首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
The use of two methods in tandem, single-sided membrane introduction mass spectrometry (SS-MIMS) and fiber introduction mass spectrometry (FIMS), is presented as a technique for field analysis. The combined SS-MIMS-FIMS technique was employed in both a modified commercial mass spectrometer and a miniature mass spectrometer for the selective preconcentration of the explosive simulant o-nitrotoluene (ONT) and the chemical warfare agent simulant, methyl salicylate (MeS), in air. A home-built FIMS inlet was fabricated to allow introduction of the solid-phase microextraction (SPME) fiber into the mass spectrometer chamber and subsequent desorption of the trapped compounds using resistive heating. The SS-MIMS preconcentration system was also home-built from commercial vacuum parts. Optimization experiments were done separately for each preconcentration system to achieve the best extraction conditions prior to use of the two techniques in combination. Improved limits of detection, in the low ppb range, were observed for the combination compared to FIMS alone, using several SS-MIMS preconcentration cycles. The SS-MIMS-FIMS response for both instruments was found to be linear over the range 50 to 800 ppb. Other parameters studied were absorption time profiles, effects of sample flow rate, desorption temperature, fiber background, memory effects, and membrane fatigue. This simple, sensitive, accurate, robust, selective, and rapid sample preconcentration and introduction technique shows promise for field analysis of low vapor pressure compounds, where analyte concentrations will be extremely low and the compounds are difficult to extract from a matrix like air.  相似文献   

2.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

3.
Pentachlorophenol (PCP) was used as a model compound to explore the potential of desorption chemical ionization (DCI) in the determination of polychlorinated pesticides using membrane introduction mass spectrometry (MIMS). A direct insertion membrane probe was modified so that a chemical ionization plasma could be established at the membrane surface. Using selected ion monitoring (SIM) in a tandem triple quadrupole mass spectrometer with isobutane chemical ionization (CI), the PCP detection limit under positive chemical ionization is 20 ppb whereas negative CI gives detection limits in the low ppb range. This performance is achieved without any pre-treatment or derivatization of the sample. Negative ion CI gives a signal that is linear over a concentration range of 2-1000 ppb. Comparison of data obtained with low ppb samples of 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol and pentachlorophenol suggests that the sensitivity of this analytical procedure increases with increase in the number of electronegative substituents in the molecule.  相似文献   

4.
Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).  相似文献   

5.
Solid phase micro-extraction (SPME) was applied to the determination of volatile organic compounds (VOC) in wastewater discharges. Environmentally significant samples, typical of those subject to regulatory control, were examined and included discharges from pharmaceutical, petrochemical and municipal sewerage treatment plants. Analysis was performed using gas chromatography – mass spectrometry (GC-MS) following sampling using headspace or immersion SPME. Fused silica fibres, coated with either poly(dimethylsiloxane) or poly(acrylate), were examined to determine VOC which included chloroform, saturated carboxylic acids, alkylbenzenes, phenol, benzonitrile and benzofuran. Detection limits varied from 10 to 170 ng/ml and satisfactory relative standard deviations (%RSD < 10) were obtained. For most samples, headspace sampling was preferred to immersion. SPME was found to be a useful technique for the rapid screening of wastewaters for VOC.  相似文献   

6.
A fast and simple screening procedure using solid‐phase microextraction and gas chromatography‐mass spectrometry (SPME‐GC‐MS) in full‐scan mode for the determination of volatile organic compounds (VOC) is presented. The development of a fast and simple screening technique for the simultaneous determination of various volatiles is of great importance, because of their widespread use, frequent occurrence in forensic toxicological questions and the fact that there is often no hint on involved substances at the crime scene. To simulate a screening procedure, eight VOC with different chemical characteristics were chosen (isoflurane, halothane, hexane, chloroform, benzene, isooctane, toluene and xylene). To achieve maximum sensitivity, variables that influence the SPME process, such as type of fiber, extraction and desorption temperature and time, agitation and additives were optimized by preliminary studies and by means of a central composite design. The limits of detection and recoveries ranged from 2.9 µg/l (xylene) to 37.1 µg/l (isoflurane) and 7.9% (chloroform) to 61.5% (benzene), respectively. This procedure can be used to answer various forensic and toxicological questions. The short time taken for the whole analytical procedure may make its eventual adoption for routine analysis attractive. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
8.
This article presents the results of an exploratory application of the Solid Phase MicroExtraction (SPME) technique to the analysis of BTEX (benzene, toluene, ethylbenzene and xylenes) at the microg/m3 level in outdoor and indoor air. The salient features of the method validation are reported. As shown by the various examples of field sampling described, SPME technique appears as a method of choice for fast qualitative analysis and quantitative determination of Volatile Organic Compounds (VOC). The small dimensions of the SPME sampling system and the short sampling time let envisage its utilisation for the rapid diagnostic of outdoor and indoor air quality.  相似文献   

9.
L S Riter  Z Takáts  R G Cooks 《The Analyst》2001,126(11):1980-1984
Construction, optimization, and testing of a novel single-sided configuration for a semi-permeable [poly(dimethylsiloxane); PDMS] membrane introduction system for mass spectrometry is described. On-line detection of semi-volatile organic compounds of environmental interest is shown, including lindane (a pesticide), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) (an explosive), butylated hydroxytoluene (BHT) (an antioxidant), 1,2-dichlorobenzene, dimethylmethyl phosphonate (DMMP) (a chemical warfare agent simulant) and naphthalene. The technique has limits of detection in the sub-ppb range. with rise times of 4 to 7 s and fall times of 12 to 36 s and a response that is linear over 4 orders of magnitude (from 0.1 ppb to 1000 ppb for DMMP). The cycle time, from crude air sampling to acquisition of results, is approximately 1 min. No sample preparation is necessary.  相似文献   

10.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

11.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

12.
A 252Cf plasma desorption mass spectrometer has been set up to analyse thin layers of non-volatile organic samples. Molecular and fragment ions were produced and their mass was determined by a time-of-flight measurement. A novel interface combines a high-performance liquid chromatograph with the 252Cf plasma desorption mass spectrometer in a twofold way: introducing the effluent continuously through a capillary inlet in the on-line liquid chromatography mass spectrometry mode or transferring already prepared samples through a vacuum lock into the mass spectrometer in the off-line liquid chromatography+mass spectrometry mode. The off-line mode has been applied for the quantitative analysis of pharmaceuticals in blood using stable isotope labelled standards.  相似文献   

13.
By its simplicity and rapidity, solid-phase microextraction (SPME) appears as an interesting alternative for sample introduction in fast gas chromatography (fast GC). This combination depends on numerous parameters affecting the desorption step (i.e., the release of compounds from the SPME fiber coating to the GC column). In this study, different liner diameters, injection temperatures, and gas flow rates are evaluated to accelerate the thermal desorption process in the injection port. This process is followed with real-time direct coupling a split/splitless injector to a mass spectrometer by means of a short capillary. It is shown that an effective, quantitative, and rapid transfer of cocaine (COC) and cocaethylene (CE) is performed with a 0.75-mm i.d. liner, at 280 degrees C and 4 mL/min gas flow rate. The 7-microm polydimethylsiloxane (PDMS) coating is selected for combination with fast GC because the 100-microm PDMS fiber presents some limitations caused by fiber bleeding. Finally, the developed SPME-fast GC method is applied to perform in less than 5 min, the quantitation of COC extracted from coca leaves by focused microwave-assisted extraction. An amount of 7.6 +/- 0.5 mg of COC per gram of dry mass is found, which is in good agreement with previously published results.  相似文献   

14.
The successful application of polypyrrole (PPY) solid-phase microextraction (SPME) coatings as both an extraction phase and a surface to enhance laser desorption/ionization (SELDI) of analytes is reported. This SPME/SELDI fiber integrates sample preparation and sample introduction on the tip of a coated optical fiber, as well as acting as the transmission medium for the UV laser light. Using ion mobility spectrometry (IMS) detection, the signal intensity was examined as a function of extraction surface area and concentration of analyte. The linear relationship between concentration and signal intensity shows potential applicability of this detection method for quantitative analysis. Extraction time profiles for the fiber, using tetraoctylammonium bromide as test analyte, illustrated that equilibrium can be reached in less than one minute. To investigate the performance of the PPY coating, the laser desorption profile was studied. The fiber was also tested using a quadrupole time-of-flight (Q-TOF) mass spectrometer with leucine enkephalin as test analyte. Since no matrix was used, mass spectra free from matrix background were obtained. This novel SPME/SELDI fiber is easy to manufacture, and is suitable for studying low-mass analytes because of the intrinsic low background. These findings suggest that other types of conductive polymers could also be used as an extraction phase and surface to enhance laser desorption/ionization in mass spectrometry.  相似文献   

15.
《Analytical letters》2012,45(14):2851-2870
ABSTRACT

An analytical method for the determination of 15 Volatile Organic Compounds (VOC): benzene, n-heptane, toluene, n-octane, chlorobenzene, ethylbenzene, m-xylene, o-xylene, p-xylene, isopropylbenzene, n-propylbenzene, n-decane, 1,4-dichlorobenzene, 1,3-dichlorobenzene and 1,2-dichlorobenzene, by thermal desorption coupled with gas chromatography (GC) was proposed. The flame ionisation detector (FID) and mass spectrometry (MS) detector were used. The variables that have an influence on the desorption process (time, inert gas flow and temperature) were studied, obtaining detection limit ranges from 15 to 120 pg (GC-FID), 3.8 to 32 pg (GC-MS, SIM mode) and 15 to 300 pg (GC-MS, SCAN mode). In order to detect possible VOC urban sources, samples were taken from 6 points in A Coruña (N.W. Spain) to analyse. Sampling time and flow rate were 30 minutes and 50 mL/min respectively. VOC profile and their total concentrations can be considered as typical of an urban area. Other samples were also obtained from a nearly rural zone to determine the influence of these VOC sources.  相似文献   

16.
A novel membrane inlet interface coupled to a single-photon ionization (SPI) miniature time-of-flight mass spectrometer has been developed for on-line rapid measurement of volatile organic compounds (VOCs). The vacuum ultraviolet (VUV) light source for SPI was a commercial krypton discharge lamp with photon energy of 10.6 eV and photon flux of 10(10) photons/s. The experimental results showed that the sensitivity was 5 times as high as obtained with the traditional membrane inlet. The enrichment efficiency could be adjusted in the range of 10 to 20 times for different VOCs when a buffer cell was added to the inlet interface, and the memory effect was effectively eliminated. A detection limit as low as 25 parts-per-billion by volume (ppbv) for benzene has been achieved, with a linear dynamic range of three orders of magnitude. The rise times were 6 s, 10 s and 15 s for benzene, toluene and p-xylene, respectively, and the fall time was only 6 s for all of these compounds. The analytical capacity of this system was demonstrated by the on-line analysis of VOCs in single puff mainstream cigarette smoke, in which more than 50 compounds were detected in 2 s.  相似文献   

17.
A simple and rapid approach to obtaining target plates for the investigation of low-molecularweight compounds by surface-assisted laser desorption/ionization (SALDI) mass spectrometry is proposed. It consists in the vacuum sputtering of a carbon layer with a thickness of about 50 nm onto a metal surface. The resulting coatings are characterized by homogeneity, hydrophobicity, and high mechanical strength, which eliminates a possibility of mass spectrometer contamination. A comparison of the SALDI mass spectra of test compounds recorded using conventional carbon materials and carbon nanocoatings demonstrates advantages of the last named materials, such as high spectral resolution and the absence of spectral interferences at low m/z values.  相似文献   

18.
Sudden sampling introduction into a membrane inlet mass spectrometer (MIMS) considerably improves the selectivity of the membrane inlet and is therefore applicable even for compounds with low permeabilities through a silicone membrane. In this study the basics of cyclic non-steady-state sudden increase sample injection were studied using a three-membrane inlet and a portable sector double-focusing mass spectrometer. The operational parameters of the inlet system providing the most efficient enrichment of volatile organic compounds (VOCs) in air were defined. Simulation of the diffusion process following sudden sample introduction into the three-membrane inlet was also carried out. Experimental testing of the three-membrane inlet system with the cyclic sudden sample injection mode for benzene, toluene, styrene, and xylene in air was performed. The simulation and the experimental results demonstrated that, when this mode is used, the VOCs/nitrogen relative enrichment factor of samples introduced into the mass spectrometer equipped with a three-membrane inlet is increased by a factor of approximately 10(5) compared with a direct introduction method. This effect may be used to decrease detection limits of compounds obtained with mass spectrometry to decrease matrix flow through the inlet at the same detection limits.  相似文献   

19.
The dual nature of the quaternary ammonium compounds, having permanently charged hydrophilic quaternary ammonium heads and long-chain hydrophobic tails, makes the sample preparation step and analysis of these compounds challenging. A high-throughput method based on thin-film solid-phase microextraction (SPME) and liquid chromatography mass spectrometry was developed for simultaneous quantitative analysis of nine benzylic and aliphatic quaternary ammonium compounds. Chromatographic separation and detection of analytes were obtained in reverse-phase mode in 8 min using a triple quadrupole mass spectrometer. Hydrophilic lipophilic balance particle-coated blades were found to be the most suitable among the different coatings tested in terms of recoveries and carryover on the blades. For desorption solvents, 70/30, v/v (A/B) with 0.1 % formic acid (where A is 10 mM ammonium acetate in acetonitrile/water (95/5?, v/v) and B is 0.1 %? (v/v) formic acid in isopropyl alcohol) was shown to be the most efficient solvent for the desorption of the analytes from the SPME sorbent. The SPME method was optimised in terms of extraction, pH, and preconditioning, as well as extraction and desorption times. Optimum conditions were 45 min of extraction time and 15 min of desorption time, all with agitation. The extraction was found to be optimum in a range of pH 6.0 to 8.0, which is consistent with the natural pH of water samples. Wide linear dynamic ranges with the developed method were obtained for each compound, enabling the application of the method for a wide range of concentrations. The developed method was validated according to the Food and Drug Administration criteria. The proposed method is the first SPME-based approach describing the applicability of the high-throughput thin-film SPME in a 96-well system for analysis of such challenging compounds.  相似文献   

20.
Solid‐phase microextraction (SPME) has been directly coupled to an ion‐trap mass spectrometer (MS) for the determination of the model compound lidocaine in urine, hereby applying MS/MS [fragmentation of [M + H]+ (m/z 235) to a fragment with m/z 86]. The throughput of samples has been increased using non‐equilibrium SPME with polydimethylsiloxane (PDMS) fibers. The effect of temperature on the sorption and the desorption was studied. Elevated temperatures during sorption (65°C) and desorption (55°C) had a considerable influence on the speed of the extraction. The desorption was carried out with a home‐made desorption chamber allowing thermostating. Only 1 min sorption and 1 min desorption were performed, after which MS detection took place, resulting in a total analysis time of 3 min. Detection limits below 1 ng/mL could be obtained despite yields of only 2.1 and 1.5% for a 100‐ and a 30‐μm PDMS‐coated fiber, respectively. Furthermore, the determination of lidocaine in urine had acceptable reproducibilities, i.e., relative standard deviations (RSDs) below 10%. A limit of quantitation (RSD < 15%) of about 1 ng/mL was obtained. No extra wash step of the extraction fiber was required after desorption if a 30‐μm coating was used, whereas not all the analyte was desorbed from the 100‐μm coating in a single desorption. Therefore, the SPME‐MS/MS system with a 30‐μm PDMS‐coated fiber for rapid non‐equilibrium SPME at elevated temperatures has interesting potential for high‐throughput analysis of biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号