共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of separation science》2017,40(9):1966-1973
We utilized ultra‐high performance liquid chromatography with tandem mass spectrometry and dispersive solid‐phase extraction to develop a new method for the detection of nine analytes (scopolamine, cephaeline, strychnine, hyoscyamine, brucine, hydrastine, ajmalicine, colchicine, and oleandrin) in herbal cosmetics. Acetonitrile/water and 2‐propylaminoethylamine were used to disperse and purify during the dispersive solid‐phase extraction step. The analytes were separated by a Waters UPLC HSS T3 column and detected through electrospray ionization source in the positive mode with multi‐reaction monitoring conditions. Under the optimal conditions, the calibration curves were linear in the range of 0.2–100.0 μg/L with the correlation coefficients higher than 0.995. The method limit of quantitation (S/N = 10) were 5.0 μg/kg for oleandrin and 1.0 μg/kg for the other eight alkaloids. The mean recoveries at three spiked concentration levels of 1.0–10.0 μg/kg were in the range of 86.9–116.5% with the intra‐day relative standard deviations (n = 6) ranging from 2.4 to 8.8%, and inter‐day relative standard deviations ranging from 2.7 to 5.7%. This method is accurate, simple and rapid, and has been applied to the quality supervision of herbal cosmetics in Guangzhou. 相似文献
2.
《Journal of separation science》2018,41(11):2354-2359
A gas chromatography with mass spectrometry method was developed for the simultaneous determination of ten kinds of glycol ethers and their acetates in cosmetics. The samples were extracted with methanol/ethyl acetate (80:20, v/v), further treated with vortex and ultrasound, and analyzed by gas chromatography with mass spectrometry. The concentration of each analyte was calibrated by the external standard method. Under the optimal conditions, the analytes showed linear relationship in the range of 0.05–25 mg/L with determination coefficients larger than 0.9987. The limits of detection and quantification were in the range of 0.09–0.59 and 0.31–1.95 mg/kg, respectively. The average recoveries of three spiked levels were 80.2–105.4% with intra‐ and interday precisions of 1.1–6.3 and 1.9–6.5%, respectively. Method validation from different labs confirmed the satisfactory recoveries and precisions. This method shows advantages of simple, high sensitivity, and high recovery, which can be applied to the detection of glycol ethers and acetates in cosmetics. 相似文献
3.
Junxue Wu Shenwei Zhi Chunhong Jia Xinghai Li Xiaodan Zhu Ercheng Zhao 《Journal of separation science》2019,42(24):3688-3696
In this study, a simple and accurate sample preparation method based on dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction has been developed for the determination of seven novel succinate dehydrogenase inhibitor fungicides (isopyrazam, fluopyram, pydiflumetofen, boscalid, penthiopyrad, fluxapyroxad, and thifluzamide) in watermelon. The watermelon samples were extracted with acetonitrile, cleaned up by dispersive solid‐phase extraction procedure using primary secondary amine, extracted and concentrated by the dispersive liquid‐liquid microextraction procedure with 1,1,2,2‐tetrachloroethane, and then analyzed by ultra high performance liquid chromatography with tandem mass spectrometry. The main experimental factors affecting the performance of dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction procedure on extraction efficiency were investigated. The proposed method had a good linearity in the range of 0.1–100 µg/kg with correlation coefficients (r) of 0.9979–0.9999. The limit of quantification of seven fungicides was 0.1 µg/kg in the method. The fortified recoveries of seven succinate dehydrogenase inhibitor fungicides at three levels ranged from 72.0 to 111.6% with relative standard deviations of 3.4–14.1% (n = 5). The proposed method was successfully used for the rapid determination of seven succinate dehydrogenase inhibitor fungicides in watermelon. 相似文献
4.
Yi‐Qun Wan Xue‐Jin Mao Ai‐Ping Yan Ming‐Yue Shen Yu‐Mei Wu 《Biomedical chromatography : BMC》2010,24(9):961-968
A reliable, rapid and nontoxic analytical method was proposed for the simultaneous determination of 16 organophosphorus pesticides in Chinese herbal medicines. The pesticides were extracted by ethanol and the experimental variables, such as temperature, extraction time and volume of ethanol, were optimized through orthogonal array experimental design. Cleanup of extracts was performed with dispersive‐solid phase extraction using primary secondary amine as the sorbent. The determination of pesticides in the final extracts was carried out by gas chromatography–flame photometric detection. Under optimized conditions the obtained recoveries, except for isocarbophos, were in the range 73.8–123%, with relative standard deviations equal to or lower than 15.2% and limits of detection ranging from 0.001 to 0.009 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
5.
Jianxun Li Jihao Shan Zhiqiang Kong Chunlin Fan Zijuan Zhang Bei Fan 《Journal of separation science》2020,43(2):486-495
In this study, an effective speed‐regulated directly suspended droplet microextraction method was developed to condense pesticide residues from teas through dispersive solid‐phase extraction prior to analysis by gas chromatography with tandem mass spectrometry. The extractant was intentionally dispersed into the sample solution in the form of globules through high‐speed agitation. This procedure increases the contact area between the binary phases and shortens the distribution equilibrium time. The fine globules reassembled by decelerating stirring speed, the extractant could be taken out for gas chromatography with tandem mass spectrometry. Recovery studies were performed under optimized extraction conditions by using matrix blanks fortified with pesticides at three concentrations (10, 50, and 100 µg/kg). Over 87% of the recoveries for the analytes in four tea matrices were acceptable given their recovery ranges of 70–120% and relative standard deviations of ≤20%. The limits of quantification of most pesticides were lower than 10 µg/kg and thus satisfied the requirements for maximum residue levels prescribed by the European Community. A total of 38 tea samples from local markets were analyzed by using the proposed method. Results showed that chlorpyrifos was the most frequently detected pesticide in teas. The method is a potential choice for the routine monitoring of pesticide residues in complex matrices. 相似文献
6.
Jingyun Liang Yanjie Dong Xuexia Yuan Lixia Fan Shancang Zhao Lei Wang 《Journal of separation science》2019,42(13):2191-2201
A dispersive solid‐phase extraction coupled with ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of T‐2 toxin, penicillic acid, fumonisins B1, B2, and B3, aflatoxins B1, B2, G1, and G2, ochratoxin A, deoxynivalenol, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, and zearalenone in chestnut samples. The method was used to analyze 136 samples obtained from Shandong province in China. The mycotoxins were extracted using a dispersive solid‐phase extraction method and cleaned using an improved quick, easy, cheap, effective, rugged, and safe approach. The mycotoxins were then detected using a triple‐quadrupole mass spectrometer. The limits of detection and quantification ranged from 0.02 to 1 and 0.1 to 2 μg/kg, respectively. The recovery rates ranged from 74.2 to 109.5%, with relative standard deviations below 15%. A total of 71 samples were contaminated with seven mycotoxins at concentrations ranging from 1.2 to 105.5 μg/kg, with a number of samples exceeding the maximum limits set in the European regulations for mycotoxins in unprocessed chestnuts. 相似文献
7.
Shahram Seidi Fahimeh Mohammadi Mohammad Tajik Mahroo Baharfar Abdorreza Mohammadi Tohid Otoufat 《Journal of separation science》2020,43(14):2897-2904
Magnetic dispersive solid‐phase extraction followed by dispersive liquid?liquid microextraction coupled with gas chromatography/mass spectrometry was applied for the quantitative analysis of phenazopyridine in urinary samples. Magnetic dispersive solid‐phase extraction was carried out using magnetic graphene oxide nanoparticles modified by poly(thiophene‐pyrrole) copolymer. The eluting solvent of this step was used as the disperser solvent for the dispersive liquid?liquid microextraction procedure. To reach the maximum efficiency of the method, effective parameters including sorbent amount, adsorption time, type and volume of disperser and extraction solvents, pH of the sample solution, and ionic strength as well as desorption time, and approach were optimized, separately. Characterization of the synthesized sorbent was studied by utilizing infrared spectroscopy, scanning electron microscopy, and energy‐dispersive X‐ray analysis. Calibration curve was linear in the range of 0.5?250 ng/mL (R2 = 0.9988) with limits of detection and quantification of 0.1 and 0.5 ng/mL, respectively. Intra‐ and interday precisions (RSD%, n = 3) of the method were in the range of 4.6?5.4% and 4.0?5.5%, respectively, at three different concentration levels. Under the optimal condition, this method was successfully applied for the determination of phenazopyridine in human urine samples. The relative recoveries were obtained in the range of 85.0?89.0%. 相似文献
8.
Enrichment and determination of polybrominated diphenyl ethers in environmental water samples by magnetic solid‐phase extraction with core–shell magnetic carbon microspheres before gas chromatography with mass spectrometry 下载免费PDF全文
Jia‐Bin Zhou Xiao‐Kun She Han‐Zhu Xing Ru‐Song Zhao 《Journal of separation science》2016,39(10):1955-1962
Core–shell magnetic carbon microspheres were synthesized by a simple hydrothermal method and used as a novel magnetic solid‐phase extraction adsorbent for the sensitive determination of polybrominated diphenyl ethers in environmental water samples. Gas chromatography with negative chemical ionization mass spectrometry was adopted for the detection. Box–Behnken design was used to investigate and optimize important magnetic solid‐phase extraction parameters through response surface methodology. Under the optimal conditions, low limits of detection (0.07–0.17 ng·L?1), a wide linear range (1–1000 ng·L?1), and good repeatability (0.80–4.58%) were achieved. The developed method was validated with several real water samples, and satisfactory results were obtained in the range of 72.8–97.9%. These results indicated that core–shell magnetic carbon microspheres have great potential as an adsorbent for the magnetic solid‐phase extraction of polybrominated diphenyl ethers at trace levels from environmental water samples. 相似文献
9.
Determination of nine volatile N‐nitrosamines in tobacco and smokeless tobacco products by dispersive solid‐phase extraction with gas chromatography and tandem mass spectrometry 下载免费PDF全文
Fang Lv Junwei Guo Fei Yu Tingting Zhang Shimin Zhang Huapeng Cui Xianjun Liu Li Chen Leiyu Liu Shaofeng Liu Fuwei Xie 《Journal of separation science》2016,39(11):2123-2128
A method was developed for the determination of nine volatile N‐nitrosamines in tobacco and smokeless tobacco products. The targets are N‐nitrosodimethylamine, N‐nitrosopyrrolidine, N‐nitrosopiperidine, N‐nitrosomorpholine, N‐nitrosoethylmethylamine, N‐nitrosodiethylamine, N‐nitrosodipropylamine, N‐nitrosobuylmethylmine, and N‐nitrosodibutylamine. The samples were treated by dispersive solid‐phase extraction using 1 g of primary secondary amine and 0.5 g of carbon and then analyzed by gas chromatography with tandem mass spectrometry with an electron impact ion source. The recoveries for the targets ranged from 84 to 118%, with <16% relative standard deviations at three spiking levels of 0.5, 1.25, and 2.5 ng/g. The limits of detection ranged from 0.03 to 0.15 ng/g. With the use of the proposed method, we detected the presence of six nitrosamines in the range of 0.4–30.7 ng/g. The study demonstrated that the method could be used as a rapid, convenient, and high‐throughput method for N‐nitrosamines analysis in tobacco matrix. 相似文献
10.
《Journal of separation science》2018,41(12):2565-2575
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection. 相似文献
11.
Zigang Tang Qing Han Li Xie Lanling Chu Yu Wang Ying Sun Xuejun Kang 《Journal of separation science》2019,42(4):851-861
A novel polystyrene/pyridine composite nanofiber was synthesized and utilized as the sorbent material for the solid‐phase extraction of bisphenol A and five common phthalate esters in milk. The method of extraction integrated extraction and preconcentration of target analytes into a single step. Bisphenol A and five common phthalate esters were selected as target compounds for the development and evaluation of the method. The effects of operating parameters for nanofiber‐based solid‐phase extraction, such as selection and amount of sorbent, the volume fraction of perchlorate (precipitate protein), desorption solvent, volume of desorption solvent, and effect of salt addition were optimized. Under optimal conditions, higher extraction recoveries (89.6–118.0%) of the six compounds in milk spiked at three levels were obtained, and the satisfied relative standard deviation were ranged from 0.6 to 10.9%. The detection limits and quantification limits of the method ranged from 0.01 to 0.06 μg/L and 0.05 to 0.53 μg/L, respectively. Matrix effects were also verified and well controlled in the range of 91.3–109.3%. The new method gave better performance metrics than Chinese standard method and other published methods. Thus, the proposed method may be applied to the analysis of the phthalate esters and bisphenol A in complex matrixes. 相似文献
12.
《Journal of separation science》2017,40(16):3279-3288
A simple, rapid, and novel method has been developed and validated for determination of seven indicator polychlorinated biphenyls in water samples by gas chromatography with electron capture detection. 1 L of water samples containing 30 g of anhydrous sodium sulfate was first liquid–liquid extracted with an automated Jipad‐6XB vertical oscillator using n‐hexane/dichloromethane (1:1, v/v). The concentrated extract was cleaned up by dispersive solid‐phase extraction with 100 mg of primary secondary amine as sorbent material. The linearity of this method ranged from 1.25 to 100 μg/L, with regression coefficients ranging between 0.9994 and 0.9999. The limits of detection were in the ng/L level, ranging between 0.2 and 0.3 ng/L. The recoveries of seven spiked polychlorinated biphenyls with external calibration method at different concentration levels in tap water, lake water, and sea water were in the ranges of 85–112, 76–116, and 72–108%, respectively, and with relative standard deviations of 3.3–4.5, 3.4–5.6, and 3.1–4.8% (n = 5), respectively. The performance of the proposed method was compared with traditional liquid–liquid extraction and solid‐phase extraction clean‐up methods, and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of polychlorinated biphenyls in different water samples. 相似文献
13.
《Journal of separation science》2017,40(5):1142-1149
An efficient sample extraction and clean‐up method was developed for simultaneous determination of five amide herbicides (alachlor, acetochlor, propisochlor, metazachlor, and butachlor) in fish samples. The protocol consisted of ultrasound‐assisted solvent extraction and solid‐phase extraction clean‐up. In detail, aliquots of homogenized fish flesh were thoroughly mixed with 20 mL of n‐hexane and then extracted with ultrasonication for 40 min. Each sample was centrifuged and the supernatant was collected for the subsequent clean‐up. For the sample preparation, the above supernatant was processed with a C18 column with 3 mL of dichloromethane/n‐hexane (1:1, v/v) as the eluant. Then the samples were analyzed by gas chromatography with electron capture detection. The correlation coefficients of the five calibration curves were 0.9976–0.9998 (n = 3). The limits of detection (S/N = 3, n = 11) and limits of quantification (S/N = 10, n = 11) were 0.19–0.42 and 0.63–1.39 μg/kg, respectively. The recoveries of this method were 71.2–92.6% with good precision (<4.7% relative standard deviations, n = 6). The developed method was successfully applied to monitor the five amide herbicides in fish samples collected from different cities. 相似文献
14.
Dapeng Liang Wenjie Liu Rabia Raza Yu Bai Huwei Liu 《Journal of separation science》2019,42(1):330-341
Pesticides, widely applied in agriculture, can produce a variety of transformation products and their continuous use causes deleterious effects to ecosystem. Efficient and sensitive analytical techniques for enrichment and analysis of pesticides samples are highly required. Compared with other extraction methods, solid‐phase micro extraction is a solvent free, cost effective, robust, versatile, and high throughput sample preparation technique, especially for the analysis of pesticides from complicated matrices. Coupling of solid‐phase micro extraction with gas chromatography and mass spectrometry and liquid chromatography–mass spectrometry has been extensively applied in pesticide analysis. On the other hand, in recent years, combination of fast separation using solid‐phase micro extraction and rapid detection using ambient mass spectrometry is providing highly efficient pesticide screening. This article summarizes the applications of solid‐phase micro extraction coupled to mass spectrometry for pesticides analysis. 相似文献
15.
Zhi‐Yong Guo Pan‐Pan Gai Jing Duan Jin‐Xia Zhai Sha‐Sha Zhao Sui Wang Dan‐Yi Wei 《Biomedical chromatography : BMC》2010,24(10):1094-1099
A gas chromatography–mass spectrometry assay was developed and validated for the simultaneous determination of phthalates and adipates in human serum. The phthalates and adipates studied were dimethyl phthalate, diethyl phthalate, dibutyl phthalate, benzylbutyl phthalate, di‐2‐ethylhexyl phthalate, di‐n‐octyl phthalate, diethyl adipate, dibutyl adipate, diisobutyl adipate, bis(2‐butoxyethyl) adipate and di‐2‐ethylhexyl adipate, with diisooctyl phthalate as internal standard. The extraction and cleaning up procedure was carried out with solid‐phase extraction cartridges containing dimethyl butylamine groups, which showed extraction efficiencies over 88% for each analyte and the internal standard. The calibration curves obtained were linear with correlation coefficients greater than 0.98. For all analytes, the assay gave CV% values for intra‐day precision from 4.9 to 13.3% and mean accuracy values from 91.4 to 108.4%, while inter‐day precision was 5.2–13.4% and mean accuracy 91.0–110.2%. The limits of detection for the assay of phthalates and adipates were in the range 0.7–4.5 ng/mL. The method is simple, sensitive and accurate, and allows for simultaneous determination of nanogram levels of phthalates and adipates in human serum. It was successfully applied to an investigation on the level of phthalates and adipates in a non‐occupationally exposed population. 相似文献
16.
《Journal of separation science》2017,40(3):709-716
Two simplified sample preparation procedures for simultaneous extraction and clean‐up of tetrabromobisphenol A, α‐, β‐, and γ‐hexabromocyclododecane and polybrominated diphenyl ethers in human serum were developed and validated. The first procedure was based on solid‐phase extraction. Sample extraction, purification, and lipid removal were carried out directly on an Oasis HLB cartridge. The second procedure was a quick, easy, cheap, effective, rugged, and safe‐based approach using octadecyl‐modified silica particles as a sorbent. After sample extraction and cleanup, tetrabromobisphenol A/hexabromocyclododecane was separated from polybrominated diphenyl ethers by using a Si‐based cartridge. Tetrabromobisphenol A and hexabromocyclododecane were then detected by high‐performance liquid chromatography coupled to tandem mass spectrometry, while polybrominated diphenyl ethers were detected by gas chromatography coupled to tandem mass spectrometry. The results of the spike recovery test using fetal bovine serum showed that the average recoveries of the analytes ranged from 87.3 to 115.3% with relative standard deviations equal to or lower than 13.4 %. Limits of detection of the analytes were in the range of 0.4–19 pg/mL except for decabromodiphenyl ether. The developed method was successfully applied to routine analysis of human serum samples from occupational workers and the general population. Extremely high serum polybrominated diphenyl ethers levels up to 3.32 × 104 ng/g lipid weight were found in occupational workers. 相似文献
17.
《Journal of separation science》2017,40(21):4256-4263
Polypyrrole‐magnetite dispersive micro‐solid‐phase extraction method combined with ultraviolet‐visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole‐magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro‐solid‐phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole‐magnetite dispersive micro‐solid phase‐extraction conditions were sample pH 8, 60 mg polypyrrole‐magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole‐magnetite dispersive micro‐solid‐phase extraction with ultraviolet‐visible method showed good linearity in the range of 0.05–7 mg/L (R 2 > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4–111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels. 相似文献
18.
《Journal of separation science》2017,40(16):3257-3266
A novel and reliable method for determination of five triazole fungicide residues (triadimenol, tebuconazole, diniconazole, flutriafol, and hexaconazol) in traditional Chinese medicine samples was developed using dispersive solid‐phase extraction combined with ultrasound‐assisted dispersive liquid–liquid microextraction before ultra‐high performance liquid chromatography with tandem mass spectrometry. The clean up of the extract was conducted using dispersive solid‐phase extraction by directly adding sorbents into the extraction solution, followed by shaking and centrifugation. After that, a mixture of 400 μL trichloromethane (extraction solvent) and 0.5 mL of the above supernatant was injected rapidly into water for the dispersive liquid–liquid microextraction procedure. The factors affecting the extraction efficiency were optimized. Under the optimum conditions, the calibration curves showed good linearity in the range of 2.0–400 (tebuconazole, diniconazole, and hexaconazole) and 4.0–800 ng/g (triadimenol and flutriafol) with the regression coefficients higher than 0.9958. The limit of detection and limit of quantification for the present method were 0.5–1.1 and 1.8–4.0 ng/g, respectively. The recoveries of the target analytes ranged from 80.2 to 103.2%. The proposed method has been successfully applied to the analysis of five triazole fungicides in traditional Chinese medicine samples, and satisfactory results were obtained. 相似文献
19.
Rapid determination of the volatile components in tobacco by ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction with gas chromatography‐mass spectrometry 下载免费PDF全文
Yanqin Yang Guohai Chu Guojun Zhou Jian Jiang Kailong Yuan Yuanjiang Pan Zhiyu Song Qian Xia Xinbo Lu Weiqiang Xiao 《Journal of separation science》2016,39(6):1173-1181
An ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid‐phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method was compared with the microwave‐assisted extraction coupled to headspace solid‐phase microextraction and headspace solid‐phase microextraction methods. More types of volatile components were obtained by using the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction technique was a simple, time‐saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. 相似文献
20.
《Journal of separation science》2017,40(21):4234-4245
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. 相似文献