首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electrochemical method for the simultaneous determination of benzene, toluene and xylenes (BTX) in water was developed using square‐wave voltammetry (SWV). The determination of BTX was carried out using a cathodically pre‐treated boron‐doped diamond electrode (BDD) using 0.1 mol L?1 H2SO4 as supporting electrolyte. In the SWV measurements using the BDD, the oxidation peak potentials of the total xylenes‐toluene and toluene‐benzene couples, present in ternary mixtures, display separations of about 100 and 200 mV, respectively. The attained detection limits for the simultaneous determination of benzene, toluene and total xylenes were 3.0×10?7, 8.0×10?7 and 9.1×10?7 mol L?1, respectively. The recovery values taken in ternary mixtures of benzene, toluene and total xylenes in aqueous solutions are 98.9 %, 99.2 % and 99.4 %, respectively.  相似文献   

2.
The present work describes the first electrochemical investigation and a simple, rapid and modification‐free electroanalytical methodology for quantification of hordenine (a potent phenylethylamine alkaloid) using a boron‐doped diamond electrode. At optimized square‐wave voltammetric parameters, the observed oxidation peak current in 0.1 M HClO4 at +1.33 V (vs. Ag/AgCl) increased linearly from 5.0 to 100 μg mL?1 (3.0×10?5–6.1×10?4 M), with detection limit of 1.3 μg mL?1 (7.8×10?6 M). The applicability of the developed method was tested with the determination of hordenine in the commercial dietary supplement formulations.  相似文献   

3.
Electrochemical oxidation of azoxystrobin, a systemic fungicide commonly used in agriculture to protect a wide variety of crops, was investigated using cyclic voltammetry with a boron‐doped diamond electrode (BDDE) in aqueous buffer solutions. Two pH independent irreversible anodic current peaks controlled mostly by diffusion were observed in wide pH range (2 to 12) at potentials +1600 mV and +2150 mV vs. saturated silver‐silver chloride electrode. Mechanism of the electrochemical oxidation was proposed and supported with high performance liquid chromatography/mass spectrometry analysis of azoxystrobin solutions electrolyzed on carbon fiber brush electrode. The main product of the first two‐electron oxidation step was identified as methyl 2‐(2‐{[6‐(2‐cyanophenoxy)pyrimidin‐4‐yl]oxy}phenyl)‐2‐hydroxy‐3‐oxopropanoate. An analytical method for the determination of azoxystrobin in water samples and pesticide preparation by differential pulse voltammetry with BDDE was developed. The method provides a wide linear dynamic range (3.0×10?7 to 2.0×10?4 mol L?1) with limit of detection 8×10?8 mol L?1. Accuracy of the method was evaluated by the addition and recovery method with recoveries ranging from 96.0 to 105.8 %. Interference study proved sufficient selectivity of the developed voltammetric method for the azoxystrobin determination in presence of azole fungicides as well as pesticides used to prevent the same crops.  相似文献   

4.
An electroanalytical method for the simultaneous determination of paracetamol (PAR), caffeine (CAF), and orphenadrine (ORPH) using the square‐wave voltammetry (SWV) and a cathodically pretreated boron‐doped diamond electrode was developed. The method exhibits linear responses to PAR, CAF, and ORPH in the concentration ranges 5.4×10?7–6.1×10?5 M, 7.8×10?7–3.5×10?5 M, and 7.8×10?7–3.5×10?5 M, respectively, with detection limits of 2.3×10?7 M, 9.6×10?8 M, and 8.4×10?8 M, respectively. The proposed method was successfully applied in the simultaneous determination of these analytes in pharmaceutical formulations.  相似文献   

5.
《Electroanalysis》2018,30(5):868-876
Antihistamines such as pheniramine (PHN) or chlorpheniramine (CPH) are commonly associated with naphazoline (NPZ) in eye drops and nasal decongestants. In this work, a batch‐injection analysis system with multiple pulse amperometric (BIA‐MPA) detection has been applied for the first time for fast simultaneous determination of naphazoline (NPZ) and pheniramine (PHN) or NPZ and chlorpheniramine (CPH). PHN or CPH was selectively detected at +1.1 V and both PHN and NPZ or CPH and NPZ were detected at +1.3 V using boron doped diamond (BDD) as working electrode and Britton‐Robinson (BR) buffer (pH=10.0) as supporting electrolyte. The current of NPZ can then be obtained by subtraction of the currents detected at both potential pulses and applying a correction factor (CF). The proposed method presented good intra‐day repeatability (RSD between 0.7 and 3.2 % for PHN; 0.7 and 2.1 % for CPH; 1.5 and 4.0 % for NPZ; n=20), high analytical frequency (>80 injections h−1), and limits of detection of 0.64, 0.47 and 0.11 μmol L−1 for PHN, CPH and NPZ, respectively. The results obtained with the proposed method are in agreement with those obtained by HPLC (95 % confidence level).  相似文献   

6.
Voltammetric methods for estrone determination were developed using a cathodically pretreated BDD electrode with DPV or SWV. Analytical curves were obtained for estrone concentrations from 0.20 or 0.10 to 2.0 µmol L?1, for DPV or SWV, with detection limits of 0.20 and 0.10 µmol L?1, respectively. The SWV method was successfully applied in estrone recovery studies in different water matrices. Additionally, these recovery results were reasonably similar to those attained using HPLC/UV‐vis. Comparatively to other electroanalytical methods based on different carbon electrodes, the here‐reported novel methods yield very good results, being adequate for estrone determination in environmental samples.  相似文献   

7.
A cathodically pretreated boron‐doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry. Linear calibration curves (r=0.999) were obtained from 1.9×10?5 to 2.1×10?4 mol L?1 for AA and from 9.7×10?6 to 1.1×10?4 mol L?1 for CAF, with detection limits of 19 μmol L?1 and 7.0 μmol L?1, respectively. This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations, with results equal to those obtained using a HPLC reference method.  相似文献   

8.
An electroanalytical method for the determination of morpholine, a corrosion inhibitor, was developed at a cathodically pretreated boron-doped diamond electrode (BDDE). The voltammetric response of morpholine at the BDDE in 0.1?mol L?1 KCl (pH 10) shows an irreversible oxidation process at approximately 1.3?V vs. Ag/AgCl in 3.0?mol L?1 KCl. Using cyclic voltammetry, the number of electrons involved in the morpholine electroxidation mechanism was found to be 1. The application of chronoamperometry showed that the apparent diffusion coefficient (D0) was 2.99?×?10?6 cm2 s?1. Using square wave voltammetry under the optimized conditions (frequency of 30.0?Hz, pulse amplitude of 100?mV and step potential of 20?mV at pH 10.0), the developed method provided limits of detection and quantification of 2.1 and 6.9?mg L?1, respectively, with a linear range from 5.0 to 100.0?mg L?1 (r?=?0.991). Intraday (n?=?10) and interday (two consecutive day) precision values assessed as the relative standard deviation for solutions containing 30.0, 60.0, and 90.0?mg L?1 of morpholine were from 0.41 to 5.86% and 0.92 to 3.19%, respectively. The feasibility of the method for the interference-free determination of morpholine was verified by the analysis of synthetic boiler water samples containing CaCO3, Na2SO3, Na3PO4, FeCl3, and humic acid as organic matter. In addition, hydrazine was added as a possible interfering compound because of its widespread use in corrosion inhibition. Recovery values from 90.9 to 109.4% were obtained in the synthetic boiler water, thereby attesting to the accuracy of the method.  相似文献   

9.
《Electroanalysis》2017,29(7):1783-1793
Ricin, (Ricinus communis agglutinin, RCA) is one of the most poisonous of naturally occurring substances and has great potential for bioterrorism because no antidote exists. Fast detection at low concentrations is a challenge, and vital to the development of proper countermeasures. In this study, a square wave adsorptive stripping voltammetric (SWAdSV) method for determining RCA using a cathodically polarized boron‐doped diamond (BDD) electrode is presented. An irreversible electrochemical RCA oxidation peak was identified on the BDD electrode by different voltammetric techniques using both direct and adsorptive stripping modes. An adsorption‐controlled (slope log Ip vs log v of 0.80) pH‐dependent process was observed. For values of 1.0≤pH≤9.0, the numbers of protons and electrons associated with the oxidation reaction were estimated (ca. 1.0) by differential pulse voltammetry. The RCA oxidation step may correspond to the oxidation of tryptophan amino acid residues, and occurs in a complex mechanism. The excellent analytical performance of the cathodically polarized BDD electrode in combination with the stripping mode ramp was verified with RCA by using a short deposition time in an open circuit potential (120 s). Under optimized analysis conditions, a linear response in the range of (3.3–94.0)×10−9 mol L−1 (r2=0.9944) and a limit of detection of 6.2×10−10 mol L−1 were estimated. This LOD is lower than several methods found in the literature. For example, it is 168 times lower than that obtained by using square wave voltammetric with a glassy carbon electrode. Moreover, an even lower LOD might be achieved by using the SWAdSV method with a higher pre‐concentration time. In addition, trace levels of RCA were successfully determined in different castor seed cultivars with an overall average recovery from 99.2±1.6 % for the three different RCA‐A concentration levels. The high accuracy of the analytical data highlights the use of the proposed method for determining RCA in other samples.  相似文献   

10.
N‐acetylcysteine (NAC) and gentamicin sulfate (GS) are biologically and pharmaceutically relevant thiol‐containing compounds. NAC is well known for its antioxidant properties, whereas GS is an aminoglycoside that is used as a broadband antibiotic. Both pharmaceuticals play a significant role in the treatment of bacterial infections by suppressing the formation of biofilms. According to the European Pharmacopeia protocol, GS is analyzed by high performance liquid chromatography (HPLC) using gold electrodes for electrochemical detection. Here, we report the electrochemical detection of these compounds at NH2‐terminated boron‐doped diamond electrodes, which show significantly reduced electrode passivation, an issue commonly known for gold electrodes. Cyclic voltammetry experiments performed for a period of 70 minutes showed that the peak current decreased only by 1.6 %/7.4 % for the two peak currents recorded for GS, and 6.6 % for the oxidation peak of NAC, whereas at gold electrodes a decrease in peak current of 14.2 % was observed for GS, and of 64 %/30 % for the two peak currents of NAC. For their quantitative determination, differential pulse voltammetry was performed in a concentration range of 2–49 µg/mL of NAC with a limit of detection (LOD) of 1.527 µg/mL, and a limit of quantification (LOQ) of 3.624 µg/mL, respectively. The quantification of GS in a concentration range of 0.2–50 µg/mL resulted in a LOD of 1.714 µg/mL, and a LOQ of 6.420 µg/mL, respectively.  相似文献   

11.
A simple, rapid and feasible method is developed for direct and simultaneous determination of phenol (Ph), hydroquinone (HQ) and 4‐nitrophenol (4‐NP) on unmodified boron‐doped diamond (BDD) electrode. Results showed that the oxidative peaks of these three phenolic compounds can be completely separated on BDD electrode in acidic conditions by using electrochemical cyclic voltammetry technique. The peak potential separations are all higher than 0.35 V. Moreover, BDD electrode is extremely easy to be refreshed to obtain current values with good reproducibility, even if it is passivated by phenolic compounds with different adsorption characteristics. All the above features are on account of the outstanding electrochemical characteristics of BDD electrode, and lead to the advantage and feasibility for simultaneous determination of three phenolic compounds without any other separation operation. For each tested phenolic compound, the concentration range with linearity is in two or three orders of magnitude in the presence of other coexisting phenolic compounds with the concentrations more than 1000 times higher than that of the tested component. The present method is also shown to be promising for the determination of phenolic contaminants in the real wastewater samples.  相似文献   

12.
The performance of hydrogen‐ (HT) and oxygen‐terminated (OT) boron‐doped diamond (BDD) electrodes (electrochemically pretreated) on the simultaneous differential pulse voltammetric determination of sulfamethoxazole and trimethoprim in pharmaceutical products is presented. Under the optimum analytical experimental conditions, the HT‐BDD electrode presented two well‐defined oxidation peaks at 920 and 1100 mV vs. Ag/AgCl for sulfamethoxazole and trimethoprim, respectively. On the other hand, when the OT‐BDD electrode was used, the sulfamethoxazole oxidation current peak was decreased twenty fold. The calculated LOD values for sulfamethoxazole and trimethoprim using the HT‐BDD electrode were 3.65 μg L?1 and 3.92 μg L?1, respectively. The results obtained in the simultaneous determination of sulfamethoxazole and trimethoprim in three different commercial formulations were similar to those obtained using a standard HPLC method at 95% confidence level.  相似文献   

13.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

14.
Electrochemistry of gallic acid (GA) and ellagic acid (EA) was investigated by cyclic voltammetry (CV) using a bare boron‐doped diamond (BDD) electrode. CVs indicate that the electro‐oxidation of both GA and EA are quasi‐reversible processes. High‐performance liquid chromatography (HPLC) coupled with a BDD electrode poised at+1.4 V offers the limit of detection (LOD, S/N=3) of 60 and 200 nM for GA and EA, respectively. The optimized method was then applied to the detection of both acids in Islay, Highland and Scotch whiskeys, with the highest concentrations found in a 14‐year‐old Highland whiskey.  相似文献   

15.
The electrochemical methods cyclic and square‐wave voltammetry were applied to develop an electroanalytical procedure for the determination of N‐nitrosamines (N‐nitrosopyrrolidine, N‐nitrosopiperidine and N‐nitrosodiethylamine) in aqueous solutions. Cyclic voltammetry was used to evaluate the electrochemical behaviors of N‐nitrosamines on boron‐doped diamond electrodes. It was observed an irreversible electrooxidation peak located in approximately 1.8 V (vs. Ag/AgCl) for both N‐nitrosamines. The optimal electrochemical response was obtained using the following square‐wave voltammetry parameters: f=250 Hz, Esw=50 mV and Es=2 mV using a Britton–Robinson buffer solution as electrolyte (pH 2). The detection and quantification limits determined for total N‐nitrosamines were 6.0×10?8 and 2.0×10?7 mol L?1, respectively.  相似文献   

16.
Guaiacol and its analogs, a distinct flavor in whiskey, foods, and beverages, display different inclusion complexes with α‐Cyclodextrin (α‐CD) and can be detected on a Nafion modified boron‐doped diamond (BDD) electrode. The stable Nafion layer preconcentrates the analyte‐α‐CD complexes prior to electroanalysis by square wave voltammetry (SWV) to enhance detection sensitivities. This sensing mode together with peak deconvolution successfully distinguishes between guaiacol, 4‐ethylguaiacol (4‐EG), three cresol isomers, and phenols in a popular whiskey brand. The results obtained are corroborated by high‐performance liquid chromatography (HPLC). Anodic oxidation at + 2 V in phosphate buffer, pH 7 is proven as an effective method to renew the electrode surface after its exposure to the guaiacols. This robust approach circumvents several drawbacks associated with the use of enzymes and nanomaterials for the analysis of such analytes as reported in the literature.  相似文献   

17.
Determination of berberine, an isoquinoline plant alkaloid, with antibacterial, antiparasitic, antifungal, hypotensive and antitumoral effects, was proposed by introducing square wave voltammetry on boron‐doped diamond electrode. At optimized experimental parameters, in Britton‐Robinson buffer solution pH 5 berberine provides 3 oxidation peaks (+0.63; +1.14 and +1.34 V) and one reduction (+0.15 V) (vs. Ag/AgCl electrode), with good repeatability (relative standard deviation of 2.6 % and 1.9 % for 8 measurements at 0.5 and 10 µM concentration level, respectively). Calibration curve was linear in wade linear range from 0.1 to 50 µM with limit of detection of 0.04 µM. The proposed procedure was successfully applied for the determination of berberine in seed extract from Argemone mexicana with satisfactory recovery (102–102.6 %). The developed method may represent a sensitive alternative to highly toxic mercury electrodes, modified electrodes and chromatographic methods.  相似文献   

18.
《Electroanalysis》2006,18(8):830-834
A facile method for the simultaneous measurement of tryptophan (Trp) and tyrosine (Tyr) was firstly exploited at unmodified boron‐doped diamond (BDD) electrode. The experimental results indicated that by using differential pulse voltammetry, the oxidative peaks of these two kinds of amino acids could be completely separated at BDD electrode. The peak separation of Trp and Tyr was developed to be 0.64 V when Na2PO4/NaOH buffer solution with the optimized pH 11.2 was employed. The detection limit of Trp was obtained to be 1×10?5 M, while that of Tyr was achieved to be 1×10?6 M. The present method was also evidenced to be available to the determination of real samples of amino acids.  相似文献   

19.
This work presents a simple, fast and low‐cost method for the simultaneous determination of three drugs by flow‐injection analysis with multiple‐pulse amperometric (MPA) detection using a wall‐jet flow cell with a boron‐doped diamond electrode. The amperometric determination of caffeine (CF), ibuprofen (IB) and paracetamol (PC) was performed by the application of a four‐potential waveform using the MPA technique. PC is oxidized at E1 (1.20 V/70 ms) and thus selectively detected; PC and CF are oxidized at E2 (1.49 V/40 ms); PC, CF and IB are oxidized at E3 (1.70 V/70 ms); and E4 (1.80 V/100 ms) is applied for electrode cleaning. The subtraction of currents obtained at the different potentials did not provide accurate determinations of CF and IB, thus it was required to investigate correction factors to determine CF and IB without the interference from PC and CF using the respective amperometric signals obtained at E2 and E3. The proposed method was successfully applied for the determination of three drugs in pharmaceutical samples with low generation of residues and a high analytical frequency (150 h?1) in comparison with HPLC‐DAD method.  相似文献   

20.
《Analytical letters》2012,45(5-6):449-459
Based on the study of voltammetric behavior of carcinogenic 1-nitropyrene (1-NP), 1-aminopyrene (1-AP), and 1-hydroxypyrene (1-HP), optimum conditions have been found for the determination of these analytes by differential pulse voltammetry (DPV) at a boron-doped diamond film electrode. The optimum medium was methanol-Britton–Robinson buffer (BR buffer) pH 3.0 (70:30) for 1-NP and 1-AP, and methanol-BR buffer pH 5.0 (70:30) for 1-HP. Concentration dependences of the DPV response were measured in the range 1 · 10?6–1 · 10?4 mol dm?3 (R = ?0.9998) with the limit of detection (LOD) 3 · 10?7 mol dm?3 for 1-NP, 1 · 10?7–1 · 10?5 mol dm?3 (R = 0.9971) with LOD 6 · 10?8 mol dm?3 for 1-AP, and 1 · 10?7–1 · 10?5 mol dm?3 (R = 0.9934) with LOD 1 · 10?7 mol dm?3 for 1-HP. Simultaneous determination of 1-NP and 1-AP in a mixture was tested in the methanol-BR buffer pH 3.0 (70:30) medium as well. The content of 1-AP in the concentration range from 1 · 10?6 to 1 · 10?4 mol dm?3 had no effect on the sensitivity of the determination of 1-NP, and vice versa. Due to the close peak potentials of 1-AP and 1-HP, the direct determination of their mixture using voltammetric methods is impossible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号