首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 350 毫秒
1.
A primary filter is often used for low‐concentration analysis by energy‐dispersive X‐ray fluorescence spectrometer. We determined the material and thickness of the primary filter and calculated the theoretical intensities of the fluorescent X‐rays and scattered X‐rays using lead in brass, for which the concentration is known. The filter materials were zirconium, nickel, titanium, aluminum, and molybdenum with a thickness between 20 and 125 µm. For verification, we calculated the lower limits of detection using theoretical intensities for several filters and compared them with values calculated using the measured intensities. For example, both values were similar for a 125 µm zirconium filter: 128.0 ppm using theoretical intensities and 147.7 ppm using measured intensities. The theoretical intensity values are obtained by measurements and calculations, but require no primary filters for the measurements. This method is extremely effective for selecting the optimal filter for multiple samples and elements. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
Calculations are presented of the electronic structure and X‐ray spectra of materials with correlated d‐ and f‐electron states based on the Hubbard model, a real‐space multiple‐scattering formalism and a rotationally invariant local density approximation. Values of the Hubbard parameter are calculated ab initio using the constrained random‐phase approximation. The combination of the real‐space Green's function with Hubbard model corrections provides an efficient approach to describe localized correlated electron states in these systems, and their effect on core‐level X‐ray spectra. Results are presented for the projected density of states and X‐ray absorption spectra for transition metal‐ and lanthanide‐oxides. Results are found to be in good agreement with experiment.  相似文献   

3.
Relative line intensities of L1, L2 and L3 sub‐shell X‐rays were measured for Er, Tm, Yb, Hf, Ta, W, Pt and Au. The L‐shell X‐ray spectra were recorded by exciting pure element samples (eight cases) and oxide samples (two cases) with approximately 17‐keV exciting radiation from a filtered X‐ray tube source, and measuring the fluorescence spectra with a silicon drift detector. The spectra were carefully fitted to determine line energies and intensities, accounting for Lorentzian line broadening, incomplete charge collection and escape effects. A Monte Carlo approach was used to calculate attenuation and detector efficiency corrections. We report up to 15 line intensity ratios for each element and compare these to Scofield's theoretical predictions and Elam's extrapolated experimental database. Our measured relative line intensities agree best with Elam's data, but overall we find significant discrepancies with previously reported results. For the element Ta, we also find significant errors in the accepted L‐shell line energies in the widely used National Institute of Standard and Technology (NIST) database. Our results highlight the need for an experimental and theoretical re‐evaluation of L‐shell intensity databases to support high‐accuracy X‐ray analysis methods such as X‐ray fluorescence and particle‐induced X‐ray emission. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
A novel X‐ray Bragg optics is proposed for variable‐magnification of an X‐ray beam. This X‐ray Bragg optics is composed of two magnifiers in a crossed arrangement, and the magnification factor, M, is controlled through the azimuth angle of each magnifier. The basic properties of the X‐ray optics such as the magnification factor, image transformation matrix and intrinsic acceptance angle are described based on the dynamical theory of X‐ray diffraction. The feasibility of the variable‐magnification X‐ray Bragg optics was verified at the vertical‐wiggler beamline BL‐14B of the Photon Factory. For X‐ray Bragg magnifiers, Si(220) crystals with an asymmetric angle of 14° were used. The magnification factor was calculated to be tunable between 0.1 and 10.0 at a wavelength of 0.112 nm. At various magnification factors (M≥ 1.0), X‐ray images of a nylon mesh were observed with an air‐cooled X‐ray CCD camera. Image deformation caused by the optics could be corrected by using a 2 × 2 transformation matrix and bilinear interpolation method. Not only absorption‐contrast but also edge‐contrast due to Fresnel diffraction was observed in the magnified images.  相似文献   

5.
A mathematical model for the two‐layer composite Si‐Ge energy dispersive X‐ray detector is proposed, based on analyses of radiation and electron transport in the detector, and a mathematical model of an energy dispersive X‐ray fluorescent spectrometer with the detector is considered. The Monte Carlo method is applied to calculate probabilities of photon detection in different parts of the detector's response function. The composite detector with the time anti‐coincidence scheme is proposed; its first layer is Si detector, and the second layer is Ge detector. It is shown that this composite detector has some advantages, such as reduced Ge photo escape peaks intensities and efficiency of detection of high energy photons similar to efficiency of Ge detector. Applying the X‐ray detector for the energy dispersive X‐ray fluorescent spectrometer provides for a lower background level. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
The performance of a diamond X‐ray beam position monitor is reported. This detector consists of an ionization solid‐state chamber based on a thin single‐crystal chemical‐vapour‐deposition diamond with position‐sensitive resistive electrodes in a duo‐lateral configuration. The detector's linearity, homogeneity and responsivity were studied on beamlines at Synchrotron SOLEIL with various beam sizes, intensities and energies. These measurements demonstrate the large and homogeneous (absorption variation of less than 0.7% over 500 µm × 500 µm) active area of the detector, with linear responses independent of the X‐ray beam spatial distribution. Due to the excellent charge collection efficiency (approaching 100%) and intensity sensitivity (0.05%), the detector allows monitoring of the incident beam flux precisely. In addition, the in‐beam position resolution was compared with a theoretical analysis providing an estimation of the detector's beam position resolution capability depending on the experimental conditions (X‐ray flux, energy and readout acquisition time).  相似文献   

7.
X‐ray Raman scattering (XRS) provides a bulk‐sensitive method of measuring the extended X‐ray absorption fine structure (EXAFS) of soft X‐ray absorption edges. Accurate measurements and data analysis procedures for the determination of XRS‐EXAFS of polycrystalline diamond are described. The contributions of various angular‐momentum components beyond the dipole limit to the atomic background and the EXAFS oscillations are incorporated using self‐consistent real‐space multiple‐scattering calculations. The properly extracted XRS‐EXAFS oscillations are in good agreement with calculations and earlier soft X‐ray EXAFS results. It is shown, however, that under certain conditions multiple‐scattering contributions to XRS‐EXAFS deviate from those in standard EXAFS, leading to noticeable changes in the real‐space signal at higher momentum transfers owing to non‐dipole contributions. These results pave the way for the accurate application of XRS‐EXAFS to previously inaccessible light‐element systems.  相似文献   

8.
Lα and Lβ X‐ray fluorescence spectra of a lead metallic sheet were measured using an energy dispersive X‐ray spectrometer by changing the X‐ray tube voltage and the material of the primary filter. The Lα to Lβ intensity ratio changed from Lα: Lβ = 3: 1 at 15 kV to Lα: Lβ = 1: 1 at 50 kV depending on the X‐ray tube voltage and the filter. The scattered X‐ray spectra of an acrylic slab instead of the sample in the sample holder were measured by changing the applied voltage and the material of the primary filter. The calculated values of the Pb Lα/Lβ intensity ratio of the metallic sheet using the Shiraiwa–Fujino formula by inserting the scattered X‐ray spectra of an acrylic plate as incident X‐ray spectra and the fundamental parameters taken from the Elam database were in good agreement with the experimental ones. We conclude that we can obtain an incident X‐ray spectrum approximately by measuring the scattered X‐ray spectrum without measuring the direct incident beam. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
The energy spectrum analysis of X‐ray intensities with semiconductor detectors is often difficult because their energy resolution is usually not good enough to separate the different X‐ray lines. Metallic magnetic calorimeters (MMCs) can be an alternative; they can offer both high energy resolution and high intrinsic detection efficiency from 0 to 100 keV. MMCs are thermal detectors; that is to say, the energy of each absorbed photon is measured as a temperature elevation. At very low temperature, typically few tens of mK, a very large pulse height‐to‐noise ratio can be obtained that is an essential condition for high energy resolution. We are involved in the development of MMCs for metrology applications such as the determination of hard X‐ray emission intensities. For that purpose, we conceived an MMC with an energy resolution of 57 eV around 30 keV. The absorber is made of gold providing high intrinsic detection efficiency even for a small volume, greater than 90% below 60 keV. We will describe the physical principle and the practical realisation of this detector and discuss its performances by analysing the energy spectrum obtained from a 133Ba source. Preliminary outcomes of relative emission intensities of the K X‐ray of cesium are presented and compared with other experimental data and theoretical calculations. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
This work concerns determination of the manganese valence state and speciation by wavelength‐dispersive X‐ray fluorescence analysis. The authors investigated the effect of the manganese valence state and speciation on the intensity of some К‐series lines of the X‐ray emission spectrum for the samples of manganese compounds. The intensities of MnKβ5 line and MnKβ′ satellite are least influenced by speciation, and they may be used for evaluating the manganese valence state for the samples containing low iron. The intensities of MnKβ″ and MnKβx satellites may be employed for assessing the manganese speciation. The results of X‐ray fluorescence determination of the manganese valence state and speciation in the manganese ores of the South Ural deposits agree with the X‐ray diffraction data. The X‐ray fluorescence method is definitely advantageous, because it does not require a complicated process of sample preparation and allows to receive fast information on the manganese valence state and speciation with the purpose to assess the quality of manganese ores. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
《X射线光谱测定》2003,32(2):106-112
With the nowadays widespreaded use of x‐ray optics in x‐ray fluorescence analysis, large convergence or divergence angles can occur. This experimental situation violates a basic assumption of the usual fundamental parameter quantification procedure. In order to take beam divergences in micro x‐ray fluorescence analysis into account, a way of calculating fluorescence intensities numerically by Monte Carlo integration is described. For three examples of typical micro‐XRF set‐ups the fluorescence intensities and their deviation from the parallel beam geometry are calculated. Furthermore, we propose a new approach with ‘equivalent angles’ which correct for the beam divergences in fundamental parameter methods. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
Capillary optics are used for X‐ray fluorescence micro‐analysis using the Cu Kα line provided by a rotating anode. The excitation beam is focused using a polycapillary lens on a Co–Ti sample. Cylindrical glass capillaries of various diameters are fitted to the X‐ray detector (Energy Dispersive X‐Ray (EDX) analyzer) and displaced along the irradiated zone of the sample. The fluorescence is studied as a function of capillary position. Good agreement is found between experimental and calculated lateral widths of the fluorescence collection, taken into account the cylindrical capillary critical angles relevant in the experiment. The influence of the cylindrical capillary diameter on the signal level detected is studied to estimate the possibility of lateral resolution increase of X‐ray fluorescence technique both in‐lab and in synchrotron environment. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
K α X‐ray satellite spectra of Co, Ni, Cu, Zn, and Ga generated by photon excitation are analyzed using a wavelength dispersion spectrometer. Spectra of Ni, Cu, Zn, and Ga are studied for the first time using a LiF420 crystal. Spectrum of Co was studied with LiF200 crystal in second order. KαL1 X‐ray satellite energies and relative intensities are measured. The energy shifts relative to diagram line are computed and are compared with theoretical and semi‐empirical values. Dependence of energy shifts and relative intensities on Z and mode of excitation is analyzed.  相似文献   

14.
This paper describes the X‐ray fluorescence technique for estimation of the ratio between sulfide and total sulfur in sulfide ores using the influence of sulfur chemical state on positions and intensities of lines (SKα1,2, SKβ1,3) and satellites (SKβ′, SKα3,4) of the sulfur X‐ray emission spectra measured by the wavelength‐dispersive X‐ray fluorescence spectrometer. The samples to be analyzed were prepared as pressed powder pellets on boric acid substrate. The SKα1,2 line chemical shift is the most appropriate parameter for sulfur chemical state estimation because spectral lines in this field are intensive and are almost not affected by spectral overlap of lead spectrum lines. The ratios of line intensities SKβ′/SKβ1,3, SKα3,4/SKα1,2 and SKβ1,3/SKα1,2 were also used as analytical parameters. Forty‐one samples of sulfide ores collected in the Russian Far East and Southern Ural deposits have been analyzed. The results of estimation of sulfur chemical state by gravimetric and proposed X‐ray fluorescence techniques agree fairly well. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
We present in this paper, M‐shell ionization cross sections and M X‐ray production cross sections calculated within the Energy loss, Coulomb deflection, Perturbed Stationary State and Relativistic effects (ECPSSR) theory for elements with 72 ≤ Z ≤ 90 for protons with 0.1–4.0 MeV energy. Our results are compared to the plane wave Born approximation (PWBA) predictions, the relativistic plane‐wave Born approximation including corrections for binding and Coulomb deflection effect (RPWBA‐BC) results and the ECPSSR calculations from earlier works. On the other hand, semiempirical and empirical M X‐ray production cross sections are deduced from the polynomial fitting of the available experimental data collected from different sources. A comparison is made between the different sets of results. The differences between the above calculations and the experimental results are pointed out and discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
The ability to probe morphology and phase distribution in complex systems at multiple length scales unravels the interplay of nano‐ and micrometer‐scale factors at the origin of macroscopic behavior. While different electron‐ and X‐ray‐based imaging techniques can be combined with spectroscopy at high resolutions, owing to experimental time limitations the resulting fields of view are too small to be representative of a composite sample. Here a new X‐ray imaging set‐up is proposed, combining full‐field transmission X‐ray microscopy (TXM) with X‐ray absorption near‐edge structure (XANES) spectroscopy to follow two‐dimensional and three‐dimensional morphological and chemical changes in large volumes at high resolution (tens of nanometers). TXM XANES imaging offers chemical speciation at the nanoscale in thick samples (>20 µm) with minimal preparation requirements. Further, its high throughput allows the analysis of large areas (up to millimeters) in minutes to a few hours. Proof of concept is provided using battery electrodes, although its versatility will lead to impact in a number of diverse research fields.  相似文献   

17.
A new prism‐array lens for high‐energy X‐ray focusing has been constructed using an array of different prisms obtained from different parabolic structures by removal of passive parts of material leading to a multiple of 2π phase variation. Under the thin‐lens approximation the phase changes caused by this lens for a plane wave are exactly the same as those caused by a parabolic lens without any additional corrections when they have the same focal length, which will provide good focusing; at the same time, the total transmission and effective aperture of this lens are both larger than those of a compound kinoform lens with the same focal length, geometrical aperture and feature size. This geometry can have a large aperture that is not limited by the feature size of the lens. Prototype nickel lenses with an aperture of 1.77 mm and focal length of 3 m were fabricated by LIGA technology, and were tested using CCD camera and knife‐edge scan method at the X‐ray Imaging and Biomedical Application Beamline BL13W1 at Shanghai Synchrotron Radiation Facility, and provided a focal width of 7.7 µm and a photon flux gain of 14 at an X‐ray energy of 50 keV.  相似文献   

18.
A confocal full‐field X‐ray microscope has been developed for use as a novel three‐dimensional X‐ray imaging method. The system consists of an X‐ray illuminating `sheet‐beam' whose beam shape is micrified only in one dimension, and an X‐ray full‐field microscope whose optical axis is normal to the illuminating sheet beam. An arbitral cross‐sectional region of the object is irradiated by the sheet‐beam, and secondary X‐ray emission such as fluorescent X‐rays from this region is imaged simultaneously using the full‐field microscope. This system enables a virtual sliced image of a specimen to be obtained as a two‐dimensional magnified image, and three‐dimensional observation is available only by a linear translation of the object along the optical axis of the full‐field microscope. A feasibility test has been carried out at beamline 37XU of SPring‐8. Observation of the three‐dimensional distribution of metallic inclusions in an artificial diamond was performed.  相似文献   

19.
The X‐ray Powder Diffraction (XPD) beamline at the National Synchrotron Light Source II is a multi‐purpose high‐energy X‐ray diffraction beamline with high throughput and high resolution. The beamline uses a sagittally bent double‐Laue crystal monochromator to provide X‐rays over a large energy range (30–70 keV). In this paper the optical design and the calculated performance of the XPD beamline are presented. The damping wiggler source is simulated by the SRW code and a filter system is designed to optimize the photon flux as well as to reduce the heat load on the first optics. The final beamline performance under two operation modes is simulated using the SHADOW program. For the first time a multi‐lamellar model is introduced and implemented in the ray tracing of the bent Laue crystal monochromator. The optimization and the optical properties of the vertical focusing mirror are also discussed. Finally, the instrumental resolution function of the XPD beamline is described in an analytical method.  相似文献   

20.
An X‐ray magnetic circular dichroism experiment under multiple extreme conditions, 2 ≤T≤ 300 K, H≤ 10 T and P≤ 50 GPa, has been achieved at SPring‐8 BL39XU. A combination of the high‐brilliant X‐ray beam and a helicity‐controlled technique enabled the dichroic signal to be recorded with high accuracy. The performance is shown by the outcome of pressure‐induced ferromagnetism in Mn3GaC and the pressure‐suppressed Co moment in ErCo2. Two technical developments, a tiny diamond anvil cell inserted into a superconducting magnet and in situ pressure calibration using 90° Bragg diffraction from a NaCl marker, are also presented. X‐ray magnetic spectroscopy under multiple extreme conditions is now opening a new approach to materials science.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号