首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
We demonstrate the capabilities of a highly parallel, active pixel detector for large-area, mass spectrometric imaging of biological tissue sections. A bare Timepix assembly (512?×?512 pixels) is combined with chevron microchannel plates on an ion microscope matrix-assisted laser desorption time-of-flight mass spectrometer (MALDI TOF-MS). The detector assembly registers position- and time-resolved images of multiple m/z species in every measurement frame. We prove the applicability of the detection system to biomolecular mass spectrometry imaging on biologically relevant samples by mass-resolved images from Timepix measurements of a peptide?Cgrid benchmark sample and mouse testis tissue slices. Mass-spectral and localization information of analytes at physiologic concentrations are measured in MALDI-TOF-MS imaging experiments. We show a high spatial resolution (pixel size down to 740?×?740?nm2 on the sample surface) and a spatial resolving power of 6???m with a microscope mode laser field of view of 100?C335???m. Automated, large-area imaging is demonstrated and the Timepix?? potential for fast, large-area image acquisition is highlighted.  相似文献   

2.
The mobilities of electrosprayed proteins and protein multimers with molecular weights ranging from 12.4 kDa (cytochrome C monomers) to 154 kDa (nonspecific concanavalin A hexamers) were measured in dry air by a planar differential mobility analyzer (DMA) coupled to a time-of-flight mass spectrometer (TOF-MS). The DMA determines true mobility at atmospheric pressure, without perturbing ion structure from that delivered by the electrospray. A nondenaturing aqueous 20 mM triethylammonium formate buffer yields compact ions with low charge states, moderating polarization effects on ion mobility. Conversion of mobilities into cross-sections involves a reduction factor ξ for the actual mobility relative to that associated with elastic specular collisions with smooth surfaces. ξ is known to be 1.36 in air from Millikan’s oil drop experiments. A similar enhancement effect ascribed to atomic-scale surface roughness has been found in numerical simulations. Adopting Millikan’s value ξ = 1.36 and assuming a spherical geometry yields a gas-phase protein density ρ p = 0.949 ± 0.053 g cm−3 for all our protein data. This is substantially higher than the 0.67 g cm−3 found in recent low-resolution DMA measurements of singly charged proteins. DMA-MS can distinguish nonspecific protein aggregates formed during the electrospray process from those formed preferentially in solution. The observed charge versus diameter relation is compatible with a protein charge reduction mechanism based on the evaporation of triethylammonium ions from electrosprayed drops.  相似文献   

3.
Serotonin emerges as crucial neurotransmitter and hormone in a growing number of different physiologic processes. Besides extensive serotonin production previously noted in patients with metastatic carcinoid tumors, serotonin now is implicated in liver cell regeneration and bone formation. The aim was to develop a rapid, sensitive, and highly selective automated on-line solid-phase extraction method coupled to high-performance liquid chromatography–tandem mass spectrometry (XLC-MS/MS) to quantify low serotonin concentrations in matrices such as platelet-poor plasma and urine. Fifty microliters plasma or 2.5 μL urine equivalent were pre-purified by automated on-line solid-phase extraction, using weak cation exchange. Chromatography of serotonin and its deuterated internal standard was performed with hydrophilic interaction chromatography. Mass spectrometric detection was operated in multiple reaction monitoring mode using a quadrupole tandem mass spectrometer with positive electrospray ionization. Serotonin concentrations were determined in platelet-poor plasma of metastatic carcinoid patients (n = 23) and healthy controls (n = 22). Urinary reference intervals were set by analyzing 24-h urine collections of 120 healthy subjects. Total run-time was 6 min. Intra- and inter-assay analytical variation were <10%. Linearity in the 0–7300 μmol/L calibration range was excellent (R2 > 0.99). Quantification limits were 30 and 0.9 nmol/L in urine and plasma, respectively. Platelet-poor serotonin concentrations in metastatic carcinoid patients were significantly higher than in controls. The urinary reference interval was 10–78 μmol/mol creatinine. Serotonin analysis with sensitive and specific XLC-MS/MS overcomes limitations of conventional HPLC. This enables accurate quantification of serotonin for both routine diagnostic procedures and research in serotonin-related disorders.  相似文献   

4.
A new procedure is described for the derivatization by silylation of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) present in urine, followed by analysis using gas chromatography–tandem mass spectrometry. A conventional procedure for derivatization of the analyte was evaluated using two types of experimental design. A 23 factorial design considered the parameters temperature, reaction time, and the solvent/derivatization agent ratio. A central composite design (CCD) was applied to optimize the values of the significant variables. The optimum conditions were a reaction temperature of 50 °C, a reaction time of 30 min, and a BSTFA/acetone ratio of 40:20. The use of imidazole as a catalyst, together with ultrasonication, reduced the reaction time to 5 min and increased the efficiency of derivatization of THCCOOH, compared with the conventional method. The operating conditions of the tandem mass spectrometer were also optimized. The method was linear in the concentration range 1–50 ng mL−1 (R 2 = 0.9951). Intra- and inter-day precisions were 7.7–12.3% and 11.1–13.9%, respectively, recoveries ranged between 91 ± 8% and 101 ± 12%, accuracy (as % bias) was between –11.7% and +0.7%, and limits of detection and quantification were 0.5 and 1.0 ng mL−1, respectively.  相似文献   

5.
The azaspiracids are a family of lipophilic polyether marine biotoxins that have caused a number of human intoxication incidents in Europe since 1995 after consumption of contaminated shellfish (Mytilus edulis). Levels of azaspiracids in shellfish for human consumption are monitored in accordance with EU guidelines: only shellfish with less than 160 μg kg−1 are deemed safe. The limited availability of commercially available standards for azaspiracids is a serious problem, because validated LC–MS methods are required for routine analysis of these toxins in shellfish tissues. The procedure described herein has been used for the separation and the isolation of four azaspiracid (AZA) toxins from shellfish, for use as LC–MS–MS reference materials. Five separation steps have been used to isolate azaspiracids 1, 2, 3, and 6. The purity of the toxins obtained has been confirmed by multiple mass spectrometric methods using authentic azaspiracid standards. The same techniques have been used for quantification of the toxins extracted. The isolation procedure involves several chromatographic purification techniques: solid-phase extraction (diol sorbent, 90% mass reduction, and 95 ± 1% toxin recovery); Sephadex size-exclusion chromatography (87% mass reduction and up to 95 ± 2% toxin recovery), Toyopearl HW size-exclusion chromatography (90% mass reduction and up to 92.5 ± 2.5% toxin recovery), and semi-preparative LC (78 ± 3% toxin recovery). The procedure effectively separates the toxins from the sample matrix and furnishes azaspiracid toxins (AZA1, AZA2, AZA3 and AZA6) of sufficient purity with an average yield of 65% (n = 5). Triple-quadrupole mass spectrometry was used for qualitative and quantitative monitoring of the isolation efficiency after each stage of the process. High-resolution mass spectrometric evaluation of the toxic isolated material in both positive and negative modes suggests high purity.  相似文献   

6.
Saturated and unsaturated, linear, branched, and cyclic hydrocarbons, as well as polyaromatic and heteroaromatic hydrocarbons, were successfully ionized by atmospheric pressure chemical ionization (APCI) using small hydrocarbons as reagents in a linear quadrupole ion trap (LQIT) mass spectrometer. Pentane was proved to be the best reagent among the hydrocarbon reagents studied. This ionization method generated different types of abundant ions (i.e., [M + H]+, M+•, [M – H]+ and [M – 2H]+ •), with little or no fragmentation. The radical cations can be differentiated from the even-electron ions by using dimethyl disulfide, thus facilitating molecular weight (MW) determination. While some steroids and lignin monomer model compounds, such as androsterone and 4-hydroxy-3-methoxybenzaldehyde, also formed abundant M+• and [M + H]+ ions, this was not true for all of them. Analysis of two known mixtures as well as a base oil sample demonstrated that each component of the known mixtures could be observed and that a correct MW distribution was obtained for the base oil. The feasibility of using this ionization method on the chromatographic time scale was demonstrated by using high-performance liquid chromatography (HPLC) with hexane as the mobile phase (and APCI reagent) to separate an artificial mixture prior to mass spectrometric analysis.  相似文献   

7.
A method is demonstrated for analysis of vitamin D fortified dietary supplements that eliminates virtually all chemical pretreatment prior to analysis, which is referred to as a “dilute-and-shoot” method. Three mass spectrometers, in parallel, plus a UV detector, an evaporative light-scattering detector (ELSD), and a corona charged aerosol detector (CAD) were used to allow a comparison of six detectors simultaneously. Ultraviolet data were analyzed using internal standard, external standard, and response factor approaches. The contents of gelcaps that contained 2,000 IU (50 μg) vitamin D3 in rice bran oil, diluted to 100 mL, were analyzed without the need for lengthy saponification and extraction. Vitamin D3 was analyzed using UV detection, extracted ion chromatograms, selected ion monitoring (SIM) atmospheric pressure chemical ionization mass spectrometry (APCI-MS), and two transitions of multiple reaction monitoring (MRM) APCI-MS. The internal standard, external standard, and response factor methods gave values of 0.5870 ± 0.0045, 0.5893 ± 0.0041, and 0.5889 ± 0.0045 μg/mL, respectively, by UV detection. The values obtained by MS were 0.6117 ± 0.0140, 0.6018 ± 0.0244, and 0.5848 ± 0.0146 μg/mL by SIM and two transitions of MRM, respectively. The triacylglycerols in the oils were analyzed using full-scan APCI-MS, electrospray ionization (ESI) MS, up to MS4, an ELSD, and a CAD. The method proved to be very sensitive for vitamin D3, as well as triacylglycerols (TAGs), allowing identification of intact TAGs containing fatty acids up to 28 carbons in length. LC-ESI-MS of glycerin polymers is also demonstrated.  相似文献   

8.
In mass spectrometry imaging, spatial resolution is pushed to its limits with the use of ion microscope mass spectrometric imaging systems. An ion microscope magnifies and then projects the original spatial distribution of ions from a sample surface onto a position-sensitive detector, while retaining time-of-flight mass separation capabilities. Here, a new type of position-sensitive detector based on a chevron microchannel plate stack in combination with a 512 × 512 complementary metal-oxide-semiconductor based pixel detector is coupled to an ion microscope. Spatial resolving power better than 6 μm is demonstrated by secondary ion mass spectrometry and 8–10μm spatial resolving power is achieved with laser desorption ionization. A detailed evaluation of key performance criteria such as spatial resolution, acquisition speed, and data handling is presented.  相似文献   

9.
An electrospray ionization tandem mass spectrometric (ESI-MS-MS) method has been developed for the determination of cyanide (CN) in blood. Five microliters of blood was hemolyzed with 50 μL of water, then 5 μL of 1 M tetramethylammonium hydroxide solution was added to raise the pH of the hemolysate and to liberate CN from methemoglobin. CN was then reacted with NaAuCl4 to produce dicyanogold, Au(CN)2, that was extracted with 75 μL of methyl isobutyl ketone. Ten microliters of the extract was injected directly into an ESI-MS-MS instrument and quantification of CN was performed by selected reaction monitoring of the product ion CN at m/z 26, derived from the precursor ion Au(CN)2 at m/z 249. CN could be measured in the quantification range of 2.60 to 260 μg/L with the limit of detection at 0.56 μg/L in blood. This method was applied to the analysis of clinical samples and the concentrations of CN in the blood were as follows: 7.13 ± 2.41 μg/L for six healthy non-smokers, 3.08 ± 1.12 μg/L for six CO gas victims, 730 ± 867 μg for 21 house fire victims, and 3,030 ± 97 μg/L for a victim who ingested NaCN. The increase of CN in the blood of a victim who ingested NaN3 was confirmed using MS-MS for the first time, and the concentrations of CN in the blood, gastric content and urine were 78.5 ± 5.5, 11.8 ± 0.5, and 11.4 ± 0.8 μg/L, respectively.  相似文献   

10.
Flexible electrode architectures based on non-functionalized (P2) and functionalized (P3) single-walled carbon nanotubes (SWNTs) were fabricated via a simple vacuum filtration process. A hybrid layer of various compositions of P2- and P3-SWNTs forms free-standing membranes (~80 μm in thickness), and their electrochemical performance was evaluated as an air electrode AEP2/P3 in zinc–air batteries. Such bifunctionalized air electrodes showed uniform surface morphology with interconnected micron-sized porous structure with high porosity (~70%). The N2 adsorption isotherms at 77 K are of type IV with BET-specific surface areas of AE(60/40) and AE(80/20) to be 130.54 and 158.76 m2 g−1, respectively, thus facilitates high active surface area for active oxygen reduction/evolution reactions. BJH pore size distribution of AE(60/40) and AE(80/20) shows maximum pores with diameter <15 nm. The zigzag interlaying of the SWNTs imparts mechanical stability and flexibility in zinc–air batteries. Zinc–air batteries with optimized compositions of P2- and P3-SWNTs in air electrode AE(60/40) had ionic conductivity ~1 × 10−2 S cm−1 and delivered higher discharge capacity ~300 mAh g−1 as compared to AE(80/20) composition. The unique properties of AE(P2/P3) studied in this work would enable flexible air electrode architectures in future metal–air batteries.  相似文献   

11.
Scanning probe techniques enable direct imaging of morphology changes associated with cellular processes at life specimen. Here, glutaraldehyde-fixed and living alveolar type II (ATII) cells were investigated by atomic force microscopy (AFM), and the obtained topographical data were correlated with results obtained by scanning electron microscopy (SEM) and confocal microscopy (CM). We show that low-force contact mode AFM at glutaraldehyde-fixed cells provides complementary results to SEM and CM. Both AFM and SEM images reveal fine structures at the surface of fixed cells, which indicate microvilli protrusions. If ATII cells were treated with Ca2+ channel modulators known to induce massive endocytosis, changes of the cell surface topography became evident by the depletion of microvilli. Low force contact mode AFM imaging at fixed ATII cells revealed a significant reduction of the surface roughness for capsazepine and 2-aminoethoxydiphenyl-borate (CPZ/2-APB)-treated cells compared to untreated control cells (Rc of 99.7 ± 6.8 nm vs. Rc of 71.9 ± 4.6 nm for N = 22), which was confirmed via SEM studies. CM of microvilli marker protein Ezrin revealed a cytoplasmic localization of Ezrin in CPZ/2-APB-treated cells, whereas a submembranous Ezrin localization was observed in control cells. Furthermore, in situ AFM investigations at living ATII cells using low force contact mode imaging revealed an apparent decrease in cell height of 17% during stimulation experiments. We conclude that a dynamic reorganization of the microvillous cell surface occurs in ATII cells at conditions of stimulated endocytosis.  相似文献   

12.
The development of a simple and rapid high-performance liquid chromatography (HPLC) method for the determination of the new antiepileptic drug rufinamide (RFN) in human plasma and saliva is reported. Samples (250 μl) are alkalinized with ammonium hydroxide (pH 9.25) and extracted with dichloromethane using metoclopramide as internal standard. Separation is achieved with a Spherisorb silica column (250 × 4.6 mm i.d., 5 μm) at 30 °C using as mobile phase a solution of methanol/dichloromethane/n-hexane 10/25/65 (vol/vol/vol) mixed with 6 ml ammonium hydroxide. The instrument used was a Shimadzu LC-10Av chromatograph and flow rate was 1.5 ml min-1, with a LaChrom L-7400 UV detector set at 230 nm. Calibration curves are linear [r 2 = 0.998 ± 0.002 for plasma (n = 10) and r 2 = 0.999 ± 0.001 for saliva (n = 9)] over the range of 0.25–20.0 μg ml-1, with a limit of quantification at 0.25 μg ml-1. Precision and accuracy are within current acceptability standards. The assay is suitable for pharmacokinetic studies in humans and for therapeutic drug monitoring.  相似文献   

13.
An ion mobility spectrometer (IMS) probe system for real-time, subsurface soil-gas sampling applications is presented. The system includes an IMS and supporting electronics encased in a 51 mm diameter stainless steel probe housing. The IMS was challenged in the laboratory with 2,6-di-tert-butylpyridine (DtBP) and tetrachloroethylene (PCE) in zero air yielding reduced ion mobility constants (Ko) values of 1.42 cm2/Vs (n = 3) and 1.79 ± 0.01 cm2/Vs (n = 3), respectively. A resolving power of 38 and 31 was obtained for DtBP and PCE, respectively. The system was deployed at a PCE-contaminated site to demonstrate its performance under field conditions. PCE was detected in the vapor samples as evidenced by peaks with a Ko value of 1.80 ± 0.01 cm2/Vs for two measurements that were taken 6 min apart. The presence of PCE at the contaminated site was confirmed by GC-MS analysis of a gas sample at an EPA-certified laboratory, suggesting that this IMS system can be used to detect PCE under field conditions.  相似文献   

14.
X-ray spectrometric technique has been described to determine the X-ray mass attenuation coefficient, μ/ρ, of X-rays employing HPGe X-ray detector and radioactive sources. The photon intensity is measured by gating the channel of the spectrometer at FWHM/photo peak. Using the technique the “best value” values of μ/ρ were obtained for those thicknesses which lie in the transmission (T) range 0.5 ≥ T ≥ 0.02. Total attenuation cross sections for other elements and lead compounds were measured at photon energies from 17 to 88 keV to study the Bragg’s additivity law near the absorption edge of the lead. The measured values of mass attenuation coefficient values are compared with theoretical values obtained using Winxcom (programme). This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 17–23%.  相似文献   

15.
A rapid and simple miniaturized liquid–liquid extraction method has been developed for the determination of topramezone in soil, corn, wheat, and water samples using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-electrospray ionization (ESI)/MS/MS). The established method for the extraction and purification procedure was based on liquid–liquid partitioning into an aqueous solution at a low pH (pH ≈ 2.5), followed by back-partitioning into water at pH > 9. Two precursor, product ion transitions for topramezone were measured and evaluated to provide the maximum degree of confidence in the results. Under negative ESI conditions, quantitation was achieved by monitoring the fragment at m/z = 334 and the qualitative fragment at m/z = 318, whereas also collecting the corresponding parent ion at m/z = 362. Chromatographic separation was achieved using gradient elution with a mobile phase consisting of methanol and a 0.01% aqueous ammonium hydroxide solution. Recovery studies for soil, corn, wheat, and water were conducted at four different topramezone concentrations (5 or 10, 50, 100, and 1,000 μg kg−1); the overall average recoveries ranged from 79.9% to 98.4% with intra-day relative standard deviations (RSD) of 3.1~8.7% and inter-day RSD of 4.3~7.5%. Quantitative results were determined from calibration curves of topramezone standards containing 1–500 μg L−1 with an R 2 ≥ 0.9994. Method sensitivities expressed as limits of quantitation were typically 6, 8, 9, and 1 μg kg−1 in soil, corn, wheat, and water, respectively. The results of the method validation confirmed that this proposed method was convenient and reliable for the determination of topramezone residues in soil, corn, wheat, and water.  相似文献   

16.
Due to technological advancement, environment suffers from untreated toxic heavy metal bearing effluent coming from different industries. Chromium (VI) is one of those heavy metals having adverse impact on ecological balance, human, and plant health because of its carcinogenic properties. Biosorption is presented as an alternative to traditional technologies which are costly and inefficient for treatment of industrial wastes containing low amount of heavy metals. In this study, bioremediation of Cr (VI) ions by immobilized Bacillus cereus M1 16 was investigated in a laboratory scale packed bed up-flow column reactor. The effect of important parameters, such as the inlet flow rate, influent concentration, and effective bed height, has been studied. External mass transfer, surface adsorption, and intrabead mass transfer were also studied to conclude the rate limiting step for removal of Cr (VI) and to determine the process parameters which are important for biosorption optimization. The external mass transfer coefficient was calculated at different flow rates (6.51 × 10−2 to 7.58 × 10−2 cm/min). Using the model, the surface adsorption rate constant (k ad) and the intrabead mass transfer coefficient (k i) were predicted as 0.0267 × 10−3 and 0.7465 × 10−3 l/g/min, respectively. Both are much lower than the external mass transfer coefficient (k e). The surface adsorption phenomenon is acting as the rate-limiting step due to its high resistance for removal of Cr (VI).  相似文献   

17.
The study of polished cross sections is a well-assessed and practical method to investigate the stratigraphy of paintings and multilayer polychromies on works of art, in general. Analyses on cross sections allow us to characterize, at once, all the layers in the stratigraphy, giving information about the artists technique, the number of layers and their composition and sometimes about the conservation history of the artefact. In this paper, the application of an imaging detector focal plane array (FPA) coupled to an infrared (IR) microscope has been studied, focusing on the characteristics and potential of the different working methodologies (attenuated total reflectance (ATR) and total reflection). FPA detector coupled with ATR crystal can “localize” IR information coming from a 30 × 30μm sample area, in a 64 × 64 dot matrix detector. In particular, an innovative analysis methodology has been tested for the total reflectance measurements in order to obtain maximum information with single measurements. Micro-infrared total reflection measurements have been carried out in an extended IR range (from 1,000 to 5,266 cm−1) exploiting the broad spectral response of mercury cadmium telluride detector in order to include overtones and combination bands from near-infrared spectral range without any modification of the standard mid-infrared micro-FT instrumentation. The potentialities of this new approach have been successfully transferred in the imaging/mapping investigations with a minimal tuning of the apparatus. Results obtained on a polished cross section coming from a modern painting and on a micro-sample of a wood polychromy from an undated historic polyptic are shown for demonstration.  相似文献   

18.
Small interfering ribonucleic acid (siRNA) molecules can effect the expression of any gene by inducing the degradation of mRNA. Therefore, these molecules can be of interest for illicit performance enhancement in sports by affecting different metabolic pathways. An example of an efficient performance-enhancing gene knockdown is the myostatin gene that regulates muscle growth. This study was carried out to provide a tool for the mass spectrometric detection of modified and unmodified siRNA from plasma samples. The oligonucleotides are purified by centrifugal filtration and the use of an miRNA purification kit, followed by flow-injection analysis using an Exactive mass spectrometer to yield the accurate masses of the sense and antisense strands. Although chromatography and sensitive mass spectrometric analysis of oligonucleotides are still challenging, a method was developed and validated that has adequate sensitivity (limit of detection 0.25–1 nmol mL−1) and performance (precision 11–21%, recovery 23–67%) for typical antisense oligonucleotides currently used in clinical studies.  相似文献   

19.
SiO2/ZrO2/C carbon ceramic material with composition (in wt%) SiO2 = 50, ZrO2 = 20, and C = 30 was prepared by the sol–gel-processing method. A high-resolution transmission electron microscopy image showed that ZrO2 and the graphite particles are well dispersed inside the matrix. The electrical conductivity obtained for the pressed disks of the material was 18 S cm−1, indicating that C particles are also well interconnected inside the solid. An electrode modified with flavin adenine dinucleotide (FAD) prepared by immersing the solid SiO2/ZrO2/C, molded as a pressed disk, inside a FAD solution (1.0 × 10−3 mol L−1) was used to investigate the electrocatalytic reduction of bromate and iodate. The reduction of both ions occurred at a peak potential of −0.41 V vs. the saturated calomel reference electrode. The linear response range (lrr) and detection limit (dl) were: BrO3 , lrr = 4.98 × 10−5–1.23 × 10−3 mol L−1 and dl = 2.33 μmol L−1; IO3 , lrr = 4.98 × 10−5 up to 2.42 × 10−3 and dl = 1.46 μmol L−1 for iodate.  相似文献   

20.
A commercial hybrid quadrupole time–of–flight mass spectrometer has been modified for high-speed matrix-assisted laser desorption ionisation (MALDI) imaging using a short-pulse optical technology Nd:YVO4 laser. The laser operating in frequency-tripled mode (λ = 355 nm) is capable of delivering 1.5-ns pulses of energy at up to 8 μJ at 5–10 kHz and 3 μJ at 20 kHz. Experiments to improve beam homogeneity and reduce laser speckle by mechanical vibration of the fibre-optic laser delivery system are reported along with data from trial and tissue imaging experiments using the modified instrument. The laser appeared to yield best results for MALDI-MS imaging experiments when operating at repetition rates 5–10 kHz. Combining this with raster imaging allowed images of rat brain sections to be recorded in 37 min. Similarly, images of the distribution of peptides in “on-tissue” digest experiments from tumour tissues were recorded in 1 h and 30 min rather than the 8-h acquisition time previously used. A brief investigation of targeted protein analysis/imaging by multiple reaction monitoring experiments “on-tissue” is reported. A total of 26 transitions were recorded over a 3-s cycle time and images of abundant proteins were successfully recorded.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号