首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An evaluation was made of the feasibility of using reversed-phase liquid chromatography/tandem mass spectrometry with an electrospray interface (LC/ESI-MS/MS) to measure traces of phenoxyacid herbicides and their metabolites in surface and drinking water samples. The procedure involved passing 0.5 L of river and drinking water samples through a 0.5 g graphitized carbon black (GCB) extraction cartridge. Recovery was higher than 85% irrespective of the aqueous matrix in which the analytes were dissolved. A conventional 4.6-mm i.d. reversed-phase LC C-18 column operating with a mobile phase flow rate of 1 mL/min was used to chromatograph the analytes. A flow of 200 microL/min of the column effluent was diverted to the ESI source. The limits of detection (signal-to-noise ratio = 3) of the method for the pesticides considered in drinking and surface water samples are less than 0.1 ng/L for phenoxyacid herbicides, and about 5-10 ng/L for their metabolites (2,4-dichlorophenol and 4-chloro-2-methylphenol).  相似文献   

2.
张续  韩林学  邱天  胡小键  朱英  杨艳伟 《色谱》2023,41(3):224-232
基于96孔固相萃取-超高效液相色谱-串联质谱法,建立了人尿中2种苯氧乙酸除草剂、2种有机磷农药代谢物和4种拟除虫菊酯农药代谢物的测定方法。通过对液相色谱条件、质谱条件和样品前处理过程的系统优化,实现了在16 min内对8种目标分析物的分析测定。具体方法:1 mL尿液经β-葡萄糖醛酸酶酶解过夜,Oasis HLB 96孔固相萃取进行目标分析物的提取净化,甲醇洗脱;以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水作为流动相,Acquity BEH C_(18)作为分析柱进行色谱分离;负离子电喷雾(ESI-)多反应监测(MRM)模式下检测目标化合物,同位素内标法定量。2,4-二氯苯氧乙酸(2,4-D)、2,4,5-三氯苯氧乙酸(2,4,5-T)2种苯氧乙酸除草剂和3-苯氧基苯甲酸(3-PBA)、4-氟-3-苯氧基苯甲酸(4F-3PBA)、反式二氯乙烯基二甲基环丙烷羧酸(trans-DCCA)3种拟除虫菊酯农药代谢物在0.1~100μg/L内、对硝基苯酚(PNP)、3,5,6-三氯-2-吡啶酚(TCPY)2种有机磷农药代谢物、顺式二氯乙烯基二甲基环丙烷羧酸(cis-DCCA)1种拟除虫菊酯代谢物在0.2~100μg/L内线性关系良好,相关系数均大于0.9993;方法检出限为0.02~0.07μg/L,方法定量限为0.08~0.2μg/L;低、中、高3个水平下的加标回收率为91.1%~110.5%,日内精密度为2.9%~7.8%,日间精密度为6.2%~10%。应用该方法测定了214份尿液样本。结果显示除2,4,5-T外,其余7种目标分析物均有检出。TCPY、PNP、3-PBA、4F-3PBA、trans-DCCA、cis-DCCA、2,4-D的检出率为2.8%~99.1%。检出浓度(中位值)由高到低分别是2.0μg/L(TCPY)、1.8μg/L(PNP)、0.99μg/L(trans-DCCA)、0.81μg/L(3-PBA)、0.44μg/L(cis-DCCA)、0.35μg/L(2,4-D)和未检出(4F-3PBA)。该方法操作简便,定量准确,灵敏度高,每批次可完成96个样品测定,适用于人尿中多种农药及农药代谢物的批量分析测定。  相似文献   

3.
An analytical method combining disk solid-phase extraction with micellar electrokinetic chromatography has been developed for the determination of atrazine, simazine, hydroxyatrazine, deisopropylatrazine, deethylatrazine, propazine and prometryn in water samples. The influence of the buffer and sodium dodecyl sulfate (SDS) concentration, pH and organic modifier on the separation has been studied. Baseline separation of the seven triazines was achieved under the following conditions: 10 mM borate buffer, 60 mM SDS, 20% methanol and pH 9.2. C18-bonded silica and poly(styrene-divinylbenzene) (PS-DVB) disks were evaluated for solid-phase extraction of the selected pesticides (11 of water sample). Using two PS-DVB disks, quantitative recoveries were obtained for all pesticides tested. The method was successfully applied for the determination of the seven triazines in drinking and well water at the 0.1 microg l(-1) and 0.5 microg l(-1) concentration levels, respectively. The detection limits for these analytes using the proposed analytical method were within the 0.02-0.06 microg l(-1) range in drinking water and the 0.06-0.30 microg l(-1) range in well water.  相似文献   

4.
This study developed a method to perform the simultaneous concentration and selective separation of66(ultra) trace persistent toxic substances in Antarctic waters. The substances included 30 polychlorinated biphenyls, 17 organochlorine pesticides, 16 polycyclic aromatic hydrocarbons, 3hexabromocyclododecanes. Solid phase extraction was performed using a C18 membrane and silica gel column. Gradient elution was conducted using organic solvents with different polarities; as a result, the efficiency of the C18 film is improved and the interferences from impurities and target compounds are eliminated. Extracts were subsequently analyzed through gas chromatography or liquid and gas chromatography coupled to tandem mass spectrometry. Method validation yielded the following values:recoveries of all target analytes in the Antarctic water ranged from 87.3% to 117.6% and reproducibility as percent relative standard deviation was lower than 5%. Quantification limits ranged from 0.004 mg L 1[2_TD$IF]to0.030 mg L 1. The established method improved the recoveries and reduced the limits of detection.Results indicated the method exhibited good performance in the simultaneous concentration and selective separation of 66(ultra) trace organic pollutants; Therefore, the proposed sample pretreatment can potentially eliminate the effects of various classes of impurities to some extent.  相似文献   

5.
A new sample pre-treatment technique termed cone-shaped membrane liquid phase microextraction (CSM-LPME) was developed and combined with micro-liquid chromatography (micro-LC) for the determination of selected pesticides in water samples. Four pesticides (hexaconazole, procymidone, quinalphos and vinclozolin) were considered as target analytes. Several important extraction parameters such as types of extraction solvent, agitation rate, pH value, total exposure time and effect of salt and humic acids were optimized. Enrichment factors of > 50 folds were easily achieved within 20 min of extraction. The analytical data demonstrated relative standard deviations for the reproducibility of the optimized CSM-LPME method ranging from 6.3 to 7.5%. The correlation coefficients of the calibration curves were at least 0.9995 across a concentration range of 2-100 microg/L. The detection limits for all the analytes were found to be in the range of 1.1-1.9 microg/L.  相似文献   

6.
Organophosphorus pesticides are commonly used in both agricultural and residential settings. The widespread use of these chemicals makes it almost impossible for humans to avoid exposure. In order to determine background human exposure, there is a need for fast, reliable, and sensitive analytical methods. We have developed a sensitive method to quantify specific biomarkers of the organophosphorus pesticides acephate, azinphos, chlorpyrifos, coumaphos, diazinon, isazofos, malathion, methamidophos, parathion and pirimiphos or their O,O-dimethyl analogues in human urine, as their selective metabolites or as the intact pesticide. Isotopically labeled internal standards were used for eight of the analytes. The use of labeled internal standards in combination with high-performance liquid chromatography electrospray ionization–tandem mass spectrometry provided a high degree of specificity. Repeated analysis of urine samples fortified with high and low concentrations of the analytes gave relative standard deviations (RSD) of less than 10% for the analytes with an isotopically labeled standard. Analytes without isotopically labeled standards had higher RSD. For all compounds except methamidophos and acephate, the recoveries were greater than 70%. The limits of quantification for most of the analytes were in the range of 0.1 to 1 ng/mL. We detected concentrations of most of these pesticides and/or their metabolites in urine samples from non-occupationally exposed persons using our method. Our frequencies of detection for the analytes measured ranged from 1% to 98%.  相似文献   

7.
用毛细管胶束电动色谱成功分离并测定了高粱和玉米中7种农药类环境激素(多菌灵、西玛津、莠去津、毒死蜱、溴氰菊酯、乙草胺和氯氰菊酯)的残留量。研究了电泳缓冲液及表面活性剂等因素的影响,在最佳分离条件(pH 9.0、20 mmol/L磷酸氢二钠+50 mmol/L SDS+5%乙腈为缓冲溶液,分离电压20 kV,检测波长222 nm,实验温度25℃,压力法进样,30 mbar×10 s)下,7种农药在28 min内得到基线分离,质量浓度与其峰面积在5.0~150μg.L-1范围内呈良好线性,检出限为0.6~3.0μg/L,回收率为97%~108%,相对标准偏差为2.2%~4.7%。该方法具有操作简单、快速方便及自动化程度高、重现性好等优点。  相似文献   

8.
建立了梯度洗脱优化-离子色谱-脉冲安培检测技术分析婴幼儿配方乳粉中麦芽糖醇、半乳糖、葡萄糖、蔗糖、果糖、乳糖6种与代谢疾病紧密相关的糖和糖醇的方法。该方法对样品的前处理、色谱柱的选择、淋洗液的梯度等色谱条件进行了优化,重点研究了淋洗液梯度对各组分分离效果的影响。将梯度洗脱程序分解为弱保留组分分离、乳糖分离、基质消除、系统平衡4个子程序,并分别对其进行了条件优化,实现了6种组分的完全分离,并有效解决了弱保留组分色谱峰易重叠、乳糖色谱峰易拖尾等现象。6种组分的线性范围为0.5~100 mg/L,相关系数(r)>0.99,方法的检出限(S/N=3)为0.06~0.40 mg/L。该方法具有分离度好、灵敏度高等优点,可满足例行分析的要求,同时也为淋洗液的梯度优化提供了可借鉴的方法。  相似文献   

9.
This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic profiles, which in turn resulted in better detectability. In addition, IT-SPME allowed the direct injection into the chromatographic system of sample volumes as large as 200 μL, thus making unnecessary off-line clean-up and concentration steps. In such a way, the tested compounds could be directly analysed in less than 10 min, the limits of detection (LODs) being 10 and 1.2 μg/L for coprostanol and cholesterol, respectively. The reliability of the proposed method was tested by processing several wastewater samples.  相似文献   

10.
A simple multidimensional system for direct injection of large volumes has been developed for the determination of three naphthalene-derivative pesticides [2-(1-naphthyl) acetamide (NAD), 1-naphthyl methylcarbamate (carbaryl) and 1-naphthol] in water using fluorescence detection. The capability of restricted-access medium (RAM), pre-columns for eliminating large interfering molecules, combined with an optimised, coupled-column separation procedure, large volume injection (LVI) and fluorescence detection, gave excellent sensitivity for target analytes. The maximum admissible concentration levels established by the European Union (EU) for individual pesticides and their related compounds in drinking water (0.1 μg L?1) were easily reached. Detection limits were lower than, or equal to, 0.003 μg L?1. Average recoveries ranged: 81–104% (n=3) with relative standard deviation (RSD) values: 2–7%. Application of the coupled-column liquid chromatography (LC-LC) method was by determining target analytes in ground water samples from five agricultural zones of Almería, (Spain) over three months.  相似文献   

11.
A sample pretreatment method based on microporous membrane liquid-liquid extraction (MMLLE) was developed for the subsequent gas chromatographic determination of pesticides in wine. MMLLE provided efficient and selective extraction with enrichment factors in the range 3-13. The gas chromatographic separation was carried out using on-column injection and flame ionization detection. The method was linear, repeatable and sensitive. The limits of quantification were better than 0.006 mg/L for all the analytes except for iprodione (0.37 mg/L). The method was applied to the determination of pesticides in several red wines of different origin.  相似文献   

12.
反相高效液相色谱法分离测定烟草中的多酚类化合物   总被引:2,自引:0,他引:2  
李福娟  蔡文生  邵学广 《色谱》2007,25(4):565-568
对植物中9种多酚类化合物的色谱分离条件进行了优化,分别探讨了流动相组成、流动相中醋酸浓度、醋酸溶液与甲醇的比例对保留时间的影响,确定了梯度分离条件,并对9种天然多酚类化合物进行了定量分析。该方法的检测限为13.26~59.29 mg/kg (S/N=3)。在3.0~100.0 mg/L 范围内呈良好的线性关系,相关系数r2为 0.9979~0.9999。9种待测化合物的加标回收率为96.8%~108%,相对标准偏差(RSD)小于3.8% (n=3)。用80%甲醇超声提取烟草样品,并通过优化的色谱条件对其进行分析,测定了实际烟草样品中芸香苷和绿原酸的含量。结果表明,该方法具有一定的实用价值。  相似文献   

13.
Molina M  Silva M 《Electrophoresis》2001,22(6):1175-1181
The potential of micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection for the separation and determination of phosphorus-containing amino acid-herbicides (glufosinate and glyphosate), and aminomethylphosphonic acid (the major metabolite of glyphosate), involving derivatization with fluorescein isothiocyanate (FITC) isomer I, was investigated. Different variables that affect derivatization (pH, FITC concentration, time and temperature) and separation (pH and concentration of the buffer, kind and concentration of surfactants and applied voltage) were studied. The analysis was conducted within about 8 min and the use of the nonionic surfactant Triton X-100 improved the selectivity, thus indirectly enhancing sensitivity by shifting of the interfering peaks of the FITC excess. Dynamic ranges of 2.0-3,000 microg/L, limits of detection at microgram or submicrogram-per-liter level, and relative standard deviations from 4.7 to 6.4% were obtained. The ensuing method--nonionic surfactant MEKC-- is a useful choice for the determination of these herbicides as it provides limits of detection similar or lower than those reported by existing chromatographic alternatives without the use of an additional preconcentration technique such as solid-phase extraction. The separation of a mixture of nine FITC-derivatized amino acids, selected as target compounds, was also carried out to assess the discrimination power of the nonionic surfactant MEKC method for the analysis of closely related anionic analytes.  相似文献   

14.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

15.
研究了离子色谱-直接电导检测法分离测定离子液体中的卤素离子(F~-、Cl~-、Br~-)杂质.采用Shim-pack IC-A3阴离子交换色谱柱,考察了淋洗液种类及浓度、流速和色谱柱温度对分离测定的影响.最佳色谱条件为:以1.25 mmol/L邻苯二甲酸氢钾为淋洗液,流速1.5 mL/min,色谱柱温45 ℃.在此条件下可以基线分离卤素离子,且NO~-_3、BF~-_4、SO~(2-)_4不干扰测定.该法测定卤素离子的检出限(S/N=3)为0.02 ~0.11 mg/L,峰面积的相对标准偏差(n=5)不大于0.7%,F~-、Cl~- 和Br~- 的标准曲线的线性范围分别为0.1 ~50、0.1 ~50、0.5 ~100 mg/L.将方法用于烷基咪唑四氟硼酸盐离子液体中卤素离子杂质的测定,加标回收率为98% ~102%.  相似文献   

16.
朱会宇  吴丹妮  汪海林 《色谱》2017,35(1):54-58
研究了三磷酸腺苷(ATP)及其代谢物在细胞内的含量以及2-叔丁基-1,4-苯醌(TBBQ)对ATP及其代谢产物在细胞内含量的影响。建立了一种高效液相色谱法(HPLC)用于快速分离、检测细胞内ATP及其代谢产物(二磷酸腺苷(ADP)和一磷酸腺苷(AMP))的含量。使用岛津高效液相系统及艾杰尔Venusil MP C18柱,采用等度洗脱的方式。流动相A相为50 mmol/L磷酸氢二钠和15 mmol/L三甲胺(TEA),用醋酸(HAc)调节pH至7.88;流动相B相为甲醇。采用建立的高效液相色谱法得到了3种代谢物的工作曲线,相关系数高(R~2≥0.999 6),MRC-5细胞中3种代谢物的含量均在线性范围(0.1~100μmol/L)内。该方法检出限低。采用预冷的80%(体积分数)甲醇水溶液提取细胞内的代谢物。该研究建立的方法成功地应用于检测MRC-5细胞中的ATP、ADP和AMP的含量,结果表明,TBBQ会对ATP、ADP、AMP在细胞内的含量产生影响,但TBBQ浓度和ATP、ADP以及AMP在MRC-5细胞内浓度的关系比较复杂。  相似文献   

17.
An automatic method for the determination of organochlorine pesticides (OCPs) in water samples was developed. The analytes are preconcentrated onto a customized RP-C(18) column and subsequently eluted with 80 mul of ethyl acetate. Gas chromatography with electron capture detection is used for their separation and selective detection. Detection limits for 10 ml sample volumes range from 0.01 to 0.1 ng ml(-1), with standard deviations between 4 and 6%. The average recovery at a fortification level of 2 ng ml(-1) is 92%. The method was used to screen OCPs in natural waters collected near agricultural areas and also to tap waters. Positive findings were confirmed by gas chromatography with mass spectrometric detection. Finally, the adsorption/degradation of OCPs in natural pond water containing a high level of suspended matter was examined; some OCPs were found to be degraded and irreversibly adsorbed on suspended matter present in the water.  相似文献   

18.
A multi-residue method for the simultaneous extraction from drinking water using solid-phase extraction on LiChrolut EN [poly(styrene-divinylbenzene), PSDVB] and determination of nine N-methylcarbamate pesticides (NMCs) (aldicarb, its metabolites i.e. aldicarb sulfone and aldicarb sulfoxide and carbaryl, carbofuran, dioxacarb, ethiofencarb, methomyl and propoxur) using reversed-phase liquid chromatography was studied. A 1000-fold pre-concentration was achieved and the method was used for determination of the nine pesticides in water, with limits of detection in the range 3-15 ng L(-1). For all compounds the recoveries determined at the 0.1 and 1 microg L(-1) level generally ranged from 85 to 104% with relative standard deviations (RSD) of 1.4-8.8%.  相似文献   

19.
A new method is presented for the determination of 12 acidic pharmaceuticals (non-steroidal anti-inflammatory drugs and bezafibrate), including two metabolites from aqueous samples, together with triclosan as a personal care product. Ion-pair liquid chromatography (IP-LC) with electrospray ionisation tandem mass spectrometry (ESI-MS) in the negative ion mode was employed. The ion-pairing agent (tri-n-butylamine) increased the signal intensity for all acidic analytes and detection limits of 6-200 ng/L were obtained by multiple reaction monitoring. This allows analysis of wastewater samples by direct injection into the LC/MS system without the need for a preceding enrichment step. When combined with a solid-phase extraction (SPE) step, limits of quantification between 0.15 and 11 ng/L were obtained from 100-mL sample volumes, which is adequate for most applications. The occurrence of matrix effects was studied and standard addition was required for reliable quantification after SPE from wastewater. The method was finally applied to surface and wastewaters, with analyte concentrations ranging from below the detection limit up to 5.5 microg/L.  相似文献   

20.
以月桂酸表面活性剂和氨水组成缓冲溶液,建立了毛细管胶束电动色谱快速测定七种氨基甲酸脂类农药的方法。对电泳介质的种类及浓度、pH值、操作电压和进样时间等影响因素进行了优化,以45 mmol/L月桂酸(乙醇溶)和120 mmol/L氨水(用0.1 mol/L NaOH调至pH=9.5)为电泳介质,在4.5 min内实现对速灭威、残杀威、克百威、抗蚜威、异丙威、硫双威、双氧威的分离检测。结合固相萃取(SPE)对农田水样进行测定,各农药检出限为2.0~15μg/L,回收率为85%~107%,相对标准偏差为4.3%~8.3%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号