1.
Clinton A. Krueger Christopher K. Hilton Mark Osgood Jianglin Wu Ching Wu 《International Journal for Ion Mobility Spectrometry》2009,12(1):33-37
Current commercially available ion mobility spectrometers are intended for the analysis of chemicals in the gas phase. Sample
introduction methods, such as direct air sampling, a GC injector or a thermal desorber, are commonly an integral part of these
instruments. This paper describes an electrospray ionization ion mobility spectrometer system that allows direct introduction
samples in solution phase. This allows direct analysis of non-volatile organic and biological samples, and avoids decomposition
of thermally liable samples, providing reliable chemical identification. In addition, the new ion mobility spectrometer allows
mobility analysis with high resolving power. Commonly used commercial IMS systems provide resolving powers between 10 and
30; this new ion mobility spectrometer has resolving power greater than 60 for routine analysis. A high resolution instrument
is necessary for many applications where a complex mixture needs to be separated and quantified. This paper demonstrates the
advantages of using a high resolution ion mobility spectrometer and an electrospray ionization source for the analysis of
non-volatile pharmaceuticals as well as dissolved explosive in solution phase. 相似文献
2.
M. Zühlke K. Zenichowski D. Riebe T. Beitz H.-G. Löhmannsröben 《International Journal for Ion Mobility Spectrometry》2017,20(1-2):47-56
The pressure dependence of sheath gas assisted electrospray ionization (ESI) was investigated based on two complementary experimental setups, namely an ESI-ion mobility (IM) spectrometer and an ESI capillary - Faraday plate setup housed in an optically accessible vacuum chamber. The ESI-IM spectrometer is capable of working in the pressure range between 300 and 1000 mbar. Another aim was the assessment of the analytical capabilities of a subambient pressure ESI-IM spectrometer. The pressure dependence of ESI was characterized by imaging the electrospray and recording current-voltage (I-U) curves. Qualitatively different behavior was observed in both setups. While the current rises continuously with the voltage in the capillary-plate setup, a sharp increase of the current was measured in the IM spectrometer above a pressure-dependent threshold voltage. The different character can be attributed to the detection of different species in both experiments. In the capillary-plate experiment, a multitude of charged species are detected while only desolvated ions attribute to the IM spectrometer signal. This finding demonstrates the utility of IM spectrometry for the characterization of ESI, since in contrast to the capillary-plate setup, the release of ions from the electrospray droplets can be observed. The I-U curves change significantly with pressure. An important result is the reduction of the maximum current with decreasing pressure. The connected loss of ionization efficiency can be compensated by a more efficient transfer of ions in the IM spectrometer at increased E/N. Thus, similar limits of detection could be obtained at 500 mbar and 1 bar. 相似文献
3.
4.
Direct determination of ammoniacal nitrogen in water samples using corona discharge ion mobility spectrometry 总被引:1,自引:0,他引:1
In this study, direct determination of ammoniacal nitrogen residues in water samples using corona discharge ion mobility spectrometry (CD-IMS) was investigated. Pyridine was used as an alternate reagent gas to enhance selectivity and sensitivity of the method. The results indicate that the limit of detection (LOD) was about 9.2x10(-3)mugmL(-1) and the linear dynamic range was obtained from 0.03 to 2.00mugmL(-1). The relative standard deviation was about 11%. Furthermore, this method was successfully applied to the direct determination of ammoniacal nitrogen in river and tap water samples and the results were compared with the Nessler method. The comparison of the results validates the potential of the proposed method as an alternative technique for the analysis of the ammoniacal nitrogen in water samples. 相似文献
5.
A rapid analytical procedure for the on-line determination of methyl tert-butyl ether (MTBE) in water samples was developed. A new membrane extraction unit was used to extract the MTBE from water samples. The concentration of MTBE was determined using ion mobility spectrometry with 63Ni ionization and corona discharge ionization without chromatographic separation. Both ionization methods permit the sensitive determination of MTBE. A detection limit of 100 microg/L was established for the on-line procedure. Neither the inorganic compounds, humic substances nor gasoline were found to exert a significant influence on the peak intensity of the MTBE. The screening procedure can be used for concentrations of monoaromatic compounds (benzene, toluene, xylene) up to 600 microg/L. No sample preparation is required and the analysis results are available within 5 min. In order to determine concentrations between 10 microg/L and 100 microg/L, a discontinuous procedure was developed on the basis of the same experimental set-up. 相似文献
6.
M.T. Jafari 《Talanta》2009,77(5):1632-1639
An improved design for high resolution electrospray ionization ion mobility spectrometry (ESI-IMS) was developed by making some salient modifications to the IMS cell and its performance was investigated. To enhance desolvation of electrospray droplets at high sample flow rates in this new design, volume of the desolvation region was decreased by reducing its diameter and the entrance position of the desolvation gas was shifted to the end of the desolvation region (near the ion gate). In addition, the ESI source (both needle and counter electrode) was positioned outside of the heating oven of the IMS. This modification made it possible to use the instrument at higher temperatures, and preventing needle clogging in the electrospray process. The ion mobility spectra of different chemical compounds were obtained. The resolving power and resolution of the instrument were increased by about 15-30% relative to previous design. In this work, the baseline separation of the two adjacent ion peaks of morphine and those of codeine was achieved for the first time with resolutions of 1.5 and 1.3, respectively. These four ion peaks were well separated from each other using carbon dioxide (CO2) rather than nitrogen as the drift gas. Finally, the analytical parameters obtained for ethion, metalaxyl, and tributylamine indicated the high performance of the instrument for quantitative analysis. 相似文献
7.
Separation of benzodiazepines by electrospray ionization ion mobility spectrometry-mass spectrometry
Laura M. MatzHerbert H. Hill Jr. 《Analytica chimica acta》2002,457(2):235-245
Benzodiazepines are a commonly abused class of drugs; requiring analytical techniques that can separate and detect the drugs in a rapid time period. In this paper, the two-dimensional separation of five benzodiazepines was shown by electrospray ionization (ESI) ion mobility spectrometry (IMS)-mass spectrometry (MS). In this study, both the two dimensions of separation (m/z and mobility) and the high resolution of our IMS instrument enabled confident identification of each of the five benzodiazepines studied. This was a significant improvement over previous IMS studies that could not separate many of the analytes due to low instrumental resolution. The benzodiazepines that contain a hydroxyl group in their molecular structure (lorazepam and oxazepam) were found to form both the protonated molecular ion and dehydration product as predominant ions. Experiments to isolate the parametric reasons for the dehydration ion formation showed that it was not the result of corona discharge processes or the potential applied to the needle. However, the potential difference between the needle and first drift ring did influence both the relative intensity ratios of the two ions and the ion sensitivity. 相似文献
8.
Detection of microcystins using electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry/mass spectrometry 总被引:2,自引:0,他引:2
Ells B Froese K Hrudey SE Purves RW Guevremont R Barnett DA 《Rapid communications in mass spectrometry : RCM》2000,14(16):1538-1542
A combination of electrospray ionization, high-field asymmetric waveform ion mobility spectrometry, and mass spectrometry (ESI-FAIMS/MS) was used to analyze standard solutions of microcystins-LR, -RR, and -YR. The ability of FAIMS to separate ions in the gas phase reduced the amount of background in the mass spectrum without compromising the absolute signal for these microcystins. This reduction in background resulted in a ten-fold improvement in the signal-to-background ratio over conventional ESI-MS. Detection limits, using direct infusion, were determined to be 4, 2, and 1 nM for microcystins-LR, -RR, and -YR, respectively. 相似文献
9.
A high-performance liquid chromatography/electrospray ionization ion trap mass spectrometry (HPLC/ESI-MSn) method has been developed for the trace determination of phytoestrogens in aquatic environmental samples. The method includes solid-phase extraction (SPE) and analysis using liquid chromatography/electrospray ionization ion trap mass spectrometry. The aquatic environmental samples, influent of a wastewater treatment plant (WWTP) and creek water, were adjusted to pH approximately 5 before extraction. The analyzed phytoestrogens were identified by an MSn method and quantified against a deuterated internal standard (genistein-3',5',6,8-D4). In negative ion mode, 0.1% formic acid was employed in acetonitrile/water mobile phase. The method detection limits ranged from 0.5 to 10 ng/L in WWTP influent and from 0.1 to 5 ng/L in creek water. Average SPE recoveries for the analyzed phytoestrogens ranged from 85 to 95%, with a relative standard deviation (RSD) (%) ranging from 3.9 to 6.5. The concentrations of the six analyzed phytoestrogens varied from 0.2 to 600 ng/L with high levels of enterolignans (enterolactone and enterodiol) found in the collected wastewater. The method is shown to be suitable for the determination of phytoestrogens in aquatic environmental samples at nano- and sub-nanogram per liter levels. 相似文献
10.
Jianheng Guo Guozhu Li Hanghang Zhang Xu Jia Qingyan Meng Wenjie Liu 《Electrophoresis》2019,40(12-13):1639-1647
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds. 相似文献
11.
M(NO(3))(x)(-) ions are generated by electrospray ionization (ESI) of metal solutions in nitric acid in negative ion mode. Collision-induced reactions of these ions are monitored in a tandem mass spectrometer (MS) of quadrupole-octopole-quadrupole (QoQ) geometry. For Group 1 and 2 elements, the M(NO(3))(x)(-) ions dissociate into NO(3)(-) and neutral metal nitrate molecules. These elements also form some M(x)(NO(3))x+1- clusters, especially Li(+). Metal nitrate ions from transition elements and Group 13 elements fragment into oxo products and also undergo internal electron transfer to leave the M atom in a lower oxidation state. To calibrate the collision energy, the dissociation energy of O-NO(2)(-) is found to be 5.55 eV, about 0.76 eV lower than a value derived from thermochemistry. The product ions from Fe(NO(3))(4)(-) ions have low formation thresholds of only 0.5 to 2 eV. 相似文献
12.
Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS) 总被引:5,自引:0,他引:5
The analysis of explosives with ion mobility spectrometry (IMS) directly from aqueous solutions was shown for the first time using an electrospray ionization technique. The IMS was operated in the negative mode at 250°C and coupled with a quadrupole mass spectrometer to identify the observed IMS peaks. The IMS response characteristics of trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DNT), 2-amino-4,6-dinitrotoluene (2-ADNT), 4-nitrotoluene (4-NT), trinitrobenzene (TNB), cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), cyclo-tetramethylene-tetranitramine (HMX), dinitro-ethyleneglycol (EGDN) and nitroglycerine (NG) were investigated. Several breakdown products, predominantly NO2− and NO3−, were observed in the low-mass region. Nevertheless, all compounds with the exception of NG produced at least one ion related to the intact molecule and could therefore be selectively detected. For RDX and HMX the [M+Cl−]− cluster ion was the main peak and the signal intensities could be greatly enhanced by the addition of small amounts of sodium chloride to the sprayed solutions. The reduced mobility constants (K0) were in good agreement with literature data obtained from experiments where the explosives were introduced into the IMS from the vapor phase. The detection limits were in the range of 15–190 μg l−1 and all calibration curves showed good linearity. A mixture of TNT, RDX and HMX was used to demonstrate the high separation potential of the IMS system. Baseline separation of the three compounds was attained within a total analysis time of 6.4 s. 相似文献
13.
A sensitive analytical method for the simultaneous assay of nitrate and nitrite in water and some fruit samples is presented. The method is based on nitrite determination using the diazotization-coupling reaction by column preconcentration and on the reduction of nitrate to nitrite using the Cd-Cu reductor column. Nitrite is diazotized with sulfanilamide (SAM) in the pH range 2.0-5.0, sulfamethizole (SM) in pH 1.8-5.6 and sulfadimidine (SD) in pH 1.8-4.0 in a hydrochloric acid medium to form water-soluble colourless diazonium cations. These cations were coupled with sodium 1-naphthol-4-sulfonate (NS) in the pH range 9.0-12.0 for the SAM-NS system, pH 8.6-12.0 for the SM-NS system and pH 9.4-12.0 for the SD-NS system to be retained on naphthalene-tetradecyldimethylbenzylammonium (TDBA)-iodide (I) adsorbent packed in a column. The solid mass is dissolved out from the column with 5 ml of dimethylformamide (DMF) and the absorbance is measured by a spectrophotometer at 543 nm for SAM-NS, 537 nm for SM-NS and 530 nm for SD-NS. The calibration graph was linear over 30-600 ng NO(2)-N and 22-450 ng NO(3)-N in 15 ml of final aqueous solution (i.e. 2-40 ng NO(2)-N ml(-1) and 1.5-30 ng NO(3)-N ml(-1) in aqueous sample) for three systems. The detection limits were 1.4 ng NO(2)-N ml(-1) and 1.1 ng NO(3)-N ml(-1) for SAM-NS, 1.2 ng NO(2)-N ml(-1) and 0.89 ng NO(3)-N ml(-1) for SM-NS, 1.0 ng NO(2)-N ml(-1) and 0.75 ng NO(3)-N ml(-1) for SD-NS, respectively. The concentration factor is eight for SAM-NS and SM-NS, and 12 for SD-NS. Interferences from various foreign ions have been examined and the method was successfully applied to the determination of low levels of nitrate and nitrite in water and some fruit samples. 相似文献
14.
Ablajan K Abliz Z Shang XY He JM Zhang RP Shi JG 《Journal of mass spectrometry : JMS》2006,41(3):352-360
Flavonol 3,7-di-O-glycosides were investigated by negative ion electrospray ionization tandem mass spectrometry using a quadrupole linear ion trap (LIT) mass spectrometer. The results indicate that the fragmentation behavior of flavonol 3,7-di-O-glycosides is substantially different from that of their isomeric mono-O-diglycosides. In order to characterize a flavonoid as a flavonol 3,7-di-O-glycoside, both [Y3(0) - H]-* and [Y(0) - 2H]- ions should be present in [M - H]- product ion spectrum. The MS(3) product ion spectra of Y3(0)-, [Y3(0) - H]-* and Y7(0)- ions generated from the [M - H]- ion provide sufficient structural information for the determination of glycosylation position. Furthermore, the glycosylation positions are determined by comparing the relative abundances of Y3(0)- and Y7(0)- ions and their specific fragmentation patterns with those of flavonol mono-O-glycosides. In addition, a [Y3(0) - H]-* ion formed by the homolytic cleavage of 3-O glycosidic bond with high abundance points to 3-O glycosylation, while a [Y(0) - 2H]- ion formed by the elimination of the two sugar residues is consistent with glycosylation at both the 3-O and 7-O positions. Investigation of negative ion ESI-MS(2) and MS(3) spectra of flavonol O-glycosides allows their rapid characterization as flavonol 3,7-di-O-glycoside and their differentiation from isomeric mono-O-diglycosides, and also enables their direct analysis in crude plant extracts. 相似文献
15.
16.
17.
Axel Mie Madalina Sandulescu Lennart Mathiasson Jenny Emnéus Curt T Reimann 《Analytical sciences》2008,24(8):973-978
Triazines comprise an important pollutant class owing to continued use in certain countries, and owing to strong environmental persistence that leads to problems even in countries like Sweden where the use of triazines has been prohibited for some years. We investigated mass-selective detection for analysis of triazines. More specifically, we studied the background reduction and sensitivity enhancement that result from the use of a new interface technique, field-asymmetric ion mobility spectrometry (FAIMS), in conjunction with electrospray ionization ion-trap mass spectrometry. This technique allows for ion sorting and discrimination against the considerable "chemical noise", nonspecific cluster and fragment ions, which are typically generated in electrospray ionization. This paper presents results of a pilot study of triazines and some metabolites in ideal solvents. Our long-range goal is automated analysis with mass-selective detection coupled to membrane-based sample cleanup and enrichment for additional enhancement in sensitivity. 相似文献
18.
Sizing large proteins and protein complexes by electrospray ionization mass spectrometry and ion mobility 总被引:1,自引:0,他引:1
Kaddis CS Lomeli SH Yin S Berhane B Apostol MI Kickhoefer VA Rome LH Loo JA 《Journal of the American Society for Mass Spectrometry》2007,18(7):1206-1216
Mass spectrometry (MS) and ion mobility with electrospray ionization (ESI) have the capability to measure and detect large noncovalent protein-ligand and protein-protein complexes. Using an ion mobility method of gas-phase electrophoretic mobility molecular analysis (GEMMA), protein particles representing a range of sizes can be separated by their electrophoretic mobility in air. Highly charged particles produced from a protein complex solution using electrospray can be manipulated to produce singly charged ions, which can be separated and quantified by their electrophoretic mobility. Results from ESI-GEMMA analysis from our laboratory and others were compared with other experimental and theoretically determined parameters, such as molecular mass and cryoelectron microscopy and X-ray crystal structure dimensions. There is a strong correlation between the electrophoretic mobility diameter determined from GEMMA analysis and the molecular mass for protein complexes up to 12 MDa, including the 93 kDa enolase dimer, the 480 kDa ferritin 24-mer complex, the 4.6 MDa cowpea chlorotic mottle virus (CCMV), and the 9 MDa MVP-vault assembly. ESI-GEMMA is used to differentiate a number of similarly sized vault complexes that are composed of different N-terminal protein tags on the MVP subunit. The average effective density of the proteins and protein complexes studied was 0.6 g/cm(3). Moreover, there is evidence that proteins and protein complexes collapse or become more compact in the gas phase in the absence of water. 相似文献
19.
Characterizing ion mobility and collision cross section of fatty acids using electrospray ion mobility mass spectrometry 下载免费PDF全文
Fang Zhang Su Guo Manyu Zhang Zhixu Zhang Yinlong Guo 《Journal of mass spectrometry : JMS》2015,50(7):906-913
This study investigated the ion mobility (IM) and the collision cross section (CCS) of fatty acids (FAs) using electrospray IM MS. The IM analysis of 18 FA ions showed intriguing differences among the saturated FAs, monounsaturated FAs, multi‐unsaturated FAs, and cis‐isomer/trans‐isomer with respect to the aliphatic tail chains. The length of aliphatic tail chain present in the ion structures had a strong influence on the differentiation of drift, while the number of double bond showed a weaker influence. The tiny drift differences between cis‐isomer and trans‐isomer were also observed. In the CCS measurements, two internal standards were involved in the mobility calibration and accuracy estimation. It insured our empirical CCS values were of high experimental precision (±0.35% or better) and accuracy (±0.25% or better). Moreover, the mass‐to‐charge ratio (m/z) – mobility plots obtained by ion mobility spectrometry with mass spectrometry analysis of FAs – was used to investigate the structural relationship between the molecules. Each series of FAs sharing a similar structure was aligned in the linear plot. Finally, the developed procedure was applied to the determination of FAs in rat adipose tissues, and it allowed the presence of 13 FAs to be confirmed with their exact masses and CCS values. These studies reveal the direct relationship between the behaviors in IM and the molecular structures and thus may provide further validations to the FA identification process. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
20.
A new method was developed for the analysis of nitrate and nitrite in a variety of water matrices by using reversed-phase liquid chromatography/electrospray ionization/mass spectrometry in the negative ion mode. For this direct analysis method, nitrate and nitrite anions were well separated under the optimized LC conditions, detected by monitoring m/z 62 and m/z 46 ions, and quantitated by using an isotope dilution technique that utilized the isotopically labeled analogs. The method sensitivity, accuracy, and precision were investigated, along with matrix effects resulting from common inorganic matrix anions. The isotope dilution technique, along with sample pretreatment using barium, silver, and hydrogen cartridges, effectively compensated for the ionization suppression caused by the major water matrix anions, including chloride, sulfate, phosphate, and carbonate. The method detection limits, based on seven reagent water replicates fortified at 0.01 mg N/L nitrate and 0.1 mg N/L nitrite, were 0.001 mg N/L for nitrate and 0.012-0.014 mg N/L for nitrite. The mean recoveries from the replicate fortified reagent water and lab water samples containing the major water matrix anions, were 92-103% for nitrate with an imprecision (relative standard deviation, RSD) of 0.4-2.1% and 92-110% for nitrite with an RSD of 1.1-4.4%. For the analysis of nitrate and nitrite in drinking water, surface water, and groundwater samples, the obtained results were generally consistent with those obtained from the reference methods. The mean recoveries from the replicate matrix spikes were 92-123% for nitrate with an RSD of 0.6-7.7% and 105-113% for nitrite with an RSD of 0.3-1.8%. 相似文献