首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

2.
Mo H  Zhu L  Xu W 《Journal of separation science》2008,31(13):2470-2475
Separation of inorganic anions in CE is often a challenging task because the electrophoretic mobilities of inorganic anions are comparable to or even greater than the EOF mobility. In this study, we present the use of ionic liquids (ILs) as background electrolytes (BGEs) in CE of inorganic anions. The 1-alkyl-3-methylimidazolium-based ILs as BGEs dynamically coated the capillary wall and induced a reversed EOF. This allowed the anions to comigrate with the EOF and yielded a rapid separation. Increasing the alkyl chain length of the ILs and BGE concentration can significantly improve the separation resolution. With 40 mM 1-butyl-3-methylimidazolium tetrafluoroborate as BGE, good separations of five model anions (Br-, I-, NO2(-), NO3(-), and SCN-) were achieved in a range of buffer pH values. The separation efficiency was as high as 34 600-155 000, and the RSDs of the migration times were less than 0.8% (n = 5).  相似文献   

3.
Capillary electrophoresis (CE) using sulfobetaine-type zwitterionic micelles as the background electrolyte (BGE) has been used to determine inorganic anions in human saliva. The zwitterionic micelles resulted in unique migration behavior for the separation of inorganic anions. They also prevented adsorption of proteins on the inner wall of the capillary. These properties of the zwitterionic micelles enabled the direct determination of inorganic anions in human saliva. Three species of inorganic anions, NO2-, NO3-, and SCN-, were found in real samples and the analysis was achieved within 3 min. Direct UV-absorption was used as the detection method and the detection limits for these anions were 2.0, 1.0, and 5.0 micromol L(-1), respectively (0.09, 0.06, and 0.30 microg mL(-1)).  相似文献   

4.
Separations of common inorganic anions were carried out on ODS columns coated with two long-chain alkylimidazolium ionic liquids ([C(12)MIm]Br and [C(14)MIm]Br) as new cationic surfactants for ion chromatography. With phthalate buffer solution as the mobile phases and non-suppressed conductivity detection, high column efficiencies and excellent selectivity were obtained in the separation of inorganic anions. Chromatographic parameters are calculated and the results show that the coated column possesses significant potential for the analysis of some inorganic anions such as CH(3)COO(-), IO(3)(-), Cl(-), BrO(3)(-), NO(2)(-), Br(-), NO(3)(-), SO(4)(2-), I(-), BF(4)(-), and SCN(-). The effect of eluent pH values on the separation of anions has been studied on the column coated with [C(12)MIm]Br. The stability of the coated columns was also examined.  相似文献   

5.
Ion chromatography is the most popular instrumental analytical method used for the determination of anions and cations in water and wastewater. Isocratic ion chromatography with suppressed conductivity detection is frequently used in laboratories carrying out routine analyses of inorganic anions. The paper presents the results of the research into the influence of selected inorganic anions dominant in environmental samples (Cl(-), NO(3)(-), SO(4)(2-)) on the possibility of simultaneous determination of F(-), Cl(-), NO(2)(-), NO(3)(-), PO(4)(3-) and SO(4)(2-) with the application of this most popular ion chromatography type in standard separation conditions. Four Dionex and four Metrohm anion-exchange columns were tested in standard separation conditions recommended by their manufacturers with both standard solutions and environmental samples with complex matrix.  相似文献   

6.
Kubán P  Hauser PC 《Lab on a chip》2008,8(11):1829-1836
The determination of inorganic ions in clinical samples in less than 90 seconds was demonstrated for microchip capillary electrophoresis using capacitively coupled contactless conductivity detection (C(4)D). Bare electrophoresis chips were used in combination with external electrodes which were part of the chip holder. In order to achieve the required selectivity and sensitivity, an optimization of the electrode layout was carried out. Limits of detection (LOD) of 1 microM for K(+), 1.5 microM for Ca(2+), 3 microM for Na(+), 1.75 microM for Mg(2+) and 7.5 microM for Li(+) were achieved. The determination of inorganic cations (NH(4)(+), K(+), Na(+), Ca(2+), Mg(2+)) and anions (Cl(-), NO(3)(-), SO(4)(2-), phosphate) in blood serum and urine samples was possible in one common electrolyte solution containing 15 mM L-arginine, 10.75 mM maleic acid and 1.5 mM 18-crown-6 at pH 5.90 by simply switching the separation voltage from positive to negative polarity. Lithium, present at significant levels when used for therapeutic purposes, can also be determined in blood serum using a slightly modified background electrolyte solution.  相似文献   

7.
The aim of this study was to develop a simple and rapid method of capillary electrophoresis using a short end multiple injection in free solution to determine simultaneously the biological sample volume and analytes concentration. The method consists of a sequence of injection steps with an internal standard as the reference for correction of the volume of sample collected. The procedure was applies in the determination of NO(3)(-) and SCN in saliva samples. The background electrolyte was composed of 12 mM tris(hydroxymethyl)aminomethane and 8.5mM sulfuric acid, at pH 2.5. The internal standard used was BrO(3)(-). A fused silica capillary (48.5 cm total length, 8.5 cm effective length and 75 μm i.d.) coated with chitosan was used in a short-end injection configuration. Modification of the electroosmotic flow (EOF) using dynamic coating resulted in a controlled and stable EOF, contributing to the rapid separation of anions (0.36 min) in co-electroosmotic mode. The validation of the method for correcting the volume of saliva collected with a swab showed a difference of less than 3.5% compared with the predicted value and a correlation of 0.999. The limits of detection for NO(3)(-) and SCN(-) were 0.13 and 0.23 mg L(-1), respectively. The inter-day precision of the method determined for both analytes was less than 5% and the recovery ranged between 97 and 102%.  相似文献   

8.
In capillary electrophoresis (CE) analysis of small inorganic anions, the ability to control the electroosmotic flow (EOF) and the ability to alter the electrophoretic mobility of the ions are essential to improve resolution and separation speed. In this work, a CE method for separation of small inorganic anions using indirect detection in mixed methanol/water buffers is presented. The suitability of different UV absorbing probes commonly used for indirect detection including chromate, iodide, phthalate, benzoate, trimellitate, and pyromellitate, in mixed methanol/water buffers is examined. The effect of the electrolyte buffer system, including the pH, buffer concentration and the organic solvent on the electrophoretic mobility of the probes and analytes are also investigated. The EOF was reversed using cationic surfactant, cetyltrimethylammonium bromide (CTAB) so ions were separated under co-EOF mode. The organic solvent alters the electrophoretic mobility of the probes and the analytes differently and hence choice of the appropriate probe is essential to achieve high degree of detection sensitivity. Separations of six anions in less than 2.5 min were accomplished in buffers containing up to 30% MeOH. Adjustment of the methanol content helps to improve the selectivity and resolution of inorganic anions. Limit of detection, reproducibility and application of the method for quantification of anions in water samples will also be discussed.  相似文献   

9.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

10.
An ion chromatography (IC) method has been proposed for the determination of seven common inorganic anions (F(-), H(2)PO(4)(-), NO(2)(-), Cl(-), Br(-), NO(3)(-), and SO(4)(2-)) and/or five common inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via a single 10-port switching valve. The 10-port valve was switched for the separation of either cations or anions in a single chromatographic run. When 1.0mM trimellitic acid (pH 2.94) was used as the eluent, the seven anions and the five cations could be separated on the anion-exchange column and the cation-exchange column, respectively. The elution order was found to be F(-)相似文献   

11.
Selectivity and robustness of the pyromellitic acid (PMA) based background electrolyte was improved in order to increase its applicability for routine analysis of inorganic and organic anions in real samples. An electrolyte composed of 6.75 mM PMA, 0.5 mM hexamethonium hydroxide as electroosmotic flow (EOF) modifier, Ca(2+) 0.05 mM as complexation agent and pH adjusted to 7.6 with TEA 1M allows for the separation of 22 inorganic and organic anions in less than 17 min. Good RSDs for within-day migration time reproducibility (0.03-0.9%) and day-to-day analyses (0.04-1.4%) were obtained by the use of two internal standards, allowing for an accurate compound identification. The detection limits ranged from 0.1 to 0.4 mgL(-1) (S/N=3) for hydrodynamic injection (1250 mbars). The applicability of the proposed method was demonstrated by the analysis of inorganic and organic anions in diverse real samples. The recoveries obtained ranged from 93 to 106%.  相似文献   

12.
A novel and easy method for the separation of inorganic anions by capillary electrophoresis using a polymeric ionic liquid (PIL), poly(1-vinyl-3-butylimidazolium bromide) as a background electrolyte modifier has been developed. The PIL has been proved to generate a reversed electroosmotic flow which reduces the analysis time and improves the separation significantly. Effects of the PIL concentration and buffer composition (pH and concentration) were evaluated on basis of the resolution and efficiency of the sample. Under optimum conditions, good separation of six model inorganic anions was achieved with high efficiency and excellent reproducibility within 3 min. The results obtained indicate that the combination of reversed EOF and the association between the analytes and the PIL on the capillary wall or BGE play a prominent role in the separation of anions. Therefore, the PIL presents a useful alternative for the BGE modifier in the study of inorganic anions by CE.  相似文献   

13.

A capillary zone electrophoresis (CZE) method applied short-effective length of capillary (11 cm) and low separation voltage (5 kV) was developed for the fast and quantitative determination of Cl m , $ {\rm NO}_2^ - $ , $ {\rm SO}_4^{2 - } $ , $ {\rm NO}_3^ - $ , $ {\rm HCO}_3^ - $ in snow sample. Baseline separation of inorganic anions and organic anions was achieved within 55 s. Indirect absorbance detection of anions was accomplished with a chromate - based background electrolyte modified with cetyltrimethylammonium bromide (CTAB) and acetonitrile at pH 9.5. The effect of the pH, the concentration of electrolyte and modifiers on the resolution was investigated. The application of electrokinetic injection using butyric acid as internal standard created the described method fast, sensitive, and quantitative, with good relative standard deviation (RSD), for migration times from 0.1 to 0.3% and for peak areas from 1.8 to 4.0%. The limits of detection (LOD) were 0.03 mg L m 1 Cl m , 0.1 mg L m 1 $ {\rm NO}_2^ - $ , 0.07 mg L m 1 $ {\rm SO}_4^{2 - } $ , 0.08 mg L m 1 $ {\rm NO}_3^ - $ , 0.05 mg L m 1 F m , and 0.2 mg L m 1 $ {\rm HCO}_3^ - $ , respectively. Standard addition recoveries of Cl m , $ {\rm NO}_2^ - $ , $ {\rm SO}_4^{2 - } $ , $ {\rm NO}_3^ - $ , F m , and $ {\rm HCO}_3^ - $ in snow sample were between 91 and 104%. This method has been shown promising results for the determination of small anions in snow sample.  相似文献   

14.
A new capillary electrophoretic (CE) method was developed for the simple and selective determination of iodine in 0.5 mol l(-1) NaCl. The proposed method is based on the in-capillary derivatization of iodine with thiosulfate ions using the zone-passing technique and direct photometric detection of the iodide and tetrathionate formed. The optimal conditions for the separation and derivatization reaction were established by varying the concentration of iodine, electrolyte pH and applied voltage. The optimized separations were carried out in phosphate electrolyte (pH 6.86) using direct photometric detection at 253.7 nm. Common photometric detection absorbing anions such as Cl(-), NO(2)(-), S(2)O(3)(2-) did not give any interference. Valid calibration (r(2) = 0.994) is demonstrated in the range 16.5-198.1 mg l(-1) of iodine. The detection limit (calculated according to K. Doerffel, Statistik in der analytischen Chemie, 1990) was 11.53 mg l(-1) (by iodide peak area) and 8.45 mg l(-1) (by tetrathionate peak area). The proposed system was applied to the determination of iodine after oxidation of iodide in underground water.  相似文献   

15.
King M  Paull B  Haddad PR  Macka M 《The Analyst》2002,127(12):1564-1567
Light emitting diodes (LEDs) are known to be excellent light sources for detectors in liquid chromatography and capillary electromigration separation techniques, but to date only LEDs emitting in the visible range have been used. In this work, a UV LED was investigated as a simple alternative light source to standard mercury or deuterium lamps for use in indirect photometric detection of inorganic anions using capillary electrophoresis with a chromate background electrolyte (BGE). The UV LED used had an emission maximum at 379.5 nm, a wavelength at which chromate absorbs strongly and exhibits a 47% higher molar absorptivity than at 254 nm when using a standard mercury light source. The noise, sensitivity and linearity of the LED detector were evaluated and all exhibited superior performance to the mercury light source (up to 70% decrease in noise, up to 26.2% increase in sensitivity, and over 100% increase in linear range). Using the LED detector with a simple chromate-diethanolamine background electrolyte, limits of detection for the common inorganic anions, Cl-, NO3-, SO4(2-), F- and PO4(3-) ranged from 3 to 14 microg L(-1), using electrostatic injection at -5 kV for 5 s.  相似文献   

16.
Kubán P  Hauser PC 《Electrophoresis》2005,26(16):3169-3178
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.  相似文献   

17.
Zhang Z  Li D  Liu X  Subhani Q  Zhu Y  Kang Q  Shen D 《The Analyst》2012,137(12):2876-2883
An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating. Two C(4)Ds were placed near both ends of the capillary column and the output difference between them was measured. With 15 mM potassium hydrogen phthalate used as the eluent, good separation of a mixture of inorganic anions (F(-), Cl(-), NO(2)(-), NO(3)(-)) was achieved. The detection limits of conventional C(4)D are 1.6, 0.28, 0.53, and 0.47 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. To further enhance the sensitivity, the capacitive impedance from C(4)D was neutralized by an inductive impedance from a piezoelectric resonator. An increase in sensitivity by a factor of 7-8 was achieved in the resonating C(4)D in comparison with the conventional C(4)D. The detection limits of the resonating C(4)D are 0.23, 0.041, 0.065, and 0.059 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. The response of the resonating C(4)D was analyzed based on an equivalent circuit model.  相似文献   

18.
A carboxybetaine-type zwitterionic stationary phase obtained by immobilizing Mitsubishi Reagent EF-700 (C(8)F(17)SO(2)NHC(3)H(6)N(+) (CH(3))(2)-C(2)H(4)-COO(-)) onto a reversed-phase column was used for chromatographic separation of ions. When aqueous electrolyte solutions having higher pH values (>8) were used as eluents, the model analyte ions (NO(2)(-), H(2)PO(4)(-), Cl(-), Br(-), NO(3)(-), ClO(3)(-), I(-) and SCN(-)) were co-eluted and appeared at the void volume of this HPLC system. However, when aqueous electrolyte solutions having lower pH values (<5.5) were used as eluents, these anions were well retained and separated. Furthermore, when acetate buffers (NaAc/HAc) were used as eluents, plots of log k' (k', retention factor) versus pH of eluents (at constant [NaAc+HAc]), and log k' versus log [NaAc+HAc] (at constant pH), were linear with negative slopes. Breakthrough curves for acid solutions obtained using conductivity detection showed that H(+) ions and their conjugate anions were both retained on the stationary phase and the degree of binding was found to be independent of the acid species used. The degree to which the eluent cation was bound onto the carboxylate functionality of the zwitterion was found to exert a major effect on the retention of analyte anions. A strongly bound cation, such as H(+), reduced electrostatic repulsion effects exerted by the carboxylate functionality on analyte anions, so that they could freely access the quaternary ammonium sites on the zwitterion. It is concluded based on these experimental results that both the charges on the zwitterionic stationary phase make meaningful contributions to the separation of the analyte ions.  相似文献   

19.
利用间接紫外毛细管区带电泳方法完成了对爆炸残留物中7种无机离子(K+,NH+4,NO-2,NO-3,SO2-4,ClO-3,ClO-4)的分离检测。阳离子测定采用的缓冲体系为10 mmol/L吡啶(pH 4.5)-3 mmol/L冠醚,K+和NH+4在2.6 min内达到基线分离,检出限分别为0.25 mg/L和0.10 mg/L(S/N=3)。阴离子测定采用的缓冲体系为40 mmol/L硼酸-1.8 mmol/L重铬酸钾-2 mmol/L硼酸钠(pH 8.6),氢氧化四甲铵为电渗流改性剂,5种阴离子在4.6 min内达到基线分离,检出限为0.10~1.85 mg/L。该方法已成功地应用于实际爆炸物样品种类的判定分析,取得了很好的结果。  相似文献   

20.
A novel suppressor unit for capillary ion chromatography was designed to reduce the background conductivity and at the same time to increase the analyte signal. Regeneration of the suppressor was carried out on-line by passing an appropriate acidic solution through the column to displace the accumulated eluent cations. By using two 6-port microswitching valves and two packed capillary column suppressors, the background conductivity of sodium carbonate-bicarbonate mobile phase was maintained at low conductivity for continuous chromatographic runs, and the detection limits at low ppb levels were achieved. The relative standard deviations (RSDs) for the retention time, peak area and peak height of six common inorganic anions (0.05mM each of F(-), Cl(-), NO(2)(-), Br(-), NO(3)(-) and SO(4)(2-)) were between 0.5-0.9, 1.1-4.6 and 0.7-4.9%, respectively. The present system was successfully applied to the determination of inorganic anions in river water and tap water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号