1.
An ethanol biosensor based on alcohol dehydrogenase (ADH) attached to Au seeds decorated on magnetic nanoparticles (Fe3O4@Au NPs) is presented. ADH was immobilized on Fe3O4@Au NPs, which were subsequently fixed by a magnet on a carbon paste electrode modified with 5 % (m : m) MnO2. Optimum conditions for the amperometric determination of ethanol with the biosensor were as follows: working potential +0.1 V (vs. Ag/AgCl); supporting electrolyte: 0.1 M phosphate buffer solution at pH 6.8 containing 0.25 mM of the coenzyme (NAD+); working electrode: carbon paste with magnetically attached Fe3O4@Au NPs (0.012 mg ? cm?2 electrode area) with immobilized alcohol dehydrogenase (120 units per cm2 of electrode area). Linearity between signal and concentration was found for the range from 0.1 to 2.0 M ethanol (r2=0.995) with a detection limit of 0.07 M, a sensitivity of 0.02 µA ? mM?1 ? cm?2, a reproducibility of 4.0 % RSD, and a repeatability of 2.7 % RSD. The results for the determination of ethanol in alcoholic beverages showed good agreement with gas chromatography (GC) with recovery of 96.0 – 108.8 %.  相似文献   

2.
Herein, we reported a titanium oxide (TiO2) modified activated carbon nanocomposite that showed advantageous characteristics in terms of electro-conductivity, catalytic activity and surface area. The designed nanocomposite was employed to modify the screen printed carbon electrode transducer surface in the construction of an electrochemical sensor. The electrode surface modification was characterised by cyclic voltammetry and impedimetric studies. The modified transducer surface was subsequently used for the detection of four phenolic endocrine disruptors, p-nitrophenol, hydroquinone, catechol and 1-naphtol. Under optimal conditions, TiO2 modified activated carbon sensor was evaluated by differential pulse voltammetry showing a good linearity with correlation coefficients higher than 0.99. It showed, in parallel, a high sensitivity where the detection limits were 348 ng/L, 110.1 ng/L, 3.3 ng/L and 7.2 µg/L for the respective studied compounds (S/N = 3). Finally, we validated the method with river water samples, and good recovery values were obtained showing the potential application of the reported biosensor.  相似文献   

3.
A mediator‐free choline biosensor was developed using the electrochemically assisted sol‐gel deposition on gold screen‐printed electrodes. The addition of 12 mM of cationic surfactant CTAB in silica sol allowed enhancing the stability of the sensor. The modified electrode demonstrated catalytic activity and stable amperometric response to choline for over 3 weeks of exploitation with the sensitivity of 6 µA mM?1 and LOD of 6 µM. The interference of ascorbic acid was reduced by pretreating the analyzed solution with MnO2 powder. The application of the sensor with the purpose of identifying choline in the baby milk demonstrated satisfactory metrological characteristics.  相似文献   

4.
Nanocrystalline zeolites of different framework structures were prepared by the addition of suitable structure directing agents in the synthesis composition of conventional zeolites. Zeolite modified carbon paste electrodes were constructed for the simultaneous determination of dihydroxybenzene isomers. Nanocrystalline zeolite Beta modified carbon paste electrode exhibited the highest electrocatalytic activity. Under optimum conditions, wide linear range was obtained from 150 nM to 400 µM with lower detection limit of 100, 130, and 100 nM for hydroquinone, catechol, and resorcinol, respectively. The analytical performance of the proposed sensor was demonstrated in the simultaneous determination of dihydroxybenzene isomers in different environmental water samples.  相似文献   

5.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

6.
A novel perylenediimide derivative, N,N′-bis(4-{2-[2-(2-methoxyethoxy ethoxy]ethoxy}phenyl)-3,4:9,10-perylene tetracarboxydiimide, was utilized for the modification of a carbon paste electrode to develop a practical and sensitive electrochemical sensor for dopamine detection. The effects of experimental parameters (modifier amount, pH, and scan rate) on the dopamine peak current were examined. The performance of the modified carbon paste electrode was evaluated under optimum conditions and 4.6-fold increase in the peak current was obtained compared to an unmodified carbon paste electrode. The linear range was between 1 and 100?µM dopamine and the limits of detection and quantification were 0.011 and 0.036?µM, respectively. The developed sensor was also applied for the quantitative determination of dopamine in injections and promising results were obtained.  相似文献   

7.
A novel H2O2 amperometric biosensor based on the electrodeposition of gold nanoparticles (AuNPs) and CdS quantum dots (CdS QDs) onto a carbon paste electrode (CPE) and immobilizing hemoglobin (Hb) with ionic liquid (IL), is presented in this article. The modification process of the electrode was monitored by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Due to synergistic effects of AuNPs, CdS QDs and IL, the biosensor exhibited high stability and good bioelectrocatalytic ability to H2O2 with a linear concentration range from 10 to 750 µM and a detection limit of 4.35 µM (S/N=3).  相似文献   

8.
MnO2/graphene nanocomposites with different morphologies were synthesized and the petal‐shaped nanosheet MnO2/graphene composite was developed as an electrode material for nonenzymatic hydrogen peroxide (H2O2) sensor. The morphology, structure, composition, and hydrophilicity of the resulting products were characterized by scanning electron microscopy (SEM), X‐ray diffraction (XRD), thermogravimetric analysis (TGA), and the contact angle tests. In addition, the fabricated MnO2/graphene composites could be used as catalysts for the electrochemical oxidation of H2O2. Cyclic voltammogram (CV) experiments indicated that MnO2/graphene‐modified electrode showed good electrocatalytic activity towards both the oxidation and reduction of H2O2 in a neutral environment. Amperometric response results illustrated that this nonenzymatic sensor had excellent anti‐interference ability and displayed two linear ranges from 10 to 90 µM and from 0.2 to 0.9 mM with a detection limit of 2 µM.  相似文献   

9.
A sensitive dopamine sensor was constructed based on the modified carbon paste electrode with methylthiouracil as a nucleophile in the 1,4‐Michael addition reaction. An ECE mechanism was suggested for dopamine oxidation at the modified electrode. Design of experiments was used in the optimization of variables. Under the optimum conditions, calibration graph was linear in the range of 0.20–15.0 µM with a detection limit of 73 nM. The relative standard deviations (n=5) for 0.50 µM of dopamine was 3.83 %. The selectivity of the sensor was also studied. The developed sensor was applied for analysis of pharmaceutical and biological samples.  相似文献   

10.
A carbon fiber microelectrode modified with a composite film of carbon nanotubes and Nafion was developed for in vivo ascorbate (AA) measurements in brain tissue. The modified‐microelectrodes exhibit an electrocatalytic activity for AA oxidation by shifting the peak potential negatively to ?0.040 V, showing a sensitivity of 37 pA/µM, a detection limit of 2.5 µM, a response time of 0.3 s and don’t respond to several electroactive compounds found in the brain extracellular space. In the rat hippocampus, the basal concentration of AA was 290 µM, and glutamate‐evoked changes in AA were biphasic comprising fast and slow components.  相似文献   

11.
In this work, the modified carbon paste electrode (CPE) with an imidazole derivative 2‐(2,3 dihydroxy phenyl) 4‐methyl benzimidazole (DHPMB) and reduced graphene oxide (RGO) was used as an electrochemical sensor for electrocatalytic oxidation of N‐acetyl‐L‐cysteine (NAC). The electrocatalytic oxidation of N‐acetyl‐L‐cysteine on the modified electrode surface was then investigated, indicating a reduction in oxidative over voltage and an intensive increase in the current of analyte. The scan rate potential, the percentages of DHPMB and RGO, and the pH solution were optimized. Under the optimum conditions, some parameters such as the electron transfer coefficient (α) between electrode and modifier, and the electron transfer rate constant) ks) in a 0.1 M phosphate buffer solution (pH=7.0) were obtained by cyclic voltammetry method. The diffusion coefficient of species (D) 3.96×10?5 cm2 s?1 was calculated by chronoamperometeric technique and the Tafel plot was used to calculate α (0.46) for N‐ acetyl‐L‐cysteine. Also, by using differential pulse voltammetric (DPV) technique, two linear dynamic ranges of 2–18 µM and 18–1000 µM with the detection limit of 61.0 nM for N‐acetyl‐L‐cysteine (NAC) were achieved. In the co‐existence system of N‐acetyl‐L‐cysteine (NAC), uric acid (UA) and dopamine (DA), the linear response ranges for NAC, UA, and DA are 6.0–400.0 µM, 5.0–50.0 µM and 2.0–20.0 µM, respectively and the detection limits based on (C=3sb/m) are 0.067 µM, 0.246 µM and 0.136 µM, respectively. The obtained results indicated that DHPMB/RGO/CPE is applicable to separate NAC, uric acid (UA) and dopamine (DA) oxidative peaks, simultaneously. For analytic performance, the mentioned modified electrode was used for determination of NAC in the drug samples with acceptable results, and the simultaneous determination of NAC, UA and DA oxidative peaks was investigated in the serum solutions, too.  相似文献   

12.
《Analytical letters》2012,45(6):996-1014
A novel electrochemical sensor for bisphenol A was developed through the combination of a molecular imprinting technique with a multiwalled carbon nanotube paste electrode. A molecularly imprinted polymer and nonimprinted polymer were synthesized in the presence and absence of bisphenol A, and then used to prepare the electrode. The bisphenol A imprinted polymer was applied as a selective recognition element in the electrochemical sensor. Differential pulse voltammetry was used to characterize the electrochemical behavior of bisphenol A at the modified electrodes. The results showed that the imprinted sensor had highest response for bisphenol A. Parameters including the carbon paste composition, pH, and adsorption time for the imprinted sensor were optimized. Under the optimized conditions, the differential pulse voltammetry peak current was linear with the concentration of bisphenol A from 0.08 to 100.0 µM, with a detection limit of 0.022 µM. The imprinted sensor for bisphenol A exhibited good selectivity, stability, and reproducibility. This sensor was successfully used for the determination of bisphenol A in real water samples.  相似文献   

13.
We studied a rapid, sensitive and selective amperometric sensor for determination of hydrogen peroxide by electrodeposited Ag NPs on a modified glassy carbon electrode (GCE). The modified GCE was constructed through a step by step modification of magnetic chitosan functional composite (Fe3O4–CH) and high-dispersed silver nanoparticles on the surface. The resulted Ag@Fe3O4–CH was characterized by various analytical methods including Fourier transform infrared spectroscopy, X-ray diffraction, transmission electron microscopy, scanning electron microscopy and cyclic voltammetry. The proposed sensor employed Ag@Fe3O4–CH/GCE as the working electrode with a linear current response to the hydrogen peroxide concentration in a wide range from 0.01 to 400 µM with a low limit of detection (LOD = 0.0038 µM, S/N = 3). The proposed sensor showed superior reproductivity, sensitivity and selectivity for the detection of hydrogen peroxide in environmental and clinical samples.  相似文献   

14.
《Analytical letters》2012,45(1):186-196
In the present paper, the use of a carbon paste electrode modified by ferrocene monocarboxylic acid (FMC) and carbon nanotubes prepared by a simple and rapid method was described. The modified electrode showed an excellent character for electrocatalytic oxidization of phenylhydrazine (PHZ) and hydrazine (HZ) with a 300 mV separation of both peaks. Differential pulse voltammetric peak currents of PHZ and HZ increased linearly with their concentrations at the range of 0.8 µM to 700 µM and 16 µM to 800 µM and the detection limits (3σ) were determined to be 0.42 µM and 14 µM, respectively.  相似文献   

15.
An exploration of gold nanoparticles–bacterial cellulose nanofibers (Au‐BC) nanocomposite as a platform for amperometric determination of glucose is presented. Two enzymes, glucose oxidase (GOx) and horseradish peroxidase (HRP) were immobilized in Au‐BC nanocomposite modified glassy carbon electrode at the same time. A sensitive and fast amperometric response to glucose was observed in the presence of electron mediator (HQ). Both of GOx and HRP kept their biocatalytic activities very well in Au‐BC nanocomposite. The detection limit for glucose in optimized conditions was as low as 2.3 µM with a linear range from 10 µM to 400 µM. The biosensor was successfully applied to the determination of glucose in human blood samples.  相似文献   

16.
Phenylethanolamine A (PEA), a β‐agonist, was found to be illegally used as a growth promoter in pigs last year, causing Chinese government's great attention. Here, a sensitive electrochemical method was developed for detecting PEA by immobilization of gold nanoparticles (AuNPs), multiwalled carbon nanotubes (MWCNTs) and Nafion on the surface of a glassy carbon electrode (GCE). The Nafion/MWCNTs/AuNPs film was characterized by scanning electronic micrographs (SEM) and electrochemical impedance spectroscopy (EIS). The electrochemical behaviors of PEA at the modified GCE were investigated in detail. The synergetic effects of AuNPs, MWCNTs and Nafion amplify the electrochemical reduction signal of PEA, and result in high sensitivity for PEA determination. Under the optimal conditions, the electrochemical sensor shows a wide linear range of 0.01 to 10 (mol/L with a detection limit of 0.005 µmol/L. Moreover, the fabricated sensor presents high selectivity and long‐term stability, which paves a new way for simple, rapid, sensitive detection of PEA.  相似文献   

17.
An electrochemical sensor for simultaneous quantification of Levodopa (L‐dopa) and Carbidopa (C‐dopa) using a β‐cyclodextrin/poly(N‐acetylaniline) (β‐CD/PNAANI) modified carbon paste electrode has been developed. Preconcentrating effect of β‐CD as well as its different inclusion complex stability with L‐dopa and C‐dopa was used to construct an electrochemical sensor for quantification of these important analytes. The overlapping anodic peaks of L‐dopa and C‐dopa at 810 mV on bare carbon paste electrode resolved in two well‐defined voltammetric peaks at 450 and 880 mV vs. Ag/AgCl, respectively, with a drastic enhancement of the anodic peak currents. Under optimized conditions, linear calibration curves were obtained in the ranges of 0.5–117 µM and 1.6–210 µM with detection limits down to 0.2 and 0.8 µM for L‐dopa and C‐dopa, respectively. The proposed electrode was successfully applied for the determination of L‐dopa /C‐dopa in pharmaceutical formulations and the results were in close agreement with the labeled values.  相似文献   

18.
In this work, a novel hydrogen peroxide biosensor derived from maize tassel (MT) and multiwalled carbon nanotube (MWCNT) composite was used to adsorb horseradish peroxidase (HRP) onto the surface of a glassy carbon electrode through electrostatic interactions. The morphology and structure of the products were characterized by SEM, FTIR and UV‐visible spectroscopy. The electrochemical and electrocatalytic performance of the HRP/MT‐MWCNT/GCE was studied using voltammetric and amperometric methods. The amperometric response of the biosensor varied linearly with concentration of H2O2 from 9 µM to 1 mM with detection limit of 4.0 µM (S/N=3). Furthermore, the biosensor exhibited good reproducibility and stability.  相似文献   

19.
The fabrication of a highly sensitive amperometric glucose biosensor based on silver nanowires (AgNWs) is presented. The electrochemical behavior of glassy carbon electrode modified by Ag NWs exhibits remarkable catalytic performance towards hydrogen peroxide (H2O2) and glucose detection. The biosensor could detect glucose in the linear range from 0.005 mM to 10 mM, with a detection limit of 50 µM (S/N=3). The glucose biosensor shows high and reproducible sensitivity of 175.49 µA cm?2 mM and good stability. In addition, the biosensor exhibits a good anti‐interference ability and favorable stability over relatively long‐term storage (more than 21 days).  相似文献   

20.
The behavior of a modified carbon paste electrode (CPE) for simultaneous determination of copper(II) and silver(I) by anodic adsorptive stripping voltammetry (ASV) was studied. The electrode was built incorporating the bis(2‐hydroxyacetophenone) butane‐2,3‐dihydrazone (BHAB) as a complexing agent to a Nujol‐graphite base paste. The resulting electrode demonstrated linear responses over the range of Cu(II) and Ag(I) concentrations 0.1–20 and 0.01–2.0 µM respectively. The relative standard deviation (RSD) for the determination of 5.0 µM of both metal ions were 2.9 and 3.1 % for Cu(II) and Ag(I), respectively. The method has been applied to the analysis of copper in wheat and barley seed samples and silver in developed radiological film.  相似文献   