首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

2.
A rapid and sensitive analytical method based on liquid chromatography coupled to tandem mass spectrometry detection with positive ion electrospray ionization was developed for the determination of febuxostat in human plasma using d7‐febuxostat as the internal standard (IS). A simple protein precipitation was performed using acetonitrile. The analyte and IS were subjected to chromatographic analysis on a Capcell PAK C18 column (4.6 × 100 mm, 5 µm) using acetonitrile–5 mm ammonium acetate–formic acid (85:15:0.015, v/v/v) as the mobile phase at a flow rate of 0.6 mL/min. An Agilent 6460 electrospray tandem mass spectrometer was operated in the multiple reaction monitoring mode. The precursor‐to‐product ion transitions m/z 317 → m/z 261 (febuxsotat) and m/z 324 → m/z (261 + 262) (d7‐febuxostat, IS) were used for quantitation. The results were linear over the studied range (10.0–5000 ng/mL), and the total analysis time for each chromatograph was 3 min. The intra‐ and inter‐day precisions were less than 7.9 and 7.2%, respectively, and the accuracy was within ±4.2%. No evidence of analyte instability in human plasma was observed storage at ?20°C for 31 days. This method was successfully applied in the determination of febuxostat concentrations in plasma samples from healthy Chinese volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Tetrodotoxin (TTX) exhibits the therapeutic potential in blocking pain and in low doses can safely relieve severe pain. The urinary excretion profiles of TTX in humans have not been reported due to the extremely low lethal dose. In this study, a rapid and specific method based on protein precipitation coupled to liquid chromatography tandem mass spectrometry was developed to determine the level of TTX in human urine samples. 11-Deoxytetrodotoxin was used as an internal standard (IS). Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 320.0 → 162.1 for TTX and m/z 304.0 → 176.0 for 11-deoxyTTX. The separation of analytes was achieved on a hydrophilic interaction liquid chromatography column (250 × 4.6 mm, 5.0 μm). The mobile phase consisted of 5 mM ammonium formate in water (pH = 4.50) and 5 mM ammonium formate in acetonitrile (pH = 4.50). The flow rate was set at 0.80 mL/min in a gradient condition. Calibration plots were linear throughout the range 0.986–98.6 ng/mL of TTX in human urine. The intra-assay accuracies and precisions were within the acceptable range. The method was successfully applied to a urinary excretion study after intravenous administration of TTX to healthy volunteers. The developed method will be helpful for future pharmacological studies of TTX.  相似文献   

4.
Maleic hydrazide has been extensively used as an effective growth regulator in tobacco sucker control. After application, maleic hydrazide distributes itself throughout the tobacco plant where it can exist as free, or forms glucoside conjugates with glucose, or becomes bound with lignin. Among them, free maleic hydrazide and its glucoside conjugates are extractable under conventional solvent extraction, while lignin bound maleic hydrazide is claimed to be non‐extractable. Herein, an autoclave extraction method has been developed to extract maleic hydrazide effectively, in which tobacco samples are extracted in an autoclave at 130°C for 1 h using 4 M hydrochloric acid. Under such pressurized hot acidic water conditions, lignin bound maleic hydrazide can be released. Meanwhile, glucoside conjugates are hydrolyzed. Total maleic hydrazide is detected by liquid chromatography coupled with tandem mass spectrometry, and the quantitative results coincide well with that obtained from the international standard method. The proposed autoclave extraction with liquid chromatography and tandem mass spectrometry method exhibits excellent linearity in the range of 5–200 mg/kg (R2 = 0.9998), the matrix matched limit of detection and limit of quantification is 0.68 and 2.27 mg/kg, respectively. This method is simple and improves sample capacity, providing an effective approach to monitoring maleic hydrazide residues in tobacco.  相似文献   

5.
A sensitive and specific liquid chromatography with tandem mass spectrometry method was firstly developed for the measurement of isomangiferin in rat plasma. Chloramphenicol was selected as the internal standard. Sample preparation was carried out through a simple one‐step protein precipitation procedure with methanol. Negative electrospray ionization was performed using multiple reaction monitoring mode with transitions of m/z 421.1/301.1 for isomangiferin, and 321.1/151.9 for chloramphenicol. The calibration curve was linear over the range of 0.1–600 ng/mL, with a lower limit of quantification at 0.1 ng/mL. The intra‐ and interday precisions (relative standard deviation) were no more than 8.2% and accuracies (relative error) were within the range of –8.4 to 2.2%. The recovery, matrix effect and stability under different conditions were all proved acceptable. The validated method has been successfully applied to a preclinical pharmacokinetic study of isomangiferin in rats for the first time.  相似文献   

6.
The dissipation dynamics and final residues of flutriafol on tobacco plant and soil were studied under field conditions. The residues of flutriafol in soil, green tobacco leaves and cured tobacco leaves were extracted by ultrasound-assisted extraction, cleaned up by dispersive solid-phase extraction and detected by liquid chromatography with tandem mass spectrometry. The limits of detection of flutriafol in soil, green tobacco leaves and cured tobacco leaves were 0.006, 0.033 and 0.033 mg·kg?1, respectively. The limits of quantification of flutriafol in soil, green tobacco leaves and cured tobacco leaves were 0.02, 0.1 and 0.1 mg·kg?1, respectively. Recoveries were 72.9–102% with relative standard deviations of less than 12% in soil and tobacco matrix. For field experiments, the half-lives of flutriafol in soil and green tobacco leaves were 9.2–11.5 and 9.5–11.1 days, respectively. At harvest, the final residue levels of flutriafol in cured tobacco leaves collected 21 days after one application at the recommended dosage were below 2.0 mg/kg. The maximum residue limit maximum residue limit (MRL) for flutriafol in tobacco has not yet been established in any countries. The data could help the Chinese Government to establish the MRL of flutriafol in tobacco and provide guidance on the proper use of flutriafol.  相似文献   

7.
An ultrasensitive method for the simultaneous analysis of pesticides residues in tobacco was developed with online size exclusion chromatography with gas chromatography and tandem mass spectrometry. Tobacco samples were extracted with the solvent mixture of cyclohexane and acetone (7:3, v/v) and centrifuged. Then, the supernatant liquors were injected directly into the online size exclusion chromatography with gas chromatography and tandem mass spectrometry without any other purification procedures after being filtered with a 0.22 μm organic phase filter. The matrix interferences were effectively removed and recoveries of most pesticides were in the range of 72–121%. Especially, for chlorothalonil, the analysis efficiency of this method was much more favorable than that of the general method, in which dispersive solid‐phase extraction was used as an additional purified procedure. In addition, the limits of quantitation of this method were from 1 to 50 μg/kg. Therefore, a rapid, cost‐effective, labor‐saving method was proposed in the present work, which was suitable for the analysis of 41 pesticide residues in tobacco.  相似文献   

8.
液相色谱-电喷雾串联质谱法测定生姜中的215种农药残留   总被引:4,自引:1,他引:4  
曹静  庞国芳  王明林  范春林 《色谱》2010,28(6):579-589
建立了生姜中215种农药多残留测定的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法。样品用1%醋酸-乙腈溶液均质提取,经Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(3:1, v/v)洗脱,旋转蒸发浓缩至约0.5 mL后,于室温氮气吹干,用乙腈-水(3:2, v/v)溶解,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。在定量限水平进行添加回收率实验,方法的回收率范围为68.1%~132.6%,其中回收率在70%~120%的占94.4%,相对标准偏差(RSD)范围为0.4%~25.0%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.01~70.45 μg/L和0.04~234.84 μg/L。该方法操作简便,灵敏度、准确度和精密度均符合农药多残留检测技术要求,适用于生姜中215种农药多残留的快速测定。  相似文献   

9.
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (100 × 4.6 mm, 3.5 μm) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60:40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction‐monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10?5000 ng/mL (correlation coefficients, r≥0.9833) in plasma and 5?2500 ng/mL (r≥0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B.  相似文献   

10.
A rapid confirmatory method has been developed and validated for the simultaneous identification, confirmation and quantitation of 11 nitroimidazoles in eggs by liquid chromatography tandem mass spectrometry (LC–MS/MS). The method is validated in accordance with Commission Decision 2002/657/EC and is capable of analysing metronidazole (MNZ), dimetridazole (DMZ), ronidazole (RNZ), ipronidazole (IPZ) and their hydroxy metabolites MNZ-OH, HMMNI (hydroxymethyl, methyl nitroimidazole), IPZ-OH. The method is also capable of analysing carnidazole (CRZ), ornidazole (ORZ), tinidazole (TNZ) and ternidazole (TRZ). MNZ, DMZ and RNZ have been assigned a recommended level (RL) of 3 μg kg−1 by the Community Reference Laboratory (CRL) in Berlin. The developed method described in this study is easily able to detect all the nitroimidazole compounds investigated at this level and below. Egg samples are extracted with acetonitrile, and NaCl is added to help remove matrix contaminants. The acetonitrile extract undergoes a liquid–liquid wash step with hexane; it is then evaporated and reconstituted in mobile phase. The reconstituted samples are analysed by liquid chromatography tandem mass spectrometry (LC–MS/MS). The decision limits (CCα) range from 0.33 to 1.26 μg kg−1 and the detection capabilities (CCβ), range from 0.56 to 2.15 μg kg−1. The results of the inter-assay study, which was performed by fortifying hen egg samples (n = 18) on three separate days, show the accuracy calculated for the various analytes to range between 87.2 and 106.2%. The precision of the method, expressed as %CV values for the inter-assay variation of each analyte at the three levels of fortification (3, 4.5 and 6.0 μg kg−1), ranged between 3.7 and 11.3%. A Day 4 analysis was carried out to examine species variances in eggs from different birds such as duck and quail and investigating differences in various battery and free range hen eggs.  相似文献   

11.
Saikosaponins (SSs) are a class of triterpene saponins with a wide spectrum of bioactivities. A sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed for simultaneous determination of saikosaponin a, saikosaponin c, saikosaponin d and saikosaponin b2 in rat plasma. Plasma samples were prepared by liquid–liquid extraction. The analytes and the internal standard (IS) digoxin were well separated on an octadecyl column using gradient elution and analyzed by monitoring the fragmentation transition pair of anionic adducts to deprotonated molecules in negative‐mode electrospray. By neutral loss of HCOOH, the transition pairs of m/z 825 → 779 for SSa, SSd, SSb2 and the IS, and m/z 971 → 925 for SSc were sensitive for MS/MS detection with the lower limits of quantification in the range of 0.20–0.40 ng/mL. Method validation experiments were performed, including selectivity, precision, accuracy, linearity, matrix effect, recovery and stability. The validated method was further applied to determine the pharmacokinetics parameters of SSa, c and d in rats following a single oral administration of the extract of chaihu (the dried roots of Bupleurum chinense DC). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
An LC‐MS/MS method for determination of the anti‐epileptic drug topiramate (TPM) in dried blood spot (DBS) samples was developed and validated. DBS samples were prepared by spotting 30 μL of spiked whole blood onto FTATM DMPK‐C cards and drying for at least 3 h. Six‐millimetre punched spots were then extracted by using a mixture of methanol and water (90:10, v/v) with deuterated internal standard (topiramate‐d12). The extracted samples were injected into a liquid chromatograph equipped with a tandem mass spectrometric detector. Negative ions were monitored in the selected reaction monitoring mode and transitions m/z 338.2 → 78.1 and m/z 350.3 → 78.1 were used for the quantitative evaluation of TPM and internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of the European Medicines Agency and US Food and Drug Administration regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
建立了牛奶样品中洁霉素、氯洁霉素、红霉素、螺旋霉素、交沙霉素、泰乐菌素、竹桃霉素等7种林可酰胺类及大环内酯类药物残留量的确证方法。用乙腈萃取样品中7种林可酰胺类及大环内酯类抗生素,然后用正己烷脱脂,旋转蒸发仪浓缩,以Luna C18(2)色谱柱分离,在正离子模式下以电喷雾电离串联质谱仪进行测定。在20、50、200μg/kg 3个浓度水平进行验证试验,方法的线性范围为20~200μg/kg,总体平均回收率为74.5%~97.5%,相对标准偏差为2.7%~11.3%。该方法各项技术指标满足国内外法规的要求,可用于牛奶样品中林可酰胺类及大环内酯类抗生素残留量的确证检测。  相似文献   

14.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

15.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

16.
A rapid, sensitive and specific method to quantify bromazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography (HPLC) coupled to electrospray tandem mass spectrometry (MS/MS). Chromatography was performed isocratically on a Genesis C(18) analytical column (100 x 2.1 mm i.d., film thickness 4 microm). The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 5.0-150 ng ml(-1) (r(2) > 0.9952). The limit of quantification was 5 ng ml(-1). This HPLC/MS/MS procedure was used to assess the bioequivalence of two bromazepam 6 mg tablet formulations (bromazepam from Medley SA Indústria Farmacêutica as the test formulation and Lexotan from Produtos Roche Químico e Farmacêutico SA as the reference formulation). A single 6 mg dose of each formulation was administered to 24 healthy volunteers (12 males and 12 females). The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. Since the 90% CI for C(max), AUC(last), AUC(0-240 h) (linear) and AUC((0- infinity )) ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the bromazepam formulation from Medley is bioequivalent to the Lexotan formulation for both the rate and the extent of absorption.  相似文献   

17.
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a plant growth regulator, highly polar, which is typically present in aqueous solution in anionic form due to its acid character. Both its extraction and pre-concentration from water samples and its chromatographic retention are difficult. Several approaches for sample pretreatment have been tested including direct injection into the chromatographic system, on-line solid phase extraction (SPE) and off-line SPE, with the best results being obtained after off-line SPE, using Oasis MAX cartridges (mixed-mode strong anion-exchange). After testing several ion-pairing reagents, tetrabuthylammonium acetate (TBA) was selected. This was added to the samples before LC/MS/MS analysis to facilitate ethephon chromatographic retention. The acquisition of several specific MS/MS transitions together with the evaluation of their relative intensity ratios allowed the reliable confirmation of the analyte in samples. The optimised approach was tested in low-salinity water spiked at 0.1?µg?L?1 level with satisfactory recovery, and a limit of detection of 0.02?µg?L?1. To this purpose, the water sample was partially de-ionised in an initial stage, in order to remove major ions that would have interfered in analyses. The application of this methodology to more saline/complex water samples, as surface or wastewater, was problematic and a thorough optimisation of the de-ionisation conditions would be required.  相似文献   

18.
A robust and sensitive method was developed for the enantiomeric analysis of six chiral pesticides (including metalaxyl, epoxiconazole, myclobutanil, hexaconazole, napropamide, and isocarbophos) in aquatic environmental samples. The optimized chromatographic conditions for the quantification of all the 12 enantiomers were performed with Chiralcel OD‐RH column using mobile phase consisting of 0.1% aqueous formic acid and acetonitrile operated under reversed‐phase conditions and then analyzed using liquid chromatography with tandem mass spectrometry. Twelve enantiomers were detected in multiple reaction monitoring mode. Solid‐phase extraction and dispersive liquid–liquid microextraction were employed in this study. Response surface methodology was applied to assist in the dispersive liquid–liquid microextraction optimization. Under the optimum conditions, recoveries of pesticides enantiomers varied from 83.0 to 103.2% at two spiked levels with relative standard deviation less than 11.5%. The concentration factors were up to 1000 times. Method detection and quantification limits varied from 0.11 to 0.48 ng/L and from 0.46 to 1.49 ng/L, respectively. Finally, this method was used to determination of the enantiomers composition of the six pesticides in environmental aqueous matrices, which will help better understand the behavior of individual enantiomer and make accurate risk assessment to ecosystems.  相似文献   

19.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

20.
A method for detection of semicarbazide (SEM) in baby food was validated. SEM was extracted with hydrochloric acid and derivatised with 2-nitrobenzaldehyde, using [15N2,13C] semicarbazide as internal standard. The extract was neutralised, purified on a solid phase extraction cartridge and SEM was determined by reversed phase LC-MS-MS. Linearity was demonstrated in the ranges from 0.1 ng ml(-1) to 1 ng ml(-1) and from 2 ng ml(-1) to 80 ng ml(-1). Matrix effects were non significant for meat-based and significant for apple and rice-based baby foods, in both ranges. Mean recoveries ranged from 87.8% to 107.2% with relative standard deviation from 0.2% to 9.1%, considering both ranges. Limits of detection and quantification were 0.1 microg kg(-1) and 0.25 microg kg(-1), respectively. The results of the validation process demonstrated the method suitability for use in food control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号