首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 125 毫秒
1.
High quality ion beams are required by IMP cyclotron and atomic physics research, so it is important to research and measure beam emitt ance of ECR ion source. Intense beams extracted from ECR ion source usually have low energy, so it is suitable to use Electric-Sweep Scanner to measure the emittance. This kind of measurement is popularly used at ECR ion source, and it has some prominent merits such as high accuracy, very short time of data processing and easy expressing of the emittance pattern. So we designed and built this emittance scanner to measure emittance of the ion beams produced by LECR3 ion source. The structure of the ESS is shown in Fig.l, and the photo of the ESS is shown in Fig.2.  相似文献   

2.
为全面研究ECR(Electron Cyclotron Resonance)离子源引出的高电荷态离子束流品质,获取ECR离子源引出离子束流的横向四维相空间分布,提高向加速器的注入效率,中国科学院近代物理研究所研制了一台高精度Pepper Pot型发射度测量仪PEMiL(Pepper pot Emittance Meter in Lanzhou)。根据使用需求,利用KBr晶体喷涂技术取代传统的CsI闪烁体成像技术,解决了束流光斑重叠效应,获得了边界清晰的束流图像;并开发了相应的数据处理分析程序,以分析处理得到的束流横向四维相空间分布。利用PEMiL获得了75 keV,170 eμA的O5+束流横向四维发射度。分析结果表明:PEMiL测量分析后的束流发射度结果可靠性高,荧光屏电荷累积效应造成的发射度差异不超过25%,PEMiL可作为ECR离子源引出离子束流品质诊断的有效装置。  相似文献   

3.
In order to study the transmission properties of multi-charged ion beams between the ECR ion source and the analyzing magnet, a new diagnostic system composed of three Wien-filters with three single-wires has been built and installed on the IMP ECR source test bcnch. The single-wire is used to measure the beam profile and the beam density distribution, and the Wien-filter is used to measure the charge state distribution of ion beam.  相似文献   

4.
为了提高强流ECR 离子源的引出束流品质,分别设计了1# 和2# 引出系统,利用束流引出模拟软件PBGUNS 对1# 和2# 引出系统进行了质子束流引出与传输的模拟计算,结合实际测得的发射度数据分析引出系统,发现2# 引出系统比1# 引出系统引出束流品质高。对ECR 离子源引出系统的电势等位线分布等参数引起的球差进行了简单数学推导及MATLAB 绘图,并结合1# 和2# 引出系统束流相图模拟结果证明了球差会使引出束流品质有效发射度增长,通过适当加大电极孔径可改善束流聚焦情况,得到了束流光学聚焦较好的束流引出系统设计。To improve the quality of extracted ion beam from a high current ECR ion source, 1# and 2# extraction systems were designed and tested. The PBGUNS code was used to simulate the 1# and 2# extraction systems of proton ion beam. The emittance measurement results with the two different extraction systems were compared and analyzed with the simulation, the conclusion that more high quality beam extracted from 2# system than 1# system was got. The formula derivation of ECR ion source extraction system spherical aberration and MATLAB drawing was done by the analyzing on the distribution of extraction field equipotentials, effective emittance increasing caused by spherical berration was proved by 1# and 2# extraction systems beam phase space simulation result, beam focusing would be improved if electrode hole size increasing appropriately and a general concept on good optics focusing of ion beam extraction system was proposed finally.  相似文献   

5.
介绍了现阶段两种用于聚焦离子束系统的离子源——液态金属离子源和气体场发射离子源的基本原理, 并对比了它们的优缺点。由于目前这两种离子源都难以满足纳米加工领域不断提高的技术要求, 因此提出了一种用于聚焦离子束的新型离子源——电子束离子源, 并介绍了电子束离子源的基本原理, 给出了设计参数、 模拟结果(20 kV的Ar+离子束, 发射度约为5.8×10-5·mm·mrad, 束斑约为1 μm)和初步的实验结果。 There are two kinds of ion sources, Liquid Metal Ion Source and Gas Field Ion Source, used to provide ion beams for the Focus Ion Beam system. The working mechanism of the two kinds of sources is presented and their advantages and disadvantages are summarized. With the rapid development in the nano technology, the requirements are hardly met with these two kinds of ion sources. Therefore, a new kind of ion source, electron beam ion source, is developed for the Focus Ion Beam system. The basic principle of the electron beam ion source is introduced and the design parameters, the result of the simulation (20 kV Ar+, extracted emittance is 5.8×10-5π·mm·mrad, raduis of the ion beam about 1 μm.) and the primary experimental results are presented  相似文献   

6.
The Penning surface plasma source is adopted as the China Spallation Neutron Source (CSNS) H- ion source. The designed energy and beam current of the source are 50 keV and 20 mA, respectively, with a normalized root mean square (norm. rms.) emittance of 0.2 πmm·mrad. The construction of a H- ion source test stand has been completed, and the commissioning of the source is in progress. Stable H- ion beams with energy of 50 keV and current up to 50 mA are attained. Emittance measurement for the H- beam is being prepared.  相似文献   

7.
对于低能强流离子束来说,空间电荷效应的存在将导致束流发散、发射度增加等一系列问题,从而降低束流品质。幸运的是,当束流由离子源引出通过低能传输线时会与其中的剩余气体发生电离反应,产生二次电子与二次离子;二次电子在束流自身产生的电场作用下,在束流中积累并中和部分空间电荷,达到抑制空间电荷效应的效果。为了测量空间电荷中和程度,中国科学院近代物理研究所研制了一台三栅网式能量分析仪用以测量电离过程中产生的二次离子能量来间接计算空间电荷中和度。实验结果表明,对于40 keV, 18.5 mA的质子束,真空度为1.510*3 Pa 时得到最佳补偿度;真空度一定的情况下,空间电荷补偿度随束流流强增加而变大。For high-intensity low-energy ion beams, space charge effect is a main cause of beam divergence  and emittance growth. Fortunately, residual gas molecules in the drift space tend to be ionized and neutralize the beam space charge spontaneously. The level of Space Charge Neutralization (SCN)is measured through the detection of created secondary ion energy distribution in the beam region. A so-called non-interceptive Three-grid Energy Analyzer (TEA) has been designed and manufactured at Institute of Modern Physics, Chinese Academy of Sciences (IMP). This paper will present the detailsof the TEA detector and the application to diagnose proton beam SCN level in the Low Energy Beam Transport (LEBT) line. As a preliminary result, for an 18.5 mA proton beam a best compensating point appears at the vacuum pressure of 1.510*3 Pa. And the neutralization level is advanced with thegrowth of beam current in a constant vacuum pressure.  相似文献   

8.
高电荷态ECR离子源   总被引:1,自引:0,他引:1  
介绍了目前ECR离子源的发展状况和国际上几台典型的ECR离子源.Electron cyclotron resonance (ECR) ion source is the most efficient facility for producing highly charged ions. So far more than 1 emA of O 6+ and 0.02 eμA of U 55+ have been delivered by ECR ion source. In this paper the latest development of ECR ion source is presented and several typical ECR ion sources in the world is introduced.  相似文献   

9.
重离子束适形放射治疗技术   总被引:7,自引:5,他引:2  
重离子束适形放射治疗技术主要包括束流配送系统和治疗计划系统等 .前者是实现重离子束适形放射治疗的硬件设施 ,后者为适形治疗的软件支撑系统 ,两者缺一不可 .鉴于重离子束与物质相互作用在物理学及生物学效应上表现出的特殊性,重离子束治癌中特别引入了面向生物学效应的适形治疗和束流的正电子断层在线监控技术. The conformal radiotherapy techniques mainly include the two systems that are beam delivery and treatment planning. The formal is the hardware basis while the later is the software supplement for heavy ion conformal therapy, they are dependent on each other to realize the cancer conformal therapy with heavy ion beam. Because of the specificities of interaction between heavy ion and target on both physics and biological effects, the heavy ion cancer therapy especially involves...  相似文献   

10.
A new H- ion source has been installed successfully and will be used to serve the China Spallation Neutron Source (CSNS). In this paper, we report various components of the ion source, including the discharge chamber, temperature, cooling system, extraction electrodes, analyzing magnet, remote control system and so on. Compared to the previous experimental ion source, some improvements have been made to make the ion source more compact and convenient. In the present arrangement, the Penning field is generated by a pair of pole tip extensions on the 90° analyzing magnet instead of by a separate circuit. For the remote control system, F3RP61-2L is applied to the accelerator online control system for the first time. In the running of the ion source, a stable pulse H- beam with a current of 50 mA at an energy of 50 keV is produced. The extraction frequency and pulse width is 25 Hz and 500 μs, respectively. Furthermore, an emittance scanner has been installed and measurements are in progress.  相似文献   

11.
利用最新自行研制的电扫描发射度探测系统, 在ECR离子源上进行了一系列关于ECR离子源引出束流发射度的研究. 这套电扫描发射度探测系统安装在中国科学院近代物理研究所(兰州)的LECR3试验平台的束运线上. 试验中, 通过测量相关参数, 研究了磁场、微波、掺气效应及负偏压效应等对引出束流发射度的影响. 利用实验所得的结果与关于ECR等离子体和离子源束流发射度的半经验理论, 分析推导了离子源各可调参数与ECR等离子体的直接关系, 这为分析探索ECR离子源的工作机制提供了一定的参考依据.  相似文献   

12.
13.
The Coupled Cyclotron Facility (CCF) has been operating at the NSCL since 2001,providing up to 160MeV/u heavy ion beams for nuclear physics experiments.Recent steps,particularly the improvement of the ECR-to-K500 injection line,were taken to improve the CCF performance.For that purpose an off-line ECR source,ARTEMIS-B,was built and used to investigate the impact on beam brightness under various source operating conditions,different initial focusing systems and current analysis dipole.Beam dynamics simulations including space-charge and 3D electrostatic field effects were performed and beam diagnostics including emittance scanner were used,leading to a better understanding of the CCF beam injection process. New initial electrostatic focusing elements such as a large-bore quadrupole triplet and a quadrupole double- doublet with compensating octupole were tested,and a new beam tuning procedure was established to improve the beam brightness for the CCF.Following these efforts,a significant increase of primary beam power out of the CCF has been achieved.  相似文献   

14.
为满足国家大科学工程兰州重离子冷却储存环的要求,在14.5GHz ECR 离子源上进行afterglow工作模式的实验,首次产生了高电荷态脉冲束流Ar11+和Ar12+,给出了初步实验结果,并对结果进行了分析和解释.  相似文献   

15.
The Rare Isotope Accelerator (RIA) facility includes a driver LINAC for production of 400 kW CW heavy-ion beams. The initial acceleration of heavy ions delivered from an ECR ion source can be effectively performed by a 57.5 MHz 4 m long RFQ. The principal specifications of the RFQ are: (1) formation of extremely low longitudinal emittance: (2) stable operation over a wide range of voltage for acceleration of various ion species needed for RIA operation; (3) simultaneous acceleration of two-charge states of uranium ions. CW operation of an accelerating structure leads to a number of requirements for the resonators such as high shunt impedance, efficient water cooling of all parts of the resonant cavity, mechanical stability together with precise alignment, reliable rf contacts, a stable operating mode and fine tuning of the resonant frequency during operation. To satisfy these requirements a new resonant structure has been developed. This paper discusses beam dynamics and electrodynamics design of the RFQ cavity, as well as, some aspects of the mechanical design of this low-frequency CW RFQ.  相似文献   

16.
研制成功了一台新的高电荷态ECR离子源,该离子源主要为原子物理实验提供各种高电荷态离子束流,是基于中国科学院近代物理研究所14.5GHz高电荷态ECR离子源设计建成的,同时在该离子源中应用多种有利于提高束流强度的技术,设计时考虑到采用双频加热,试图通过试验双频加热模式来提高高电荷态离子的产额,并设计建造了一套束流聚焦分析系统,以提高电荷态分辨率和束流传输效率.  相似文献   

17.
加速器驱动次临界系统注入器Ⅰ,包括ECR离子源、低能传输线、射频四极加速单元、中能传输段和超导腔,注入器Ⅰ出口能够获得能量10 MeV的强流质子束流。为了调束和运行的需要,注入器Ⅰ将安装束流位置测量、束流截面测量、束流流强测量、束流发射度和能量测量,以及束流损失测量等束流参数测量装置。介绍了这些束流测量系统设计及其他方面的一些考虑。  相似文献   

18.
An ECR ion source for charge breeding of radioactive ions from the ISAC facility at TRIUMF has been set up at a test stand.It has been operated with different ion sources for the injection of singly charged ions and the efficiency,breeding time and emittance have been determined for several elements.A maximum efficiency of more than 6% for the breeding of Kr~(12 ) has been achieved so far.Additionally the charge exchange of Rb and Cs ions in the range of 10 to 23 with residual gas molecules in the transport beam lines has been investigated.The absolute values for the cross sections at 10—15 q keV agree with predictions extrapolated from lower charge states but the strong dependence on the ionization energy of the gas molecules could not be verified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏