首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wu S  Sun L  Ma J  Yang K  Liang Z  Zhang L  Zhang Y 《Talanta》2011,83(5):1748-1753
A poly (acrylamide-co-methylenebisacrylamide) (poly (AAm-co-MBA)) monolith was prepared by thermal polymerization in the 100 or 250 μm i.d. capillary. The monolithic support was activated by ethylenediamine followed by glutaraldehyde. Trypsin was then introduced to form an immobilized enzyme reactor (IMER). The prepared IMER showed a reliable mechanical stability and permeability (permeability constant K = 2.65 × 10−13 m2). With BSA as the model protein, efficient digestion was completed within 20 s, yielding the sequence coverage of 57%, better than that obtained from the traditional in-solution digestion (42%), which took about 12 h. Moreover, BSA down to femtomole was efficiently digested by the IMER and positively identified by matrix assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). To test the applicability of IMER for complex sample profiling, proteins extracted from Escherichia coli were digested by the IMER and further analyzed by nanoreversed phase liquid chromatography-electrospray ionization-mass spectrometry (nanoRPLC-ESI-MS/MS). In comparison to in-solution digestion, despite slightly fewer proteins were positively identified at a false discovery rate (FDR) of ∼1% (333 vs 411), the digestion time used was largely shortened (20 s vs 24 h), implying superior digestion performance for the high throughput analysis of complex samples.  相似文献   

2.
A hydrophilic immobilized enzyme reactor (IMER) containing trypsin was prepared and applied in the proteolysis of glycoproteins. Glycoproteins including horseradish peroxidase, asialofetuin, and fetuin were used to evaluate the performance of the hydrophilic IMER for the glycoprotein digestion. The digested products were detected by matrix-assisted laser desorption/ionization quadruple ion trap time-of-flight mass spectrometry and micro-high-performance liquid chromatography. The hydrophilic IMER showed higher enzymatic digestion efficiency compared with conventional in-solution digestion. The digestion time could be reduced from 16 h to several minutes. Furthermore, using microwaves as a heat source, the reproducibility of the hydrophilic IMER was evaluated and this IMER could be recycled for at least ten times without obvious loss of enzyme activity. The hydrophilic IMER provides a promising tool for high-throughput glycoproteome analysis.  相似文献   

3.
An automated proteolytic digestion bioreactor and droplet deposition system was constructed with a plastic microfluidic device for off-line interfacing to matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The microfluidic chips were fabricated in poly(methyl methacrylate) (PMMA), using a micromilling machine and incorporated a bioreactor, which was 100 microm wide, 100 microm deep, and possessed a 4 cm effective channel length (400 nL volume). The chip was operated by pressure-driven flow and mounted on a robotic fraction collector system. The PMMA bioreactor contained surface immobilized trypsin, which was covalently attached to the UV-modified PMMA surface using coupling reagents N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and hydroxysulfosuccinimide (sulfo-NHS). The digested peptides were mixed with a MALDI matrix on-chip and deposited as discrete spots on MALDI targets. The bioreactor provided efficient digestion of a test protein, cytochrome c, at a flow rate of 1 microL/min, producing a reaction time of approximately 24 s to give adequate sequence coverage for protein identification. Other proteins were also evaluated using this solid-phase bioreactor. The efficiency of digestion was evaluated by monitoring the sequence coverage, which was 64%, 35%, 58%, and 47% for cytochrome c, bovine serum albumin (BSA), myoglobin, and phosphorylase b, respectively.  相似文献   

4.
Peptide mapping analysis, utilizing an easily replaceable and regenerable on-column enzymatic microreactor with metal-ion-chelated adsorption of enzyme on magnetic silica microspheres, combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), was developed. Firstly, magnetic microspheres of small size and strong magnetism were prepared through solvothermal reaction. Thereafter, by introducing tetraethyl orthosilicate (TEOS), magnetic silica (MS) microspheres were formed. Trypsin could then be immobilized onto the MS microspheres based on the Lewis acid-base interaction through the divalent cation chelators such as iminodiacetic acid (IDA), which was chemically bound to the microspheres through the introduction of glycidoxypropyltrimethoxysilane (GLYMO). The trypsin-immobilized MS microspheres were then locally packed into the capillary by the application of a strong magnetic field using a magnet. The performance of the method was exemplified with digestion of bovine serum albumin for 5 min at 50 degrees C and the result was comparable to the 12 h in-solution digestion. The ability of regeneration of the prepared on-column microreactor and good reproducibility of microreactor before and after regeneration were also demonstrated.  相似文献   

5.
Trypsin digestion is a major component of preparing proteins for peptide based identification and quantification by mass spectral (MS) analysis. Surprisingly proteolysis is the slowest part of the proteomics process by an order of magnitude. Numerous recent efforts to reduce protein digestion to a few minutes have centered on the use of an immobilized enzyme reactor (IMER) to minimize both trypsin autolysis and vastly increase the trypsin to protein ratio. A central question in this approach is whether proteolysis with an IMER produces the same peptide cleavage products as derived from solution based digestion. The studies reported here examined this question with transferrin; a model protein of known resistance to trypsin digestion. Results from these studies confirmed that a trypsin‐IMER can in fact digest transferrin in a few minutes; providing tryptic peptides that subsequent to MS analysis allow sequence identification equivalent to solution digestion. Although many of the peptides obtained from these two trypsin digestion systems were identical, many were not. The greatest difference was that the trypsin‐ IMER produces (i) numerous peptides bearing multiple lysine and/or arginine residues and (ii) identical portions of the protein sequence were found in multiple peptides. Most of these peptides were derived from five regions in transferrin. These results were interpreted to mean that proteolysis in the case of transferrin occurred faster than the rate at which buried lysine and arginine residues were unmasked in the five regions providing peptides that were only partially digested.  相似文献   

6.
A nanoreactor based on mesoporous silicates is described for efficient tryptic digestion of proteins within the mesochannels. Cyano-functionalized mesoporous silicate (CNS), with an average pore diameter of 18 nm, is a good support for trypsin, with rapid in situ digestion of the model proteins, cytochrome c and myoglobin. The generated peptides were analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Proteolysis by trypsin-CNS is much more efficient than in-solution digestion, which can be attributed to nanoscopic confinement and concentration enrichment of the substrate within the mesopores. Proteins at concentrations of 2 ng muL(-1) were successfully identified after digestion for 20 min. A biological complex sample extracted from the cytoplasm of human liver tissue was digested by using the CNS-based reactor. Coupled with reverse-phase HPLC and MALDI-TOF MS/MS, 165 proteins were identified after standard protein data searching. This nanoreactor combines the advantages of short digestion time with retention of enzymatic activity, providing a promising way to advance the development of proteomics.  相似文献   

7.
An in-line procedure for protein analysis using a trypsin-based immobilized enzymatic reactor (IMER) coupled to LC-MS/MS has been developed. Various IMERs were synthesized and characterized by estimating the digestion yield of a pattern peptide in UV detection. Laboratory-made IMERs were optimized by studying the effect of different parameters as the nature of the functionalized immobilization support (silica, agarose), the amount of immobilized trypsin and the binding density. The potential of the laboratory-made IMERs were compared with a batch digestion and with a commercial trypsin-based IMER. The laboratory-made IMER based on CNBr-activated Sepharose showed the best performances in terms of digestion yields, digestion time, price and repeatability (RSD<4%). Cytochrome c was then digested on this IMER and used in-line with LC-MS. The target protein was easily recognized by the Mascot database until 17pmol injected.  相似文献   

8.
Zhang P  Gao M  Zhu S  Lei J  Zhang X 《Journal of chromatography. A》2011,1218(47):8567-8571
In this report, laser radiation (808nm) for the first time was employed to enhance the efficiency of proteolysis through immobilized enzyme reactor (IMER). IMER based monolithic support was prepared in the fused-silica capillary via a simple two-step procedure including acryloylation on trypsin surface and in situ aqueous polymerization/immobilization. The feasibility and high efficiency of the laser-assisted IMER were demonstrated by the digestion of bovine serum albumin (BSA), cytochrome c (Cyt-c) and β-casein. The digestion process was achieved in 60s. The peptides were identified by MALDI-TOF-MS, yielding the sequence coverage of 33% for BSA, 73% for Cyt-c and 22% for β-casein. The comparisons between the in-solution digestion and on IMER reaction with/without laser assistance were made. To further confirm its efficiency in proteome analysis, the laser-assisted IMER was also applied to the analysis of one fraction of human serum sample through two-dimensional (2-D) separation of strong anion exchange/reversed-phase liquid chromatography (SAX/RPLC). After a database search, 49 unique peptides corresponding to 5 proteins were identified. The results showed that the laser-assisted IMER provides a promising platform for the high-throughput protein identification.  相似文献   

9.
We describe an innovative approach - using a high concentration of trypsin-modified magnetic nanoparticles (TMNPs) - for the rapid and efficient digestion of proteins at elevated temperature. The required digestion time could be reduced to less than 10 s. After digestion, the TMNPs were collected magnetically from the sample solution for reuse and the digested peptides were characterized using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Protein digestion was optimized when using the TMNPs (5 microg/microL) at 57 degrees C; a significantly high peptide coverage was achieved for protein identification (e.g., 98% for lysozyme). Although a high concentration of TMNPs was used for digestion, the short digestion time led to much lower amounts of trypsin peptides being produced through self-digestion. As a result, interference in the mass spectrometric detection of the peptide ions was reduced significantly.  相似文献   

10.
周廉淇  张姣  田芳  张养军  钱小红 《色谱》2013,31(4):355-361
针对传统溶液酶解存在的酶解时间较长、酶自切物干扰以及蛋白酶不能重复使用等缺陷,通过电子转移生成催化剂的原子转移自由基聚合法修饰银丝,并以其为载体制备了一种新型的固定化酶反应器。用质谱考察了银丝固定化酶反应器(SW-Trypsin)的酶解效率、重复性和回收率。结果表明:绒毛状聚合物修饰的SW-Trypsin的酶解效率较高,酶解标准蛋白牛血清白蛋白(BSA)20 min后,肽段的氨基酸序列覆盖率可达93%,高于传统溶液酶解方法酶解16 h所得79%的覆盖率。使用该固定化酶反应器于一个月内8次酶解BSA所得的氨基酸序列覆盖率在89%到97%之间,平均覆盖率为94%,显示出良好的稳定性。另外,该固定化酶反应器酶解马心肌红蛋白(MYO)的回收率为87.67%。最后,用SW-Trypsin酶解腾冲嗜热菌全蛋白20 min,所鉴定到的氨基酸序列覆盖率和蛋白数量与同样条件下溶液酶解16 h的结果接近,且零漏切位点肽段的比例更高。加之容易分离的优点,SW-Trypsin在蛋白质组学的应用中具有良好的前景。  相似文献   

11.
A novel kind of hydrophilic monolith based immobilized enzyme reactors (IMERs) was prepared both in UV-transparent capillaries and on glass microchips by the photopolymerization of N-acryloxysuccinimide and poly(ethylene glycol)diacrylate, followed by trypsin immobilization. The performance of capillary IMERs for protein digestion was evaluated by the digestion of myoglobin with the residential time from 12s to 71 s. With μRPLC-ESI-MS/MS analysis, the obtained sequence coverages were all over 80%, comparable to that obtained by in-solution digestion for 12 h. The nonspecific absorption of BSA on monolithic support was evaluated, and no obvious protein residue was observed by a fluorescence assay. Moreover, no carry-over of the digests on the capillary IMER was found after the digestion of myoglobin (24 μg) and BSA (9 μg), which further demonstrated the good hydrophilicity of such matrix. In addition, an integrated microchip-based system involving on-line protein digestion by microchip-based IMER, peptides separation by nanoRPLC and identification by ESI-MS/MS was established, by which a mixture of standard proteins and one RPLC fraction of Escherichia coli extract were successfully identified, indicating that the hydrophilic monolith based IMER might provide a promising tool for high-throughput proteomic analysis.  相似文献   

12.
A label-free absolute quantitation method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed. This methodology was applied to mouse heart in order to quantify cardiac troponin T (cTnT), which is considered to be a sensitive marker of heart damage. The cTnT was extracted, isolated by reversed-phase high-performance liquid chromatography, digested, and analyzed by MALDI-TOF MS. The MS-based quantitation was performed using matrix-matched calibration curves (due to a matrix effect) of two synthetic peptides, one cTnT-specific peptide and one internal standard peptide, respectively. Recoveries at three spiking levels ranged from 87–96%, with relative standard deviations of below 10%. The method detection limit and the method quantitation limit, expressed as the amount of cTnT for the amount of total sarcomeric protein extract, were 0.03 mg g−1 and 0.15 mg g−1, respectively. This method appears to be accurate and generally suitable for improving absolute protein quantitation.  相似文献   

13.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was optimized to discriminate between wild-type and ampicillin-resistant Escherichia coli. Only ampicillin-resistant E. coli displayed an m/z ≈ 29,000 peak, which was confirmed as β-lactamase by in-gel digestion followed by peptide mass fingerprinting. Rapid MALDI-TOF MS detection of antibiotic-resistance could fulfill an important clinical need, providing critical phenotypic information beyond genus–species identification.  相似文献   

14.
In this study, we developed a novel microwave-assisted protein preparation and digestion method for matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry analysis and identification of proteins that involves using conductive carbon tape as a sample platform for sample preparation (reduction and alkylation) and digestion under microwave heating and as a plate for MALDI analysis. This method allows for the enzymatic digestion products of proteins to be directly analyzed by MALDI mass spectrometry and results in a marked reduction in sample loss. Our protocol requires only a small volume (1 μL) of reaction solvent, which increases the frequency of enzyme-to-protein contact, thereby resulting in more efficient digestion of sample than conventional in-solution digestion methods. To test this protocol, we used magnetic iron (II, III) oxide nanoparticles as concentrating probes to enrich phosphopeptides from a mixture of peptides in enzymatically digested protein samples. We found that the one-pot on-tape-based protein preparation and digestion under microwave heating combined with the on-tape-based enrichment method not only dramatically reduced the time required for phosphopeptides analysis but also allowed for the simultaneous identification of phosphoproteins. The advantages of our protocol include ease of use, high digestion efficiency, high specificity, and rapid (15 min) identification of proteins and enrichment of phosphopeptides in a mixture of enzymatically digested protein samples.  相似文献   

15.
A simple method to synthesize electrostatically self-assembled azides on zinc sulfide nanoparticles (ZnS-N3 NPs) was described and then it was further applied as a multifunctional nanoprobe such as enriching, desalting, accelerating and separation-/washing free nanoprobes for rapid analysis of peptides and proteins and microwave assisted tryptic digested proteins in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The ZnS-N3 NPs were characterized by UV-vis, FT-IR, SEM and TEM spectroscopy. The ZnS-N3 NPs can effectively enrich signal intensities for 2-10 times for various peptides and proteins including HW6, insulin, ubiquitin, cytochrome c, lysozyme, myoglobin and bovine serum albumin (BSA) in MALDI-TOF MS. Furthermore, we also demonstrated that the ZnS-N3 NPs can serve as accelerating probes for microwave assisted tryptic digestion of proteins in MALDI-TOF MS. The applicability of the present method on complex sample analysis such as milk proteins from cow milk and ubiquitin and ubiquitin like proteins from oyster mushroom were also demonstrated.  相似文献   

16.
Fast and effective protein digestion is a vital process for mass spectrometry (MS) based protein analysis. This study introduces a porous polymer membrane enzyme reactor (PPMER) coupled to nanoflow liquid chromatography-tandem MS (nLC-ESI-MS/MS) for on-line digestion and analysis of proteins. Poly (styrene-co-maleic anhydride) (PS-co-MAn) was fabricated by the breath figure method to make a porous polymer membrane in which the MAn group was covalently bound to enzyme. Based on this strategy, microscale PPMER (μPPMER) was constructed for on-line connection with the nLC-ESI-MS/MS system. Its capability for enzymatic digestion with bovine serum albumin (BSA) was evaluated with varied digestion periods. The on-line proteolysis of BSA and subsequent analysis with μPPMER-nLC-ESI-MS/MS revealed that peptide sequence coverage increased from 10.3% (digestion time 10 min) to 89.1% (digestion time 30 min). μPPMER can efficiently digest proteins due to the microscopic confinement effect, showing its potential application in fast protein identification and protease immobilization. Applications of on-line digestion using μPPMER with human plasma and urinary proteome samples showed that the developed on-line method yielded equivalent or better performance in protein coverage and identified more membrane proteins than the in-solution method. This may be due to easy accommodation of hydrophobic membrane proteins within membrane pores.  相似文献   

17.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

18.
The goal of this paper was to develop an in-line immobilized enzyme reactor (IMER) integrated into a capillary electrophoresis platform. In our research, we created the IMER by adsorbing trypsin onto the inner surface of a capillary in a short section. Enzyme immobilization was possible due to the electrostatic attraction between the oppositely charged fused silica capillary surface and trypsin. The reactor was formed by simply injecting and removing trypsin solution from the capillary inlet (~1–2 cms). We investigated the factors affecting the efficiency of the reactor. The main advantages of the proposed method are the fast, cheap, and easy formation of an IMER with in-line protein digestion capability. Human tear samples were used to test the efficiency of the digestion in the microreactor.  相似文献   

19.
A study was initiated to construct a micro-reactor for protein digestion based on trypsin-coated fused-silica capillaries. Initially, surface plasmon resonance was used both for optimization of the surface chemistry applied in the preparation and for monitoring the amount of enzyme that was immobilized. The highest amount of trypsin was immobilized on dextran-coated SPR surfaces which allowed the covalent coupling of 11 ng mm−2 trypsin. Fused-silica capillaries were modified in a similar manner and the resulting open-tubular trypsin-reactors having a pH optimum of pH 8.5, display a high activity when operated at 37 °C and are stable for at least two weeks when used continuously. Trypsin auto-digestion fragments, sample carry-over, and loss of signal due to adsorption of the protein were not observed. On-line digestion without prior protein denaturation, followed by micro-LC separation and photodiode array detection, was tested with horse-heart cytochrome C and horse skeletal-muscle myoglobin. The complete digestion of 20 pmol μL−1 horse cytochrome C was observed when the average residence time of the protein sample in a 140 cm ×50 μm capillary immobilized enzyme reactor (IMER) was 165 s. Mass spectrometric identification of the injected protein on the basis of the tryptic peptides proved possible. Protein digestion was favorable with respect to reaction time and fragments formed when compared with other on-line and off-line procedures. These results and the easy preparation of this micro-reactor provide possibilities for miniaturized enzyme-reactors for on-line peptide mapping and inhibitor screening.  相似文献   

20.
以微量HeLa细胞(107个)为对象, 经细胞裂解、还原羧甲基化、胰酶降解和Oasis-HLB柱提取分离得到总糖肽后, 用PNGase F酶解释放N-糖链. 对所得N-糖链用Sep-Pak C18柱纯化后进行完全甲基化衍生, 再采用基质辅助激光解吸电离-飞行时间质谱(MALDI-TOF MS)分析HeLa细胞表面N-糖链的结构轮廓. 结果表明, 在获得的34种N-糖链中, 除高甘露糖型、二天线、三天线、四天线和五天线等N-糖链外, 还出现了在某种程度上与肿瘤发生转移相关的特殊平分型和Lewis结构. 利用MALDI-TOF MS技术可快速分析微量癌细胞表面N-糖链的结构轮廓, 为进一步寻找肿瘤糖链标志物及肿瘤的早期预防诊断提供技术支持.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号