首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensor based on quartz-enhanced photoacoustic spectroscopy (QEPAS) was evaluated for the detection of trace levels of ethylene at atmospheric pressure using a fiber coupled DFB diode laser emitting in the 1.62 μm spectral range. A noise-equivalent QEPAS signal of ∼4 ppm C2H4 was achieved for a 0.7 s data acquisition time using wavelength-modulation with a second-harmonic detection scheme on the strongest C2H4 absorption peak at 6177.14 cm−1 with an average optical power of ∼15 mW. Improved detection sensitivity of 0.5 and 0.3 ppm C2H4 (1σ) was demonstrated using longer averaging time of 70 and 700 s, respectively. Important characteristics for the QEPAS based sensor operation in real-world conditions are presented, particularly the influence of external temperature variations. Furthermore, the response time of the ethylene sensor was measured in different configurations and it is shown that the QEPAS technique can provide a response time in a few seconds range even without active gas flow.  相似文献   

2.
The main characteristics that a sensor must possess for trace gas detection and pollution monitoring are high sensitivity, high selectivity and the capability to perform in situ measurements. The photacoustic Helmholtz sensor developed in Reims, used in conjunction with powerful Quantum Cascade Lasers (QCLs), fulfils all these requirements. The best cell response is # 1200 V W−1 cm and the corresponding ultimate sensitivity is j 3.3 × 10−10 W cm−11 Hz−11/2. This efficient sensor is used with mid-infrared QCLs from Alpes Lasers to reach the strong fundamental absorption bands of some atmospheric gases. A first cryogenic QCL emitting at 7.9 μm demonstrates the detection of methane in air with a detection limit of 3 ppb. A detection limit of 20 ppb of NO in air is demonstrated using another cryogenic QCL emitting in the 5.4 μm region. Real in-situ measurements can be achieved only with room-temperature QCLs. A room-temperature QCL emitting in the 7.9 μm region demonstrates the simultaneous detection of methane and nitrous oxide in air (17 and 7 ppb detection limit, respectively). All these reliable measurements allow the estimated detection limit for various atmospheric gases using quantum cascade lasers to be obtained. Each gas absorbing in the infrared may be detected at a detection limit in the ppb or low-ppb range.  相似文献   

3.
A gas sensor based on quartz-enhanced photoacoustic detection and an external cavity quantum cascade laser was realized and characterized for trace nitric oxide monitoring using the NO R(6.5) absorption doublet at 1900.075 cm−1. Signal and noise dependence on gas pressure were studied to optimize sensor performance. The NO concentration resulting in a noise-equivalent signal was found to be 15 parts per billion by volume, with 100 mW optical excitation power and a data acquisition time of 5 s.  相似文献   

4.
QEPAS spectrophones: design, optimization, and performance   总被引:2,自引:0,他引:2  
The impact of design parameters of a spectrophone for quartz-enhanced photoacoustic spectroscopy on its performance was investigated. The microresonator of spectrophone is optimized based on an experimental study. The results show that a 4.4 mm-long tube with 0.6 mm inner diameter yields the highest signal-to-noise ratio, which is ∼30 times higher than that of a bare QTF at gas pressures between 400 and 800 Torr. The optimized configuration demonstrates a normalized noise-equivalent absorption coefficient (1σ) of 3.3×10−9 cm−1W/Hz1/2 for C2H2 detection at atmospheric pressure. The effect of the changing carrier gas composition is studied. A side-by-side sensitivity comparison between QEPAS and conventional photoacoustic spectroscopy technique is reported.  相似文献   

5.
High resolution diode laser spectroscopy has been applied to the detection of hydrogen sulphide at ppm levels utilizing different transitions within the region of the ν 1+ν 2+ν 3 and 2ν 1+ν 2 combination bands around 1.58 μm. Suitable lines in this spectral region have been identified, and absolute absorption cross sections have been determined through single-pass absorption spectroscopy and confirmed in the Doppler linewidth regime using cavity enhanced absorption spectroscopy (CEAS). The desire for a sensitive system potentially applicable to H2S sensing at atmospheric pressure has led to an investigation on suitable transitions using wavelength modulation spectroscopy (WMS). The set-up sensitivity has been calculated as 1.73×10−8 cm−1 s1/2, and probing the strongest line at 1576.29 nm a minimum detectable concentration of 700 ppb under atmospheric conditions has been achieved. Furthermore, pressure broadening coefficients for a variety of buffer gasses have been measured and correlated to the intermolecular potentials governing the collision process; the H2S–H2S dimer well depth is estimated to be 7.06±0.09 kJ mol−1.  相似文献   

6.
We describe the application of a long-wavelength vertical-cavity surface-emitting laser (VCSEL) with extended tuning range to the detection of benzene vapor at atmospheric pressure. A benzene absorption feature centered at 1684.24 nm was accessed by reducing the heat sink temperature of a VCSEL designed for room-temperature operation to −55°C. This allowed us to increase the injection current and thus to extend a single-scan tuning interval up to 46.4 cm−1 or 13.2 nm around a central wavelength of 1687.4 nm. Five absorption lines of methane in the 5903–5950 cm−1 range could be acquired within single laser scans at a repetition rate of 500 Hz. A benzene absorption feature between 5926 and 5948 cm−1 was recorded for concentration measurements at atmospheric pressure using a single-pass 1.2 m absorption cell. A 50 ppmv mixture of CH4 in N2 was introduced into the cell along with benzene vapor to calibrate benzene concentration measurements. Benzene mixing ratios down to ∼90 ppmv were measured using a direct absorption technique. The minimum detectable absorbance and detection limit of benzene were estimated to be ∼10−4 and 30 ppmv, respectively. Using the wavelength modulation technique, we measured a second harmonic sensor response to benzene vapor absorption in air at atmospheric pressure as a function of modulation index. We conclude that a low-temperature monolithic VCSEL operating near 1684 nm can be employed in compact benzene sensors with a detection limit in the sub-ppm range.  相似文献   

7.
A computer-aided optoacoustic gas analyzer based on a continuous13C16C2 laser for multicomponent pollution of atmospheric air is described. The analyzer has the ability to detect absorption of radiation by detected substances at the level of ∼1·10−9 cm−1 at a time resolution of 30 sec. Results of an experiment on simultaneous detection of H2O, CO2, NO2, NH3, HNO3, OCS, and C2H4 in the atmospheric air using 40 laser lines are presented. B. I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, 68, F. Skorina Ave., Minsk, 220072, Belarus. Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 66, No. 3, pp. 345–350, May–June, 1999.  相似文献   

8.
We describe the application of the vertical-cavity surface-emitting laser (VCSEL) to absorption spectroscopy of the ethylene oxide (EO) Q-branch near 1693 nm. The VCSEL was electrically scanned over spectral intervals of up to ∼13 cm−1 at a 1 kHz repetition rate. A methane absorption line at 5903.3 cm−1 and Fabry–Pérot etalon with a free spectral range of 0.4 cm−1 were used to calibrate frequency scale. The EO was mixed with ambient air, and total gas pressure and mixing ratios were varied from a few mbar to 1 bar and from ∼102 to 105 parts per million, respectively. A rapid roll off of EO absorbance at 5903.7 cm−1 was observed at gas pressures below ∼0.5 bar. A linear dependence of EO peak absorbance on mixing ratio was found at a total gas pressure of 1 bar. We conclude that monolithic VCSELs operating near 1693 nm could be used in EO sensors with a detection limit in the ppb range.  相似文献   

9.
A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8‰(±1σ) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 μm (∼2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations. Received: 16 April 2002 / Revised version: 28 May 2002 / Published online: 21 August 2002 RID="*" ID="*"Corresponding author. Fax: +1-713/5245237, E-mail: fkt@rice.edu  相似文献   

10.
Tunable diode-laser absorption of CO2 near 2.7 μm incorporating wavelength modulation spectroscopy with second-harmonic detection (WMS-2f) is used to provide a new sensor for sensitive and accurate measurement of the temperature behind reflected shock waves in a shock-tube. The temperature is inferred from the ratio of 2f signals for two selected absorption transitions, at 3633.08 and 3645.56 cm−1, belonging to the ν 1+ν 3 combination vibrational band of CO2 near 2.7 μm. The modulation depths of 0.078 and 0.063 cm−1 are optimized for the target conditions of the shock-heated gases (P∼1–2 atm, T∼800–1600 K). The sensor is designed to achieve a high sensitivity to the temperature and a low sensitivity to cold boundary-layer effects and any changes in gas pressure or composition. The fixed-wavelength WMS-2f sensor is tested for temperature and CO2 concentration measurements in a heated static cell (600–1200 K) and in non-reactive shock-tube experiments (900–1700 K) using CO2–Ar mixtures. The relatively large CO2 absorption strength near 2.7 μm and the use of a WMS-2f strategy minimizes noise and enables measurements with lower concentration, higher accuracy, better sensitivity and improved signal-to-noise ratio (SNR) relative to earlier work, using transitions in the 1.5 and 2.0 μm CO2 combination bands. The standard deviation of the measured temperature histories behind reflected shock waves is less than 0.5%. The temperature sensor is also demonstrated in reactive shock-tube experiments of n-heptane oxidation. Seeding of relatively inert CO2 in the initial fuel-oxidizer mixture is utilized to enable measurements of the pre-ignition temperature profiles. To our knowledge, this work represents the first application of wavelength modulation spectroscopy to this new class of diode lasers near 2.7 μm.  相似文献   

11.
We present a system for molecular spectroscopy using a broadband mid-infrared laser with near-infrared detection. Difference frequency generation of a Yb:fiber femtosecond laser produced a mid-infrared (MIR) source tunable from 2100–3700 cm−1 (2.7–4.7 μm) with average power up to 40 mW. The MIR spectrum was upconverted to near-infrared wavelengths for broadband detection using a two-dimensional dispersion imaging technique. Absorption measurements were performed over bandwidths of 240 cm−1 (7.2 THz) with 0.048 cm−1 (1.4 GHz) resolution, and absolute frequency scale uncertainty was better than 0.005 cm−1 (150 MHz). The minimum detectable absorption coefficient per spectral element was determined to be 4.4×10−7 cm−1 from measurements in low pressure CH4, leading to a projected detection limit of 2 parts-per-billion of methane in pure nitrogen. In a natural atmospheric sample, the methane detection limit was found to be 30 parts-per-billion. The spectral range, resolution, and frequency accuracy of this system show promise for determination of trace concentrations in gas mixtures containing both narrow and broad overlapping spectral features, and we demonstrate this in measurements of air and solvent samples.  相似文献   

12.
The dynamical method previously proposed for detecting water clusters under atmospheric conditions after the adiabatic expansion of the gas mixture under investigation has been additionally justified. New experimental results of the detection of absorption induced by water clusters near 10600 cm−1 with a resolution of about 1.5 cm−1 are reported.  相似文献   

13.
The Frascati Φ-factory DAΦNE has successfully completed experimental runs for the three main detectors, KLOE, FINUDA and DEAR. The best peak luminosity achieved so far is 1.6 × 1032 cm−2 s−1, while the best daily integrated luminosity is 10 pb−1. At present the DAΦNE team is preparing an upgrade of the collider based on the novel crab waist collision scheme. The upgrade is aimed at pushing the luminosity towards 1033cm−2s−1. In this paper we describe present collider performance and discuss ongoing preparatory work for the upgrade. for DAΦNE Collaboration Team [1] The text was submitted by the author in English.  相似文献   

14.
Reactive cosputtering is employed to prepare high-permittivity HfTiO gate dielectric on n-Ge substrate. Effects of Ge-surface pretreatment on the interface and gate leakage properties of the dielectric are investigated. Excellent performances of Al/HfTiO/GeO x N y /n-Ge MOS capacitor with wet–NO surface pretreatment have been achieved with a interface-state density of 2.1×1011 eV−1 cm−2, equivalent oxide charge of −7.67×1011 cm−2 and gate leakage current density of 4.97×10−5 A/cm2 at V g =1 V.  相似文献   

15.
A trace gas sensor based on quartz enhanced photoacoustic spectroscopy (QEPAS) was evaluated using humidified nitrogen samples and ambient air. Relaxation processes following vibrational excitation of 2ν3 state of CH4 were investigated. Sensor performance at different gas pressures could be predicted based on a developed kinetic model. The experimentally determined normalized detection sensitivity for CH4 in humid gas is 1.0×10-8 cm-1 W/Hz1/2. PACS  82.80.Kq; 42.62.Fi  相似文献   

16.
A flexible and portable trace nitrogen dioxide sensor based on cavity ringdown spectroscopy using an optical fiber-coupled high-finesse cavity was successfully demonstrated. Tailoring the spatial mode matching condition of the core of an optical fiber and high-finesse external cavity allows for effective optical feedback into an antireflection-coated laser diode for stable resonant enhancement of the external cavity. The external cavity, which works as a ringdown cavity, could be remotely located from the light source and receiver section by only a single mode optical fiber. The sensitivity was found to be 1.0×10−7 cm−1 in a compact 1-cm3 ringdown cavity volume.  相似文献   

17.
A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of trace amounts of chlorzoxazone and Ibuprofen in pharmaceutical tablets using optical sensor Eu-Tetracycline HCl doped in sol–gel matrix. The chlorzoxazone or Ibuprofen can remarkably enhance the luminescence intensity of Eu-Tetracycline HCl complex doped in a sol–gel matrix in dimethylformamide (DMF) at pH 9.7 and 6.3, respectively, λex = 400 nm. The enhancing of luminescence intensity peak of Eu-Tetracycline HCl complex at 617 nm is proportional to the concentration of chlorzoxazone or Ibuprofen a result that suggested profitable application as a simple optical sensor for chlorzoxazone or Ibuprofen assessment. The dynamic ranges found for the determination of chlorzoxazone and Ibuprofen concentration are 5 × 10−9–1 × 10−4 and 1 × 10−8–7 × 10−5 mol L−1, and the limit of detection (LOD) and quantitation limit of detection (LOQ) are 3.1 × 10−10 , 9.6 × 10−10 and 5.6 × 10−10, 1.7 × 10−9 mol L−1, respectively.  相似文献   

18.
Organic thin-film transistors (OTFTs) with top- and bottom-contact configurations were fabricated using silver nano-inks printed by laser forward transfer for the gate and source/drain electrodes with pentacene and poly-4-vinylphenol as the organic semiconductor and dielectric layers, respectively. The volume of the laser-printed Ag pixels was typically in the subpicoliter (0.2–0.4 pl) range. The top-contact OTFTs resulted in lower contact resistance compared to those obtained from the bottom-contact OTFTs, and showed improved overall device performance. The top-contact OTFTs exhibited field-effect mobilities of ∼0.16 cm2 V−1 s−1 and on/off current ratios of ∼105.  相似文献   

19.
Using an ionization sensor, it was found that weakly ionized plasma with an ionization degree larger than 10−6 is formed under exposure to UV radiation of a high-current pulsed electric discharge in gas (air, nitrogen, xenon, and krypton) at atmospheric pressure at a distance of ∼1.2–2.5 cm from the discharge boundary. It was shown that the structure of such discharge includes, in addition to the discharge channel, a dense shell and a shock wave, also a region of weakly ionized and excited gas before the shock wave front. The mechanism of discharge expansion in dense gas is ionization and heating of gas involved in the discharge due to absorption of the UV energy flux from the discharge channel and the flux of the thermal energy transferred from the discharge channel to the discharge shell due to electron thermal conductivity.  相似文献   

20.
Atmospheric plasma spray is a fast and economical process for deposition of yttria-stabilized zirconia (YSZ) electrolyte for solid oxide fuel cells. YSZ powders have been used to prepare plasma-sprayed thin ceramic films on the metallic substrate employing plasma spray technology at atmospheric pressure. Alumina doping was employed to improve the structural characteristics and electrical properties of YSZ. The effect of alumina addition from 1 to 5 wt.% on the properties of plasma-sprayed YSZ films was investigated. It was found that the gas permeability of the Al-doped YSZ electrolyte layer reached a level of 8.6 × 10−7 cm4 gf−1 s−1, which is a necessary value for the practical operation of solid oxide fuel cells. Alumina doping considerably increased the ionic conductivity of plasma-sprayed YSZ. The open circuit voltage of the alumina-doped YSZ coating was approximately equal to the theoretical value for dense YSZ material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号