 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2017,29(12):2793-2802
In this work, SiO2/Nb2O5/ZnO prepared by the sol‐gel processing method was used as substrate base for immobilization of the protoporphyrin‐IX ion. Iron(III) ion was inserted into the porphyrin ring (SiNbZn‐PPFe). A simple square wave voltammetry method based on a composite sensor carbon paste electrode of this material,designed as EPC‐SiNbZn‐PPFe, was developed and validated successfully for the determination of L‐tryptophan (Trp). The optimum conditions were obtained by using sensor modified with 18.00 mg SiNbZn‐PPFe material, 12.00 mg graphite powder and 6.0 μL mineral oil and phosphate buffer 0.3 mol L−1 pH 7.0. The sensitivity of the sensor was found to be 0.523 AL mol −1, linear range from 10 to 70 μmol L−1 and limit of detection of 3.28 μmol L−1. Therefore, the developed method was successfully applied for the Trp determination in real samples of pharmaceutical formulation and can be used for routine quality control pharmaceutical formulations containing Trp.  相似文献   

2.
In this work, the determination of gallic acid was performed using surface-renewable carbon paste electrodes fabricated with multi-walled carbon nanotubes (MWCNT) and a mixture of N-octylpyridinium hexafluorophosphate (OPyPF6) ionic liquid with mineral oil (MO) as binder. This system shows remarkable amperometric sensor characteristics and promotes a better electronic transfer. An electroanalytical study of gallic acid shows a linear range from 4.98±0.25 to 74.1±2.2 μmol L−1, with R2=0.9958 and an experiment a limit of detection of 2.70±0.08 μmol L−1 (S/N=3), and a sensitivity of 0.029 μA μmol−1 L.  相似文献   

3.
《中国化学》2017,35(8):1317-1321
A novel non‐enzymatic nitrite sensor was fabricated by immobilizing MnOOH‐PANI nanocomposites on a gold electrode (Au electrode). The morphology and composition of the nanocomposites were investigated by transmission electron microscopy (TEM ) and Fourier transform infrared spectrum (FTIR ). The electrochemical results showed that the sensor possessed excellent electrocatalytic ability for NO2 oxidation. The sensor displayed a linear range from 3.0 μmol•L−1 to 76.0 mmol•L−1 with a detection limit of 0.9 μmol•L−1 (S/N = 3), a sensitivity of 132.2 μA •L•mol−1•cm−2 and a response time of 3 s. Furthermore, the sensor showed good reproducibility and long‐term stability. It is expected that the MnOOH‐PANI nanocomposites could be applied for more active sensors and used in practice for nitrite sensing.  相似文献   

4.
The present work describes the development of a photoelectrochemical sensor based on titanium dioxide, cadmium telluride quantum dots and the tris (2,2′-bipyridyl) ruthenium(II) chloride complex for detection of Isoniazid (INH). The Ru(bpy)32+/CdTe-QDs/TiO2/FTO photoelectrochemical platform was characterized by scanning electrochemical microscopy, electrochemical impedance spectroscopy and amperometry. The photoelectrochemical sensor presented two linear ranges for INH concentrations ranging from 0.5 to 150 μmol L−1 and 150 to 1270 μmol L−1, with a theoretical detection limit of 0.02 μmol L−1. The sensor was successfully applied for the determination of INH in drugs samples used in the treatment of tuberculosis.  相似文献   

5.
A simple electroanalytical procedure has been developed for the determination of polyamine spermine using the ZnONPs-MWCNTs-CPE sensor. Spermine has been irreversibly oxidized on a modified electrode at a potential of +0.92 V versus Ag/AgCl (KCl, 3.5 mol L−1). The developed sensor demonstrated a respective linear response in borate buffer pH 8.5 from 2 μmol L−1 to 100 μmol L−1, with a detection limit of 0.300 μmol L−1 and quantification limit of 0.998 μmol L−1. The proposed sensor showed high reproducibility (RSD = 2.58 %), stability, robustness, and no obvious interference effects of several inorganic ions and organic molecules. The obtained results demonstrated excellent performance during the determination of the spermine in human urine samples with satisfactory recovery results (98.41–101.34 %), offering promising opportunities for practical clinical analysis.  相似文献   

6.
《Electroanalysis》2018,30(9):2176-2184
The contamination of water and wastewater by emerging pollutants, due to the anthropogenic activities, are an environmental problem that generates several negative impacts. In this range of species, steroids have gaining notoriety because their action of endocrine‐disruption. In this work, they are called estrogenic phenolic compounds (EPCs): estrone (E1), estradiol (E2), ethinyl estradiol (EE2) and estriol (E3), for determination using an electrochemical sensor based on reduced graphene oxide (rGO) and molecularly imprinted polymer (MIP). The analytical method developed, allied with the experimental and operational optimizations, proved to be effective for the total quantification of the EPCs in river water. The method shows sensitivity of 1.12 μA/μmol L−1, detection limit of 26.8 nmol L−1 and linear range of 0.16–15 μmol L−1. The similar electrochemical behavior of the four compounds studied (E1, E2, EE2 and E3) and the efficiency of the modified composite (rGO, MIP) in the fabrication of the sensor resulted in high electrical conductivity and selective adsorptivity, respectively.  相似文献   

7.
《Electroanalysis》2018,30(8):1678-1688
In this work, an electrochemical sensor was constructed by applying two successive thin layers of glycine‐carbon nanotubes mixture and β‐cyclodextrin (CNTs‐Gly)/CD over glassy carbon electrode surface for some neurotransmitters determination. A host‐guest interaction between CD and neurotransmitters molecules is expected and resulted in enhanced sensitivity, selectivity and stability of sensor response. Other components of the sensor are crucial for the unique electrochemical response. Carbon nanotubes allowed large surface area for glycine distribution that provided hydrogen bonding to CD moieties and contributed to facilitated charge transfer. It was possible to determine 3,4‐dihydroxy phenyl acetic acid (DOPAC) in the linear range of 0.1 μmol L−1 to 80 μmol L−1 with detection limit of 9.40 nmol L−1, quantification limit of 31.5 nmol L−1 and sensitivity of 4.16 μA/μmol L−1. The proposed sensor was applied in synthetic cerebrospinal fluids samples using random standard addition method. Also, the proposed sensor was used to determine DOPAC in presence of common interferences and acceptable recovery results were achieved for its analysis in real blood serum. Figures of merit for (CNTs‐Gly)/CD composite in terms of precision, robustness, repeatability and reproducibility were reported.  相似文献   

8.
A new electrochemical sensor based on a carbon nanotube paste electrode modified with a Santa Barbara Amorphous material (SBA-15) decorated with silver nanoparticles, namely CNT/SBA/Ag-PE, was developed. It was successfully applied for individual and simultaneous determination of both paracetamol (PC) and sulfamethoxazole (SMZ) medicines. The electrode exhibited a linear dynamic range of 0.12–110 μmol L−1 for paracetamol and 0.06–70 μmol L−1 for sulfamethoxazole, and detection limits of 38 and 19 nmol L−1, respectively. The proposed sensor offered high sensitivity, fast response time and the potential for detecting both drugs simultaneously. The CNT/SBA/Ag-PE enabled the simultaneous determination of PC and SMZ in urine samples with high recovery rates.  相似文献   

9.
A new and simple photoelectrochemical (PEC) sensor using a glassy carbon electrode (GCE) modified with bismuth vanadate (BiVO4) nanoparticles and dihexadecyl phosphate (DHP) film was useful for acetaminophen (AC) determination. In 0.2 mol L−1 phosphate buffer (pH=9), the GCE without modification exhibited the smaller photocurrent (0.86 μA) when compared with GCE modified with 1.0 mg mL−1 or 2.0 mg mL−1 BiVO4 nanoparticles suspension (5.9 and 34 μA, respectively). Based on the photocurrent signal generated through the interaction between GCE, BiVO4 and the energy of visible light a chronoamperometric method for AC determination was developed. The AC linear range concentration from 0.099 to 0.99 μmol L−1 and limits of detection and quantification of 0.027 and 0.091 μmol L−1, respectively, was obtained. The proposed method was applied to the AC determination in commercial drugs and tap water with satisfactory accuracy and precision. Moreover, the PEC construction was easy and had a short response time, which might confer higher sample throughput for the method.  相似文献   

10.
《Electroanalysis》2003,15(9):787-796
The use of [Cu(bipy)2]Cl2?6H2O as a biomimetic catalyst in the construction of an amperometric sensor for dopamine determination is reported. The sensor was prepared modifying a glassy carbon electrode with a Nafion membrane doped with [Cu(bipy)2]Cl2?6H2O complex. The sensor presented a higher response in 0.25 mol L?1 phosphate buffer solution (pH 7.0), with an applied potential of ?50 mV (vs. SCE). In the optimized operational conditions, a linear response range between 35 and 240 μmol L?1, with a sensitivity of 2.02±0.07 nA l μmoL?1 cm?2 and detection limit of 8.0 μmol L?1 were typically observed for the sensor. The response time presented for this sensor was 0.5 s, presenting the same response for at least 40 successive measurements, with good repeatability (3.0%) expressed as relative standard deviation for n=6. The difference of the response between four sensor preparations was 4%. A detailed investigation about the sensor response for other sixteen phenolic compounds and interfering species were carried out. The sensor was applied in the determination of dopamine in pharmaceutical preparation with success.  相似文献   

11.
《Electroanalysis》2018,30(8):1870-1879
A portable electroanalytical system applied for rapid and simultaneous determination of uric acid (UA) and nitrite (NIT) in human biological fluids (urine, saliva and blood) is reported. The system is based on batch‐injection analysis with multiple‐pulse amperometric (BIA‐MPA) detection using screen‐printed electrodes (SPEs) modified with multi‐walled carbon nanotubes. Sample dilution in optimized electrolyte (0.1 mol L−1 Britton‐Robinson buffer pH 2) followed by injection of 100 μL on the electrode surface using an electronic micropipette is performed. UA is detected at +0.45 V and both UA+NIT at +0.70 V. Linear calibration plots for UA and NIT were obtained over the range of 1–500 μmol L−1 with detection limits of 0.05 and 0.06 μmol L−1, respectively. For comparison, a differential‐pulse voltammetric (DPV) method was optimized, and linear calibration plots for UA and NIT were obtained over range of 1–30 μmol L−1 and 1–40 μmol L−1 with detection limits of 0.1 and 0.3 μmol L−1, respectively. BIA‐MPA is highly precise (RSD<1.3 %), fast (160 h−1) and free from sample‐matrix interferences as recovery values ranged from 77 to 121 % for spiked samples (short contact time of sample aliquot with SPE). Contrarily, recovery tests conducted using DPV did not provide adequate recovery values (>150 %), probably due to the longer contact time of the SPE with the biological samples during analysis leading to a severe interference of sample matrices.  相似文献   

12.
A comparison of the analytical performances of four different (bio)sensor designs in H2O2 determination is discussed. The (bio)sensor designs developed were based on the use of (i) multiwalled carbon nanotubes (MWCNT), zinc oxide nanoparticles (ZnONP), prussian blue (PB); (ii) MWCNT, ZnONP, PB and ionic liquid (IL); (iii) MWCNT, ZnONP and horseradish peroxidase (HRP) and (iv) MWCNT, ZnONP, HRP and IL modified glassy carbon electrode (GCE). A performance comparison of (bio)sensors showed that the one based on HRP/IL-MWCNT-ZnONP/GCE showed the best analytical characteristics with a linear dynamic range of 9.99×10−8–7.55×10−4 M, detection limit of 1.37×10−8 M and sensitivity of 17.00 μA mM−1.  相似文献   

13.
The present work explores, for the first time, the electrocatalytic oxidation of ascorbic acid (AscH2) and its determination in the presence of uric acid (UA) on the in situ activated 4‐nitrophthalonitrile modified carbon paste electrode. The kinetic constant κ for the catalytic reaction for the electrocatalytic oxidation of ascorbic acid, evaluated by cyclic voltammetry, chronoamperometry and RDE voltammetry provided values around 106 L mol?1 s?1. The sensor provided a linear response range for AscH2 and UA from 5.0 up to 120.0 μmol L?1 with detection limits of 1.6 μmol L?1and 1.3 μmol L?1, respectively. The sensor was applied for the simultaneous determination of AscH2 and UA in urine samples and the average recoveries for these samples were 99.8 (±3.1)% and 99.9 (±2.1)%, respectively .  相似文献   

14.
《Electroanalysis》2017,29(7):1691-1699
The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron‐doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton‐Robinson buffer, pH 2. The results obtained by square‐wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1–100 μg mL−1 (4.3×10−6–4.3×10−4 mol L−1) and 10–175 μg mL−1 (4.9×10−5–8.5×10−4 mol L−1), with detection limits of 0.14 μg mL−1 (6.0×10−7 mol L−1) and 1.35 μg mL−1 (6.6×10−6 mol L−1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health‐caring purposes.  相似文献   

15.
《Electroanalysis》2017,29(12):2810-2817
In this study, the synthesis and characterization of a Cu‐based metal‐organic framework (MOF) [Cu3(BTC)2(H2O)3]n (where BTC=benzene‐1,3,5‐tricarboxylate), known as HKUST‐1, were performed. The Cu‐MOF was applied in the modification of a carbon paste to obtain a biomimetic sensor for the electrochemical determination of catechol. Kinetic assays confirmed that the Cu‐MOF acts as a catalyst for the oxidation of catechol and it can be considered as a catechol oxidase mimetic. Under optimized conditions, the calibration curve for catechol presented a linear range of 8.0×10−7 to 3.2×10−5 mol L−1, with detection limit of=1.0×10−7 mol L−1. The sensor demonstrated good intra‐day repeatability and inter‐electrode reproducibility (relative standard deviations of 3.8 % (n=10) and 4.3 % (n=6), respectively). In the selectivity study, an adequate peak‐to‐peak separation was observed for hydroquinone and uric acid in relation to catechol, demonstrating that this sensor has the potential for use in the simultaneous determination of these compounds. This sensor was successfully applied in the determination of catechol in water samples.  相似文献   

16.
《Electroanalysis》2018,30(8):1750-1756
Herein is described the development of a self‐powered sensor for gallic acid (GA) determination exploiting CdSe/ZnS quantum dot sensitized TiO2 nanoparticles (CdSe/ZnS/TiO2/FTO) as photoanode and an all copper oxide photocathode (CuO/Cu2O/FTO) to reduce water. A two‐chamber self‐powered photoelectrochemical cell was employed in order to maintain separated the photoelectrodes. The self‐powered photoelectrochemical cell is based on water reduction in the cathodic chamber while gallic acid acts as a hole scavenger in the anodic chamber to generate the necessary cell output to drive GA oxidation in the anodic compartment. Electrochemical impedance measurements were performed to evaluate the electronic characteristics of CdSe/ZnS/TiO2/FTO photoanode and CuO/Cu2O/FTO photocathode in terms of flat band potential, carrier density, and nature of semiconductor. Under optimized conditions, the self‐powered photoelectrochemical cell presented a wide linear response range for GA from 1 μmol L−1 up to 200 μmol L−1.  相似文献   

17.
An effective electrochemical sensor was constructed using an unmodified boron-doped diamond electrode for determination of genistein by square-wave voltammetry. Cyclic voltammetric investigations of genistein with HClO4 solution indicated that irreversible behavior, adsorption-controlled and well-defined two oxidation peaks at about +0.92 (PA1) & +1.27 V (PA2). pH, as well as supporting electrolytes, are important in genistein oxidations. Quantification analyses of genistein were conducted using its two oxidation peaks. Using optimized experiments as well as instrumental conditions, the current response with genistein was proportionately linear in the concentrations range of 0.1 to 50.0 μg mL−1 (3.7×10−7−1.9×10−4 mol L−1), by the detection limit of 0.023 μg mL−1 (8.5×10−8 mol L−1) for PA1 and 0.028 μg mL−1 (1.1×10−7 mol L−1) for PA2 in 0.1 mol L−1 HClO4 solution (in the open circuit condition at 30 s accumulation time). Ultimately, the developed method was effectively applied to detect genistein in model human urine samples by using its second oxidation peak (PA2).  相似文献   

18.
We propose an electrochemical sensor based on applying two successive thin layers from a mixture of multiwalled carbon nanotubes‐ionic liquid crystal and crown ether at glassy carbon electrode surface (GC/(CNTs‐ILC)/Crown). The sensor was used for sensitive determination of neurotransmitters based on effective synergism between its components. The compact conducting surface of (CNTs ‐ ILC) with large surface area allowed the assembling of stable host‐guest inclusion complexes between crown ethers and neurotransmitters. The GC/(CNTs‐ILC)/Crown exhibited excellent electro‐catalytic activity toward the determination of serotonin (ST) in a wide linear dynamic range: 0.005 μmol L?1 to 100 μmol L?1. In the concentration range 0.005 μmol L?1 to 1 μmol L?1, the detection limit is 2.03×10?10 mol L?1 and quantification limit is 6.78×10?10 mol L?1 with correlation coefficient 0.999. The sensor was successfully applied for ST detection in human serum samples with satisfied recovery results. The sensor showed excellent analytical performance for the determination of ST in terms of low detection limit, good sensitivity and reproducibility. Furthermore excellent anti‐interference ability and simultaneous determination of ST in presence of other compounds as ascorbic acid, dopamine and antidepressant drug were achieved.  相似文献   

19.
Simple and rapid voltammetric method for simultaneous determination of all-trans-retinyl acetate (RAc) or all-trans-retinyl palmitate (RPa) and α-tocopheryl acetate (α-TOAc) has been proposed. The respective method was based on the anodic oxidation of the compounds of interest by square-wave voltammetry in acetone with 0.1 mol L−1 LiClO4 at the glassy carbon electrode. The procedure was also beneficial with respect to simple dissolution of sample directly in the supporting electrolyte. The all-trans-retinyl acetate could be quantified in two linear ranges (3.1–140 μmol L−1 and 140–400 μmol L−1) and α-tocopheryl acetate in linear range 5.3–400 μmol L−1 with detection limits of 0.9 μmol L−1 RAc (or 0.8 μmol L−1 RPa) and of 1.6 μmol L−1 α-TOAc. Selected commercial cosmetic products were analysed achieving satisfactory recoveries.  相似文献   

20.
《Electroanalysis》2017,29(8):1968-1975
Hybrid magnetite/carbon quantum dots (MagNP/C‐dots) were prepared and their characterization performed by high resolution transmission electron microscopy (HR‐TEM), X‐ray diffraction (XRD) and X‐ray photoelectron spectroscopy (XPS). Because of their suitable magnetization and electrochemical properties, they were used as versatile electrode modifiers after magnetically confining onto screen printed carbon electrodes (SPE), with the aid of a miniature external magnet. The reported strategy introduces a convenient procedure for assembling modified electrodes, since the nanoparticles can be easily released by removing the magnet. The non‐enzymatic magnetic biosensor showed excellent performance in the determination of NADH at the concentration range 2×10−7 to 5×10−6 mol L−1, exhibiting a sensitivity of 0.15 μmol L−1 and detection limit of 20 nmol L−1. The MagNP/C‐dots/SPE sensor was also successfully applied for the determination of NADH in serum samples. The interference of typical biological molecules has also been investigated.  相似文献   