首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 653 毫秒
1.
The objective of this research was to test suitability of the Dumas combustion method to completely substitute the Kjeldahl method in routine laboratory determination of crude protein content in cereals and oilseeds. The validation of the method demonstrated that it is able to determine crude protein content in cereals and oilseeds in an efficient and accurate manner, with a detection limit w(N) = 0.006%, quantification limit w(N) = 0.019%, repeatability precision RSD r = 0.41%, intra-laboratory reproducibility precision RSD R = 0.74%, trueness, expressed in terms of bias b = 0.43%, and linear response between (2.36–19.2) mg N. Measurement uncertainty, expressed as relative expanded uncertainty (coverage factor k = 2, confidence level 95%), was calculated from validation data (U rel = 2.24%). In order to examine the relationship between two methods, 15 cereal grain and oilseed samples were analyzed using Dumas and Kjeldahl procedure. The Kjeldahl procedure gave slightly lower w(N) values than the Dumas procedure: w K(N) = 0.9905 w D(N) = 0.0376 (R 2  = 0.9996). Relative standard deviations and results of homogeneity test obtained during analysis of complex cereal products (cereal breakfast and muesli bars) show that the Dumas combustion method may be less suitable for analysis of such samples compared to Kjeldahl method.  相似文献   

2.
Thompson M  Owen L  Wilkinson K  Wood R  Damant A 《The Analyst》2002,127(12):1666-1668
Both the Kjeldahl and the Dumas methods for the determination of protein in foodstuffs are currently in use, but the empirical nitrogen factors used to convert the determined nitrogen content to protein content are based on the Kjeldahl method alone. Non-equivalence between the two methods could therefore result in some laboratories reporting an incorrect protein content. We report here a study using data accumulated over several years in the results of a proficiency testing scheme. On average the Dumas method provided results that were relatively higher by about 1.4% than the Kjeldahl method, but the difference between the methods depended on the type of foodstuff. The methodology of looking for bias between analytical methods is critically discussed.  相似文献   

3.
Marcó A  Rubio R  Compañó R  Casals I 《Talanta》2002,57(5):1019-1026
The features of the Dumas combustion method (CM) and those of the Kjeldahl method (KM) were compared as they apply to total nitrogen determination in animal feed. Both methods achieved similar repeatability (S.D., 0.11-0.38 from Kjeldahl and 0.15-0.36 from combustion) and similar intra-laboratory reproducibility (S.D., 0.11-0.39 from Kjeldahl and 0.15-0.37 from combustion). R.S.D. is always below 2%. These results show that the CM is suitable for the analysis of protein content in animal feed (5-75% protein content). The CM is recommended owing to its shorter analysis time, its cost and its environmental suitability.  相似文献   

4.
The total Kjeldahl nitrogen (TKN) method was simplified by using a manifold connected to a purge-and-trap system immersed into an ultrasonic (US) bath for simultaneous ammonia (NH3) extraction from many previously digested samples. Then, ammonia was collected in an acidic solution, converted to ammonium (NH4+), and finally determined by ion chromatography method. Some variables were optimized, such as ultrasonic irradiation power and frequency, ultrasound-assisted NH3 extraction time, NH4+ mass and sulfuric acid concentration added to the NH3 collector flask. Recovery tests revealed no changes in the pH values and no conversion of NH4+ into other nitrogen species during the irradiation of NH4Cl solutions with 25 or 40 kHz ultrasonic waves for up to 20 min. Sediment and oil free sandstone samples and soil certified reference materials (NCS DC 73319, NCS DC 73321 and NCS DC 73326) with different total nitrogen concentrations were analysed. The proposed method is faster, simpler and more sensitive than the classical Kjeldahl steam distillation method. The time for NH3 extraction by the US-assisted purge-and-trap system (20 min) was half of that by the Kjeldahl steam distillation (40 min) for 10 previously digested samples. The detection limit was 9 μg g−1 N, while for the Kjeldahl classical/indophenol method was 58 μg g−1 N. Precision was always better than 13%. In the proposed method, carcinogenic reagents are not used, contrarily to the indophenol method. Furthermore, the proposed method can be adapted for fixed-NH4+ determination.  相似文献   

5.
A rapid coulometric method for the Kjeldahl determination of nitrogen is described. The samples are digested by means of the Tecator AB digestion system which permits forty samples to be digested at the same time. The digestion products are diluted to 75 ml and 1 ml is coulometrically titrated in 1-2 min: 20-30 determinations can be performed per hour. For substances containing nitrogen in the per cent range the relative standard deviations for eight different substances were 0.1-1%.  相似文献   

6.
An analytical separation method for tryptophan and its seven metabolites of the kynurenine pathway by high-voltage paper electrophoresis is presented. Anthranilic acid, 3-hydroxyanthranilic acid, kynurenic acid, kynurenine, nicotinic acid, quinolinic acid, xanthurenic acid and unmetabolized tryptophan are measured in urine. Using radioactive labelling and scintillation counting as a quantification method, the relative standard deviation varied from 3.5% to 14.4%, corresponding to kynurenine and nicotinic acid, respectively. The recovery of labelled tryptophan added to urine was 95%. An advantage of the electrophoretic method is the minor tailing of spots and, hence, a good resolution of the components. For the monovalent anions of the kynurenine pathway metabolites, a linear correlation (r = 0.9996) was found between the experimental relative electrophoretic mobility and the quantity M-2/3, where M is the molecular mass of the anion.  相似文献   

7.
A simple method, developed primarily for simultaneous determination of total nitrogen and inorganic cations by high performance ion chromatographic (HPIC), was optimized for digestion of flue‐cured tobaccos, and compared with the traditional Kjeldahl method and atomic absorption spectrometry (AAS). Nitrogen determination by either Dumas method or Kjeldahl method is time‐consuming and tedious. Metal elements determination by either inductively coupled plasma‐mass spectrometry (ICP‐MS) or AAS may be more expensive and requires specialist equipment. The use of HPIC to simultaneous determine total nitrogen as ammonium ion and metal elements as inorganic cations after sample digestion significantly improves the speed of the analysis compared with the conventional methods. The cation‐exchange column and suppressed conductivity detector was used for determination of ammonium and inorganic cations in the presence of the elevated levels of sulfuric acid found in digested sample. The propsoed digestion method was accurate and precise, and required little investment. The determination of ammonium and inorganic cations was linear from 15 pg·L?1 up to 25 ng·L?1. The results obtained by the HPIC method were compared with those for the conventional methods approach for the determination of total nitrogen and metal elements. The application of the HPIC method is also demonstrated for a variety of other plant samples matrices.  相似文献   

8.
A method utilizing solvent extraction and analysis by gas chromatography-positive chemical ionization mass spectrometry (SE-GC-PCIMS) was developed for the analysis of three neutral hydrophobic perfluorooctanesulfonamide compounds [perfluorooctanesulfonamide (PFOSA), N-ethyl perfluorooctanesulfonamide (N-EtPFOSA), and N,N-diethyl perfluorooctanesulfonamide (N,N-Et2PFOSA)]. These compounds are suspected metabolic precursors of perfluorooctane sulfonate. The SE-GC-PCI-MS method was used to analyze all three perfluorooctanesulfonamides in fast food, fish, and Arctic marine mammal liver samples. The SE-GC-PCI-MS method produced relatively higher recoveries of the analytes (averaging 83 +/- 6%, 84 +/- 9%, and 89 +/- 19% for N,N-Et2PFOSA, N-EtPFOSA, and PFOSA, respectively) with lower coefficients of variation, and less susceptibility to matrix effects, than ion pair extraction-liquid chromatography-tandem mass spectrometric methods. Method detection limits (MDLs) were 100, 120, and 250 pg/g for N,N-Et2PFOSA, N-EtPFOSA, and PFOSA, respectively. The three compounds were found at concentrations ranging from below the MDL to 22 ng/g wet weight in fast food, fish, and Arctic marine mammal liver samples.  相似文献   

9.
A fast and sensitive method is given for analysing urinary tryptophan and six of its metabolites on the nicotinic acid pathway. Kynurenine, tryptophan, 3-hydroxykynurenine, anthranilic acid, 3-hydroxyanthranilic acid, kynurenic acid and xanthurenic acid were isocratically eluted and completely resolved with a mobile phase of acetonitrile + sodium acetate buffer, pH 4.76 (4:96, v/v). The flow rate was 0.8 mL/min at the beginning and was then linearly increased to 1.2 after 6 min; after 14 min the flow was augmented from 1.2 to 2 mL/min. The effluent was monitored with a variable UV detector set at 254 nm for the first five peaks and at 280 and 325 nm for the penultimate peak and final peak. Analytical recoveries of the compounds after deproteinization varied between 64% and 98%. The reported method should enable one to examine easily, extensively, quantitatively and routinely urinary tryptophan and the most important metabolites of the nicotinic acid pathway.  相似文献   

10.
Kynurenic acid (KYNA), one of the tryptophan metabolites, serves as an endogenous antagonist of N-methyl-d-aspartate and the alpha7 nicotinic receptors in mammalian brains. In the present study, the column-switching high-performance liquid chromatography (HPLC) method we developed for plasma KYNA was extended and validated for the determination of brain KYNA. Rat cerebrum, cerebellum and brainstem homogenates were deproteinized with acetone, and the extracts reconstituted with the mobile phase were injected onto the HPLC. In spite of the facile pretreatment, the fluorescence peak of KYNA in the cerebrum, cerebellum and brainstem was clearly observed with no interfering peaks. Intra- and inter-day precisions [relative standard deviation (%)] and accuracies [relative mean error (%)] were satisfactory (< +/-5.8%). The concentrations of KYNA in rat cerebrum, cerebellum, and brainstem were 224 +/- 65.8, 606 +/- 191, and 323 +/- 114 fmol/mg protein (n = 5), respectively. The proposed HPLC method will be a useful tool for pharmacokinetic and pharmacological researches on brain KYNA.  相似文献   

11.
Lengauer W 《Talanta》1991,38(6):659-663
The classical Dumas apparatus has been modified. The generally recommended oxidants CuO and V(2)O(5), were found to give relatively high blank values and were therefore replaced by Cu(2)O. The preparation of the Cu(2)O is described. It is an exceptionally suitable oxidant for the Dumas analysis of the Group Va nitrides as well as manganese nitrides and molybdenum nitrides because it does not release oxygen into the gas phase. The reaction of the Group IVa nitrides as well as of CrN with CuO and Cu(2)O is, however, not completely quantitative at 1000-1150 degrees in reasonable reaction times. The results of the Dumas analysis of a Group IVa nitride should be corrected by measuring the nitrogen content of the residue (e.g., by hot extraction). The relative standard deviations do not exceed 0.38%. The nitrogen contents (% w/w) of the residues range from <0.001% for Mo(2)N + MoN to 0.54% for Cr(2)N + CrN. BN, Si(3)N(4) and AlN could not be decomposed with copper oxides under the conditions used. AlN could be analysed by adding V(2)O(5), but the rsd was 0.55% and the nitrogen content in the residue was 0.52% w/w. Neither BN nor Si(3)N(4) could be analysed by addition of V(2)O(5).  相似文献   

12.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

13.
The qualitative event-specific polymerase chain reaction detection method of genetically modified (GM) RT73 rapeseed was developed based on the cloned 3' end flanking sequence of RT73 rapeseed integration. The specificity of the method for GM RT73 rapeseed was validated using several different GM rapeseed lines, GM maize lines, GM soybean line, non-GM rapeseed, and other non-GM crops. In this study, the developed method was validated through an interlaboratory study by 12 laboratories from 6 countries. The sensitivity of this method was evaluated using several mixed rapeseed meals with different GM RT73 rapeseed contents from 5.0 to 0.01% prepared by our laboratory. The evaluated results showed that all of the rapeseed endogenous reference high mobility group protein gene (HMG I/Y), figwort mosaic virus 35S (FMV 35S) promoter, and RT73 event-specific fragment could be detected from rapeseed samples at 0.1% (w/w) with a confidence level of more than 95%. All results from the 12 laboratories indicated that the developed method could be considered fit for the detection and identification of GM RT73 rapeseed.  相似文献   

14.
建立了一种利用双波长分光光度法测定烟酸酶法转化液中烟酸和6-羟基烟酸浓度的方法,选择的波长为266.5、300 nm。对烟酸生物转化产物的混合物进行分析,烟酸测定结果的标准标准偏差不大于1.30%(n=6),6-羟基烟酸测定结果的相对标准标准偏差不大于1.54%(n=6)。烟酸和6-羟基烟酸的加标回收率为95.1%~105.1%,检出限分别为0.9 mg/L和0.26 mg/L。该法与常规的HPLC方法相比,快速、准确、适于大量样品的测定。  相似文献   

15.
Tranexamic acid (TA) is a synthetic antifibrinolytic agent that is being considered as a candidate adjuvant drug for site-specific pharmaco-laser therapy of port wine stains. For drug utility studies, a high-performance liquid chromatography (HPLC)-fluorescence method was developed for the quantification of TA in blood. Platelet-poor plasma was prepared, size-separated using 3kDa cut-off centrifuge filters, and derivatized with naphthalene-2-3-dicarboxaldehyde (NDA) and cyanide. The excess of NDA was quenched after 2 min by adding tryptophan. The derivatives were separated on a 2.1mm C18 column using an acetate buffer/acetonitrile gradient. Excellent separation from plasma background was obtained at pH 5.5. Quantification was carried out at 440/520 nm. The limit of detection was 0.5 microM and the mean+/-SD recovery from whole blood was 81.7+/-10.9%. Derivatized TA samples were stable for at least 36 h at 4 degrees C. The method was successfully applied to a heat-induced TA release study from thermosensitive liposomes.  相似文献   

16.
Diffusion of ammonia is a common sample preparation method for the stable isotope analysis of inorganic nitrogen in aqueous solution. Classical diffusion methods usually require 6-12 days of diffusion and often focus on (15)N/(14)N analysis only. More recent studies have discussed whether complete N recovery was necessary for the precise analysis of stable N isotope ratios. In this paper we present a newly revised diffusion technique that allows correct and simultaneous determination of total N and (15)N at% from aqueous solutions and Kjeldahl digests, with N concentrations down to sub-0.5-mg N L(-1) levels, and it is tested under different conditions of (15)N isotope labelling. With the modification described, the diffusion time was reduced to 72 h, while the ratios of measured and expected (15)N at% were greater than 99% and the simultaneous recovery of total N was >95%. Analysis of soil microbial biomass N and its (15)N/(14)N ratio is one of the most important applications of this diffusion technique. An experiment with soil extracts spiked with (15)N-labelled yeast showed that predigestion was necessary to prevent serious N loss during Kjeldahl digestion of aqueous samples (i.e. soil extracts). The whole method of soil microbial biomass N preparation for (15)N/(14)N analysis included chloroform fumigation, predigestion, Kjeldahl digestion and diffusion. An experiment with soil spiked with (15)N-labelled yeast was carried out to evaluate the method. Results showed a highly significant correlation of recovered and added N, with the same recovery rate (0.21) of both total N and (15)N. A k(N) value of 0.25 was obtained based on the data. In conclusion, the diffusion method works for soil extracts and microbial biomass N determination and hence could be useful in many types of soil/water studies.  相似文献   

17.
An amino acid analysis by reversed-phase high-performance liquid chromatography after precolumn derivatization with phenyl isothiocyanate was adapted to the determination of free amino acids in plasma or other biological fluids and in tissue homogenates. Preparation of samples included deproteinization by 3% sulphosalicylic acid, and careful removal under high vacuum of residual phenyl isothiocyanate after derivatization. A Waters Pico-Tag column (15 cm long) was used, immersed in a water-bath at 38 degrees C. In rat or human plasma, separation of 23 individual amino acids, plus the unresolved pair tryptophan and ornithine, was obtained within 13 min. Including the time for column washing and re-equilibration, samples could be chromatographed at 23-min intervals. Variability was tested for each amino acid by calculating the coefficients of variation of retention times (less than 1% in the average) and peak areas (less than 4% for both intra-day and inter-day determinations). The linearity for each standard amino acid was remarkable over the concentration range 3-50 nmol/ml. The mean recovery of amino acid standards added to plasma prior to derivatization was 97 +/- 0.8%, except for aspartate (82%) and glutamate (81%). This method is rapid (almost three samples per hour can be analysed, more than in any other reported technique), with satisfactory precision, sensitivity and reproducibility. Therefore, it is well suited for routine analysis of free amino acids in both clinical and research work.  相似文献   

18.
The results of an international collaborative study for the determination of 5% erucic acid in four samples of edible fats and oils with differing levels of 22:1 isomers other than erucic acid, based on the use of wall-coated (SILAR-5CP) open-tubular gas-liquid chromatography, are examined. The same samples had been analyzed in a separate collaborative study by an alternative and more complex method based on argentation thin-layer chromatography. Both methods rejected about the same proportion of participating laboratories and a few individual results from otherwise acceptable laboratories. The means and repeatabilities of the two methods were similar, but the gas-liquid chromatographic method showed better reproducibility.  相似文献   

19.
The objective of this collaborative study was to evaluate the proposed method for determining the total nitrogen in soy sauce by the Kjeldahl method submitted to the Codex Alimentarius Commission for endorsement in accordance with the protocol for the design, conduct, and interpretation of method-performance studies. The digestive conditions of the proposed method are the addition of 10 mL of H2SO4, 10 g (8 g by using a block digester) of K2SO4, and 1 mL of 20% CuSO4 x 5H2O and 80 min boiling period after the liquid is cleared by a heating device. Seventeen laboratories participated, analyzing five soy sauce samples as blind duplicates. Since the volume sampling method used in the JAS (Japanese Agricultural Standard) method showed lower accuracy of data because of the density of soy sauce, the method of sampling by weight was adopted as the proposed method. The total amount of outlier data was within acceptable limits for method-performance studies (< or = 22.2%). Lysine and ammonium sulfate recoveries for all laboratories were > or = 98% and > or = 99% respectively. The RSDr (repeatability relative standard deviation) values ranged from 0.4 to 1.3%, and the RSDR (reproducibility relative standard deviation) values were from 0.8 to 1.9%. HORRAT (RSDR/predicted RSDR) for the reproducibility showed 0.2 to 0.4, indicating acceptable precision of the method and excellent analytical performance.  相似文献   

20.
全自动凯氏定氮仪测定化肥中的含氮量   总被引:2,自引:0,他引:2  
建立全自动凯氏定氮仪检测化肥中氮含量的分析方法。称取总氮量在0.03~0.3 g范围的样品,经消解仪消解及全自动凯氏定氮仪碱化蒸馏,以硼酸为接收液,用0.15~0.20 mol/L的盐酸标准溶液进行自动滴定。该方法加标回收率为99.0%~101.5%,测定结果的相对标准偏差小于1.0%(n=6)。与国标GB/T 8527–2010法测定结果无显著性差异,全自动凯式定氮仪法的准确度、精密度均优于国标方法,而且所用试剂少、分析时间短,满足实验室快速检测大批量化肥中含氮量的需要。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号