首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 0 毫秒
1.
Dan Luo  Fei Chen  Yu-Qi Feng 《Talanta》2009,77(5):1701-3016
A method was developed for the determination of Δ9-Tetrahydrocannabinol (THC) in saliva by polymer monolith microextraction (PMME) combined with gas chromatography-mass spectrometry. The poly(methacrylic acid-co-ethylene glycol dimethacrylate) (p(MAA-co-EGDMA)) monolithic capillary column was selected as the extraction medium of PMME, which showed high extraction capacity towards THC in saliva. To reach optimum PMME extraction performance, several PMME parameters were investigated, including matrix pH, flow rate for extraction, sampling volume and elution solvent. Under the optimal conditions, good extraction efficiency was obtained with no matrix interference in the process of extraction and the subsequent GC-MS analysis. In the selected-ion monitoring (SIM) mode, the limit of detection (LOD) for THC was 0.68 ng/mL. The linearity range of the method was 3-300 ng/mL. Excellent reproducibility of the method was exhibited by intra- and inter-day precisions, yielding the relative standard deviations (R.S.D.s) less than 12%; recoveries higher than 89%. The proposed method was proved to be rapid, sensitive, and competently applied to the determination of THC in saliva samples.  相似文献   

2.
For the detection of the major active component of cannabis, Δ9-tetrahydrocannabinol (THC) in aqueous samples, a homogeneous competitive immunoassay based on fluorescence quenching induced by fluorescence resonance energy transfer (FRET) has been developed. The fluorescence of anti-THC-antibody, labeled with fluorescence dye DY-481XL, can be quenched after its binding to THC-BSA-quencher conjugate (bovine serum albumin coupled with THC and another fluorescence dye, DYQ-661, as quencher). This quenching effect is inhibited when the antibodies bind to free THC in aqueous sample, thus competing for binding sites with the THC-BSA-quencher conjugate. The extent of the inhibition corresponds to the concentration of THC in the samples. The assay principle is simple and the test duration is within 10 min. The detection limit for THC in buffer was 2 ng mL−1. In pooled saliva samples a detection limit of 50 ng mL−1 was achieved.  相似文献   

3.
This review briefly depicts several salient points of the current status of knowledge on salivary peptidoma. It outlines the intrinsic difficulties in its characterization connected to different factors of variability, such as: i) the high genetic polymorphisms, complicated by individual insertions/deletions and alternative splicing; ii) complex post-translational maturations comprehending different proteolytic cleavages, glycosylation, phosphorylation and sulfation processes; iii) physiological variations and different contributions to the whole. Moreover, several technological and analytical problems and pitfalls that had to be surmounted during our studies focussed on the extensive qualitative and quantitative characterization of salivary peptidoma and mainly based on LC-MS analyses of intact naturally occurring peptides are here described. The hope is that the information provided might be helpful to other groups engaged on the analysis of saliva or other body fluids for clinical applications.  相似文献   

4.
This study describes a new strategy for real-time detection of alcohol in saliva and sweat. Phosphotungstic acid (PTA) is a colorless, photoelectrochromic heteropoly acid that can be reduced by ethanol under ultraviolet (UV) radiation to produce an intense blue color. This system has useful properties in the development of a new alcohol sensor: (1) the blue color can be detected by the naked eye or mobile camera, even at low ethanol concentrations; (2) color intensity is proportional to ethanol concentration; and (3) once exposed to air, reduced PTA is subsequently oxidized and returns to its colorless state offering sensor reusability. Based on these properties, we developed a simple device consisting of a PTA-impregnated non-woven material and a low-cost UV lamp that can be used to evaluate the alcohol concentration in saliva and sweat. We further enhanced the practical applicability of this sensor by demonstrating the integration of digital image analysis, multivariate analysis, and mobile camera technology with this sensor. This device can be potentially used in vehicles as a convenient, reusable alcohol sensor for drivers.  相似文献   

5.
A first attempt to automate the effervescence assisted dispersive liquid–liquid microextraction (EA-DLLME) has been reported. The method is based on the aspiration of a sample and all required aqueous reagents into the stepwise injection analysis (SWIA) manifold, followed by simultaneous counterflow injection of the extraction solvent (dichloromethane), the mixture of the effervescence agent (0.5 mol L−1 Na2CO3) and the proton donor solution (1 mol L−1 CH3COOH). Formation of carbon dioxide microbubbles generated in situ leads to the dispersion of the extraction solvent in the whole aqueous sample and extraction of the analyte into organic phase. Unlike the conventional DLLME, in the case of EA-DLLME, the addition of dispersive solvent, as well as, time consuming centrifugation step for disruption of the cloudy state is avoided. The phase separation was achieved by gentle bubbling of nitrogen stream (2 mL min−1 during 2 min).  相似文献   

6.
A simultaneous determination method for the enantiomers of chiral carboxylic acids by the combination of ultraperformance liquid chromatography and mass spectrometry (UPLC-MS/MS) has been developed. (S)(+)-1-(2-Pyrrolidinylmethyl)-pyrrolidine (S-PMP) was used as the derivatization reagent for the high-throughput determination of biological chiral carboxylic acids, i.e., lactic acid (LA) and 3-hydroxybutyric acid (HA). The S-PMP efficiently reacted with the carboxylic acids under mild conditions at room temperature in the presence of 2,2'-dipyridyl disulfide and triphenylphosphine. The resulting S-PMP derivatives were highly responsive in the electrospray ionization (ESI)-MS operating in the positive-ion mode and gave characteristic product ions during the MS/MS, which enabled the sensitive detection using selected reaction monitoring. The derivatization was effective for the enantiomeric separation of the chiral carboxylic acids, and the resolution values of DL-LA and DL-HA were 4.91 and 9.37, respectively. Furthermore, a rapid separation of the derivatives of DL-LA and DL-HA within 7?min was performed using the UPLC system. The limits of detection on the column were in the low femtogram range (5-12?fg). The proposed procedure was successfully applied for the determination of the D- and L-isomers of LA and HA in the saliva of diabetes mellitus (DM) patients and healthy volunteers. The D-LA in DM patients was clearly higher than that in normal subjects. The derivatization followed by UPLC-ESI-MS/MS enabled the enantiomeric separation and detection of trace amounts of LA and HA in human saliva with a simple pretreatment and small sample volume.  相似文献   

7.
We have developed a simple and sensitive method for the simultaneous determination of testosterone (TES), cortisol (CRT), and dehydroepiandrosterone (DHEA) in saliva by automated online in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) using a Discovery HS F5 column. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Supel-Q PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The in-tube SPME LC–MS/MS method showed good linearity with correlation coefficients r?≥?0.9998 for TES, CRT, and DHEA using their respective stable isotope-labeled internal standards. The intra-day and inter-day precisions (relative standard deviations) were below 4.9 and 8.5 % (n?=?5), respectively. This method was successfully utilized to analyze TES, CRT, and DHEA in saliva samples without any other pretreatment or interference peaks, and the quantification limits (S/N?=?10) of TES, CRT and DHEA were about 0.01, 0.03 and 0.29 ng/mL saliva, respectively. The recoveries of these compounds spiked into saliva samples were each above 94 %. This method was applied to analyze changes in salivary TES, CRT, and DHEA levels resulting from stress and fatigue load.  相似文献   

8.
Due to recent legalization of marijuana across many states in the U.S., there is an increased concern of users driving while impaired/intoxicated with Δ9-tetrahydrocannabinol (Δ9-THC), the principal psychoactive constituent of cannabis/marijuana. Hence, there is a need for a rapid roadside detection of this drug that can be used to accurately screen drivers. Current field sobriety tests rely on a series of physical and mental exercises administered during DUI investigations to help determine a driver's level of impairment. Due to their portability and effectiveness, screen printed carbon electrodes (SPCEs) are ideal to work with when it comes to devising a low-cost screening device for roadside testing. SPCE's can potentially detect low levels of Δ9-THC in an individual's saliva via electrochemical oxidation of Δ9-THC. Herein we report a fast, cheap, and accurate approach to electrochemically detect 1–20 μM Δ9-THC in a 1 mL sample of artificial oral fluid (AF-OF) diluted to 50 % with a buffer/electrolyte solution using differential pulse voltammetry (DPV) at the surface of a small SPCE. Implications for the use of this method to screen intoxicated drivers are discussed.  相似文献   

9.
Mass spectrometry has become a popular analytical tool because of its high sensitivity and specificity. The use of a chiral derivatization reagent for the mass spectrometry (MS) detection seems to be efficient for the enantiomeric separation of racemates. However, the number of chiral reagents for the liquid chromatography (LC)–MS/MS analysis is very limited. According to these observations, we are currently in the process of developing novel labeling reagents for chiral molecules in MS/MS analysis. The derivatization reagent that is effective for enhancing not only the electrospray ionization–MS/MS sensitivity but also the reversed-phase LC resolution of carboxylic acid enantiomers should have a highly proton-affinitive moiety and an asymmetric structure near the reactive functional group. Furthermore, the resulting derivative has to provide a characteristic product ion suitable for the selected reaction monitoring. Based upon these considerations, a series of prolylamidepyridines ((S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-2-yl)amide (PCP2), (S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-3-yl)amide, and (S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-4-yl)amide) was synthesized as ideal labeling reagents for the enantioseparation of chiral carboxylic acids and evaluated in terms of separation efficiency and detection sensitivity by ultra-performance LC (UPLC)–MS/MS. Among the synthesized reagents, PCP2 was the most efficient chiral derivatization reagent for the enantioseparation of carboxylic acid. The Rs values and the detection limits of the derivatives of non-steroidal anti-inflammatory drugs, which were selected as the representative carboxylic acids, were in the range of 2.52–6.07 and 49–260 amol, respectively. The sensitive detection of biological carboxylic acids (detection limits, 32–520 amol) was also carried out by the proposed method using PCP2 and UPLC–MS/MS. The PCP2 was applied to the determination of carboxylic acids in human saliva. Several biological carboxylic acids, such as lactic acid (LA), 3-hydroxybutylic acid, maric acid, succinic acid, α-ketoglutalic acid, and citric acid, were clearly identified in the saliva of healthy persons and diabetic patients. Furthermore, the ratio of d-LA in diabetic patients was higher than that in normal subjects. Judging from these results, PCP2 seems to be a useful chiral derivatization reagent for the determination not only of chiral, but also achiral, carboxylic acids in real samples.
Figure
Labeling reagent for carboxylic acids in chiral metabolomics study  相似文献   

10.
A novel triazine-type chiral derivatization reagent, i.e., (S)-2,5-dioxopyrrolidin-1-yl-1-(4,6-dimethoxy-1,3,5-triazin-2-yl) pyrrolidine-2-carboxylate (DMT-(S)-Pro-OSu), was developed for the highly sensitive and selective detection of chiral amines and amino acids by UPLC–MS/MS analysis. The enantiomers of amino acids were easily labeled with the reagents at room temperature within 40 min in an alkaline medium containing triethylamine. The diastereomers derived from proteolytic amino acids, except serine, were well separated under isocratic elution conditions by reversed-phase chromatography using an ODS column (Rs = 1.2–9.0). dl-Serine was separated by use of an ADME column which has relatively higher polar surface than the conventional ODS column. The characteristic product ions, i.e., m/z 195.3 and m/z 209.3, were detected from all the diastereomers by the collision-induced dissociation of the protonated molecule. A highly sensitive detection on the amol–fmol level was obtained from the selected reaction monitoring (SRM) chromatogram. The chiral amines (e.g., adrenaline and noradrenaline) labeled with DMT-(S)-Pro-OSu were also well separated and sensitively detected by the present procedure. The method using DMT-(S)-Pro-OSu was used for the determination of dl-amino acids in the human saliva from healthy volunteers. Various l-amino acids were identified in the saliva. Furthermore, d-alanine (d-Ala) and d-proline (d-Pro) were also detected in relatively high concentrations (>5%). The ratio was higher in male saliva than in female saliva. However, the difference in the ratio of d-Ala for one day was not very high and the effect of foods and beverage seemed to be negligible. Based on the results using l-Ala-d3, the d-Ala in saliva seemed to be produced due to the racemization with some enzymes such as racemase. The racemization reaction was reversible, i.e., d-Ala-d3 was also racemized to l-Ala-d3 in saliva. Thus, care should be taken during the analysis of dl-amino acids in saliva. The present method using DMT-(S)-Pro-OSu may be applicable for the determination of chiral amine metabolomics, because the resulting derivatives produce the same product ions without relation to the compounds and show highly sensitive detection in the SRM mode of MS/MS. Consequently, DMT-(S)-Pro-OSu seems to be a useful chiral derivatization reagent for the determination of amines and amino acids in biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号