首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this work, ionic liquid–graphene nanosheets (IL–GNs) were synthesised and used as an enhanced material for sensitive detection of methyl parathion (MP) by electrochemical method. IL–GNs were characterised by UV–Vis spectroscopy, transmission electron microscopy (TEM), X-ray photo-electron spectroscopy (XPS), Fourier transform Infrared (FT-IR) spectroscopy and Raman spectroscopy, which confirmed that IL was successfully covered on the surface of GNs. Significantly, due to the coupling of excellent properties of GNs and IL, the IL–GNs-modified glassy carbon electrode (IL–GNs/GCE) showed higher signals for MP response than the GNs/GCE and bare GCE. At the IL–GNs/GCE, the peak currents increase linearly with the concentration of MP in the range of 5.3 ng/mL to 2.6 μg/mL with the detection limit of 1.1 ng/mL, which was better than other enzyme-based and enzymeless sensors. The IL–GNs-based electrochemical sensor was also successfully demonstrated for the detection of water sample with satisfactory results. Furthermore, the proposed electrochemical sensor exhibited satisfied stability and reproducibility. The simple sensing platform can be extended to detect other organophosphate pesticide.  相似文献   

2.
This study used a facile method to develop a novel silver/Graphene–polypyrrole (Ag/G–PPy)-modified electrode that can be used as an electrochemical sensor for levosimendan detection. The properties of the synthesized Ag/G–PPy-modified electrode were examined through field-emission scanning electron microscopy, x-ray diffraction, and transmission electron microscopy. The Ag/G–PPy-modified electrode exhibited satisfactory current signals toward levosimendan concentrations ranging from 0.21 to 6.88 μM and exhibited a low detection limit (0.12 μM). Accordingly, the proposed electrode can serve as a simple and inexpensive electrochemical sensor for levosimendan detection.  相似文献   

3.
  相似文献   

4.
This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1 g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69–97% (except for thiophanate-methyl and carbofuran, which were 53–63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320–4.66 μg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.  相似文献   

5.
A novel electrochemical sensor for para-nitrophenol (p-NP) was constructed with graphene–Au composite containing 10 % Au (G–Au 10 %). In the composite, Au nanoparticles with the size of ca. 11 nm were regularly scattered on graphene sheet without aggregation, which offers dramatically higher electrocatalytic activity on the redox of K3[Fe(CN)6]/K4[Fe(CN)6] couple than sole Au nanoparticles. Compared to sole Au nanoparticles, the G–Au 10 % also exhibited dramatically improved electrocatalytic activity on the reduction of p-NP. Amperometric detection of p-NP at G–Au 10 % modified electrode displayed a wide linear range of 0.47–10.75 mM with detection limit of 0.47 μM and a high sensitivity of 52.85 μA/mM. Considering the thrifty in utilization of noble Au, the G–Au 10 % can be successfully applied as a low-cost and powerful sensing material for trace detection of p-NP.  相似文献   

6.
Ionic liquids extend the Hofmeister series and create a wide range of new possibilities for processes involving salt effects on both soluble and crosslinked systems. This work reports on some mixtures of water with NaCl or an ionic liquid, either 1-ethyl-3-methylimidazolium tosylate or 1-hexyl-3-methylimidazolium chloride, which are better solvents for linear poly(N-vinylimidazole) (L-PVI) than water, i.e., that exhibit a salting-in effect. The intensity of the salt effects was measured on the basis of the polymer solubility, the decrease in polymer–solvent interaction parameter (measured by light scattering), and the increase of coil size (measured through the intrinsic viscosity). It was thus found that the intensity of the salting-in effect of either NaCl or 1-hexyl-3-methylimidazolium chloride on L-PVI is different (larger for the ionic liquid), which denotes that salt effects are not under anion control, and the mechanisms operating in the linear and crosslinked polymers are different. These results are discussed after accounting for the role of ion–polymer interactions.  相似文献   

7.
A new method has been developed for liquid–liquid microextraction utilizing a circulation microchannel. A glass microchemical chip having a circular shallow microchannel in contact with a surrounding deeper microchannel was fabricated by a two-step photolithographic wet-etching technique. Surface modification reagent was selectively introduced to the shallow channel by utilizing capillary force, and the surface of the shallow channel was selectively made hydrophobic. With the aid of the hydrophobic/hydrophilic surface patterning, it was possible to keep organic solvent in the circular channel while the aqueous sample solution was continuously flowing in the deep channel. As a result, concentration extraction from sample solution to stationary extractant with a nanoliter scale volume became possible. Concentration extraction has been difficult in a multiphase continuous flow. Function of the newly developed microextraction system was verified with methyl red as a test sample, and concentration extraction to reach equilibrium was successfully carried out. A novel surface modification method utilizing frozen liquid as a masking material was also developed as a reverse process to make the shallow channel hydrophilic and the deep channel hydrophobic. Visualization of circulation motion inside the circular shallow channel induced by flow in the deep channel was observed with a particle tracing method.  相似文献   

8.
A biosensor was fabricated to detect pesticides in food samples. Acetylcholinesterase was immobilized in a novel fenugreek hydrogel–agarose matrix with gold nanoparticles. Transparent thin films with superior mechanical strength and stability were obtained with 2% fenugreek hydrogel and 2% agarose. Immobilization of acetylcholinesterase on the membrane resulted in high enzyme retention efficiency (92%) and a significantly prolonged shelf life of the enzyme (half-life, 55 days). Transmission electron microscopy revealed that, gold nanoparticles (10–20 nm in diameter) were uniformly dispersed in the fenugreek hydrogel–agarose–acetylcholinesterase membrane. This immobilized enzyme-gold nanoparticle dip-strip system detected various carbamates, including carbofuran, oxamyl, methomyl, and carbaryl, with limits of detection of 2, 21, 113, and 236 nM (S/N = 3), respectively. Furthermore, the fabricated biosensor exhibited good testing capabilities when used to detect carbamates added to various fruit and vegetable samples.  相似文献   

9.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (IL-USA-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for the extraction and preconcentration of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from three different water matrices. The procedure was based on a ternary solvent system containing tiny droplets of ionic liquid (IL) in the sample solution formed by dissolving an appropriate amount of the IL extraction solvent 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]) in a small amount of water-miscible dispersive solvent (methanol). An ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution, which markedly increased the extraction efficiency and reduced the equilibrium time. Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvents, ionic strength, pH and extraction time) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 354–464, and good repeatability of the extractions (RSDs below 6.3%, n = 5). The limits of detection were in the range of 0.2–5.0 ng mL−1, depending on the analytes. The linearities were between 1 and 500 ng mL−1 for BP, 5 and 500 ng mL−1 for BP-3 and HMS and 10 and 500 ng mL−1 for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in river, swimming pool and tap water samples and acceptable relative recoveries over the range of 71.0–118.0% were obtained.  相似文献   

10.
Nanostructured Fe2O3–graphene composite was successfully fabricated through a facile solution-based route under mild hydrothermal conditions. Well-crystalline Fe2O3 nanoparticles with 30–60?nm in size are highly encapsulated in graphene nanosheet matrix, as demonstrated by various characterization techniques. As electrode materials for supercapacitors, the as-obtained Fe2O3–graphene nanocomposite exhibits large specific capacitance (151.8?F?g?1 at 1?A?g?1), good rate capability (120?F?g?1 at 6?A?g?1), and excellent cyclability. The significantly enhanced electrochemical performance compared with pure graphene and Fe2O3 nanoparticles may be attributed to the positive synergetic effect between Fe2O3 and graphene. In virtue of their superior electrochemical performance, they will be promising electrode materials for high-performance supercapacitors applications.  相似文献   

11.
12.
Ultrasound-assisted dispersive liquid–liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5–500 μg mL−1 (octopamine and tyramine) and 0.025–2.5 μg mL−1 (phenethylamine). The relative standard deviations were 2.4–3.2% (n = 6) and the limits of detection were in the range of 0.02–5 ng mL−1. The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42–104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid–liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.  相似文献   

13.
A novel free radical reaction combined with liquid chromatography electrospray ionization tandem mass spectrometry (FRR-LC–PDA-ESI/APCI-MS/MS) screening method was developed for the detection and identification of radical-scavenging natural antioxidants. Functionalized graphene was prepared by chemical method for loading free radicals (superoxide radical, peroxyl radical and PAHs free radical). Separation was performed with and without a preliminary exposure of the sample to specific free radicals on the functionalized graphene, which can facilitate reaction kinetics (charge transfers) between free radicals and potential antioxidants. The difference in chromatographic peak areas is used to identify potential antioxidants. The structure of the antioxidants in one sample (Swertia chirayita) is identified using MS/MS and comparison with standards. Thirteen compounds were found to possess potential antioxidant activity, and their free radical-scavenging capacities were investigated. The thirteen compounds were identified as 1,3,5-trihydroxyxanthone-8-O-β-d-glucopyranoside (PD1), norswertianin (PD2), 1,3,5,8-tetrahydroxyxanthone (PD3), 3, 3′, 4′, 5, 8-penta hydroxyflavone-6-β-d-glucopyranosiduronic acid-6′-pentopyranose-7-O-glucopyranoside (PD4), 1,5,8-trihydroxy-3-methoxyxanthone (PD5), swertiamarin (PS1), 2-C-β-d-glucopyranosyl-1,3,7-trihydroxylxanthone (PS2), 1,3,7-trihydroxylxanthone-8-O-β-d-glucopyranoside (PL1), 1,3,8-trihydroxyl xanthone-5-O-β-d-glucopyranoside (PL2), 1,3,7-trihydroxy-8-methoxyxanthone (PL3), 1,2,3-trihydroxy-7,8-dimethoxyxanthone (PL4), 1,8-dihydroxy-2,6-dimethoxy xanthone (PL5) and 1,3,5,8-tetramethoxydecussatin (PL6). The reactivity and SC50 values of those compounds were investigated, respectively. PD4 showed the strongest capability for scavenging PAHs free radical; PL4 showed prominent scavenging capacities in the lipid peroxidation processes; it was found that all components in S. chirayita exhibited weak reactivity in the superoxide radical scavenging capacity. The use of the free radical reaction screening method based on LC–PDA-ESI/APCI-MS/MS would provide a new approach for rapid detection and identification of radical-scavenging natural antioxidants from complex matrices.  相似文献   

14.
The platinum nanoparticles-reduced graphene oxide-multi-walled carbon nanotubes composite (PtNPs-rGO-MWCNTs) has been synthesised by one-step chemical co-reduction strategy in ethylene glycol (EG) system using sodium citrate as reducing agent. The X-ray powder diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), as well as the electrochemical methods have been used for the characterisation of this composite. Benefiting from the large effective surface and good carrier function of rGO-MWCNTs, PtNPs in this nanocomposite have some excellent characteristics such as small particle size, good dispersion, as well as high electrocatalytic activity. Based on this, a new electrochemical sensor for hydrazine has been fabricated using dropping method. Under the optimum conditions, the linear range for the determination of hydrazine by amperometry at 0.20 V (vs. SCE) in phosphate buffer (pH 7.0) is from 2.0 × 10?7 mol L?1 to 2.3 × 10?3 mol L?1. The detection limit and sensitivity is 4.5 × 10?8 mol L?1 (S/N = 3) and 219.7 μA mM?1, respectively. This sensor has some attractive analytical features such as low detection limit, wide linear range, high sensitivity, as well as good stability.  相似文献   

15.
The ever-increasing complexity of industrial product recycling calls for more efficient purification processes such as liquid–liquid (L/L) extraction. Because of the high complexity of L/L extraction, optimizing a large-scale extraction is both time and resource consuming and can only be justified to solve high volume and value purification problems. It is therefore difficult to apply to small scale and highly variable waste material influx. We believe using a fully automated and integrated microfluidic approach will enable fast and cost-effective studies of L/L extraction processes. This review presents an overview of L/L metal extraction performed using microfluidics platforms. We first give an overview of the extraction methods. We then review the most relevant characterization methods integrated with such platforms.  相似文献   

16.
《Fluid Phase Equilibria》2004,216(1):175-182
An automated apparatus developed for the determination of liquid–liquid and solid–liquid equilibrium temperatures with a resolution of 1 mK and a traceable accuracy of 0.01 K is described. The amount of light transmitted through six sample cells placed in a computer controlled thermostat is recorded at heating or cooling rates from 0.075 to 15 K h−1. The construction does not require expensive optic equipment like lasers, glass fibre optics or photomultipliers, but is based on light emitting diodes (LED) as light sources and light dependent resistors (LDR) or photodiodes as detectors. As shown by the discussed examples, the instrument has a wide range of possible applications from the investigation of simple one-component and binary systems to the study of the complicated phase behavior of surfactant solutions.  相似文献   

17.
《Solid State Sciences》2012,14(2):276-280
In this paper, graphene–cuprous oxide (G–Cu2O) composites were synthesized at room temperature using graphene oxide (GO) as two-dimensional support. From Zeta potential analysis, the surface charge of G–Cu2O composites altered from positive to negative, which favors the adsorption and photodegradation of positively charged dyes. Compared with Cu2O under similar synthesis condition, the G–Cu2O composites demonstrated improved photodegradation activity for methylene blue (MB) dye under visible light. Controlled experiments indicated that the G–Cu2O composite synthesized with 80 mg GO in the reaction system possessed more negative Zeta potential, highest specific surface area and thus presented the highest photocatalytic activity. Electrons mechanism for the improved photocatalytic performance of G–Cu2O composite was proposed in the degradation of MB.  相似文献   

18.
This work compares the performance of dispersive liquid–liquid method (DLLME) as a prior step for determining copper by flame atomic absorption spectrometry (FAAS), when using the ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate (C4MIm-PF6) or the IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16C4Im-Br) as extractant solvents. For the water-insoluble C4MIm-PF6, the most conventional DLLME mode using acetonitrile as dispersive solvent was employed. For the water-soluble C16C4Im-Br, the in situ DLLME mode with lithium bis[(trifluoromethane)sulfonyl]imide (Li-NTf2) as metathesis reagent was employed. In both approaches, some effective parameters such as volumes of extractant and dispersive solvents, concentration of complexing agent, pH of sample solution, salting-out effect and final diluting solvent to ensure compatibility with FAAS, were properly optimised. The optimum conditions for the IL-DLLME method using C4MIm-PF6 were: 100 μL of neat C4MIm-PF6, 1 mL of acetonitrile, 10 mL of water, no control of pH for environmental waters, NaCl content of 23 g L?1, diethyl dithiocarbamate (DDTC) as complexing agent at 10 mg L?1 and final dilution of the micro-droplet with acetonitrile up to 70 µL. The optimum conditions for the in situ IL-DLLME method using C16C4Im-Br were: 0.8 mL of acetonitrile, 10 mL of water containing C16C4Im-Br at 25.2 mmol L?1, final dilution step of the micro-droplet with 200 µL of acetonitrile and remaining conditions as those of C4MIm-PF6. The analytical performance of both methods was similar, being slightly better for the IL-DLLME method using C4MIm-PF6, with limits of detection (LOD) of 3.3 µg L?1 (versus 5.1 µg L?1 when using C16C4Im-Br), precision values as intraday relative standard deviation (RSD in %) lower than 8.8% (being of 10% for the C16C4Im-Br method) and an enrichment factor of 54 (being 27 when using C16C4Im-Br). The DLLME-FAAS method with C4MIm-PF6 was used in the analysis of environmental waters with successful performance, with relative recoveries of 110% and 105%, and interday precision with RSD values of 21% and 7.4% for spiked levels of 60 and 160 µg L?1, respectively. The results obtained when analysing an urban wastewater sample coming from an inter-laboratory exercise was comparable to those obtained for other 93 laboratories. The method was also valid for the determination of Cu2+ in presence of foreign ions commonly found in natural waters.  相似文献   

19.
Resolving components and determining their pseudo-molecular ions (PMIs) are crucial steps in identifying complex herbal mixtures by liquid chromatography–mass spectrometry. To tackle such labor-intensive steps, we present here a novel algorithm for simultaneous detection of components and their PMIs. Our method consists of three steps: (1) obtaining a simplified dataset containing only mono-isotopic masses by removal of background noise and isotopic cluster ions based on the isotopic distribution model derived from all the reported natural compounds in dictionary of natural products; (2) stepwise resolving and removing all features of the highest abundant component from current simplified dataset and calculating PMI of each component according to an adduct-ion model, in which all non-fragment ions in a mass spectrum are considered as PMI plus one or several neutral species; (3) visual classification of detected components by principal component analysis (PCA) to exclude possible non-natural compounds (such as pharmaceutical excipients). This algorithm has been successfully applied to a standard mixture and three herbal extract/preparations. It indicated that our algorithm could detect components’ features as a whole and report their PMI with an accuracy of more than 98%. Furthermore, components originated from excipients/contaminants could be easily separated from those natural components in the bi-plots of PCA.  相似文献   

20.
A powerful preconcentration method for nonylphenol (NP) has been developed for liquid-chromatography by combining the use of cellulose cotton (solid-phase extraction) with homogeneous liquid–liquid extraction. A 100 ml of sample solution was preconcentrated using cotton, and the eluate obtained (acetonitrile; 5 ml) was further preconcentrated to 50 l within 10 min using a homogeneous liquid–liquid extraction method (volume ratio, 2,000-fold; 100 ml 50 l). The sample concentration increases from preconcentration was 1,599-fold, and NP was extracted into the sedimented phase at 80%. The proposed method was applied to high performance liquid chromatography with fluorescence detection (FL/HPLC); the lowest determination limit obtained was 1.0×10–9 mol l–1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号