首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 693 毫秒
1.
A method for the determination of sterols in vegetable oils by CEC with UV–Vis detection, using methacrylate ester‐based monolithic columns, has been developed. To prepare the columns, polymerization mixtures containing monomers of different hydrophobicities were tried. The influence of composition of polymerization mixture was optimized in terms of porogenic solvent, monomers/porogens and monomer/crosslinker ratios. The composition of the mobile phase was also studied. The optimum monolith was obtained with lauryl methacrylate monomer at 60:40% (wt:wt) lauryl methacrylate/ethylene dimethacrylate ratio and 60 wt% porogens with 20 wt% of 1,4‐butanediol (12 wt% 1,4‐butanediol in the polymerization mixture). Excellent resolution between sterols was achieved in less than 7 min with an 85:10:5 v/v/v ACN–2‐propanol–water buffer containing 5 mM Tris at pH 8.0. The limits of detection were lower than 0.04 mM, and inter‐day and column‐to‐column reproducibilities at 0.75 mM were better than 6.2%. The method was applied to the determination of sterols in vegetable oils with different botanical origins and to detect olive oil adulteration with sunflower and soybean oils.  相似文献   

2.
The separation and determination of tocopherols (Ts) in vegetable oils by CEC using methacrylate ester-based monolithic columns has been developed. The effects of pore size of the monolithic columns were studied, and the composition of mobile phase was optimized. The optimal pore size of the monolith was obtained with 12 wt% 1,4-butanediol in the polymerization mixture. Excellent resolution between tocopherols was achieved within 10 min analysis time with a 99:1 v/v MeOH-aqueous buffer containing 5 mM tris(hydroxymethyl)aminomethane at pH 8.0. The LODs were lower than 2.3 microg/mL, and interday and column-to-column reproducibilities at 25 microg/mL were better than 5.6%. Using a 93:7 v/v MeOH-aqueous buffer, both tocopherols and tocotrienols (T(3)s) of grapeseed and palm oils were resolved. Application to the detection of olive oil adulteration with low-cost edible oils was demonstrated.  相似文献   

3.
王婷婷  梁振  张丽华  张玉奎 《色谱》2010,28(3):236-239
以十二烷基甲基丙烯酸酯(LMA)为功能单体,乙叉二甲基丙烯酸酯(EDMA)为交联剂,正丙醇、1,4-丁二醇和水为三元致孔剂,以及2-丙烯酰胺-2-甲基丙磺酸(AMPS)为电渗流产生剂,制备了聚十二烷基甲基丙烯酸酯整体柱。系统考察了AMPS含量和单体-致孔剂比例对柱性能的影响。结果表明,单体溶液和致孔剂的最佳聚合溶液质量比为35:65,其中单体溶液组成为59.5%(质量分数,下同)LMA、40%EDMA和0.5%AMPS,致孔剂溶液组成为60%正丙醇、30%1,4-丁二醇和10%水。在优化的流动相条件下应用制备的整体柱采用毛细管电色谱法成功地分离了肌红蛋白酶解产物。  相似文献   

4.
Butyl methacrylate monolithic columns in 320 microm i.d. fused silica capillaries for reversed-phase capillary liquid chromatography were prepared by radical polymerization initiated thermally with azobisisobutyronitrile (AIBN). Polymerization mixture contained butyl methacrylate (BMA) as the function monomer and ethylene dimethacrylate (EDMA) as the crosslinking agent with 1,4-butanediol and 1-propanol as a binary porogen solvent. Ratio of 1,4-butanediol to 1-propanol in the porogen solvent was optimized regarding the monolithic column efficiency and performance. Total porosity, column permeability, separation impedance, Walters hydrophobicity index, retention factors, peak asymmetry factors, height equivalents to a theoretical plate and peak resolutions were used for characterization of the prepared monolithic columns. The polymerization mixture consisting of 17.8% of BMA, 21.8% of EDMA, 18.0% of 1,4-butanediol, 42.0% of 1-propanol and 0.4% AIBN generated monolithic columns of the best performance having a sufficient permeability and the lowest separation impedance. It was also demonstrated that monolithic columns of this composition exhibited good preparation reproducibility and an excellent pressure resistance when applied in capillary liquid chromatography.  相似文献   

5.
The main factors affecting the porosity of methacrylate-ester based monolithic columns were investigated. We prepared 23 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate and ethylene dimethacrylate monomers and of 1,4-butanediol and 1-propanol as the porogen solvent in the polymerization mixtures by thermally initiated in-situ polymerization in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting flow-through pore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the flow-through porosity in monolithic beds as a function of the composition of the polymerization mixture used to prepare polymethacrylate monolithic capillary columns. The mean error of prediction was lower than 8% for eight columns prepared independently of the original set of 15 columns used to derive the flow-through model. The flow-through porosity increases with increasing concentration of the binary porogen solvent mixture, the concentration of 1,4-butanediol being the main factor enhancing flow-through pore formation. On the other hand, increasing concentrations of the hydrophobic monomer butyl methacrylate and increasing concentrations of 1-propanol have a negative effect on flow-through pore formation. The capillary columns prepared with a high proportion of flow-through pores and a minimum amount of mesopores can be used for fast gradient separations of both low-molecular weight compounds and biopolymers.  相似文献   

6.
Yu C  Svec F  Fréchet JM 《Electrophoresis》2000,21(1):120-127
Photoinitiated free radical polymerization has been used for the preparation of porous polymer monoliths within UV transparent fused silica capillaries and quartz tubes. These formats were used as models for the preparation of the separation media within channels of microfabricated devices. A mixture of ethylene dimethacrylate, butyl methacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid was polymerized in the presence of a porogenic solvent consisting of 1-propanol, 1,4-butanediol, and water at room temperature under UV irradiation. Modification of the porogen composition enables the tailoring of pore size within the broad range from ca. 100 to 4000 nm. Scanning electron micrographs confirmed the homogeneity of the porous structure of the materials prepared, even in a quartz tube with a diameter as large as 4 mm. Separation properties of the resulting capillary columns were tested in capillary electrochromatography (CEC) mode using a mixture of thiourea and eight aromatic compounds. Plate number as high as 210 000 plates/m were found for a capillary column with optimized porous properties. The monolithic columns were also able to separate mixtures of peptides.  相似文献   

7.
The separation of hydroxyaromatic compounds in vegetable oils, including synthetic antioxidants (3-tert-butyl-4-hydroxyanisol and 2,6-di-tert-butyl-4-hydroxytoluene), E-vitamers and other natural oil components, by nonaqueous capillary electrophoresis in an oil-miscible background electrolyte (BGE) was investigated. The BGE contained 40 mM KOH in a methanol/1-propanol (PrOH) mixture (15:85 v/v). The oil samples were 1:1 diluted with PrOH and directly injected in the capillary. Under negative polarity (cathode at the injection end), the anionic solutes moved faster than the electroosmotic flow, being well-resolved among them and from the triacylglycerols. Using virgin palm, extra virgin olive, wheat germ, virgin soybean and other oils, the capability of the procedure to quickly yield a characteristic profile of the biophenols present in the sample was demonstrated. The alpha-, (beta + gamma)- (as unresolved pair) and delta-tocopherols of a soybean oil sample were quantified.  相似文献   

8.
胃蛋白酶亲和有机聚合物毛细管整体柱的制备及性能考察   总被引:1,自引:0,他引:1  
池翠杰  王伟  季一兵 《色谱》2014,32(8):791-797
以热引发原位聚合方法制备了聚(甲基丙烯酸缩水甘油酯(glycidyl methacrylate,GMA)-乙二醇二甲基丙烯酸酯(ethyleneglycol dimethacrylate,EDMA))毛细管整体柱,对整体柱的性能进行了表征。结果表明,柱内部结构均匀、渗透性好;整体柱能够实现苯等中性小分子化合物的分离,具有反相色谱特征,重现性和稳定性良好。利用整体柱环氧基团的活性,采用间接法,以戊二醛为连接臂制备胃蛋白酶亲和手性整体柱。在毛细管电色谱模式下进行了柱分离性能研究,并对缓冲液pH值和运行电压等分离条件进行了考察。结果表明,亲和整体柱对4种碱性手性药物(奈福泮、氨氯地平、西酞普兰、扑尔敏)有拆分效果,奈福泮、氨氯地平、西酞普兰能达到基线分离。本文为蛋白质亲和毛细管电色谱整体柱的制备和应用提供了新的思路和方法。  相似文献   

9.
A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA–EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase.  相似文献   

10.
Two methacrylate-based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N-dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1-propanol and 1,4-butanediol. The performance of this column was evaluated by means of the analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30,000 and a good resolution between closely related peaks. The 2-acrylamido-2-methyl-1-propane-sulfonic acid column was used for CEC-MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.  相似文献   

11.
Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.  相似文献   

12.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable.  相似文献   

13.
The preparation of polymeric monoliths with embedded carboxy-modified single-walled carbon nanotubes (c-SWNTs) and their use for capillary electrochromatography (CEC) is described. Carbon nanotube composites were obtained by preparing a polymerization mixture in the presence of increasing c-SWNT concentrations, followed by UV initiation. The novel stationary phases were studied by optical microscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. Using short UV-polymerization times, the optimized porogenic solvent (a binary mixture of 1,4-butanediol and 2-propanol) gave rise to polymeric beds with homogenously dispersed embedded c-SWNTs. The CEC features of these monoliths were evaluated using polycyclic aromatic hydrocarbons (PAHs), non-steroidal anti-inflammatory drugs (NSAIDs) and chiral compounds. The monolith prepared in the presence of c-SWNTs showed enhanced resolution of the text mixtures, including a remarkable capability to separate enantiomers. Graphical Abstract
UV-polymerized polymeric monoliths with embedded c-SWNTs for CEC applications  相似文献   

14.
A rapid capillary electrochromatographic (CEC) method for the analysis of vitamin E in vegetable oils is reported. Vitamin E consists of a group of eight isomers, tocopherols (TOHs) and tocotrienols. The separation of four TOHs (alpha-, gamma-, delta-TOH), alpha-tocopherol acetate (alpha-TOH-Ac), and an antioxidant compound, butylated hydroxytoluene (BHT) used to prevent TOH autoxidation, was optimized. The CEC experiments were carried out in a 75 microm inner diameter (ID) fused-silica capillary, partially packed with 3 microm C(18 )stationary phase (33 cm total length, 8.4 cm and 7 cm effective and packed lengths, respectively). The optimum mobile phase was a polar organic phase composed of a mixture of methanol-acetonitrile in the ratio 50/50 v/v containing 0.01% ammonium acetate, applying a voltage and temperature set at -25 kV and 20 degrees C, respectively. The tocopherols and the BHT were successfully separated within 2.5 min using the short-end injection method. Under these experimental conditions, repeatability of retention time and peak area, analyte detection and quantitation limits, linearity, precision, and accuracy were studied. The CEC method was applied to determine the content of TOHs in different commercially available oils of virgin olive, hazelnut, sunflower, and soybean. The extraction of vitamin E isomers from oil samples was achieved using methanol and a methanol-isopropanol mixture.  相似文献   

15.
The ability of reversed-phase high-performance liquid chromatography (RP-HPLC) to separate some positionally isomeric disaturated and monounsaturated triacylglycerols (TAGs) as intact species is demonstrated for the first time. Mobile phases of acetonitrile modified with methanol, ethanol, 2-propanol, 1-propanol, 1-butanol, acetone, or dichloromethane were tested for the separation of POP-PPO, PLP-PPL, PEP-PPE, and PDP-PPD (P-palmitic, O-oleic, L-linoleic, E-eicosapentaenoic, D-docosahexaenoic acid residue) on a single RP-HPLC column. The resolution improved with increasing number of double bonds in the acyl residues. While POP and PPO were only partially resolved, PDP and PPD were fully separated with all tested mobile phases, except those containing methanol. Also separated were the four TAGs having the same equivalent carbon number (ECN = 42), PEP, PPE, PDP, and PPD, on a single RP-HPLC column with mobile phase acetonitrile-2-propanol (70:30, v/v) at 0.8 mL/min. In all cases the isomer with the unsaturated acyl residue in either 1- or 3-position was retained more strongly than the respective 2-isomer.  相似文献   

16.
The main factors affecting the mesopore porosity of methacrylate-ester based monolithic columns were investigated. We prepared 40 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate (BMA) and ethylene dimethacrylate (EDMA) monomers and of 1,4-butanediol (BUT) and 1-propanol (PROP) as the porogen solvent in the polymerisation mixtures by thermally initiated in situ polymerisation in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting mesopore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the mesopore porosity in monolithic beds as a function of the composition of the polymerisation mixture used to prepare polymethacrylate monolithic capillary columns. The mean absolute deviation of predicted porosities is 0.029 for most of the columns, with only eight columns showing deviations exceeding 0.050. The main factor affecting the mesopore porosity proved to be the combination of the concentration of hydrophobic monomer (BMA) and the concentration of the less-polar solvent, 1-propanol, in the porogen mixture. The proportion of mesopores in the monolithic capillary columns increases with increasing concentration of 1-propanol and with decreasing concentration ratios of the cross-linker (EDMA) to monomer (BMA) and of BUT to PROP porogenic solvents.  相似文献   

17.
The in situ preparation of monolithic capillary columns comprising copolymers of butyl methacrylate with ethylene dimethacrylate, diethylene glycol dimethacrylate, triethylene glycol dimethacrylate, and pentaerythritol tetraacrylate using thermal polymerization within 250 microm ID capillaries and their application for micro-HPLC separations of proteins has been studied. For all crosslinkers, optimization of the porogenic mixture consisting of 1-propanol and 1,4-butanediol yielded monoliths with pore sizes above 1 microm suitable for rapid separations at low back pressure. Very good separations were achieved for a protein mixture consisting of ribonuclease A, cytochrome c, myoglobin, and ovalbumin with all tested columns.  相似文献   

18.
Hemp seed by-products, namely hemp cake (hemp meal) and hemp hulls were studied for their lipid content and composition. Total lipid content of hemp cake and hemp hulls was 13.1% and 17.5%, respectively. Oil extraction yields using hexane, on the other hand, were much lower in hemp cake (7.4%) and hemp hulls (12.1%). Oil derived from both hemp seeds and by-products were primarily composed of neutral lipids (>97.1%), mainly triacylglycerols (TAGs), determined by SPE and confirmed by NMR study. Linoleic acid was the major fatty acid present in oils derived from hemp by-products, covering almost 55%, followed by α-linolenic acid, covering around 18% of the total fatty acids. For the first time, 47 intact TAGs were identified in the hemp oils using UPLC-HRMS. Among them, TAGs with fatty acid acyl chain 18:3/18:2/18:2 and 18:3/18:2/18:1 were the major ones, followed by TAGs with fatty acid acyl chain of 18:3/18:3/18:2, 18:2/18:2/16:0, 18:2/18:2/18:1, 18:3/18:2.18:0, 18:2/18:2/18:0, 18:2/18:1/18:1 and 18:3/18:2:16:0. Besides TAGs, low levels of terpenes, carotenoids and cannabidiolic acid were also detected in the oils. Moreover, the oils extracted from hemp by-products possessed a dose-dependent DPPH radical scavenging property and their potencies were in a similar range compared to other vegetable oils.  相似文献   

19.
Maíra Fasciotti 《Talanta》2010,81(3):1116-4951
Triacylglycerols (TAGs) are the main constituents of vegetable oils where they occur in complex mixtures with characteristic distributions. Mass spectrometry using an atmospheric pressure chemical ionization interface (APCI-MS) run in positive mode and an Ion Trap mass analyser were applied in the study of olive and soybean oils and their mixtures. Direct injections of soybean and olive oil solutions allowed the identification of ions derived from the main TAGs of both oils. This procedure showed to be a simple and powerful tool to evaluate mixtures or addition of soybean to olive oil. TAG separation was optimized by high performance liquid chromatography (HPLC) using an octadecylsilica LiChrospher column (250 mm × 3 mm; 5 μm) and a gradient composed of acetonitrile and 2-propanol allowed the separation of the main TAGs of the studied oils. APCI vaporization temperature was optimized and best signals were obtained at 370 °C. Multiple reaction monitoring (MRM) employing the transition of the protonated TAG molecules ([M+H]+) to the protonated diacylglycerol fragments ([M+H−R]+) improved the selectivity of TAG detection and was used in quantitative studies. Different strategies were developed to evaluate oil composition following TAG analysis by MRM. The external standard calibration and standard additions methods were compared for triolein quantification but the former showed to be biased. Further quantitative studies were based on the estimates of soybean and olive oil proportions in mixtures by comparison of TAG areas found in mixtures of known and unknown composition of both oils. Good agreement with expected or labeled values was found for a commercial blend containing 15% (w/w) of olive oil in soybean oil and to a 1:1 mixture of both oils, showing the potential of this method in characterizing oil mixtures and estimating oil proportions. Olive oils of different origins were also evaluated by mass spectra data obtained after direct injections of oil solutions and principal component analysis (PCA). Argentinean olive oils were clustered in a different area of the principal components plot (PC2 × PC1) in comparison with European olive oils. The commercial blend containing 15% (w/w) of olive oil in soybean oil appeared in a completely different area of the graphic, showing the potential of this method to screen out for olive oil adulterations.  相似文献   

20.
Lauryl methacrylate (LMA)‐ester based monolithic columns photo‐polymerized using lauroyl peroxide (LPO) as initiator were prepared, and their morphological and CEC properties were studied. The composition of the polymerization mixture (i.e. ratios of monomers/porogenic solvents, 1,4‐butanediol/1‐propanol and LMA/crosslinker) was optimized. The morphological and chromatographic properties of LMA columns were evaluated by means of SEM pictures and van Deemter plots of PAHs, respectively. The polymerization mixture selected as optimal provided a fast separation of a mixture of PAHs with excellent efficiencies (minimum plate heights of 8.9–11.1 μm). Satisfactory column‐to‐column (RSD<4.5%) and batch‐to‐batch reproducibilities (RSD<6.3%) were achieved. The LMA columns photo‐polymerized with LPO were compared with those prepared with AIBN. Using PAHs, alkylbenzenes and basic compounds for testing, the columns obtained with LPO gave the best compromise between efficiency, resolution and analysis time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号