首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Tea is one of the most popular beverages in the world. The number of reports on the analysis of tea components, especially for catechins, has recently been increasing. We review the recent reports on the analysis of tea components using the analytical methods of high-performance liquid chromatography and high-performance capillary electrophoresis.  相似文献   

2.
Wang SP  Huang SP 《Electrophoresis》2001,22(11):2222-2230
Stilbenes, fluorescence whitening agents (FWAs), are usually added to cleaning agents in household and in industry. Capillary electrophoresis (CE) was often applied to separate various compounds simultaneously for its multinomial advantages. In this paper, we established analytical methods of six diaminostilbenes with CE and ion-pair chromatography (IPC). The optimum mobile phase for IPC was 11.78 mM tetrabutylammonium hydrogen sulfate (TBA) aqueous and acetonitrile. An IPC method has been developed for simple and direct separation for diaminostilbenes, anionic substances, with TBA as ion-pair reagent. Satisfactory linear ranges (7.0 x 10(-3) approximately 3.0 x 10 microg/mL), correlation coefficients (0.9992-0.9999), and detection limits (6-13 ng/mL) were obtained. Separations were also performed by capillary zone electrophoresis (CZE) using a buffer consisting of Tris (pH 10.1), n-tetradecyltrimethylammonium bromide (TTAB) and acetonitrile. A linear range of 5.0 x 10(-1) - 4.0 x 10 microg/mL, correlation coefficients between 0.9975 and 0.9998, and detection limits between 337 and 446 ng/mL were obtained. In particular, the separation of a pair of similar compounds (mass difference of 2) was achieved by addition of TTAB. The optimum analytical methods of CE and high-performance liquid chromatography (HPLC) were applied to commercial household with direct analysis and standard addition. No significant bias were shown between them by t-test at 95% confidence level.  相似文献   

3.
The compounds of flavonoid, an important group in nature, can prevent coronary heart disease and anticancer by virtue of the characteristics of antioxidation. Nine flavonoids most often seen in grape wine, namely apigenin, baicalein, naringenin, luteolin, hesperetin, galangin, kaempferol, quercetin, and myricetine, were determined by means of high-performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE) in this work. A successful resolution was obtained from an unusual additive of tetrahydrofuran in mobile phase by HPLC. One notable thing is that the mixture of luteolin and quercetin could be separated for the first time by HPLC. In addition, the better detection limit was still attainable even with the use of tetrahydrofuran. The detection limits of CZE performed in borate buffer were hundreds-fold better than in previous reports. Furthermore, the retention and migration behavior of the analytes studied were discussed. As the result of this study, the elution order of flavone and flavonone was reversed to the contention proposed by Wulf et al. It was predictable from the interaction with tetrahydrofuran. Consequently, the extracts from grape wine with solid-phase extraction were analyzed by developing methods of HPLC and CZE. The obtained recoveries ranged from 90 to 107% and the relative standard deviations were under 6.3%.  相似文献   

4.
High-performance capillary electrophoresis (HPCE) was evaluated as a potential technique for the regulatory analysis of commercial dosage forms of insulin. A comparison was made to a liquid chromatographic analysis presently being proposed as an official monograph in the United States Pharmacopeia. The salient points of this comparison were accuracy, precision and ease of use. Both authentic (i.e. single blind, spiked) samples and commercial pharmaceutical formulations (injections) were examined. Chromatographic analyses of both commercial formulations and authentic samples were characterized by good precision, with accuracy being supported by results from authentic (spiked) samples. Conventional HPCE (by which is meant a non-micellar electrolyte used with an uncoated, unmodified fused-silica capillary) achieved reasonable accuracy, but less than impressive precision, when applied to authentic samples. When used for commercial formulations, this type of HPCE did not produce a level of accuracy suitable for regulatory purposes, even with the use of an internal standard.  相似文献   

5.
High-performance liquid chromatography and capillary zone electrophoresis have been used for the separation of homologues and structural isomers of linear alkylbenzenesulfonates with subsequent UV detection. The analytical advantages of these techniques are applied to the analysis of technical products containing high amounts of LAS as well as river water samples with very low LAS concentrations using preconcentration steps.Dedicated to Professor Dr. H. Kriegsmann on the occasion of his 70th birthday  相似文献   

6.
Recent developments in the analysis of glycoproteins by high-performance capillary electrophoresis are reviewed, with emphasis on their carbohydrate chains. Glycoforms of glycoproteins were directly separated from each other by careful optimization of the analytical conditions. Glycopeptides in tryptic digests were separated and the peptides carrying glycosylation sites were differentiated from others. Released oligosaccharide chains were separated at a low wavelength. Precolumn derivatization by various methods extended the utility of both the absorption at a low wavelength. Precolumn derivatization by various methods extended the utility of both the separation mode and detection technique. Dual mode analysis after derivatization permitted reliable identification and quantification without references.  相似文献   

7.
The objective of this work was to develop a sample preparation procedure for determination of the carbohydrate profiles in commercial juice samples by three principally different analytical methods: capillary electrophoresis (CE) with indirect detection, high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The preparation and purification of juice samples prior to analysis is described. The method using Carrez reagents was found to be an efficient preparation tool for all three methods. The addition of Carrez reagents to the samples for mass analysis improved the quality of the mass spectra of oligosaccharides. The amounts of glucose, fructose, and sucrose as major carbohydrates in fruit juices measured by CE using a simple instrument are in good agreement with the HPLC values and the data declared by the producers of the juices. The results from both methods are critically evaluated and their impact for studies of authenticity is discussed. The decrease of sucrose amount during the storage of samples was explained by acid hydrolysis of this disaccharide.  相似文献   

8.
This paper describes the simultaneous determination of catechins and theaflavins in green and black teas, using reversed-phase high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The tea polyphenols analyzed included (+)-catechin, catechin gallate, (-)-epicatechin, epicatechin-3-gallate, epigallocatechin, epigallocatechin-3-gallate, theaflavin, theaflavin-3-monogallate, theaflavin-3'-monogallate and theaflavin-3,3'-gallate. These polyphenols together with six other tea ingredients such as caffeine, adenine, theophylline, quercetin, gallic acid and caffeic acid were separated within 27 min by HPLC and in less than 10 min by CE. The optimal analytical conditions of both chromatographic methods were investigated for the convenience and reliability for routine analysis. Both HPLC and CE were found to be reliable and compatible. The reproducibility of the within-day assay using both methods was generally >90%. The day-to-day variation of retention time was <5% for HPLC, while the variation of migration time for CE was <2%. The analysis time of CE was three-times faster, however it is five-times less sensitive than HPLC, which has detection limits of 0.05 microg/ml and 0.5 microg/ml for catechins and theaflavins, respectively.  相似文献   

9.
Triton X-100 is applied to influenza vaccines at different stages of the manufacturing process to prevent aggregation and precipitation of biomolecules. Furthermore it is used to disintegrate the virus particles in split vaccine and to guarantee the homogeneity during production and utilisation. The final concentration of Triton X-100 has to be determined because the concentration changes in manufacturing process. The determination of the total amount of Triton X-100 as well as the separation of its ethylene oxide oligomers was possible with high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). In HPLC a change of the column and eluent was necessary, in CE different electrolytes were used for the various separation effects. The HPLC method for the analysis of total Triton was preferred for the quantification of Triton X-100 in influenza vaccine because of better linearity, reproducibility and detection sensitivity compared to CE. In the end products an average concentration of 0.117 mg/mL was found. Received: 19 December 1996 / Revised: 27 February 1997 / Accepted: 6 March 1997  相似文献   

10.
Yang X  Zhang X  Li A  Zhu S  Huang Y 《Electrophoresis》2003,24(9):1451-1457
A novel comprehensive two-dimensional (2-D) separation system coupling capillary high-performance liquid chromatography (cHPLC) with microchip electrophoresis (chip CE) is demonstrated. Reversed-phase cHPLC was used as the first dimension, and chip CE acted as the second dimension to perform fast sample transfers and separations. A valve-free gating interface was devised simply by inserting the outlet-end of LC column into the cross-channel on a specially designed chip. A home-made confocal laser-induced fluorescence detector was used to perform on-chip high-sensitive detection. The cHPLC effluents were continuously delivered to the chip and pinched injections of the effluents every 20 seconds were employed for chip CE separation. Gradient elution of cHPLC was carried out to obtain the high-efficiency separation. Free-zone electrophoresis was performed with triethylamine buffer to achieve high-speed separation and prevent sample adsorption. Such a simple-made comprehensive system was proved to be effective. The relative standard deviations for migration time and peak height of rhodamine B in 150 sample transfers were 3.2% and 9.8%, respectively. Peptides of the fluorescein isothiocyanate (FITC)-labeled tryptic digests of bovine serum albumin were fairly resolved and detected with this comprehensive 2-D system.  相似文献   

11.
Nowadays, a wide range of pesticides are used in agricultural production, and their monitoring in samples of environmental and alimentary interest is of extreme importance to ensure, among others, the safety of consumption of foods. The aim of this work is to provide updated information about the major developments in CE and HPLC in pesticide analysis, covering relevant publications between 2004 and early 2006. The use of different sample pretreatment steps to provide a suitable extraction of these compounds from the different matrices as well as to increase the sensitivity of the determination is also discussed.  相似文献   

12.
Rapid and reliable methods for the analysis of O- and C-allyl galactopyranosides and glucopyranosides are presented, based on capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC). In MEKC, the formation of chromophoric and charged complexes between the saccharides and borate as well as the hydrophobic interactions with micelles jointly contributed to the selective separation and sensitive detection of all the investigated anomeric couples. Some non-purified synthesis mixtures of C-allyl glycosides were successfully characterised without pre-treatment. MEKC buffer conditions for which glycosides separation was successfully achieved were then exported and applied to reverse-phase liquid chromatography (RP-HPLC), for the quantitative isolation of each allyl glycoside anomer. Identification of the obtained anomeric products was performed by electrospray mass spectrometry and (13)C NMR spectroscopy. Glycoside-solvent interactions driving the selective anomeric separation were shortly addressed and discussed on the basis of sugar derivatives structural differences.  相似文献   

13.
The specificity and rate of cleavage of adrenocorticotrophic hormone (ACTH) peptide bonds by endoproteinase Arg C were analyzed using capillary electrophoresis (CE) and reversed-phase (C18) high-performance liquid chromatography (HPLC). Acidic cleavage products were readily resolved by CE in uncoated capillaries using low ionic strength electrolytes. However, products predicted to have a net positive charge greater than 2 or more than 4 positively charged groups per peptide did not migrate out from the capillary at low ionic strength. Addition of salts and zwitterions to the electrolyte decreased capillary-peptide interactions such that all of the ACTH peptides examined were eluted with high efficiency separation by CE. Commercially obtained endoproteinase Arg C preparations exhibited peptidase activity at Lys-15-Lys16 and at Lys16-Arg17 in addition to the expected cleavage at Arg-X bonds. ACTH peptide bond cleavage rates for Arg8-Trp9, Arg17-Arg-18, Lys15-Lys16, and Lys16-Arg17 were 1.46, 0.096, 0.57, and 0.029 mumol min-1 mg-1 respectively. CE separations generally exhibited better resolution and were accomplished in shorter times than C18 HPLC separations. These properties make CE a particularly appropriate method for kinetic analysis of proteolytic enzyme action on peptide substrates.  相似文献   

14.
To probe separation mechanism and determination with capillary zone electrophoresis (CZE) and liquid chromatography (LC), nine compounds with identical flavanone skeleton were studied. Optimum separation of LC was attained with gradient of acetonitrile and 5mM phosphate buffer (pH 6.9). For CE, electrolyte buffer was 4.5mM SDS in 32mM sodium tetraborate buffer (pH 9.2). The distinguishing feature in this work was successful separation of monohydroxyl stereoisomers by CZE. Polarity is generally increased with hydroxyl groups. In a separation mechanism study, polarity would be reduced by intramolecular hydrogen bond between hydroxyl of C5 and carbonyl group of C4. Comparison of the retention results among monohydroxyl flavanones shows polarity with hydroxyl at C6 the least, and that at C4' and C7 nearly equal. Also, elution order of flavones and flavanones would be adverse due to the hydroxyl at C3 in LC. From the numerical value pK(a) of flavanone, the C7-OH is the smallest, and two hydroxyl groups in an adjacent position is always less than the unique one caused by forming a stable 5-membered ring. Investigation of separation mechanism yield only the effect of constituent but also reasonable explanation for contradictory results between Wulf and our laboratory, this due to the hydroxyl at C3.  相似文献   

15.
High resolution separations of nucleic acids have been performed using high performance capillary electrophoresis (HPCE) and high performance liquid chromatography (HPLC). Electropherograms showing HPCE separations of single and double stranded DNA are presented and compared with HPLC separations. Single base resolution of poly(dA) oligonucleotides in the size range of 12 to 60-mers was achieved in 35 min using HPCE. Plate numbers for HPCE are in the hundreds of thousands and reproducibility is about 1–2 % (RSD). In comparison with HPLC separations, the resolution of nucleic acids obtained using HPCE is much better than that using HPLC, while reproducibility of HPCE is comparable with that of HPLC.  相似文献   

16.
A sensitive and selective high-performance capillary electrophoresis (HPCE) procedure was developed for the determination of total cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using sodium dodecyl sulphate in the run buffers and ultraviolet detection. The concentrations of cicletanine obtained by this method were compared with those obtained by a high-performance liquid chromatographic (HPLC) method used routinely. The within-run precision of the methods, expressed as relative standard deviation, ranged from 1.6 to 7.8% for HPLC and from 6.4 to 11.1% for HPCE. Both methods showed an adequate level of accuracy; the relative errors ranged from 0.02 to 3.25% for HPLC and from 0.21 to 2.90% for HPCE. The HPCE method required less than half the time taken by the HPLC method, making HPCE a useful alternative technique for the routine determination of cicletanine in plasma. Both methods were used to follow the time course of total cicletanine in human plasma after a single oral therapeutic dose of the drug.  相似文献   

17.
The application of ultraviolet detection at 190 nm following chromatography on a Ca2+ cation-exchange column with a mobile phase of water enables the low amounts of carbohydrates present in plasma to be quantitated. The separation and quantitation of carbohydrates in maternal and fetal sheep plasma and amniotic fluid are described, as is the application of this method to the determination of specific radioactivities of glucose and fructose in plasma.  相似文献   

18.
Two novel analytical methodologies using capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) were developed and compared for the determination of benzyldimethyldodecylammonium bromide (BAB) in commercial compound chemical disinfectants. The LC analysis was performed with a Kromasil C18 (200 mm x 4.6 mm, 5 microm) column and a mobile phase of A:B = 80:20 (A: acetonitrile, B: 4 mmol/L octanesulfonic sodium--0.02 mol/L acetic sodium, adjusted with acetic acid to pH 5.2) at a flow rate of 1.0 mL/min. Detection was by ultraviolet absorption at 262 nm. The CE analysis was performed in a bare fused-silica capillary with 75 microm i.d. and total length of 46.4 cm with a buffer solution of 50% acetonitrile -50 mmol/L NaH2PO4, pH 2.24. The applied voltage was 20 kV. Detection was by ultraviolet absorption at 214 nm. Under optimized conditions, the HPLC retention time and CE migration time for BAB was 9.18 and 5.08 min, respectively. Calibration curves of peak area versus concentration gave correlation coefficients of 0.9996 for HPLC and 0.9994 for CE. The detection limits for HPLC and CE were 1.6 mg/L and 0.2 mg/L, respectively. Average recoveries at three concentration levels (50, 100, 200 mg/L for HPLC: 20, 40, 100 mg/L for CE) were 99.94 +/- 1.5, 99.64 +/- 1.3 and 99.61 +/- 0.4% for HPLC and 120.47 +/- 2.6, 102.06 +/- 8.7 and 103.05 +/- 3.0% for CE, respectively. Although both methods were shown to be suitable for the determination of BAB in commercial disinfectant compounds, CE provided analysis with less solvent purchase/disposal and better column efficiency, whereas HPLC provided superior precision.  相似文献   

19.
Two methods, based on the use of capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), respectively, were developed for the analysis of the atypical antipsychotic aripiprazole in plasma of schizophrenic patients for therapeutic drug monitoring purposes. Good analytical performances were obtained with the CE method, using uncoated fused silica capillaries and a background electrolyte composed of 50 mM phosphate buffer at pH 2.5. With 20 kV voltage, aripiprazole was detectable at 214 nm within 5 min. The second analytical method, based on HPLC with diode array detection, employed a C8 reversed-phase column and a mixture of a 12.5 mM phosphate buffer, pH 3.5, containing triethylamine and acetonitrile as the mobile phase. Aripiprazole was detected at 254 nm and a complete chromatographic run lasted about 10 min. For both analytical methods loxapine was used as the internal standard and the same plasma sample pre-treatment by means of solid-phase extraction on cyano cartridges was carried out, with extraction yield values always higher than 91.3%. Linear responses for aripiprazole were obtained between 70 and 700 ng mL−1 and precision assays (expressed as relative standard deviation values) were lower than 7.0%. After validation, both methods were successfully applied to human plasma samples drawn from schizophrenic patients undergoing therapy with Abilify® tablets. Accuracy was satisfactory, with recovery value higher than 91.0%.  相似文献   

20.
Summary A micellar electrokinetic chromatography method is presented which permits separation of cefotaxime and its major related impurities. Separation was carried out at 15 kV, using 30 mM sodium dihydrogen phosphate adjusted to pH 7.2 with 5 M NaOH and which contained 165 mM sodium dodecylsulfate as electrolyte. Results obtained by capillary electrophoresis were in good agreement with those of high-performance liquid chromatography with respect to the level of the major known impurities, total impurity content and cefotaxime purity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号