首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A microscopic and voltammetric characterization of lactate oxidase- (LOx-) based bioanalytical platforms for biosensor applications is presented. In this context, emphasis is placed on amperometric biosensors based on LOx that have been immobilized by direct absorption on carbon surfaces, in particular, glassy carbon (GC) and highly ordered pyrolytic graphite (HOPG). The immobilized LOx layers have been characterized using atomic force microscopy (AFM) under liquid conditions and cyclic voltammetry. In addition, spatially resolved mapping of enzymatic activity has been carried out using scanning electrochemical microscopy (SECM). In the presence of lactate with hydroxymethylferrocene (HMF) as a redox mediator in solution, biosensors obtained by direct adsorption of LOx onto GC electrodes exhibited a clear electrocatalytic activity, and lactate could be determined amperometrically at 300 mV versus SSCE. The proposed biosensor also exhibits good operating performance in terms of linearity, detection limit, and lifetime.  相似文献   

2.
We report on the use of polymyxin (PM), a cyclic cationic lipodecapeptide, as an electrode modifier for studying protein film voltammetry (PFV) on Au and single-walled carbon nanotube (SWNT) electrodes. Pretreating the electrodes with PM allows for the subsequent immobilization of an active submonolayer of [NiFe]-hydrogenase from Allochromatium vinosum ( Av H2ase). Probed by cyclic voltammetry (CV), the adsorbed enzyme exhibits characteristic electrocatalytic behavior that is stable for several hours under continuous potential cycling. An unexpected feature of the immobilization procedure is that the presence of chloride ions is a prerequisite for obtaining electrocatalytic activity. Atomic force microscopy (AFM) relates the observed catalytic activity to enzymatic adsorption at the PM/Au(111) surface, and a combination of concentration-dependent CV and AFM is used to investigate the interaction between the enzyme and the PM layer.  相似文献   

3.
The electrochemical behavior of a redox-active, ferrocene-modified ionic liquid (1-ferrocenylmethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) in acetonitrile and in an ionic liquid electrolyte (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) is reported. Reversible electrochemical behavior was observed in each electrolyte with responses typical of those for unmodified ferrocene observed in each medium. In the ionic liquid electrolyte, the diffusion coefficient of the redox-active ionic liquid increased by a factor of 5 upon increasing the temperature from 27 to 90 degrees C. The kinetics of electron transfer across the ionic liquid/electrode interface were studied using cyclic voltammetry, and the standard heterogeneous electron transfer rate constant, k (0) was determined to be 4.25 x 10 (-3) cm s (-1). Scanning electrochemical microscopy was then also used to probe the heterogeneous kinetics at the interface between the ionic liquid and the solid electrode and conventional kinetic SECM theory was used to determine k (0). The k (0) value obtained using SECM was higher than that determined using cyclic voltammetry. These results indicate that SECM is a very useful technique for studying electron transfer dynamics in ionic liquids.  相似文献   

4.
Pt–Ag nanoparticle co‐deposits with different Pt–Ag ratios were prepared on a glassy carbon (GC) surface by pulsed electrodeposition and investigated for their catalytic activity in electrocatalytic oxygen reduction by using cyclic voltammetry (CV), rotating disc electrode (RDE) and scanning electrochemical microscopy (SECM) in 0.1 M phosphate buffer (pH 7.0). The atomic composition of the Pt–Ag co‐deposits was studied by means of energy‐dispersive X‐ray analysis (EDAX). In combination with X‐ray diffraction (XRD), the presence of partly alloyed Pt and Ag on the GC surface was confirmed. Scanning electron microscopy (SEM) images indicate that the prepared Pt–Ag catalyst particles are homogenously dispersed over the GC surface. Their size and morphology depend on their composition. The electrocatalytic activity of Pt–Ag deposits with high Pt content was the highest, exceeding even that of electrodeposited Pt as evaluated by quantitative RDE analysis. The redox competition mode of scanning electrochemical microscopy (RC‐SECM) was successfully used to visualize the local catalytic activity of the deposited Pt–Ag particles. Semi‐quantitative assessment of the SECM results confirmed the same order of activity of the different catalysts as the RDE investigations.  相似文献   

5.
We studied the properties of mixed alkanethiol-dendrimer layers on a gold support and their application in biosensing. We showed that properties of glucose sensor can be modified using a different ratio of 1-hexadecanethiol (HDT) and poly(amidoamine) dendrimer of first generation (G1). The cyclic voltammetry in the presence of the redox couple, Fe(CN)(6)(3-)/Fe(CN)(6)(4-), was used for estimating how effectively the layer blocks the redox probe's access to the electrode surface. A scanning electrochemical microscope (SECM) was used to image the resulting distribution of the organic compounds. We found that with increasing content of dendrimers, the integrity of the layers was improved.  相似文献   

6.
This work presents a scanning electrochemical microscopy (SECM)-based in situ corrosion probing methodology that is capable of monitoring the release of zinc species in corrosion processes. It is based on the use of Hg-coated Pt microelectrodes as SECM tips, which offer a wider negative potential range than bare platinum or other noble-metal tips. This allows for the reduction of zinc ions at the tip to be investigated with low interference from hydrogen evolution and oxygen reduction from aqueous solutions. The processes involved in the corrosion of zinc during its immersion in chloride-containing solutions were successfully monitored by scanning the SECM tip, set at an adequate potential, across the sample either in one direction or in the X-Y plane parallel to its surface. In this way, it was possible to detect the anodic and cathodic sites at which the dissolution of zinc and the reduction of oxygen occurred, respectively. Additionally, cyclic voltammetry (CV) or constant potential measurements were used to monitor the release of zinc species collected at the tip during an SECM scan.  相似文献   

7.
The generation and application of nanodes in SECM experiments are described. Nanodes are ultramicroelectrodes with an active disk diameter in the submicrometer range. We investigated the behaviour of these electrodes by testing their properties with SECM applications which were previously performed at the micrometer scale. The active diameter of the nanodes was determined using cyclic voltammetry and SECM. The nanoanalysis was conducted at two nano interdigitated arrays. The nanostructuring was demonstrated by galvanic and electroless silver deposition from solution and from the surface, respectively. Experiments with nanodes illustrate that they exhibit the same behaviour as ultramicroelectrodes, but are more sensitive to adsorption and dirt particles in the electrolyte solution.  相似文献   

8.
利用电化学湿法印章技术在氧化铟锡(ITO)导电玻璃上制备AuPd合金和Au的双组分阵列图案. 采用具有微浮雕图案的琼脂糖印章存储足够多的溶液,并通过控制电沉积的时间来控制图案厚度. 应用场发射扫描电子显微镜(FE-SEM),X射线能谱分析(EDX)和原子力显微镜(AFM)分别对ITO表面上的AuPd合金和Au的形貌和组分进行表征,并通过循环伏安(CV)技术和扫描电化学显微镜(SECM)研究比较了Au和AuPd合金的催化活性. 利用扫描电化学显微镜(SECM)的针尖产生-基底收集(TG-SC)模式和氧化还原竞争(RC)模式,发现Au电极对二茂铁甲醇氧化物(FcMeOH+)电催化还原能力高于AuPd合金电极,而在AuPd合金上催化还原H2O2的能力显著高于Au.  相似文献   

9.
The electrochemical behaviour of ferrocenemethanol (FcMeOH) has been studied in a range of room-temperature ionic liquids (RTILs) using cyclic voltammetry, chronoamperomery and scanning electrochemical microscopy (SECM). The diffusion coefficient of FcMeOH, measured using chronoamperometry, decreased with increasing RTIL viscosity. Analysis of the mass transport properties of the RTILs revealed that the Stokes-Einstein equation did not apply to our data. The "correlation length" was estimated from diffusion coefficient data and corresponded well to the average size of holes (voids) in the liquid, suggesting that a model in which the diffusing species jumps between holes in the liquid is appropriate in these liquids. Cyclic voltammetry at ultramicroelectrodes demonstrated that the ability to record steady-state voltammograms during ferrocenemethanol oxidation depended on the voltammetric scan rate, the electrode dimensions and the RTIL viscosity. Similarly, the ability to record steady-state SECM feedback approach curves depended on the RTIL viscosity, the SECM tip radius and the tip approach speed. Using 1.3 μm Pt SECM tips, steady-state SECM feedback approach curves were obtained in RTILs, provided that the tip approach speed was low enough to maintain steady-state diffusion at the SECM tip. In the case where tip-induced convection contributed significantly to the SECM tip current, this effect could be accounted for theoretically using mass transport equations that include diffusive and convective terms. Finally, the rate of heterogeneous electron transfer across the electrode/RTIL interface during ferrocenemethanol oxidation was estimated using SECM, and k(0) was at least 0.1 cm s(-1) in one of the least viscous RTILs studied.  相似文献   

10.
《Electroanalysis》2005,17(11):953-958
An electron transfer reaction between ascorbic acid (H2A) in an aqueous solution and oxidizing agent in an organic solution immiscible with water has been studied by thin‐layer cyclic voltammetry (TLCV) for charge transfer at the interface between two immiscible electrolyte solutions (ITIES). As an antioxidant, H2A provide electrons through the aqueous/organic interface to reduce Fc+ and the procedure has been proved to be a one electron process again. In this work, the first combination of TLCV and scanning electrochemical microscopy (SECM) was achieved and showed a reasonable agreement between the results from the two different approaches. Otherwise, lower concentration ratios Kr of aqueous to organic reactants was adopted, which is given as evidence to the proposed procedure of Barker.  相似文献   

11.
In this paper we describe the deposition of enzyme layers on cyclodextrin-modified surfaces through self-assembly with adamantane-appended alkaline phosphatase using cyclodextrin-capped gold nanoparticles as supramolecular linkers. The system was studied by surface plasmon resonance and electrochemical methods (cyclic voltammetry, impedance spectroscopy). Up to three enzyme layers were formed on the cyclodextrin coated electrodes and the modified surface was used for the electrochemical detection of heavy metals (Cd2+, Ag+) based on the inhibition of enzymatic activity by these metal cations.  相似文献   

12.
The scanning electrochemical microscope (SECM) is used to image the activity of enzymes immobilized on the surfaces of disk-shaped carbon-fiber electrodes. SECM was used to map the concentration of enzymatically produced hydroquinone or hydrogen peroxide at the surface of a 33-microm diameter disk-shaped carbon-fiber electrode modified by an immobilized glucose-oxidase layer. Sub-monolayer coverage of the enzyme at the electrode surface could be detected with micrometer resolution. The SECM was also employed as a surface modification tool to produce microscopic regions of enzyme activity by using a variety of methods. One method is a gold-masking process in which microscopic gold patterns act as mask for producing patterns of chemical modification. The gold masks allow operation in both a positive or negative process for patterning enzyme activity. A second method uses the direct mode of the SECM to produce covalently attached amine groups on the carbon surface. The amine groups are anchors for attachment of glucose oxidase by use of a biotin/avidin process. The effect of non-uniform enzyme activity was investigated by using the SECM tip to temporarily damage an immobilized enzyme surface. SECM imaging can observe the spatial extent and time-course of the enzyme recovery process.  相似文献   

13.
Taking the advantage of the stability and penetrability of polyelectrolyte films formed by layer-by-layer (LbL) deposition, noble metal particles of Pd and Pt were fabricated in a preformed polyeletrolyte multilayer film by galvanic deposition. The metal deposition occurred as metal particles and they were tested for their properties as electrocatalyst for oxygen reduction. Atomic force microscopy (AFM) was used to characterize the morphology of the particle films. The noble metal particles were investigated by cyclic voltammetry (CV) and scanning electrochemical microscopy (SECM) with respect to oxygen reduction. The results show that the electrocatalytic properties of the Pd particle film can be adjusted by the electrodeposition time. The hydrogen peroxide formed as an intermediate during electroreduction of dioxygen was conveniently measured in the SECM using the substrate-generation/tip-collection mode. The relevance of the main reduction pathways could be extracted from fitting the current transients to an analytical model.  相似文献   

14.
Scanning electrochemical microscopy (SECM) was used for imaging of n-hexadecanethiol-modified Au surfaces. In these studies, small defects were observed in the monolayer when a submicrometer electrode was used as an SECM tip, although a cyclic voltammogram of a Au disk electrode showed that the surface of the Au was completely covered with n-hexadecanethiol. The dependence of the SECM images on the potential of the Au electrode was also examined. A comparison of the current at the Au electrode and the tip current in the SECM images showed that direct electron transfer through the monolayer was dominant, rather than electron transfer at the defects. The size of the defects was estimated from the tip current to be 1-100 nm, under the assumption that the defects were small compared to the SECM probe.  相似文献   

15.
Herein, the scanning electrochemical microscopy (SECM) approach is applied to study the formation of thiol-porphyrin self-assembled monolayer (SAMs). Using cyclic voltammetry (CV), the formation process is characterized adopting different probe molecules. The observed phenomena indicate that the formation process is affected by solution properties and the molecular structure of the probe molecules. In K(3)Fe(CN)(6) , the SAMs show a strong electron-transfer (ET) blocking effect on a pure porphyrin-modified electrode. However, addition of metal ions to the porphyrin molecules leads to ET. A consistent tendency is observed throughout the modification process using CV and SECM methods. Furthermore, k(eff) values, the apparent heterogeneous rate constants, obtained for different modification periods affirm the validity of these results. SECM images are used to collect surface information in the course of the modification process when the substrate potential is 0.5 V versus Ag/AgCl. The effect of the substrate potential indicates that the oxidation of the porphyrin molecules is supported by more positive potentials because of the similar bimolecular reaction of the porphyrin ring with positive charge and the probe molecules with negative charge.  相似文献   

16.
We report the cyclic voltammetry, chronoamperometry, and scanning electrochemical microscopy of ferrocene dissolved in deep eutectic solvents (DES), consisting of choline chloride (ChCl) and either trifluoroacetamide (TFA) or malonic acid as the hydrogen-bond donor. Despite the use of ultramicroelectrodes, which were required due to the modest conductivities of the DES employed, linear diffusion behavior was observed in cyclic voltammetric experiments. The high viscosity of 1:2 ChCl/TFA relative to non-aqueous electrochemical solvents leads to a low diffusion coefficient, 2.7 x 10(-8) cm2 s(-1) for ferrocene in this medium. Because of the difficulties in achieving steady-state conditions, SECM approach curves were tip velocity dependent. Under certain conditions, SECM approach curves to an insulating substrate displayed a positive-feedback response. Satisfactory simulation of this unexpected behavior was obtained by including convection terms into the mass transport equations typically used for SECM theory. The observance of positive-feedback behavior at an insulating substrate can be described in terms of a dimensionless parameter, the Peclet number, which is the ratio of the convective and diffusive timescales. Fitting insulator approach curves of ferrocene in 1:2 ChCl/TFA shows an apparent increase in the diffusion coefficient with increasing tip velocity, which can be explained by DES behaving as a shear thinning non-Newtonian fluid.  相似文献   

17.
Micropatterns of diaphorase (Dp) were fabricated on glass substrates by the microcontact printing (μCP) method and characterized with atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM). AFM images of the printed samples revealed that the mean height of the Dp patterns was 3–5 nm, indicating the formation of a monolayer pattern. The Dp molecules on the surface organized themselves into two-dimensional arrays. We used two kinds of inking solutions: Dp–phosphate buffer solution (PBS) (pH 7.0) and Dp–PBS (pH 7.0) with glutaraldehyde (GA, 1% v/v) as a cross-linking reagent. Although the AFM imaging showed high-quality Dp monolayer patterns in both cases, SECM measurements indicated that the enzymatic activity of Dp was almost lost when Dp–PBS with GA was used as the inking solution, whereas clear enzymatic activity was found when Dp–PBS was used.  相似文献   

18.
以PS-b-PEO纳米孔膜为基体电极,采用电沉积技术制备了Pt纳米线,用扫描电化学显微镜(SECM)、扫描电镜(SEM)和X-射线能谱(EDS)分析法表征了基体电极和Pt纳米线。利用循环伏安法考察了Pt纳米线的电化学性能。实验结果表明,Pt纳米线对甲酸氧化表现出优异的电催化活性。此外,Pt纳米线具有良好的稳定性和重现性,可望用于实际样品中甲酸的测定。  相似文献   

19.
Scanning electrochemical microscopy (SECM) was used to characterize enzyme-modified glass-gold specimens. The exposed gold surface was functionalized with an aminothiol and reacted with carbodiimide-activated glucose oxidase. The specimen surface was examined with SECM, using a 25 μm platinum electrode. Images were acquired showing the topography, electric conductivity, and enzymatic activity of the composite surface. It was found that the hydroxy-groups of the glass surface are as likely to bind to the activated enzyme as the amino-groups on the gold surface.  相似文献   

20.
The electrocatalytic activity of platinum for hydrogen oxidation in 0.01 M H2SO4 + 0.1 MNa2SO4 solution has been investigated by scanning electrochemical microscopy (SECM) technique. The cyclic voltammogram (CV), approach curve, area scan imaging and chronoamperometric methods have been used. The results indicate that the imaging capability of the SECM feedback mode can be used more efficiently to visually identify materials' electrocatalytic activity, compared with the approach curve method for identification of the conductive or insulating nature of a surface. The SECM imaging method has demonstrated the effects of Pt substrate potential on the electrocatalytic oxidation of hydrogen under a constant tip potential. It is found that the more positive the Pt substrate potential, the lower the electrocatalytic activity of the Pt. Furthermore, the chronoamperometric results support the variation of the electrocatalytic activity with the Pt substrate potential as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号