首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A sensitive aptamer-based sandwich-type sensor is presented to detect human thrombin using quantum dots as electrochemical label. CdSe quantum dots were labeled to the secondary aptamer, which were determined by the square wave stripping voltammetric analysis after dissolution with nitric acid. The aptasensor has a lower detection limit at 1 pM, while the sample consumption is reduced to 5 μl. The proposed approach shows high selectivity and minimizes the nonspecific adsorption, so that it was used for the detection of target protein in the human serum sample. Such an aptamer-based biosensor provides a promising strategy for screening biomarkers at ultratrace levels in the complex matrices.  相似文献   

2.
An ultra-sensitive and highly selective electrochemical label-free aptasensor is proposed for the quantitation of Hg2 + based on the hybridization/dehybridization of double-stranded DNA (dsDNA) on a gold electrode. Thiol-substituted single-stranded DNA (ssDNA) is self-assembled on the gold electrode surface through the SAu interaction. The hybridization of ssDNA with complementary DNA (cDNA) and the consequences of dehybridization in the presence of mercury ions are followed through differential pulse voltammetry (DPV) responses using a [Fe(CN)6]3 −/4  redox probe. The formation of a thymine–Hg2 +–thymine (T–Hg2 +–T) complex is the key to producing a highly selective and sensitive aptasensor for Hg2 + determination. Specifically, the present electrochemical aptasensor is able to quantify Hg2 + ions in concentrations from 5 zeptomolar (zM) to 55 picomolar (pM) with a limit of detection of 0.6 zM, close to the dream of single atom detection, without requiring a complicated procedure or expensive materials.  相似文献   

3.
The construction of an ultrasensitive, reagentless, target label free electrochemical aptamer sensor (aptasensor) for thrombin detection is described. The aptasensor is based on a chronoamperometric beacon system for biomolecular recognition. The ferrocene-labeled aptamer adopts a 3-D conformational change when interacts with thrombin. Thus the ferrocene label is approached to the microperoxise-11 (MP-11) attached on the electrode surface. The thrombin–aptamer interaction is detected via a microperoxidase mediated electron transfer between the ferrocene and the surface. This system was demonstrated with surface plasmon resonance, impedance spectroscopy and chronoamperometry measurements, obtaining higher sensitivity (30 fM) with impedance spectroscopy.  相似文献   

4.
A novel and ultrasensitive sandwich-type electrochemical aptasensor has been developed for the detection of thrombin, based on dual signal-amplification using HRP and apoferritin. Core/shell Fe3O4/Au magnetic nanoparticles (AuMNPs) loading aptamer1 (Apt1) was used as recognition elements, and apoferritin dually labeled with Aptamer2 (Apt2) and HRP was used as a detection probe. Sandwich-type complex, Apt1/thrombin/Apt2–apoferritin NPs–HRP was formed by the affinity reactions between AuMNPs–Apt1, thrombin, and Apt2–apoferritin–HRP. The complex was anchored on a screen-printed carbon electrode (SPCE). Differential pulse voltammetry (DPV) was used to monitor the electrode response. The proposed aptasensor yielded a linear current response to thrombin concentrations over a broad range of 0.5–100 pM with a detection limit of 0.07 pM (S/N = 3). The detection signal was amplified by using apoferritin and HRP. This nanoparticle-based aptasensor offers a new method for rapid, sensitive, selective, and inexpensive quantification of thrombin, and offers a promising potential in protein detection and disease diagnosis.  相似文献   

5.
6.
For the first time silicon carbide nanoparticles (SiC) was used for electrode modification and electrocatalytic oxidation of insulin. In comparison to bare glassy carbon (GC) electrode, the oxidation of insulin at GC electrode modified with SiC nanoparticles occurred at reduced overpotentials. The modified electrode was applied for insulin detection using cyclic voltammetry, differential pulse voltammetry (DPV) and flow injection analysis (FIA). Flow injection amperometric determination of insulin at this modified electrode yielded a calibration curve with the following characteristics; linear dynamic range up to 600 pM, sensitivity of 710 pA pM?1 cm?2 and detection limit of 3.3 pM. In addition interference effect of the electroactive existing species (uric acid, glucose, lactic acid, l-cysteine and cholesterol) was diminished and for ascorbic acid eliminated by covering the surface of modified electrode with nafion film. This electrode shows many advantages as an insulin sensor such as simple preparation method without using any specific electron transfer mediator or specific reagent, high sensitivity, excellent catalytic activity, short response time, long term stability and remarkable antifouling property toward insulin and its oxidation product. Sensitivity, detection limit and antifouling properties of this insulin sensor are better than all of the reports in the literature for insulin detection at physiological pH solutions.  相似文献   

7.
A disposable sensor for the determination of cotinine in human serum was developed based on immunochromatographic test strip and quantum dot label. In this assay, cotinine linked with quantum dot competes with cotinine in sample to bind to anti-cotinine antibody in the test strip and the quantum dots serve as signal vehicles for electrochemical readout. Some parameters governing the performance of the sensor were optimized. The sensor shows a wide linear range from 1 ng mL?1 to 100 ng mL?1 cotinine with a detection limit of 1.0 ng mL?1. The sensor was validated with spiked human serum samples and it was found that this method was reliable in measuring cotinine in human serum. The results demonstrate that this sensor is rapid, accurate, and less expensive and has the potential for point of care (POC) detection of cotinine and fast screening of tobacco smoke exposure.  相似文献   

8.
A dynamic liquid phase microextraction (LPME) system, based on hollow-fibre supported liquid membrane (SLM) extraction, was developed for extracting ionisable xenobiotics from human plasma, and its performance was evaluated (in terms of extraction efficiency, reproducibility, durability and carry-over) using nitrophenolic compounds as model analytes at concentrations of 0.1–0.5 μg mL?1 in aqueous standards. The efficiency and repeatability were tested also on spiked human plasma. The system is non-expensive, convenient, requires minimal manual handling and enables samples with volumes as small as 0.2 mL to be extracted. For plasma samples extraction efficiencies of between 30 and 58% were achieved within 20 min, including washing steps. The limit of detection (LOD) values were in the range 0.02–0.03 μg mL?1. The developed system can provide enrichment factors up to eight, based on the injection-to-acceptor volume ratio (in this case 0.2–0.025 mL). The same hollow-fibre membrane was used up to 8 days with no loss of efficiency. Carry-over was lower than detection limit.  相似文献   

9.
Recently, molecular imprinted polymers (MIPs) were extensively used for separation and identification of specific molecules, replacing expensive and unstable biological receptors. Nonetheless, their application in electrochemical sensors has not been sufficiently explored. Here we report the use of a MIP as a specific receptor in a new highly sensitive tributyltin (TBT) electrochemical sensor. The sensor combines the specificity, pre-concentration capability and robustness of molecular imprinted polymer attached onto magnetic nanoparticles with the quantitative outputs of impedimetric measurements. The proposed device detects TBT in a concentration range of 5 pM to 5 μM with a low limit of detection (5.37 pM), which is lower than the one recommended for TBT in sea water by the US Environmental Protection Agency (EPA). We believe that this new electrochemical sensor can play an important role in the monitoring of the quality of sea and fresh waters worldwide.  相似文献   

10.
We describe a quantum-dot (QD, CdSe@ZnS) based electrochemical immunoassay to detect a protein biomarker, interleukin-1α (IL-1α). QD conjugated with anti-IL-1α antibody was used as a label in an immunorecognition event. After a complete sandwich immunoreaction among the primary IL-1α antibody (immobilized on the avidin-modified magnetic beads), IL-1α, and the QD-labeled secondary antibody, QD labels were attached to the magnetic-bead surface through the antibody-antigen immunocomplex. Electrochemical stripping analysis of the captured QDs was used to quantify the concentration of IL-1α after an acid-dissolution step. The streptavidin-modified magnetic beads and the magnetic separation platform were used to integrate a facile antibody immobilization (through a biotin/streptavidin interaction) with immunoreactions and the isolation of immunocomplexes from reaction solutions in the assay. The voltammetric response is highly linear over the range of 0.5–50 ng ml−1 IL-1α, and the limit of detection is estimated to be 0.3 ng ml−1 (18 pM). This QD-based electrochemical immunoassay shows great promise for rapid, simple, and cost-effective analysis of protein biomarkers.  相似文献   

11.
We describe an ultrasensitive electrochemical detection of DNA protocol based on the isothermal strand-displacement polymerase reaction (ISDPR) and enzyme dual amplifications. Target DNA triggered an ISDPR to produce numerous bi-functionalized duplex DNA complexes. Following an immuno-magnetic collection via an immunoreaction between the attached digoxin on the duplex DNA and the anti-digoxin antibody on the magnetic bead, horseradish (HRP) tracers were bound to the duplex DNA through a biotin–streptavidin interaction. The quantification of DNA was realized by square wave voltammetric detection of the enzymatic products with a screen-printed gold electrode. The voltammetric response was proportional to the concentration of DNA in the range of 0.1 fM–0.5 pM, and the limit of detection was estimated to be 0.06 fM. The new protocol showed great promise for simple, cost-effective, and quantitative gene analysis.  相似文献   

12.
A simple, rapid and low-cost electroanalytical method is proposed for the determination of acetaminophen (ACP) and codeine (COD) at nanomolar levels in pharmaceutical and biological samples. The analytical procedure is based on a flow injection analysis system coupled to electrochemical detection, which was multiple pulse amperometry (FIA-MPA). Boron-doped diamond was used as the working electrode for electrochemical detection. The electrode was subjected to a cathodic pretreatment and was selected in this work due its good electrochemical performance. By applying the FIA-MPA method, after a number of optimization assays, the analgesics were simultaneously determined at excellent linear concentration ranges. The analytical curves ranged from 80 nmol L−1 to 100 µmol L−1 for ACP and from 50 nmol L−1 to 10 µmol L−1 for COD, and the obtained limits of detection were 30 nmol L−1 and 35 nmol L−1 for ACP and COD, respectively. The practical applicability of the electroanalytical method was evaluated from the ACP and COD determination in two sample matrices: commercial pharmaceutical samples and biological fluids. In the case of pharmaceutical formulation samples, the obtained results were statistically similar to those obtained using a reference chromatographic method. In addition, these drugs were simultaneously quantified in biological fluid samples of urine and human serum with excellent recovery percentages.  相似文献   

13.
Vertical arrays of one-dimensional tin nanowires on silicon dioxide (SiO2)/silicon (Si) substrates have been developed as anode materials for lithium rechargeable microbatteries. The process is complementary metal-oxide-semiconductor (CMOS) compatible for fabricating on-chip microbatteries. Nanoporous anodized aluminum oxide (AAO) templates integrated on SiO2/Si substrates were employed for fabrication of tin nanowires resulting in high surface area of anodes. The microstructure of these nanowire arrays was investigated by scanning electron microscopy and X-ray diffraction. The electrochemical tests showed that the discharge capacity of about 400 mA h g−1 could be maintained after 15 cycles at the high discharge/charge rate of 4200 mA g−1.  相似文献   

14.
In this stability-indicating, reversed-phase high-performance liquid chromatographic method for nicardipine (NIC), forced degradation has been employed and the formed degradants were separated on a C18 (150 mm × 3.9 mm, 5 μm) analytical column using a mobile phase consisted of 70% methanol: acetic acid containing 0.01 M triethylamine with pH 4. The flow rate was 1.0 mL/min and the photodiode array detection wavelength was 353 nm. Forced degradation of the drug was carried out under acidic, basic, photolytic, and oxidative stress conditions. Chromatographic peak purity data indicated no co-eluting peaks with the main peaks. This method resulted in the detection of seven degradation products. Among these, two major degradation products from basic hydrolysis, one from oxidation by H2O2 and four from photolytic stress were identified by mass spectral data. A good linear response was achieved over the range of 0.5–40 μg/mL with a limit of detection (LOD) of 0.011 μg/mL and limit of quantification (LOQ) of 0.036 μg/mL. The suggested method was successfully applied for the analysis of NIC in its commercial capsules, with mean% recovery value of 100.11 ± 2.26%. The method was extended to the in vitro determination on NIC in spiked human plasma samples with mean% recovery of 99.04 ± 5.67%. The suggested method was utilized to investigate the kinetics of photolytic induced degradation.  相似文献   

15.
A novel procedure for trace methylmercury determinations by anodic stripping voltammetry at a gold film electrode is presented. Measurements were performed in a flow system. For selective determination of methylmercury, the Hg2+ ions were masked by complexation with DTPA. Hg-DTPA complex is not reduced at the gold film electrode at the potential of methylmercury reduction to the metallic state. The calibration graph was linear from 5 × 10−9 to 1 × 10−7 mol L−1 for an accumulation time 600 s. A detection limit (based on 3σ criterion) for methylmercury was 2.3 × 10−9 mol L−1. The validation of the proposed procedure was made by analyses of human hair certified reference material.  相似文献   

16.
A novel chitosan-carboxylated multiwall carbon nanotube modified glassy carbon electrode (MC/GCE) was developed to investigate the oxidation behavior of nitrite using cyclic voltammetry and differential pulse voltammetry modes. The electrochemical mechanism of the MC/GCE towards nitrite was discussed. The MC/GCE exhibited fast response towards nitrite with a detection limit of 1 × 10−7 mol l−1 and a linear range of 5 × 10−7–1 × 10−4 mol l−1. The possible interference from several common ions was tested. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   

17.
Human serum albumin (HSA) was the most abundant protein in human plasma and has significant physiological function. In Tris–HCl buffer solution (pH 7.4), water-soluble semiconductor CdSe quantum dots (QDs) reacted with HSA and the products resulted in a great enhancement of the intensity of resonance Rayleigh scattering (RRS) and second-order scattering (SOS). Based on this, a new method was developed to investigate the interactions between QDs and HSA. The parameters with regard to determination were optimized, and the reaction mechanism was discussed. Under optimal conditions, the increments of scattering intensity (ΔI) were directly proportional to the concentrations of HSA in the range of 0.4–48.0 μmol L?1. The detection limits were 0.10 μmol L?1 for RRS method and 0.25 μmol L?1 for SOS method. The proposed method was sensitive, simple and rapid. It has been successfully applied to the determination of HSA in human urine samples. Analytical results obtained with this novel assay were satisfactory.  相似文献   

18.
Lead is the non-essential trace element in the human body, and it has been confirmed that drinking water is one of the sources of lead in human body. In the research, based on the sensitive colour reaction of lead with I?–EV+–PVA, a simple, sensitive, accurate and portable method for the determination of trace lead in drinking waters was proposed. Chemicals and physicals had been optimized in detail. The apparent molar absorption coefficient was up to 7.4 × 105 mol L?1 cm?1. The developed method provided a linearity range over 5–80 μg L?1. The regression deviation was between 0.71% and 2.33%. The 3σ detection limit was 0.9 μg L?1. Close to the quantitation limit for the analyte the relative standard deviation was 1.10% (n = 10) at 40 μg L?1. The method developed here for analysis of lead yielded results that were comparable with those of the GFAAS.  相似文献   

19.
Electrochemical immunosensors based on single wall nanotube (SWNT) forests and 5 nm glutathione-protected gold nanoparticles (GSH-AuNP) were developed and compared for the measurement of human cancer biomarker interleukin-6 (IL-6) in serum. Detection was based on sandwich immunoassays using multiple (14–16) horseradish peroxidase labels conjugated to a secondary antibody. Performance was optimized by effective blocking of non-specific binding (NSB) of the labels using bovine serum albumin. The GSH-AuNP immunosensor gave a detection limit (DL) of 10 pg mL?1 IL-6 (500 amol mL?1) in 10 μL calf serum, which was 3-fold better than 30 pg mL?1 found for the SWNT forest immunosensor for the same assay protocol. The GSH-AuNPs platform also gave a much larger linear dynamic range (20–4000 pg mL?1) than the SWNT system (40–150 pg mL?1), but the SWNTs had 2-fold better sensitivity in the low pg mL?1 range.  相似文献   

20.
N,N′-phenylenebis(salicylideaminato) (L) has been used to detect trace amounts of zinc ion in acetonitrile–water solution by fluorescence spectroscopy. The fluorescent probe undergoes fluorescent emission intensity enhancement upon binding to zinc ions in MeCN/H2O (1:1, v/v) solution. The fluorescence enhancement of L is attributed to the 1:1 complex formation between L and Zn(II), which has been utilized as the basis for selective detection of Zn(II). The linear response range for Zn(II) covers a concentration range of 1.6 × 10?7 to 1.0 × 10?5 mol/L, and the detection limit is 1.5 × 10?7 mol/L. The fluorescent probe exhibits high selectivity over other common metal ions, and the proposed fluorescent sensor was applied to determine zinc in water samples and waste water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号