首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Theoretical and empirical models can be used to model the migration or separation characteristics in micellar electrokinetic chromatography in order to optimise the resolution. In this paper only empirical models were used, because it is easier and more straightforward to obtain these models. Several empirical approaches for the optimisation of the resolution were compared in order to determine which response should be modelled preferably. The use of models of the effective mobility in combination with average plate numbers proved to be the most suitable approach to optimisation of the resolution, because the relative prediction errors of the models of the effective mobility were a factor of 2-4 smaller than the relative prediction errors of the models of the apparent mobility. Moreover for the least separated peak pair the resolutions based on the models of the apparent and effective mobility showed relative prediction errors that were approximately a factor of 2 smaller than the relative prediction errors of the resolutions based on the models of the resolution and separation factor. The predictions of the separation factor based on the different models generally showed lower prediction errors than the predictions of the corresponding resolutions. Although the relative prediction errors were large, particularly for closely migrating compounds, the empirical approach will probably lead to the optimum separation buffer composition.  相似文献   

2.
The separation process in capillary micellar electrochromatography (MEKC) can be modelled using artificial neural networks (ANNs) and optimisation of MEKC methods can be facilitated by combining ANNs with experimental design. ANNs have shown attractive possibilities for non-linear modelling of response surfaces in MEKC and it was demonstrated that by combining ANN modelling with experimental design, the number of experiments necessary to search and find optimal separation conditions can be reduced significantly. A new general approach for computer-aided optimisation in MEKC has been proposed which, because of its general validity, can also be applied in other separation techniques.  相似文献   

3.
In this study, microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) were compared for their abilities to separate and detect thirteen phenolic compounds (syringic acid, p-coumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), and two other ingredients (caffeine and theophylline) in teas and grapes. Separation of phenolic compounds was improved by changing the SDS concentration for MEEKC, but the SDS concentration rarely affected the resolution for MEKC. Organic modifier (acetonitrile or methanol) was found to markedly influence the resolution and selectivity for both MEEKC and MEKC systems. In addition, a higher voltage and a higher column temperature improved the separation efficiency without any noticeable reduction in resolution for MEEKC whereas they caused a poor resolution for the MEKC system. Although separations with baseline resolution were achieved by the optimized MEEKC and MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC.  相似文献   

4.
Huang HY  Chiu CW  Chen YC  Yeh JM 《Electrophoresis》2005,26(4-5):895-902
Microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatograpy (MEKC) were compared for their abilities to separate and detect ten similar benzophenones, which are commonly used as UV filters in various plastic and cosmetic products. Sodium dodecyl sulfate (SDS) concentration and column temperature rarely affected separation resolution for MEEKC, but separation of benzophenones could be improved by changing the SDS concentration and column temperature for MEKC. Buffer pH and ethanol (organic modifier) were found to markedly influence the separation selectivity for both MEEKC and MEKC systems. In addition, a higher electric voltage improved the separation efficiency without a noticeable reduction in separation resolution for MEEKC, whereas it caused a poor separation resolution for the MEKC system.  相似文献   

5.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

6.
The potential utility in pharmaceutical analysis of a capillary electrokinetic separation technique that employs a micellar "pseudo-stationary phase" is discussed and illustrated. Chromatograms of separations of vitamin metabolites and derivatized amino acids are presented to illustrate the high efficiency of the technique and the ability to simultaneously separate the charged and neutral components of pharmaceutical samples. The analytical characteristics of the technique and the importance of optimizing experimental parameters, such as surfactant concentration and capillary column diameter, are discussed and demonstrated with the aid of chromatograms.  相似文献   

7.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

8.
Summary A simple and practical micellar electrokinetic capillary chromatography (MEKC) method is proposed for the quantitation of immunosuppressive drugs such as azathioprine (AZA), mycophenolate mofetil (MMF), cyclosporine A (CyA) and tacrolimus (FK 506). The electrophoretic separation of the analytes was performed with a background electrolyte containing 20 mM phosphate buffer at pH 7.5, 50 mM SDS and methanol as an organic modifier. Fused silica capillaries 75 μm i.d. and 60 cm in length were employed and detection of analytes was performed at 214 nm. Thorough validation according to international guidelines showed that the proposed method is reliable and appropiate for the routine analysis of immunosuppressants. Moreover, it may be an advantageous alternative to the traditional chromatographic methodologies currently employed in the pharmaceutical and bioanalysis fields.  相似文献   

9.
H Nishi  S Terabe 《Electrophoresis》1990,11(9):691-701
Electrokinetic chromatography is a new type of analytical separation method which belongs to the group of high performance capillary electrophoretic techniques but whose separation principle is based on that of chromatography. The solute distributes itself between a carrier and the surrounding medium. The carrier, which corresponds to the stationary phase in conventional chromatography, can be transported by electrophoresis with a different velocity from the surrounding medium. The separation is achieved by the differential solute distribution and the differential migration of the carrier. The charged molecules or charged molecular aggregates are employed as the carrier. Various kinds of carriers are available for electrokinetic chromatography along with different partition mechanisms. Among them, micellar electrokinetic chromatography, which employs an ionic micelle as a carrier, has become the most popular method because of its unique and attractive characteristics as well as the separating capability of electrically neutral or nonionic solutes in comparison with capillary zone electrophoresis. The present paper describes the principle, separation characteristics and its application to the analysis of pharmaceuticals.  相似文献   

10.
Three strategies were investigated for the simultaneous separation and on-line preconcentration of charged and neutral hypolipidaemic drugs in micellar electrokinetic chromatography (MEKC). A background electrolyte (BGE) consisting of 20 mM ammonium bicarbonate buffer (pH 8.50) and 50 mM sodium dodecyl sulfate (SDS) was used for the separation and on-line preconcentration of the drugs. The efficiencies of sweeping, analyte focusing by micelle collapse (AFMC), and simultaneous field-amplified sample stacking (FASS) and sweeping, were compared for the preconcentration of eight hypolipidaemic drugs in different conductivity sample matrices. When compared with a hydrodynamic injection (5 s at 50 mbar, 0.51% of capillary volume to detection window) of drug mixture prepared in the separation BGE, improvements of detection sensitivity of 60-, 83-, and 80-fold were obtained with sweeping, AFMC and simultaneous FASS and sweeping, respectively, giving limits of detection (LODs) of 50, 36, and 38 μg/L, respectively. The studied techniques showed suitability for focusing different types of analytes having different values of retention factor (k). This is the first report for the separation of different types of hypolipidaemic drugs by capillary electrophoresis (CE). The three methods were validated then applied for the analysis of target analytes in wastewater samples from Hobart city.  相似文献   

11.
Shihabi ZK  Hinsdale ME 《Electrophoresis》2006,27(12):2458-2463
A simple and rapid ( approximately 4 min) method for the measurement of iohexol in serum for assessing the glomerular filtration rate is described. It is based on direct serum injection on the capillary by MEKC. The method is linear between 8 and 260 mg/L, with an RSD of peak height of 2.9%. Several simple steps have contributed to an improved daily precision, such as choosing a high pH buffer, increasing the SDS concentration, frequent standardization, and eliminating any sample pretreatment.  相似文献   

12.
A general micellar electrokinetic chromatographic (MEKC) strategy for the impurity profiling of drugs was developed involving a sodium dodecyl sulfate (SDS) and a cetyltrimethylammonium bromide (CTAB) MEKC system. With this combination, in principle, each sample component passes the detector in at least one of the two MEKC systems provided that separation buffers of the same pH are used in both systems. In order to select the proper MEKC systems, the electroosmotic flow (EOF) and micelle migration time (t(mc)) were determined for separation buffers of several pH values, containing various amounts of surfactant and organic modifier. The selectivity of the MEKC systems was studied using a mixture of compounds with a wide range of physico-chemical properties. The final selection of two adequate MEKC systems for this approach was based on the requirements that the t(mc) (i.e., analysis time) of both systems was below 20 min and that the t(mc)/t(eof) ratio was above 3 or 2 for the SDS and CTAB system, respectively. Furthermore, the systems should provide high efficiency, exhibit differences in selectivity and use moderate concentrations of modifier and surfactant, so that, if needed, further optimization is possible. The selected MEKC systems contained 60 mM SDS or 10 mM CTAB, respectively, in a phosphate buffer (pH 7.5) with 10% acetonitrile. Some test compounds with extreme mobilities were used to demonstrate the suitability of the MEKC approach to detect each component of a sample. The potential of the proposed MEKC combination for impurity profiling was demonstrated by the analysis of fluvoxamine with several impurities at the 0.1% level.  相似文献   

13.
A review surveying enantiomer separations by micellar electrokinetic chromatography (MEKC) using chiral surfactants is described. MEKC is one of the most popular techniques in capillary electrophoresis, where neutral compounds can be analyzed as well as charged ones, and the use of chiral micelles enable one to achieve the enantioseparation. The chiral MEKC systems are briefly reviewed according to the types of chiral surfactants along with typical applications. As chiral micelles or pseudostationary phases in MEKC, various natural and synthetic chiral surfactants are used, including several low-molecular-mass surfactants and polymerized surfactants or high-molecular-mass surfactants. Cyclodextrin modified MEKC using chiral micelles is also considered.  相似文献   

14.
The retention (migration) behaviour of various barbiturates, phenylurea and triazine herbicides in micellar electrokinetic chromatography (MEKC) with uncoated fused-silica capillaries was compared with the behaviour in micellar electrokinetic chromatography with reduced electroosmotic flow (RF-MEKC) using capillaries modified with linear polyacrylamide. The error in the values of the retention factors caused by the neglection of the contribution of the electroosmotic flow in RF-MEKC was investigated and a method for correcting this error was suggested. The retention was characterised using the lipophilic and polar indices to characterise and to predict the retention as a function of the concentration of the surfactant (sodium dodecylsulphate) in the running buffer in MEKC and in RF-MEKC. Homologous series of n-alkylbenzenes and of n-alkan-2-ones were compared as the standard sets for the calibration of the retention (migration) index scale. The values of the lipophilic indices of a given solute measured in reversed-phase HPLC, MEKC and RF-MEKC are close to each other. Under ideal MEKC conditions, the values of the polarity indices are close to one for various sample solutes. However, for partially ionised compounds such as weakly acidic barbiturates, where the contribution of the electrophoretic migration is significant, the values of the polarity indices are significantly lower than one. Optimum conditions for separations of mixtures of triazine and phenylurea herbicides and of barbiturates using various techniques tested were compared.  相似文献   

15.
In this work, the determination of 11 pesticides (pirimicarb, metalaxyl, pyrimethanil, procymidone, nuarimol, azoxystrobin, tebufenozide, fenarimol, benalaxyl, penconazole, and tetradifon) in rose wines by micellar EKC (MEKC) using reversed electrode polarity stacking mode (REPSM) as online preconcentration strategy is described. The MEKC buffer consisted of 100 mM sodium tetraborate and 30 mM SDS at pH 8.5 with 6% v/v 1-propanol. A solid-phase microextraction (SPME) procedure using PDMS/divinylbenzene (PDMS/DVB) fibers was applied to extract the selected pesticides from the rose wine samples. The comparison between the calibration curves obtained from hydroalcoholic solutions (12% v/v ethanol) and from rose wines (matrix matched calibration) showed the existence of a strong matrix effect. Furthermore, a comparison with calibration curves obtained with white wine samples also showed significant differences for most of the analyzed pesticides. As a result, a matrix matched calibration was developed. Quantitative extraction from spiked wine samples was carried out in triplicate at two levels of concentration (range 0.18-6.00 mg/L). LODs between 0.040 and 0.929 mg/L were achieved, which are below the maximum residue limits (MRLs) established for wine grapes (except for pirimicarb) by the EU and Spain legislation as well as by the Codex Alimentarius. The established method - which is solvent free, cost effective, and fast - was also applied to the analysis of several homemade rose wine samples and a commercial one. Two of the selected pesticides were found in some of the analyzed samples.  相似文献   

16.
A method for the determination of isoniazid (ISO), pyrazinamide (PYR) and rifampicin (RIF) in pharmaceutical products, by micellar electrokinetic capillary chromatography (MEKC) with ultraviolet detection is described. The influence of pH, concentration of surfactants, buffer and organic solvents, over the separation were studied as experimental variables. The optimal separation was carried out at 30 degrees C and 20 kV, using a 40 mM borate buffer and 100 mM sodium dodecylsulphate (SDS) adjusted to pH 8.5. Under these conditions, the analysis is accomplished in about 8 min. The method was applied to the determination of these compounds in different pharmaceuticals with good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

17.
A method for the simultaneous separation and determination of selected triazines, carbamates and phosphororganic compounds by micellar electrokinetic capillary electrophoresis has been developed. A mixture of nine pesticides has been investigated with respect to optimize their separation as a function of buffer and surfactant character and concentration, organic modifier and buffer pH. Quantitative aspects have been also examined. A determination of the compounds was possible up to the range of 0.1 mg/l. Best results have been achieved using a borate/SDS buffer, pH 8. At an applied voltage of 20 kV, the investigated compounds have been successfully resolved within 13 min.Dedicated to Professor Dr. K. Doerffel on the occasion of his 70th birthday  相似文献   

18.
Micellar electrokinetic chromatography (MEKC), which can separate neutral analytes as well as charged analytes by the capillary electrophoretic technique, was developed in 1982 and the first paper was published in 1984. The authors’ group concentrated their effort into the characterization of MEKC as a separation technique until early 1990s. Most issues in MEKC separations were successfully solved and wide applicability of MEKC was verified in 1990s. In particular, sweeping, an on-line sample preconcentration technique, was very successful for the concentration of neutral analyte as well as ionic ones. In this paper, our studies on MEKC will be summarized from the personal viewpoint of the author.  相似文献   

19.
Retention index (I), rather than retention factor (k), was found to be a more reasonable parameter for comparison of the relative affinity of disubstituted benzenes in MEEKC and MEKC, due to independent of I with the SDS surfactant concentration. MEKC and MEEKC may give similar or different I values, depending on types of moieties. With known I and Kow for alkylbenzenes as references in MEKC and MEEKC, the values of Kow for disubstituted benzenes can be estimated from the observed I values, where Kow is the octanol–water distribution constant. In addition, a group additive approach can be used to predict I for disubstituted benzenes with different moieties from the average observed I for the disubstituted benzenes with same moieties. However, electronic effects and/or intramolecular interaction may result in the different observed I from prediction.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号