首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper focuses on the frequency analysis of acoustic signals produced by partial discharges (PDs) in insulation oil and the positioning of the PD occurrence for application in the diagnosis of oil-insulated transformers. Three types of electrode systems; the needle–plane, the plane–plane, and the wire–wire structures were assembled to simulate the partial discharge in insulation oil. A low-noise amplifier and a de-coupler were designed to detect the acoustic signal with high-sensitivity. The frequency ranges of the acoustic signal were 60–270 kHz in the needle–plane electrode system, 45–250 kHz in the plane–plane electrode system, and 50–180 kHz in the wire–wire electrode system. Their peak frequencies were 145 kHz, 118 kHz and 121 kHz, respectively.The position of the PD occurrence was calculated from the time difference of arrival (TOA) using three acoustic emission (AE) sensors. The position was found within a 1% error in the experimental set-up.  相似文献   

2.
Cavitation, chemical effect, and mechanical effect thresholds were investigated in wide frequency ranges from 22 to 4880 kHz. Each threshold was measured in terms of sound pressure at fundamental frequency. Broadband noise emitted from acoustic cavitation bubbles was detected by a hydrophone to determine the cavitation threshold. Potassium iodide oxidation caused by acoustic cavitation was used to quantify the chemical effect threshold. The ultrasonic erosion of aluminum foil was conducted to estimate the mechanical effect threshold. The cavitation, chemical effect, and mechanical effect thresholds increased with increasing frequency. The chemical effect threshold was close to the cavitation threshold for all frequencies. At low frequency below 98 kHz, the mechanical effect threshold was nearly equal to the cavitation threshold. However, the mechanical effect threshold was greatly higher than the cavitation threshold at high frequency. In addition, the thresholds of the second harmonic and the first ultraharmonic signals were measured to detect bubble occurrence. The threshold of the second harmonic approximated to the cavitation threshold below 1000 kHz. On the other hand, the threshold of the first ultraharmonic was higher than the cavitation threshold below 98 kHz and near to the cavitation threshold at high frequency.  相似文献   

3.
Acoustic cavitation energy distributions were investigated for various frequencies such as 35, 72, 110 and 170 kHz in a large-scale sonoreactor. The energy analyses were conducted in three-dimensions and the highest and most stable cavitation energy distribution was obtained not in 35 kHz but in 72 kHz. However, the half-cavitation-energy distance was larger in the case of 35 kHz ultrasound than in the case of 72 kHz, demonstrating that cavitation energy for one cycle was higher for a lower frequency. This discrepancy was due to the large surface area of the cavitation-energy-meter probe. In addition, 110 and 170 kHz ultrasound showed a very low and poor cavitation energy distribution. Therefore larger input power was required to optimize the use of higher frequency ultrasound in the sonoreactor with long-irradiation distance. The relationship between cavitation energy and sonochemical efficiency using potassium iodide (KI) dosimetry was best fitted quadratically. From 7.77 × 10?10 to 4.42 × 10?9 mol/J of sonochemical efficiency was evaluated for the cavitation energy from 31.76 to 103. 67 W. In addition, the cavitation energy attenuation was estimated under the assumption that cavitation energy measured in this study would be equivalent to sound intensity, resulting in 0.10, 0.18 and 2.44 m?1 of the attenuation coefficient (α) for 35, 72 and 110 kHz, respectively. Furthermore, α/(frequency)2 was not constant, as some previous studies have suggested.  相似文献   

4.
A resonant photoacoustic cell intended for laser-spectroscopy gas sensing is represented. This cell is a miniature imitation of a macro-scale banana-shaped cell developed previously. The parameters, which specify the cavity shape, are chosen so as not only to provide optimal cell operation at a selected acoustic resonance but also to reduce substantially the cell sizes. A miniaturized prototype cell (the volume of acoustic cavity of ∼5 mm3) adapted to the narrow diffraction-limited beam of near-infrared laser is produced and examined experimentally. The noise-associated measurement error and laser-initiated signals are studied as functions of modulation frequency. The background signal and the useful response to light absorption by the gas are analyzed in measurements of absorption for ammonia in nitrogen flow with the help of a pigtailed DFB laser diode oscillated near a wavelength of 1.53 μm. The performance of prototype operation at the second longitudinal acoustic resonance (the resonance frequency of ∼32.9 kHz, Q-factor of ∼16.3) is estimated. The noise-limited minimal detectable absorption normalized to laser-beam power and detection bandwidth is ∼8.07 × 10−8 cm−1 W Hz−1/2. The amplitude of the background signal is equivalent to an absorption coefficient of 2.51 × 10−5 cm−1. Advantages and drawbacks of the cell prototype are discussed. Despite low absorption-sensing performance, the produced miniaturized cell prototype shows a good capability of gas-leak detection.  相似文献   

5.
Ultrasonic frequencies of 20 kHz, 382 kHz, 584 kHz, 862 kHz (and 998 kHz) have been compared with regard to energy output and hydroxyl radical formation utilising the salicylic acid dosimeter. The 862 kHz frequency inputs 6 times the number of Watts into water, as measured by calorimetry, with the other frequencies having roughly the same value under very similar conditions. A plausible explanation involving acoustic fountain formation is proposed although enhanced coupling between this frequency and water cannot be discounted. Using the salicylic acid dosimeter and inputting virtually the same Wattages it is established that 862 kHz is around 10% more efficient at generating hydroxyl radicals than the 382 kHz but both of these are far more effective than the other frequencies. Also, it is found that as temperature increases to 42 °C then the total dihydroxybenzoic acid (Total DHBA) produced is virtually identical for 382 kHz and 862 kHz, though 582 kHz is substantially lower, when the power levels are set at approximately 9 W for all systems. An equivalent power level of 9 W could not be obtained for the 998 kHz transducer so a direct comparison could not be made in this instance. These results have implications for the optimum frequencies chosen for both Advanced Oxidation Processes (AOPs) and organic synthesis augmented by ultrasound.  相似文献   

6.
Lead Zirconate Titanate (PZT) is a piezo-electric ceramic material that needs to be characterized for its potential use in microelectronics. Energy dispersive X-ray analysis (EDX) is conducted to determine the chemical composition of the PZT ceramics. The scanning electron microscope (SEM) is performed to study the surface morphology, grain structure and grain boundaries. The SEM image helps us to understand the surface wave propagation and scattering phenomena by the PZT and the reason for its anisotropy and inhomogeneity due to the grain structure. In this paper scanning acoustic microscopy at 100 MHz excitation frequency is conducted for determining mechanical properties of PZT. Earlier works reported only the longitudinal wave speed in PZT while in this paper longitudinal, shear and surface acoustic wave speeds of sintered PZT are measured from its acoustic material signature (AMS) curves, also known as V(z) curves. AMS or V(z) curve is the variation of the output voltage as a function of the distance between the acoustic lens focal point and the reflecting surface. The average velocities of longitudinal, shear and surface acoustic waves in a PZT specimen are determined from its V(z) curve generated at 100 MHz excitation frequency and found to be over 5000 m/s, over 3000 m/s and between 2500 and 3000 m/s, respectively. From these velocities all elastic constants of the specimen are obtained.  相似文献   

7.
《Ultrasonics sonochemistry》2014,21(6):2176-2184
Aqueous ultrasound-assisted extraction (UAE) of grape pomace was investigated by Response Surface Methodology (RSM) to evaluate the effect of acoustic frequency (40, 80, 120 kHz), ultrasonic power density (50, 100, 150 W/L) and extraction time (5, 15, 25 min) on total phenolics, total flavonols and antioxidant capacity. All the process variables showed a significant effect on the aqueous UAE of grape pomace (p < 0.05). The Box–Behnken Design (BBD) generated satisfactory mathematical models which accurately explain the behavior of the system; allowing to predict both the extraction yield of phenolic and flavonol compounds, and also the antioxidant capacity of the grape pomace extracts. The optimal UAE conditions for all response factors were a frequency of 40 kHz, a power density of 150 W/L and 25 min of extraction time. Under these conditions, the aqueous UAE would achieve a maximum of 32.31 mg GA/100 g fw for total phenolics and 2.04 mg quercetin/100 g fw for total flavonols. Regarding the antioxidant capacity, the maximum predicted values were 53.47 and 43.66 mg Trolox/100 g fw for CUPRAC and FRAP assays, respectively. When comparing with organic UAE, in the present research, from 12% to 38% of total phenolic bibliographic values were obtained, but using only water as the extraction solvent, and applying lower temperatures and shorter extraction times. To the best of the authors’ knowledge, no studies specifically addressing the optimization of both acoustic frequency and power density during aqueous-UAE of plant materials have been previously published.  相似文献   

8.
An Sun  Zhishen Wu  Chunfeng Wan  Caiqian Yang 《Optik》2012,123(13):1138-1139
A simple and low cost optical fiber acoustic sensor based on multimode-single mode-multimode (MSM) fiber structure is presented. The optical coupling efficiency between hetero-core fibers spliced structure is modulated by acoustic pressure through a thin metal foil. Acoustic wave is detected by measuring the intensity change of transmission light. Experiments are carried on to testify the performance of MSM fiber acoustic sensor and the experimental results show that the acoustic wave can be sensitively detected within 11 kHz frequency range.  相似文献   

9.
《Ultrasonics》2013,53(1):249-254
It has recently been demonstrated that it was possible to individually trap 70 μm droplets flowing within a 500 μm wide microfluidic channel by a 24 MHz single element piezo-composite focused transducer. In order to further develop this non-invasive approach as a microfluidic particle manipulation tool of high precision, the trapping force needs to be calibrated to a known force, i.e., viscous drag force arising from the fluid flow in the channel. However, few calibration studies based on fluid viscosity have been carried out with focused acoustic beams for moving objects in microfluidic environments.In this paper, the acoustic trapping force (Ftrapping) and the trap stiffness (or compliance k) are experimentally determined for a streaming droplet in a microfluidic channel. Ftrapping is calibrated to viscous drag force produced from syringe pumps. Chebyshev-windowed chirp coded excitation sequences sweeping the frequency range from 18 MHz to 30 MHz is utilized to drive the transducer, enabling the beam transmission through the channel/fluid interface for interrogating the droplets inside the channel. The minimum force (Fmin,trapping) required for initially immobilizing drifting droplets is determined as a function of pulse repetition frequency (PRF), duty factor (DTF), and input voltage amplitude (Vin) to the transducer. At PRF = 0.1 kHz and DTF = 30%, Fmin,trapping is increased from 2.2 nN for Vin = 22 Vpp to 3.8 nN for Vin = 54 Vpp. With a fixed Vin = 54 Vpp and DTF = 30%, Fmin,trapping can be varied from 3.8 nN at PRF = 0.1 kHz to 6.7 nN at PRF = 0.5 kHz. These findings indicate that both higher driving voltage and more frequent beam transmission yield stronger traps for holding droplets in motion.The stiffness k can be estimated through linear regression by measuring the trapping force (Ftrapping) corresponding to the displacement (x) of a droplet from the trap center. By plotting Ftrappingx curves for certain values of Vin (22/38/54 Vpp) at DTF = 10% and PRF = 0.1 kHz, k is measured to be 0.09, 0.14, and 0.20 nN/μm, respectively. With variable PRF from 0.1 to 0.5 kHz at Vin = 54 Vpp, k is increased from 0.20 to 0.42 nN/μm. It is shown that a higher PRF leads to a more compliant trap formation (or a stronger Ftrapping) for a given displacement x. Hence the results suggest that this acoustic trapping method has the potential as a noninvasive manipulation tool for individual moving targets in microfluidics by adjusting the transducer’s excitation parameters.  相似文献   

10.
We here suggest a novel and straightforward approach for liter-scale ultrasound particle manipulation standing wave systems to guide system design in terms of frequency and acoustic power for operating in either cavitation or non-cavitation regimes for ultrasound standing wave systems, using the sonochemiluminescent chemical luminol. We show that this method offers a simple way of in situ determination of the cavitation threshold for selected separation vessel geometry. Since the pressure field is system specific the cavitation threshold is system specific (for the threshold parameter range). In this study we discuss cavitation effects and also measure one implication of cavitation for the application of milk fat separation, the degree of milk fat lipid oxidation by headspace volatile measurements. For the evaluated vessel, 2 MHz as opposed to 1 MHz operation enabled operation in non-cavitation or low cavitation conditions as measured by the luminol intensity threshold method. In all cases the lipid oxidation derived volatiles were below the human sensory detection level. Ultrasound treatment did not significantly influence the oxidative changes in milk for either 1 MHz (dose of 46 kJ/L and 464 kJ/L) or 2 MHz (dose of 37 kJ/L and 373 kJ/L) operation.  相似文献   

11.
Artificial ear is being used to evaluate the acoustic response and the sound quality of the mobile telephony devices, which simulates the practical listening condition of the outer ears. In this paper, a method to estimate the coupled acoustic response of the device with an artificial ear is studied to be effectively used in the design. To this end, an equivalent circuit model of the total receiver system including all accessory elements is established. Acoustic impedance of artificial ear, which is essential in the equivalent model, is directly measured by using three microphones arranged in tandem on the duct wall connected to the artificial ear. Input impedances of two artificial ears, Type 3.3 and 3.4, which are currently employed as the standard devices, are measured. The measured data is incorporated into the model to predict the acoustic response. To validate the proposed model using the measured impedance, the measured acoustic responses of two simulation systems including mobile phone and artificial ear are compared with the predicted ones. A reasonably good agreement between measurement and prediction is observed, and their difference is less than 4.5 dB at the narrow communication band for a mobile phone (f < 3.4 kHz). It is also found that the input impedance of Type 3.3 ear is more robust to the change of measuring condition than Type 3.4 ear.  相似文献   

12.
The motion of a single water droplet in oil under ultrasonic irradiation is investigated with high-speed photography in this paper. First, we described the trajectory of water droplet in oil under ultrasonic irradiation. Results indicate that in acoustic field the motion of water droplet subjected to intermittent positive and negative ultrasonic pressure shows obvious quasi-sinusoidal oscillation. Afterwards, the influence of major parameters on the motion characteristics of water droplet was studied, such as acoustic intensity, ultrasonic frequency, continuous phase viscosity, interfacial tension, and droplet diameter, etc. It is found that when the acoustic intensity and frequency are 4.89 W cm−2 and 20 kHz respectively, which are the critical conditions, the droplet varying from 250 to 300 μm in lower viscous oil has the largest oscillation amplitude and highest oscillation frequency.  相似文献   

13.
An accelerometer-based underwater acoustic intensity vector sensor is used to measure the acoustic nearfield of a single spherical source, and a pair of sources that vibrate in or out of phase with each other. The intensity sensor consists of co-located pressure and inertial sensors within a neutrally buoyant probe body. The design of this probe has been published previously. The measurements were performed in a large tank at a frequency of 5 kHz for two sources of different sizes, corresponding to ka values of 0.7 and 1.2 respectively, where k is acoustic wavenumber and a is the source radius. By way of validation, the acoustic intensity field from two closely spaced, interacting spherical radiators is predicted using the exact theory of the translational addition theorem for spherical wave functions. The predictions using this theory compare favorably well with the measured intensity field. Beam pattern and calibration data obtained for the intensity sensor suggest that underwater acoustic intensity generated by simple and complex sources can be measured to an accuracy of ±1 dB provided that ka is less than approximately 0.2.  相似文献   

14.
This paper shows a systematic study of the 500 kHz frequency ultrasound efficiency on the microbial inactivation as a function of ultrasonic power delivered into the bacterial suspension. The inactivation of Escherichia coli IAM 12058, a Gram-negative bacterium and Streptococcus mutans JCM 5175, a Gram-positive bacterium is enhanced by increasing the ultrasonic power in the range of 1.7–12.4 W and the logarithm of survival ratio decreases linearly with irradiation time, except for E. coli sonicated with the highest power level. The rate constants were estimated in the linear region of the plots representing survival ratio logarithm vs. sonication time. A better understanding of the inactivation process at 500 kHz could be gained by suppressing the chemical effects with a radical scavenger. We find out that the rate constants increase with the ultrasonic power delivered into the solution and dramatically decrease by the addition of t-butanol as a radical scavenger to the bacterial suspension. For comparison, experiments were carried out at a low frequency level of 20 kHz. It was found out that for the same ultrasonic power delivered into the bacterial suspension, the inactivation was slightly enhanced at 500 kHz frequency. The examinations of bacterium performed with a TEM revealed lethal damages arising from the interaction of bacterial cells with the cavitational bubbles. A significant amount of empty cell envelopes as well as their cytoplasmatic content was detected. Thus, based on these new data, the mechanism of bacterial inactivation by ultrasounds at high frequency is discussed here.  相似文献   

15.
The aim of this study was to compare different characterization methods in order to evaluate the sonochemical efficiency of a cavitational reactor. The selected characterization methods were calorimetry and dosimetry based on potassium iodide oxidation or nitrite and nitrate ion formation. The effects of experimental parameters on physical and chemical effects of ultrasound were quantified with two transducers at a frequency of 366 kHz. The studied factors comprised temperature (16–28 °C), acoustic power (6–38 W), power density (4–61 W L?1) and reactor configuration (Dreactor 1 = 65 mm, Dreactor 2 = 102 mm). Spectrophotometry was compared to ionic chromatography as a method to quantify nitrite and nitrate ions. Spectrometry was shown to be as representative as ionic chromatography. The reaction system based on the formation of both nitrite and nitrate ions was demonstrated to be as reliable as a potassium iodide dosimeter. The representativity of calorimetry was limited since part of acoustic energy was assumed to be used in the chemical reactions observed by dosimetry. Similar sonochemical efficiencies resulted from an increase of sonified surface (Dreactor 1 = 65 mm vs. Dreactor 2 = 102 mm) coupled to a 2-time decrease in power density at a constant emitting surface. The effect of emitting-to-sonified surface area ratio on the acoustic field was apparently limited by the height of the liquid.  相似文献   

16.
《Ultrasonics》2014,54(1):296-304
This paper investigates a new method for fabrication of broadband line-focus ultrasonic transducers by sol–gel spin-coating the poly(vinylidene difluoride-trifluroethylene) [P(VDF-TrFE)] copolymer film on a concave fine-polished beryllium copper backing. The ferroelectric hysteresis loops of the P(VDF-TrFE) films spin-coated from different molar ratios of VDF/TrFE, 77/23 and 55/45, were measured to select the better mixture. Owing to the better acoustic matching to water, compared with lead zirconate titanate (PZT), the fabricated transducers show relatively wide bandwidth of approximately 50 MHz with high central frequency of 60 MHz obtained at the focal plane when a fused-quartz acts as a reflecting target. Each one of the two finished transducers has a focal length of 5 mm and a full aperture angle of 90°. After applying the specially developed digital signal processing algorithm to the defocusing experiment data, which is called V(f,z) analysis method based on two-dimensional fast Fourier transform (2-D FFT), the operating frequency can extend from several MHz to over 90 MHz. Surface acoustic wave (SAW) velocities of a typical (1 0 0) silicon wafer was measured along various directions between [1 0 0] and [0 1 0] to represent the anisotropic features.  相似文献   

17.
Currently several therapeutic applications of ultrasound in cancer treatment are under progress which uses cavitation phenomena to deliver their effects. There are several methods to evaluate cavitation activity such as chemical dosimetry and measurement of subharmonic signals. In this study, the cavitation activity induced by the ultrasound irradiation on exposure parameters has been measured by terephthalic acid chemical dosimetry and subharmonic analysis. Experiments were performed in the near 1 MHz fields in the progressive wave mode and effect of duty cycles changes with 2 W/cm2 intensity (ISATA) and acoustic intensity changes in continuous mode on both fluorescence intensity and subharmonic intensity were measured. The dependence between fluorescence intensity of terephthalic acid chemical dosimetry and subharmonic intensity analysis were analyzed by Pearson correlation (p-value < 0.05). It has been shown that the subharmonic intensity and the fluorescence intensity for continuous mode is higher than for pulsing mode (p-value < 0.05). Also results show that there is a significant difference between the subharmonic intensity and the fluorescence intensity with sonication intensity (p-value < 0.05). A significant correlation between the fluorescence intensity and subharmonic intensity at different duty cycles (R = 0.997, p-value < 0.05) and different intensities (R = 0.985, p-value < 0.05) were shown. The subharmonic intensity (μW/cm2) significantly correlated with the fluorescence intensity (count) (R = 0.901; p < 0.05) and the fluorescence intensity due to chemical dosimetry could be estimated with subharmonic intensity due to subharmonic spectrum analysis. It is concluded that there is dependence between terephthalic acid chemical dosimetry and subharmonic spectrum analysis to examine the acoustic cavitation activity.  相似文献   

18.
Knowledge of the kinetics of gas bubble formation and evolution under cavitation conditions in molten alloys is important for the control casting defects such as porosity and dissolved hydrogen. Using in situ synchrotron X-ray radiography, we studied the dynamic behaviour of ultrasonic cavitation gas bubbles in a molten Al–10 wt% Cu alloy. The size distribution, average radius and growth rate of cavitation gas bubbles were quantified under an acoustic intensity of 800 W/cm2 and a maximum acoustic pressure of 4.5 MPa (45 atm). Bubbles exhibited a log-normal size distribution with an average radius of 15.3 ± 0.5 μm. Under applied sonication conditions the growth rate of bubble radius, R(t), followed a power law with a form of R(t) = αtβ, and α = 0.0021 & β = 0.89. The observed tendencies were discussed in relation to bubble growth mechanisms of Al alloy melts.  相似文献   

19.
《Current Applied Physics》2010,10(2):381-385
This paper described a method for estimating the acoustic characteristics of composite materials at oblique incidence of sound waves. Composite materials are used as acoustic windows of SONAR to protect the internal sensors and electronic parts from water. In this study the composite material of glass reinforced plastic and polyurethane was used as the specimen. As the acoustic characteristics the velocities and attenuation coefficients of sound waves through the composite material were measured in the high frequency range. The insertion loss was also measured as a function of incident angle at 200 and 76 kHz, respectively. The attenuation coefficients in the low frequency range were estimated by interpolating the measured attenuation in the high frequency range with power-law form fitting. A four-medium layer model was proposed to estimate the insertion loss of composite materials at oblique incidence of sound waves in the low frequency range. The four-medium layer model well described the experimentally measured insertion loss at the high frequency range. It suggests that the insertion loss of the composite materials can be well estimated as a function of incident angle in the low frequency range.  相似文献   

20.
In this work, a comparison between the temperatures/pressures within acoustic cavitation bubble in an imidazolium-based room-temperature ionic liquid (RTIL), 1-butyl-3-methylimidazolium bis(triflluoromethyl-sulfonyl)imide ([BMIM][NTf2]), and in water has been made for a wide range of cavitation parameters including frequency (140–1000 kHz), acoustic intensity (0.5–1 W cm−2), liquid temperature (20–50 °C) and external static pressure (0.7–1.5 atm). The used cavitation model takes into account the liquid compressibility as well as the surface tension and the viscosity of the medium. It was found that the bubble temperatures and pressures were always much higher in the ionic liquid compared to those predicted in water. The valuable effect of [BMIM][NTf2] on the bubble temperature was more pronounced at higher acoustic intensity and liquid temperature and lower frequency and external static pressure. However, confrontation between the predicted and the experimental estimated temperatures in ionic liquids showed an opposite trend as the temperatures measured in some pure ionic liquids are of the same order as those observed in water. The injection of liquid droplets into cavitation bubbles, the pyrolysis of ionic liquids at the bubble-solution interface as well as the lower number of collapsing bubbles in the ionic liquid may be the responsible for the lower measured bubble temperatures in ionic liquids, as compared with water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏