A sensitive electrochemical method was developed for the determination of bisphenol A (BPA) at a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (MWCNTs)‐gold nanoparticles (GNPs) hybrid film, which was prepared based on the electrostatic interaction between positively charged cetyltrimethylammonium bromide (CTAB) and negatively charged MWCNTs and GNPs. The MWCNT‐GNPs/GCE exhibited an enhanced electroactivity for BPA oxidation versus unmodified GCE and MWCNTs/GCE. The experimental parameters, including the amounts of modified MWCNTs and GNPs, the pH of the supporting electrolyte, scan rate and accumulation time, were examined and optimized. Under the optimal conditions, the differential pulse voltammetric anodic peak current of BPA was linear with the BPA concentration from 2.0×10?8 to 2×10?5 mol L?1, with a limit of detection of 7.5 nmol L?1. The proposed procedure was applied to determine BPA leached from real plastic samples with satisfactory results.  相似文献   

2.
《Electroanalysis》2017,29(3):708-715
The wide use of pesticides can lead to environmental and human adverse effects. Diazinon, as an organophosphorous pesticide, is used in agriculture because of its low cost and high efficiency on insects. Due to the increasing application of pesticides, accurate analytical methods are necessary. The aim of this work was modification of carbon paste electrode composition and applying it as a sensor for determination of diazinon in biological and environmental samples. Multi‐walls carbon nanotubes and a molecularly imprinted polymer were used as modifiers in the sensor composition. A molecularly imprinted polymer and a non‐imprinted polymer were synthesized for applying in the electrode. After optimization of electrode composition, it was used to determine the analyte concentration. Instrumental parameters affecting the square wave voltammetric response were adjusted to obtain the highest current intensity. The modified electrode with MIP showed very high recognition ability compared to the electrode containing NIP. The obtained linear range was 5×10−10 to 1×10−6 mol L−1. The detection limit of the sensor was 1.3×10−10 mol L−1 and the relative standard deviation for analysis of target molecule by the proposed sensor was 2.87 %. This sensor was used to determine the diazinon in real samples (human urine, tap, and river water samples) without special sample preparation before analysis. The optimization of electrode composition containing mentioned modifiers improved its response considerably.  相似文献   

3.
《Electroanalysis》2017,29(3):907-916
A porous electrode material combining the features of vertically aligned multi‐walled carbon nanotubes (VAMWCNT) and diamond‐like carbon films (DLC) have been developed for a highly sensitive electrochemical sensor. For working electrode preparation, DLC has been grown onto VAMWCNT, forming a porous, conductive and stable composite. The electrochemical performance of this DLC:VAMWCNT electrode has been investigated toward detection and analysis of three well‐known molecules, namely paracetamol, codeine and caffeine. A ternary mixture of these analytes was simultaneously determined under optimum experimental conditions using square‐wave voltammetry. Wide linear concentration ranges and the limits of detection of 3.34×10−7 mol L−1, 1.57×10−7 mol L−1 and 3.67×10−7 mol L−1 were obtained for paracetamol, codeine and caffeine, respectively. We conclude that the proposed voltammetric method and the DLC:VAMWCNT electrode comprise a reliable methodology for simultaneous determination of paracetamol, codeine and caffeine in biological matrix samples.  相似文献   

4.
Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4‐vinyl pyridine (4‐VP) or methacrylic acid (MAA) monomers in the presence of a cross‐linker. CMQ was used as template. Similar non‐imprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4‐VP exhibited the best performance, presenting fast near‐Nernstian response for CMQ over the concentration range 6.2×10−6–1.0×10−2 mol L−1 with detection limits of 4.1×10−6 mol L−1. The sensor was independent from the pH of test solutions in the range 5–10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQ in commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.  相似文献   

5.
In the present work, an electrochemical sensor was developed for simple and sensitive determination of tryptophan (Trp) using multi‐walled carbon nanotubes modified sol‐gel electrode (MWCNTs/SGE). The electrocatalytic oxidation of tryptophan was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the oxidation peak current of Trp at the MWCNTs/SGE was greatly improved compared with that of the bare SGE. Furthermore, at the MWCNTs/SGE, the anodic peak potential of Trp is shifted about 220 mV to more negative value indicated that modified electrode has better electrocatalytic activity for electro‐oxidation of Trp. The anodic peak currents increased linearly with the concentration of tryptophan in the range of 0.2 × 10?6 to 15 × 10?6 M with a detection limit of 0.139 × 10?6 M (at an S/N = 3).  相似文献   

6.
《Electroanalysis》2017,29(2):635-642
An electrochemical sensor for paracetamol (PC) based on the hexacyanoferate(III) intercalated Ni−Al layered double hydroxide (Ni−Al−HCF) was presented. The as‐prepared LDH structurally and morphologically was characterized by scanning electron microscopy, X‐ray diffraction, and Fourier transform IR. Electrochemical studies revealed that Ni−Al−HCF film modified glassy carbon (GC) electrode exhibited remarkable electrocatalytic activity toward the oxidation of paracetamol. The electrochemical behavior of PC on the Ni−Al−HCF film was investigated in detail. Under optimum experimental conditions, the electrocatalytic response of the modified GC electrode was linear in the PC concentration range 3×10−6−–1.5×10−3 mol L−1, with a detection limit of 8×10−7 mol L−1 (S/N=3), using hydrodynamic amperometry. In addition, the modified electrode exhibited good reproducibility, long‐term stability and anti‐interference property. The fabricated sensor was successfully applied to determination of PC in various pharmaceutical preparations such as tablets, oral solution, and oral drops. Finally, the method was validated by the analysis of paracetamol spiked human serum samples, and good recoveries were obtained in the range of 99.2–103 %.  相似文献   

7.
A novel electrode was fabricated for the quantitation of Fe2+ ion. It was based on the covalent attachment of the gemifloxacin molecule (the recognition element) to the surface of MWCNTs to be incorporated as an electroactive material. Linear response of Fe2+ ions was found in the concentration range of 1×10−2 mol L−1 to 1×10−8 mol L−1 with a Nernstian slope of 30.37 ±0.3 (mV/decade) and attained a stable response within 5 s. The sensor exhibited LOD value of 4.8×10−9 mol L−1. It was applied in the monitoring of Fe2+ concentration in multi-vitamins tablets, tap water and milk samples with acceptable recovery ranged from 94.00 % to 102.00 %.  相似文献   

8.
《Electroanalysis》2018,30(8):1837-1846
This study reports a highly sensitive electrochemical sensor based on Bi film modified glassy carbon electrode (BiF/GCE) for total determination and speciation trace concentrations of copper(II) ions in environmental water samples. Square wave‐adsorptive anodic stripping voltammetric (SW‐ASV) experiment was performed for monitoring selective accumulation of copper(II) with reagent 3‐[(2‐mercapto‐vinyl)‐hydrazono]‐1,3‐dihydro‐indol‐2‐one (MHDI) at pH 9–10. The mechanism of the electrode reaction of Cu2+‐MHDI complex was safely assigned. The sensor exhibited a wide linear range (3.22×10−9–2.0×10−7 mol L−1) with lower limits of detection (LOD) and quantitation (LOQ) of 9.6×1−10 and 3.22×10−9 mol L−1, respectively (R2=0.9993). The proposed sensor exhibited interference from active metal ions e. g. Cd, Hg. The performance of the proposed method was compared successfully with most of the reported methods and comparable efficiencies were obtained. The analytical utility of the proposed SW‐ASV method has been successfully validated for trace analysis of copper(II) in environmental water samples. The method offers a precise, accurate approach with good reproducibility, robustness, ruggedness, and cost effectiveness.  相似文献   

9.
《Electroanalysis》2017,29(3):835-842
A novel electrochemically activated doped Ta2O5 particles modified carbon paste electrode (EA‐Ta2O5‐CPE) was prepared and applied for selective and sensitive determination of chrysin. X‐ray diffraction (XRD), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) techniques and cyclic voltammetry (CV) were used to characterize the Ta2O5 particles and investigate the electrochemical response of the sensor. Compared with bare CPE, the doped Ta2O5 modified electrode got much more porous by electrochemical treatment and exhibited larger effective surface area, more reactive site and excellent electrochemical catalytic activity toward the oxidation of chrysin. Under optimum conditions by LSV, the oxidation peak currents responded to chrysin linearly over a concentration range from 5.0×10−8 to 7.0×10−6 mol L−1 with a detection limit of 2.0×10−8 mol L−1 (5.08 ng mL−1). The fabricated sensor showed anti‐interference ability against the biological common interferents (i.e. baicalein, baicalin) and provided to be reliable for the determination of chrysin in Chinese medicinal herb Oroxylum indicum and chrysin capsules samples with satisfactory results.  相似文献   

10.
A novel electrochemical sensor for the determination of bisphenol A (BPA) was fabricated by block polyelectrolyte composite films, which composed of diblock polyelectrolyte poly (2-hydroxyethyl methacrylate)-b-poly (2-(dimethylamino) ethyl methacrylate) (PHEMA-b-PDMAEMA, noted as PHD in the later content) and multi-walled carbon nanotubes (MWCNTs). The tertiary amino groups of PDMAEMA can be protonated at physiological pH. The protonated PDMAEMA can thus interact with the negatively charged BPA through electrostatic attraction to increase the BPA sorption capacity and enhance the ability for highly sensitive detection of BPA. The PHD/MWCNTs composite films combine the electrocatalytic property of MWCNTs and the electrostatic attraction of protonated PHD. Because of the above-mentioned excellent property of the composite films, the PHD/MWCNTs/glassy carbon electrode exhibited good electrocatalytic activity to electrooxidation of BPA. The wide linear response range of the BPA sensor was from 4.56 × 10?5 g L?1 to 2.28 × 10?2 g L?1 with a lower detection limit of 2.28 × 10?6 g L?1 (S/N = 3) and high sensitivity 2442.86 μA L g?1 cm?2. The current reached the steady-state current with a shorter response time less than 4 s. The proposed method was successfully applied to determine BPA in real samples (PVC food package, milk, tap water and pond water) and satisfactory results were obtained. These results indicated that the block polyelectrolyte composite have potential applicability of the BPA sensor.  相似文献   

11.
In this study, a molecularly imprinted electrochemical sensor (MIP/DA) was investigated for selective and sensitive determination of dopamine (DA) by electrochemical polymerization of p-aminothiophenol in the presence of DA on gold electrode. According to electrochemical behaviour of the sensor, gained through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), MIP/DA sensor showed distinctive electron transfer characteristics in comparison to the non-imprinted (NIP/DA) sensor. Besides the MIP/DA sensor showed high selectivity for dopamine through its analyte specific cavities. The sensor had a broad working range of 5.0×10−8–2.0×10−7 M with a limit of detection (LOD) of 1.8×10−8 M and the developed sensor was successfully applied for determination of dopamine in pharmaceutical samples.  相似文献   

12.
In this study, for the first time, the electro-polymerization of Direct blue15 (DB15), an azo dye, was carried out on the surface of ITO. Furthermore, the poly(DB15) surface was electrochemically decorated with Ag nanoparticles (AgNPs), and the fabricated AgNPs/PDB15 electrodes were examined as nitrate sensors. Compared to unmodified ITO electrode, the AgNPs/PDB15 electrode had greatly improved electrochemical response to nitrate reduction. The nitrate determination in a linear range from 1.0×10−5 mol L−1 to 2.27×10−3 mol L−1 was performed with a detection limit of 9.66 μM. The synthesized electrode is a promising sensor for the electrochemical detection of nitrate pollutants in water.  相似文献   

13.
《Electroanalysis》2017,29(2):566-577
Two novel carbon paste electrodes based on gentamicin‐reineckate (GNS‐RN)/multiwall carbon nanotubes (MWCNTs)/sodium tetraphenyl borate (NaTPB) or potassium tetraphenylborate (KTPB) for potentiometric determination of gentamicin sulfate were constructed. Our endeavors of lowering the detection limit for gentamicin ion‐selective electrodes were described. The paper focused on gentamicin carbon paste electrodes based on GNS‐RN as electroactive material, o ‐nitrophenyloctyl ether (o ‐NPOE) as plasticizer and incorporation of MWCNTs and lipophilic anionic additives (NaTPB and KTPB) which lower the detection limit of the electrodes showing best results for determination of gentamicin ion. The characteristics of the electrodes, GNS‐RN+NaTPB+MWCNTs (sensor 1) and GNS‐RN+KTPB+ MWCNTs (sensor 2), were measured, showing favorable features as they provided measurements of the potential with near‐Nernstian slopes of 29.6±0.3 and 29.1±0.3 mV/decade over the concentration range of 1.0×10−6–1.0×10−2 mol L−1 and pH ranges 3.0–8.2 and 3.0–8.0 in short response times (6.5 sec). Importantly, the electrodes had low detection limits of 3.0×10−7and 3.4×10−7 mol L−1 for the two sensors, respectively. The sensors showed high selectivity for gentamicin ion with respect to a large number of interfering species. The electrodes were successfully applied for the potentiometric determination of GNS ions in pure state, pharmaceutical preparations and human urine with high accuracy and precision. The results of this study were compared with some previously published data using other analytical methods.  相似文献   

14.
This study reports a comparison of adsorptive transfer and solution phase voltammetric methods for the study of caffeic acid. For this purpose, a platform was prepared by the modification of glassy carbon electrodes (GCEs) with MWCNTs and samarium nanoparticles (SmNPs) by means of an ultrasonic bath. The surface morphology of the platform was characterized using SEM, EDX and XRD. The adsorptive transfer voltammetric method was based on the adsorption of caffeic acid (CFA) at the surface of the modified electrode by keeping it into a solution of CFA. Afterwards, the modified electrode was transferred with the adsorbed species in a cell containing only 0.1 mol L−1 phosphate buffer solution (PBS) for the analysis. The current response of CFA was found to be linear over a concentration from 5.0 × 10−10 mol L−1 to 1.0 × 10−7 mol L−1. The values of the limit of detection (LOD) and limit of quantification (LOQ) were 2.0 × 10−10 mol L−1 and 6.67 × 10−10 mol L−1, respectively. The adsorptive transfer method using the modified electrode (SmNPs/MWCNTs/GCE) has successfully been applied to food samples for determining CFA. The solution phase voltammetry was carried out by dipping the electrode into a voltammetric cell containing CFA. The plot of peak currents was linear over the concentration range of 5.0 × 10−9 mol L−1 –8.0 × 10−8 mol L−1. The values of LOD and LOQ were 2.0 × 10−9 mol L−1 and 6.67 × 10−9 mol L−1 for CFA using a classical solution phase voltammetry at the proposed platform. It was shown that the LOD obtained at adsorptive transfer voltammetry was 10-fold lower when compared to classical solution phase voltammetry.  相似文献   

15.
《Electroanalysis》2017,29(5):1459-1468
A UO22+‐PVC membrane electrode was constructed using 2‐thenoyltrifluoroacetone as ionophore and its electrochemical response performance was characterized. The effect of membrane composition on the electrode performance was studied and best results were obtained using dioctylsebacate as a mediator and potassium tetrakis(4‐chlorophenyl)borate as anion excluder. The optimized UO22+‐sensor exhibited a Nernstian response with a slope of 29.5±0.5 mV decade−1 over the concentration range 5.0×10−7−1.0×10−1 mol L−1 at 25 °C with a detection limit of 3.1×10−7 mol L−1. The optimized electrode showed very good selectivity towards UO22+ relative to a wide variety of other cations and fast response time. Surface morphology of the optimized membrane electrode at different stages of its development and use was investigated and discussed. Quantum chemical calculations for geometrical optimization of the ionophore were carried out to investigate the interaction between the ionophore and UO22+ using DFT B3LYP/6‐31++G(d,p) level of theory and the obtained data confirmed the proposed response mechanism. The developed sensor was successfully applied for UO22+ selective determination in real water samples and the obtained results were compared to those obtained by spectrophotometric method indicating no significant difference.  相似文献   

16.
《Electroanalysis》2017,29(2):506-513
A simple and highly sensitive sensor has been used for the determination of oxomemazine hydrochloride (OXO) in presence of paracetamol (PAR) and guaifenesin (GU). Carbon paste electrode was modified with multiwalled carbon nanotube (MWCNT), alizarine red S (AZ) and chitosan (CH). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to characterize the nanostructure and performance of the sensor. Under the optimized experimental conditions OXO gave linear response over the range of 2.00×10−6–1.00×10−4 mol L−1. The detection limit was found to be 4.35×10−7 mol L−1. The practical application of the modified electrode was demonstrated by measuring the concentration of OXO in pharmaceutical samples and urine. This revealed that suggested sensor shows excellent analytical performance for the determination of OXO in terms of a very low detection limit, high sensitivity and selectivity.  相似文献   

17.
《Electroanalysis》2017,29(12):2810-2817
In this study, the synthesis and characterization of a Cu‐based metal‐organic framework (MOF) [Cu3(BTC)2(H2O)3]n (where BTC=benzene‐1,3,5‐tricarboxylate), known as HKUST‐1, were performed. The Cu‐MOF was applied in the modification of a carbon paste to obtain a biomimetic sensor for the electrochemical determination of catechol. Kinetic assays confirmed that the Cu‐MOF acts as a catalyst for the oxidation of catechol and it can be considered as a catechol oxidase mimetic. Under optimized conditions, the calibration curve for catechol presented a linear range of 8.0×10−7 to 3.2×10−5 mol L−1, with detection limit of=1.0×10−7 mol L−1. The sensor demonstrated good intra‐day repeatability and inter‐electrode reproducibility (relative standard deviations of 3.8 % (n=10) and 4.3 % (n=6), respectively). In the selectivity study, an adequate peak‐to‐peak separation was observed for hydroquinone and uric acid in relation to catechol, demonstrating that this sensor has the potential for use in the simultaneous determination of these compounds. This sensor was successfully applied in the determination of catechol in water samples.  相似文献   

18.
《Electroanalysis》2017,29(8):1968-1975
Hybrid magnetite/carbon quantum dots (MagNP/C‐dots) were prepared and their characterization performed by high resolution transmission electron microscopy (HR‐TEM), X‐ray diffraction (XRD) and X‐ray photoelectron spectroscopy (XPS). Because of their suitable magnetization and electrochemical properties, they were used as versatile electrode modifiers after magnetically confining onto screen printed carbon electrodes (SPE), with the aid of a miniature external magnet. The reported strategy introduces a convenient procedure for assembling modified electrodes, since the nanoparticles can be easily released by removing the magnet. The non‐enzymatic magnetic biosensor showed excellent performance in the determination of NADH at the concentration range 2×10−7 to 5×10−6 mol L−1, exhibiting a sensitivity of 0.15 μmol L−1 and detection limit of 20 nmol L−1. The MagNP/C‐dots/SPE sensor was also successfully applied for the determination of NADH in serum samples. The interference of typical biological molecules has also been investigated.  相似文献   

19.
《Electroanalysis》2018,30(9):1946-1955
In this paper, a rapid and sensitive modified electrode for the simultaneous determination of hydroquinone (HQ) and bisphenol A (BPA) is proposed. The simultaneous determination of these two compounds is extremely important since they can coexist in the same sample and are very harmful to plants, animals and the environment in general. A carbon paste electrode (CPE) was modified with silver nanoparticles (nAg) and polyvinylpyrrolidone (PVP). The PVP was used as a reducing and stabilizing agent of nAg from silver nitrate in aqueous media. The nAg‐PVP composite obtained was characterized by transmission electron microscopy and UV‐vis spectroscopy. The electrochemical behavior of HQ and BPA at the nAg‐PVP/CPE was investigated in 0.1 mol L−1 B−R buffer (pH 6.0) using cyclic voltammetry (CV) and square wave voltammetry (SWV). The results indicate that the electrochemical responses are improved significantly with the use of the modified electrode. The calibration curves obtained by SWV, under the optimized conditions, showed linear ranges of 0.09–2.00 μmol L−1 for HQ (limit of detection 0.088 μmol L−1) and 0.04–1.00 μmol L−1 for BPA (limit of detection 0.025 μmol L−1). The modified electrode was successfully applied in the analysis of water samples and the results were comparable to those obtained using UV‐vis spectroscopy.  相似文献   

20.
《Electroanalysis》2018,30(2):288-295
Methotrexate (MTX) was used as an anti‐cancer drug, but its excessive use can cause serious side effects, it was necessary to monitor MTX in vivo. In this report, DNA was immobilized on a glassy carbon electrode (GCE) modified with graphene oxide (GO) to develop an electrochemical sensor for sensitive determination of MTX for the first time. The adsorptive voltammetric behaviors of MTX on DNA sensor were investigated using differential pulse voltammetry (DPV). The peak current response of guanine in DNA was used as a determination signal of MTX in acetate buffer solution pH 4.6. Voltammetric investigations revealed that the proposed method could determine MTX in the concentration range from 5.5×10−8 to 2.2×10−6 mol L−1 with a lower detection limit of 7.6×109 mol L−1 (S/N=3). The method was applied to detect MTX in human blood serum and diluted urine samples with excellent recoveries of 97.4–102.5 %. Compared with the previous studies, the DNA/GO/GCE electrode constructed by us based on the change rate of guanine current (R%) in DNA, proportionally reflecting the MTX concentration, is simple and sensitive .  相似文献   