共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a novel method for providing broadcast signal transmission in a wavelength division multiplexing passive optical network (WDM-PON).An unmodulated optical carrier for downstream transmission and a pair of unmodulated single-side band subcarriers are utilized for broadcast delivery and upstream transmission,respectively.System performance at 2.5-Gb/s down/upstream and 2.5-Gb/s broadcast transmission is also investigated. 相似文献
2.
Energy-efficiency and green communications have become dominant topics related to access network implementation, since their energy consumption is a major contributor of energy consumption within the Internet. In this paper we analyze an implementation of a new energy-efficient dynamic bandwidth algorithm in a four-channel Wavelength Division Multiplexing Ethernet Passive Optical Network (WDM EPON), in which wavelength assignments take place per service class and not per Optical Network Unit (ONU). The improved Dynamic Bandwidth Allocation (DBA) algorithm introduces independent bandwidth allocation for each wavelength, which results in efficient bandwidth management and utilization. The mathematical model for new DBA algorithm is described, as are changes to the Multi-Point Control Protocol (MPCP), necessary for its implementation. The obtained results show that the redefined DBA algorithm improves Key Performance Indicators (KPIs) and as a consequently enables delivery of enhanced services to end-users. Significant energy savings are achieved without Quality of Service (QoS) degradation, and without network or equipment architecture changes. 相似文献
3.
4.
5.
Wei Han Ning-Hua Zhu Liang Xie Min Ren Ke Sun Bang-Hong Zhang Liang Li Hong-Guang Zhang 《Optics Communications》2009,282(17):3553-3557
In this paper, a protection scheme for transmitters in wavelength-division-multiplexing passive optical network (WDM-PON) has been proposed and demonstrated. If any downstream transmitter encounters problems at the central office (CO), the interrupted communication can be restored immediately by injecting a Fabry-Perot laser diode (FP-LD) with the upstream lightwave corresponding to the failure transmitter. Compared with the conventional methods, this proposed architecture provides a cost-effective and reliable protection scheme employing a common FP-LD. In the experiment, a 1:36 protection capability was implemented with a 2.5 Gbit/s downstream transmission capability. 相似文献
6.
Amit Kumar Garg 《Optik》2011,122(8):691-696
To avoid burst collision in OBS-WDM ring network, a novel scheme called Estimated Traffic based Longest Queue First (ETLQF) has been proposed. In it, the scheduler considers both the queue length and the incoming traffic. The scheduler can adjust the queue lengths in advance to cater to the incoming traffic, targeting to reduce cell loss ratio (CLR) and improve the buffer utilization. The simulation results show that the ETLQF in OBS ring networks not only reduces CLR by 10-60%, but also achieves high throughput while saving 65% of wavelengths, when compared to conventional schemes with only destination delay. 相似文献
7.
In this paper a 32×32 optical wavelength switching network using the multi-channel and multi-wavelength spectrum-sliced light source is presented where the 2×2 optical-switching elements are utilized in dilated Benes and modified dilated Benes configurations, respectively. The system performances in bit-error rate, especially for the effects of intraband crosstalk, are analyzed in details for the two type networks. Through the simulation studies, the dilated Benes shows better performances than the modified dilated Benes configuration. 相似文献
8.
A new method, called temporal orthogonalization, for the cancellation of multiple reflections in distance-multiplexed all-optical passive tree networks is presented. The main advantage of this method over an existing method with Faraday rotators is its relatively simple implementation in the network nodes. 相似文献
9.
10.
A new self-protected apparatus in ring-star-architecture for time division multiplexed passive optical network (TDM-PON) against fiber-fault; together with triple-play management in optical layer is proposed and investigated. Different scenarios of fiber-fault locations are also discussed and analyzed. Besides, the performance of data traffics in both uplink and downlink directions are also measured and studied. Standard CATV video signal distribution to each ONUs is also performed, showing the proposed access network cannot only have self-restored function, but also can manage triple-play services in the optical layer. 相似文献
11.
In this paper, we have analyzed the signal processing methods both in digital and optical domain to enhance the transmission performance of downstream signalling in long reach passive optical networks (LR-PONs). The impact of non-linear (NL) equalization through signal processing, i.e. Volterra Equalization (VE), Digital Backpropagation (BP) and Optical Phase Conjugation with Non-linearity Module (OPC-NM) is investigated, in 10 Gbit/s (XG) DP-QPSK long-reach wavelength division multiplexed (WDM) PONs without midspan repeaters over 120 km standard single mode fibre (SMF) link for down-stream signals. Due to the compensation of optical Kerr effects, the sensitivity penalty is reduced to 2 dB by BP algorithm, 1.5 dB by VE algorithm and 2.69 dB by OPC-NM. Moreover, with the implementation of NL equalization technique we are able to get the transmission distance of 126.6 km SMF for the 1:1024 split-ratio at 5 GHz channel spacing in the non-linear region. Furthermore, the concept of super passive optical network (S-PON) is also evaluated, which involves a repeater stage consisting of optical amplifiers, to study the feasibility for receiver side signal processing and simplification. 相似文献
12.
This paper proposes and numerically investigates a novel high-speed wavelength-division-multiplexed passive optical network (WDM-PON) architecture with colorless user terminals based on the use of orthogonal modulation scheme for downstream and upstream transmission. The 40 Gb/s optical frequency shift keyed (FSK) downstream data is generated based on carrier-suppressed modulation. At optical network unit, the downstream signal is directly re-modulated by the 2.5 Gb/s up-stream data and sent back with the same fiber. Error free transmission over 20 km single mode fiber can be observed for both downstream and upstream signals in our simulation. Power budget, tolerance of channel spacing, FSK tone spacing and dispersion are all investigated. Factors that might influence the stability of the system are analyzed and an extended hybrid wired/wireless version of the scheme is also given. 相似文献
13.
报道了一种新型的专用于光学相干层析系统的输出光谱为准高斯型的宽带超荧光光纤光源.该光源采用掺饵光纤作为增益介质.其关键技术是在抽运源的输出端增加了光耦合器,并在光源输出端插入多级长周期光纤光栅对铒离子的自发光谱进行调制和整形;同时采用光控器和温控器来控制抽运源的输出以提高光源输出功率的稳定性.该光源的中心波长为1.57μm,输出光谱的3dB带宽大于75nm,输出功率为27mW.实验结果表明,该光源输出光谱的自相关函数的旁瓣峰被大大削弱,可以满足光学相干层析系统的应用.
关键词:
光学相干层析术
超荧光光纤光源
长周期光纤光栅
光耦合器 相似文献
14.
使用近场光学显微术(scanning near-field optical microscopy, SNOM)研究了ZnO亚微米线端面出射性质,不同空间形貌Ⅱ-Ⅵ族半导体荧光器件光波导特性,二维光子晶体、准晶光子晶体对LED的出射增强作用以及表面等离激元(surface plasmon polariton, SPP)与半导体纳米荧光器件的相互作用,对纳米集成光路中的光源、光波导、光增强三个重要问题做了实验和理论上的分析.研究发现半导体微纳米线端面出射光束的质量与样品的直径有密切关系.通过合理地设计其直径和 相似文献
15.
使用近场光学显微术(scanning near-field optical microscopy, SNOM)研究了ZnO亚微米线端面出射性质,不同空间形貌Ⅱ-Ⅵ族半导体荧光器件光波导特性,二维光子晶体、准晶光子晶体对LED的出射增强作用以及表面等离激元(surface plasmon polariton, SPP)与半导体纳米荧光器件的相互作用,对纳米集成光路中的光源、光波导、光增强三个重要问题做了实验和理论上的分析.研究发现半导体微纳米线端面出射光束的质量与样品的直径有密切关系.通过合理地设计其直径和
关键词:
纳米集成光路
扫描近场光学显微术
光波导
光增强 相似文献
16.
Y. Su Y. Tian E. Wong N. Nadarajah C.C.K. Chan 《Laser \u0026amp; Photonics Reviews》2008,2(6):460-479
We review recent progress on all‐optical virtual‐private‐network (VPN) schemes in passive optical networks (PONs). PON is a promising candidate in future access areas to provide broadband services with low cost. With all‐optical virtual private network (VPN) function, PON can support efficient internetworking among end users with dedicated optical channels, thus enabling guaranteed bandwidth and enhanced security at the physical layer. Here, we discuss and compare existing schemes of all‐optical VPNs in time‐division‐multiplexed (TDM) PONs, and also recently proposed schemes for deployment in wavelength‐division‐multiplexed (WDM) PONs and two‐stage TDM/WDM PONs. 相似文献
17.
在使用LED作为照明光源的过程中,光场作为LED应用中的关键因素,一般使用二次光学系统进行调控。但是二次光学系统一般设计复杂、体积大、重量重,随着LED光学封装系统朝着小型化方向发展,二次光学系统的应用将会变得困难。结合软件仿真和实验验证探索了用于单片集成发光二极管(MI-LED)的一次光学透镜的光场调控功能。研究结果表明,仿真和实验LED光源的光场几乎重合一致,所设计的一次透镜将LED光源的光束角从120°调控到48°~72°范围内。与未加一次透镜的LED光源相比,加一次透镜的LED光源具有更高的光提取效率和更均匀的空间光色分布。 相似文献
18.
The simultaneous baseband and broadcasting signal transmission based on wavelength division multiplexing-passive optical network access network are proposed and their experimental verifications are shown. Amplified spontaneous emitting source modulated by broadcasting signal in radio frequency band at reflective semiconductor optical amplifier is provided as seed source for wired signal modulation. The filtered amplified spontaneous emitting source is aligned to each channel and modulated by the downlink baseband signal at RSOA. Simultaneous downstream transmission of baseband and broadcasting signals over 23-km SMF is experimentally verified. Mutual interference between broadcasting and baseband signals, nonlinearity by two tone analysis, and performance variation on temperature are investigated. 相似文献
19.
On the framework of coherence theory we discuss the averaged temporal intensity output provided by real-time optical Fourier transformers when the spectral line shape of the stationary source is considered. Some numerical examples are given and the deviations from perfectly monochromatic sources are pointed out. 相似文献
20.
As wavelength division multiplexed passive optical networks (WDM-PONs) are expected to be first deployed to transport high capacity services to business customers, real-time knowledge of fiber/device faults and the location of such faults will be a necessity to guarantee reliability. Nonetheless, the added benefit of implementing fault monitoring capability should only incur minimal cost associated with upgrades to the network. In this work, we propose and experimentally demonstrate a fault monitoring and localization scheme based on a highly-sensitive and potentially low-cost monitor in conjunction with vertical cavity surface-emitting lasers (VCSELs). The VCSELs are used as upstream transmitters in the WDM-PON. The proposed scheme benefits from the high reflectivity of the top distributed Bragg reflector (DBR) mirror of optical injection-locked (OIL) VCSELs to reflect monitoring channels back to the central office for monitoring. Characterization of the fault monitor demonstrates high sensitivity, low bandwidth requirements, and potentially low output power. The added advantage of the proposed fault monitoring scheme incurs only a 0.5 dB penalty on the upstream transmissions on the existing infrastructure. 相似文献