytical parameters compare favorably with those obtained with modern analytical techniques. The modified carbon ceramic electrode doped with Cu‐Complex shows a good reproducibility, a short response time (t<2 s), remarkable long term stability (>4 months) and especially good surface renewability by simple mechanical polishing (RSD for 6 successive polishing is 1.5%).  相似文献   

12.
Microphase separation of block copolymers (BCPs) has been extensively studied because it leads to the self‐assembled formation of periodic structures controlled on the scale of tens of nanometers. In particular, BCP‐derived cylindrical microdomains have attracted considerable interest for various applications owing to their well‐defined shapes of uniform and tunable diameters. This focus review highlights recent efforts to apply BCP‐derived monolithic films/membranes comprising cylindrical nanopores for chemical sensing and separations. The nanopores provide confined molecular pathways that exhibit enhanced selectivity based on steric, electrostatic, and chemical interactions, and thus, enable us to design unique electrochemical sensors and highly efficient separation membranes.  相似文献   

13.
The facile synthesis of a porous carbon material that is doped with iron‐coordinated nitrogen active sites (FeNC‐70) is demonstrated by following an inexpensive synthetic pathway with a zeolitic imidazolate framework (ZIF‐70) as a template. To emphasize the possibility of tuning the porosity and surface area of the resulting carbon materials based on the structure of the parent ZIF, two other ZIFs, that is, ZIF‐68 and ZIF‐69, are also synthesized. The resulting active carbon material that is derived from ZIF‐70, that is, FeNC‐70, exhibits the highest BET surface area of 262 m2 g?1 compared to the active carbon materials that are derived from ZIF‐68 and ZIF‐69. The HR‐TEM images of FeNC‐70 show that the carbon particles have a bimodal structure that is composed of a spherical macroscopic pore (about 200 nm) and a mesoporous shell. X‐ray photoelectron spectroscopy (XPS) reveals the presence of Fe‐N‐C moieties, which are the primary active sites for the oxygen‐reduction reaction (ORR). Quantitative estimation by using EDAX analysis reveals a nitrogen content of 14.5 wt. %, along with trace amounts of iron (0.1 wt. %), in the active FeNC‐70 catalyst. This active porous carbon material, which is enriched with Fe‐N‐C moieties, reduces the oxygen molecule with an onset potential at 0.80 V versus NHE through a pathway that involves 3.3–3.8 e? under acidic conditions, which is much closer to the favored 4 e? pathway for the ORR. The onset potential of FeNC‐70 is significantly higher than those of its counterparts (FeNC‐68 and FeNC‐69) and of other reported systems. The FeNC‐based systems also exhibit much‐higher tolerance towards MeOH oxidation and electrochemical stability during an accelerated durability test (ADT). Electrochemical analysis and structural characterizations predict that the active sites for the ORR are most likely to be the in situ generated N? FeN2+2/C moieties, which are distributed along the carbon framework.  相似文献   

14.
The article describes the preparation of supported nickel nanoparticles (NiNPs) by partial reduction of Ni,Co‐layered double hydroxide (NiCo‐LDH). The nanocomposites were characterized by X‐ray diffraction and their morphology and composition were characterized by scanning electron microscopy and transmission electron microscopy. The electrochemical properties of the nanocomposite were explored by cyclic voltammetry and amperometry, which revealed significant electrocatalytic behavior towards the oxidation of glucose. The resulted non‐enzymatic glucose sensor has a linear response to glucose in the 5.0 μM to 14.8 mM concentration range, a low detection limit of 1.6 μM, high sensitivity, and excellent selectivity.  相似文献   

15.
The electrochemical, selective determination of catechol (CT) in the presence of hydroquinone (HQ) is not readily achieved, because the formal potentials of two phenolic compounds are very close. Here, we have developed a simple electrochemical method for the selective determination of CT by using bare indium tin oxide electrodes and employing CT redox cycling by hydrazine. The cyclic voltammetry of CT and HQ was investigated in Tris buffer (pH 9.0), phosphate buffered saline buffer (pH 7.4), and acetate buffer (pH 4.5). Especially in Tris buffer, the anodic peak potential of CT is much lower than that of HQ, resulting in a large difference between two peak potentials (ca. 0.4 V). The difference allows the selective determination of CT in the presence of excess HQ. The anodic current of CT is amplified using CT redox cycling by hydrazine, which also helps to stabilize CT and HQ in Tris buffer for several hours. The detection limits of CT in Tris buffer containing 0.1 mM HQ are 1 μM and 10 μM in the presence and absence of hydrazine, respectively.  相似文献   

16.
A new and progressive electroanalytical sensor was made by the incorporation of Pt‐doped NiO nanoparticle (Pt‐NiO‐NPs) into carbon paste electrode (CPE) amplified with 1‐hexyl‐3‐methylimidazolium tetrafluoroborate (1H3MTFB) as a conductive binder. The Pt‐NiO‐NPs/1H3MTFB/CPE caused an extraordinary rise in the oxidation peak current of epinine (~4.6 times) and simultaneous reduction in the oxidation over‐potential of catecholamine drug (~120 mV). SWV method was employed to investigate the ability of Pt‐NiO‐NPs/1H3MTFB/CPE as an electroanalytical sensor in the determination of epinine in the presence of phenylephrine as two blood pressure raising drugs with ΔE=280 mV for the first time. Experimental results pertinent to SW voltammetric investigation reveal a linear relation between epinine and phenylephrine currents and drugs concentration in the rages 0.004–450 and 0.02–350 μM, respectively.  相似文献   

17.
《Electroanalysis》2017,29(5):1481-1489
Polymorphs of Manganese di oxide (MnO2) such as alpha (α), beta (β), gamma (γ), epsilon (ϵ), and MnOOH type materials were prepared via hydrothermal approach under different conditions. The samples were characterized by XRD, FESEM, FT‐IR, Raman and BET analysis. Cyclic voltammetry (CV) analysis confirm that α ‐ MnO2 shows better electro‐catalytic ability. Amperometry sensing of hydrogen peroxide (H2O2) was carried out by varying applied potential value with the polymorphs of MnO2. Compared with the other phases of MnO2, α ‐ MnO2 shows high linear range up to 20μM. The calculated sensitivity value for H2O2 sensing of different phases is in the order of α ‐ MnO2, β ‐ MnO2, ϵ ‐ MnO2, γ ‐ MnO2, MnOOH and found to be 0.094 mA μM−1 cm−2 > 0.072 mA μM−1 cm−2 > 0.07 mA μM−1 cm−2 > 0.03 mA μM−1 cm−2 > 0.01 mA μM−1 cm−2 respectively. All the characterization results reveal that crystalline phase plays a vital role in electrochemical behavior rather than crystalline size, morphology, surface charge, surface area.  相似文献   

18.
In this mini‐review, we highlighted the recent progresses in the controlled synthesis of metal sulfides hollow nanostructures via hard template technique. After a brief introduction about the formation mechanism of the inorganic hollow nanostructures via hard template technique, the discussions primarily focused on the emerging development of metal sulfides hollow nanostructures. Various synthetic strategies were summarized concerning the use of the hard template engaged strategies to fabricate various metal sulfides hollow nanostructures, such as hydrothermal method, solvothermal method, ion‐exchange, sulfidation or calcination etc. Finally, the perspectives and summaries have been presented to demonstrate that a facile synthetic technique would be widely used to fabricate metal sulfides hollow nanostructures with multi‐shells and components.  相似文献   

19.
In this study, Prussian blue (PB) film on the electroreduced graphene oxide (ERGO)‐modified Au electrode surface (ERGO/PB) is easily prepared by means of cyclic voltammetric technique in the mixture of K3Fe(CN)6 and FeCl3. Its electrochemical behaviors for NADH biosensor are studied. The structural and morphological characters of modified electrode material are analyzed with using of XPS, XRD, Raman, EDS, and SEM techniques. ERGO/PB hybrid nanocomposite for NADH biosensor is exhibited to the higher catalytic effect (linear range from 1.0 to 100 μM, detection limit of 0.23 μM at S/N=3) compared to naked Au, ERGO‐modified Au, and PB‐modified Au electrodes. In addition to, ERGO/PB electrode was used to voltammetric and amperometric detection of H2O2. ERGO/PB electrodes also showed the same behavior as the NADH sensor. This ERGO/PB‐modified electrode supplied a simple, new, and low‐cost route for amperometric sensing of both NADH and H2O2.  相似文献   

20.
《Electroanalysis》2017,29(2):587-594
A sensitive and selective hydrazine sensor was developed by β‐cyclodextrin modified palladium nanoparticles decorated reduced graphene oxide (PdNPs‐β‐CD/rGO) nanocomposite. The PdNPs‐β‐CD/rGO hybrid material was prepared by simple electrochemical method. The hydrophobic cavity of β‐CD ineracts with palladium nanoparticles by hydrophobic interaction and further it is uniformly assembled on the rGO surface through hydrogen bond formation, which is clearly confirmed by FT‐IR, FESEM and TEM. The high electrocatalytic activity of hydrazine oxidation was observed at −0.05 V (vs. Ag/AgCl) on PdNPs‐β‐CD/rGO modified electrode; due to the excellent stabilization, high catalytic activity and large surface area of the PdNPs‐β‐CD/rGO composite. The PdNPs‐β‐CD/rGO fabricated hydrazine sensor exhibited an excellent analytical performance, including high sensitivity (1.95 μA μM−1 cm−2), lower detection limit (28 nM) and a wide linear range (0.05 to 1600 μM). We also demonstrated that the PdNPs‐β‐CD/rGO nanocomposite modified electrode is a highly selective and sensitive sensor towards detection of hydrazine among the various interfering species. Hence, the proposed hydrazine sensor is able to determine hydrazine in different water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号