首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Artemisinin is an antimalarial drug containing an internal endoperoxide linkage in its structure. A simple, selective and sensitive high-performance liquid chromatography (HPLC)-peroxyoxalate chemiluminescence (PO-CL) method for the determination of artemisinin was developed. This method is based on the fact that endoperoxide in artemisinin structure can be converted to hydrogen peroxide (H(2)O(2)) under ultraviolet (UV) irradiation and the generated hydrogen peroxide can be measured using PO-CL detection. The HPLC-PO-CL system was optimized on a mobile phase, post column chemiluminescence reagent, UV source and irradiation time. In addition, the system was combined with simple liquid-liquid extraction using n-hexane that allowed selective and sensitive determination of artemisinin in serum. The limit of detection using 0.5 mL of blood was 0.062 micromol/L (17.5 ng/mL) at a signal-to-noise ratio of 3. Calibration curve obtained for artemisinin in human serum 4-80 micromol/L (1.1-22.6 microg/mL) showed a good linearity (r = 0.999).  相似文献   

2.
A sensitive and highly selective high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K homologues including phylloquinone (PK), menaquinone-4 (MK-4) and menaquinone-7 (MK-7) in human plasma using post-column peroxyoxalate chemiluminescence (PO-CL) detection following on-line ultraviolet (UV) irradiation. The method was based on ultraviolet irradiation (254 nm, 15 W) of vitamin K to produce hydrogen peroxide and a fluorescent product at the same time, which can be determined with PO-CL detection. The separation of vitamin K by HPLC was accomplished isocratically on an ODS column within 35 min. The method involves the use of 2-methyl-3-pentadecyl-1,4-naphthoquinone as an internal standard. The detection limits (signal-to-noise ratio = 3) were 32, 38 and 85 fmol for PK, MK-4 and MK-7, respectively. The recoveries of PK, MK-4 and MK-7 were greater than 82% and the inter- and intra-assay R.S.D. values were 1.9-5.4%. The sensitivity and selectivity of this method were sufficient for clinical and nutritional applications.  相似文献   

3.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

4.
A combination of the electrophoretically mediated microanalysis methodology with a partial filling technique was applied for the inhibition study of bovine liver rhodanese by 2-oxoglutarate. In this set-up, part of the capillary is filled with the best buffer for the enzymatic reaction, while the rest of the capillary is filled with the optimal background electrolyte for separation of substrates and products. The estimated value of KI for 2-oxoglutarate was 3.62·10−4±1.43·10−4 M with respect to cyanide and 1.40·10−3±1.60·10−4 M with respect to thiosulfate. In addition, the type of inhibition was also evaluated. The findings of 2-oxoglutarate as the competitive inhibitor with respect to cyanide and as the uncompetitive inhibitor with respect to thiosulfate are in accordance with previous literature data.  相似文献   

5.
Summary A new sensitive HPLC-UV method has been developed and validated for the determination of amboroxol in dog plasma enabling the investigation of a newly developed 75 mg ambroxol-containing retard capsule of EGIS Pharmaceuticals Ltd., Budapest, Hungary. A gradient method was used for removing the longer retained plasma components of no interest. The separation was performed on a BDS Hypersil C18 (5 μm, 250×2.1 mm) analytical column, supplied with a 10 mm guard column containing the same packing material. The detection was performed at 210 nm. The calibration curve was linear in the range 25–2000 ng·mL−1. Nerisopam (EGIS-6775) was used as internal standard. Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

6.
Yonghua Sun  Zhijun Xi  Zuolong Shi 《Talanta》2009,79(3):676-1696
A simple and sensitive liquid chromatographic method coupled with electrogenerated chemiluminescence (ECL) was described for the separation and quantification of naproxen in human urine. The method was based on the ECL of naproxen in basic NaNO3 solution with a dual-electrode system. Factors affected the ECL emission were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of naproxen in the range of 4.0 × 10−8 g mL−1 to 2.0 × 10−6 g mL−1 and the detection limit was 1.6 × 10−8 g mL−1 (S/N = 3). Application of the method to the analyses of naproxen in human urine proved feasible.  相似文献   

7.
An isocratic high-performance liquid chromatographic method for determination of triptolide and triptonide in human plasma is described. Plasma samples were extracted with OasisHLB solid-phase extraction (SPE) cartridges. After pretreatment, they were separated on a SymmetryShieldRP(18) column with a mobile phase of acetonitrile-water (40:60,v/v) at 40 degrees C. The effluent was monitored at UV 217 nm. Linearity (0.010-1.0 mg/L) was good, and the lower limit of detection was 3 ng/mL for triptolide and 4.5 ng/mL for triptonide (S/N = 3). The relative standard deviations of intra- and inter-day assay were less than 15% and the recoveries were better than 80%. The developed method was applied to the determination of triptolide and triptonide concentration in a patient's plasma after taking the medicament containing Tripterygium wilfordii Hook. F.  相似文献   

8.
A simple, specific and sensitive HPLC method with UV detection was developed and validated for the determination of tectoridin in rat plasma for the first time. Chromatographic separation was performed on a WelchromTM C18 column (150 × 4.6 mm, i.d., 5 µm) at a flow rate of 1.0 mL min?1, using a mixture of methanol–2% HAc aqueous solution (31:69, v/v) as the mobile phase with UV detection at 266 nm. The calibration curves for tectoridin were linear over the concentration range of 1.10–274.40 µg mL?1 in rat plasma. The intra‐ and inter‐day accuracies (RE) were within ?3.23% and 4.11%. The intra‐ and inter‐day precisions (RSD) were not more than 2.74 and 4.72%, respectively. The present method was successfully applied to the pharmacokinetic studies of tectoridin in rats after intravenous administration of three different doses. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Ferruginol, a diterpene phenol, has recently received attention for its extensive pharmacological properties, including anti‐tumor, antibacterial, cardio‐protective and gastroprotective effects. In the present study, a high‐performance liquid chromatographic (HPLC) method was developed for determination of ferruginol in rat plasma and applied for the pharmacokinetics study. The HPLC assay was performed with a VP ODS‐C18 column. The mobile phaseconsisted of methanol and 1% acetic acid solution (90:10, v/v). The flow rate was 1.0 mL/min, and the wavelength was set at 270 nm. This method was linear over the studied range of 0.1–10.0 µg/mL for ferruginol. The correlation coefficient was 0.9998. The intra‐day and inter‐day precisions were better than 4 and 5%, respectively. The extraction recovery and accuracy were greater than 97 and 96%, respectively. The detection limit was 30 ng/mL. The mean maximum concentration of ferruginol in rat plasma was 3.14 µg/mL at 40 min after oral administration at a dose of 20 mg/kg. Ferruginol was absorbed quickly p.o. with t1/2ka = 14.86 min and had a high rate of elimination with t1/2 = 41.73 min. The pharmacokinetic process of ferruginol in rat was well described with a one‐compartment model. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma.  相似文献   

11.
Estradiol extracted with an ODS minicolumn from serum (500 μl) is derivatized with 5-dimethylamino-1-naphthalenesulfonyl (dansyl) chloride at room temperature for 80 min, purified on the ODS minicolumn, separated on silica gel columns (150 × 1.9 mm i.d. and 100 × 1.9 mm i.d.) with n-hexane/chloroform/ethanol (70:30:0.1) as eluent at 3 ml min?1 and detected by the chemiluminescence emission produced in a post-column reaction with bis-(2,4,6-trichlorophenyl) oxalate (8 mM in chloroform containing 100 mM triethylamine) and hydrogen peroxide (600 mM in methanol containing 6% (v/v) sodium acetate buffer at pH 4.0). The overall recovery of estradiol from serum is ca. 90% and the detection limit is ca. 50 pg.  相似文献   

12.
A rapid, simple and sensitive high-performance liquid chromatography method for the quantification of gambogic acid in dog plasma was developed and validated. After acidification with hydrochloric acid, dog plasma was extracted with ethyl acetate and determined by HPLC. The analysis was carried out on a reversed-phase C(18) analytical column. The mobile phase consisted of a mixture of methanol-0.05% phosphoric acid (94:6, v/v), and the column temperature was maintained at 35 degrees C. A constant mobile phase flow rate of 1.0 mL/min was employed throughout the analyses. The ultraviolet detector was set at 360 nm. Chromatographic separation was achieved in less than 10 min and the calibration curve was linear over a concentration range of 0.156-20 microg/mL. The intra-assay and inter-assay variability values were less than 10.0%. The accuracy ranged from 93.0 to 104.2%. The established method has been successfully applied to a pharmacokinetic study of gambogic acid in dogs.  相似文献   

13.
谢君  陈金  张福华 《色谱》1998,16(3):258-260
建立了用反相离子对HPLC测定动物血浆中恩诺沙星(ERFX)及其代谢产物环丙沙星(CPFX)浓度的方法。血浆中药物用二氯甲烷萃取,选用ODS柱,甲醇-四丁基氢氧化铵溶液为流动相,吡哌酸(PPA)作内标,检测波长272nm。方法简便、快速、灵敏、准确,适用于ERFX及其代谢物CPFX血药浓度的测定和药代动力学研究。并首次测定了黄牛血浆中的ERFX和CPFX。  相似文献   

14.
Quantification of paeonol, the principal bioactive component of Moutan cortex, in rat plasma following oral administration of Moutan cortex decoction was achieved by using a simple and sensitive high-performance liquid chromatographic method. The calibration curves for paeonol were linear in both the low (25-200 ng/mL) and the high concentration range (200-4000 ng/mL) with r(2) values of 0.9928 and 0.9993, respectively. The coefficients of variation of intra- and inter-day assays were 14.36, 6.52, 1.76, 1.25, 5.36, 3.30 and 1.42% and 12.70, 1.19, 2.98, 1.91, 1.75, 1.78 and 0.96% at concentrations of 25, 50, 100, 200, 500, 1000 and 2000 ng/mL, respectively. The recoveries of paeonol from rat plasma were found to be 101.9, 104.5, 105.4 and 101.2% for concentrations of 50, 500, 1000 and 2000 ng/mL, respectively. The paeonol plasma concentrations were fitted to two-compartment model with fi rst order absorption. The mean terminal half-lives (t(1/2)) of paeonol was 80.9 min.  相似文献   

15.
A simple, rapid and reliable high-performance liquid chromatographic method was developed and validated for the determination of pirfenidone and its major metabolites in rat plasma. Plasma proteins were precipitated with perchloric acid (10%, v/v) and the supernatant after centrifugation was determined using high-performance liquid chromatography. The analysis was carried out on a Lichrospher C(18) column (250 x 4.6 mm i.d., 5 microm). The mobile phase consisted of acetonitrile-water containing 0.2% acetic acid (23:77, v/v) at a flow-rate of 1 mL/min. The eluant was detected at 310 nm. The calibration curves were linear over a concentration range from 0.15 to 76.67 microg/mL. The accuracy (relative error) of the assay ranged from -2.6 to 7.9% and the precision (coefficient of variation) was less than 4.5%. The established method has been successfully applied to a pharmacokinetic study of pirfenidone following a single oral dose to rats.  相似文献   

16.
A simple and rapid high-performance liquid chromatographic (HPLC) method with ultraviolet detection has been developed and validated for the simultaneous determination of rifampicin and sulbactam in mouse plasma. Plasma samples were deproteinized with acetonitrile and separated by HPLC on a RP-18 (125 x 4 mm, 5 microm) column and gradient elution with potassium dihydrogen phosphate solution (pH 4.5; 50 mm) and acetonitrile at a flow-rate of 1.0 mL/min. Rifampicin and sulbactam were monitored at 230 nm and confirmed by means of their UV spectra using a diode-array detector. The method was linear at plasma levels from 1 to 100 microg/mL for rifampicin and from 5 to 200 microg/mL for sulbactam. The limits of quantification were 0.6 microg/mL for rifampicin and 4.2 microg/mL for sulbactam. The intra- and inter-day precisions of the method (RSD) were lower than 5% for both compounds. Average recoveries of rifampicin and sulbactam from mice plasma were 98.2 and 89.3%, respectively. The developed method was successfully applied to the determination of the pharmacokinetic profile of both compounds in mice.  相似文献   

17.
An HPLC–peroxyoxalate chemiluminescence (PO-CL) method for simultaneous determination of methylphenidate (MPH) and ritalinic acid (RA) was developed. The method was used to monitor MPH and RA after administration of MPH to rats. Deproteinized plasma spiked with 1-(3-trifluoromethylphenyl)piperazine (IS) was dried and labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F). The labeled sample was cleaned with two kinds of solid-phase extraction cartridge, and the DBD-labels were separated on an ODS column with gradient elution using a mixture of CH3CN and imidazole–HNO3 buffer. Separation of MPH and RA can be achieved within 33 min. The LODs of MPH and RA at a signal-to-noise ratio of 3 were 2.2 and 0.4 ng mL−1, respectively. Moreover, monitoring of MPH and RA after MPH administration (10 mg kg−1) to rat could be performed. The concentration of RA 480 min after administration was eight times higher than that of MPH. The proposed HPLC–PO-CL method was useful for determination of MPH and RA in rat plasma and was successfully used to monitor these substances after MPH administration.  相似文献   

18.
唐秀芳  甄乾娜  樊子勉  冯成亚  丁敏 《色谱》2012,30(6):613-617
建立了一种柱前衍生高效液相色谱-荧光检测法用于测定血浆中同型半胱氨酸(Hcy)。使用三(2-羧乙基)膦盐酸盐(TCEP)为还原剂,N-(1-芘)马来酰亚胺(NPM)为衍生剂进行样品预处理,Agilent Hypersil C-18柱(250 mm×4.0 mm, 5 μm)进行分离,流动相为15 mmol/L醋酸钠-乙腈-混合酸(300 mL水中含1 mL醋酸和1 mL磷酸)混合溶液,采用梯度洗脱,荧光检测激发波长为330 nm,发射波长为380 nm。Hcy的回收率为(102.08±4.94)%。线性范围为0.500~100 μmol/L,检出限(以信噪比为3计)为0.016 μmol/L。日内与日间相对标准偏差均小于5%。利用该方法对7例高血压患者和7例健康志愿者的血浆进行了测定,结果表明两组间的Hcy含量存在显著的差异(p<0.05)。本方法简单、快速、灵敏、特异,适用于血浆Hcy的临床定量测定。  相似文献   

19.
S Higashidate  K Imai 《The Analyst》1992,117(12):1863-1868
A highly sensitive method for determination of the plasma catecholamines, norepinephrine (NE), epinephrine (E) and dopamine (DA) is described. The method consists of the extraction of the catecholamines, using 3,4-dihydroxybenzylamine as internal standard, from plasma with alumina (5 mg), followed by a reversed-phase column separation, on-column fluorogenic derivatization with ethylenediamine (ED) and post-column peroxyoxalate chemiluminescent reaction detection utilizing bis[4-nitro-2-(3,6,9-trioxadecyl-oxycarbonyl)phenyl] oxalate (TDPO) and hydrogen peroxide. In order to optimize the reaction conditions for high-performance liquid chromatography to obtain highly sensitive detection, the effects of changing reagent compositions on the chemiluminescence yield were investigated. The following are the optimized conditions. Eluent, a mixture of 50 mmol l-1 potassium acetate (pH 3.20)-50 mmol l-1 potassium phosphate (pH 3.20)-acetonitrile (90.15 + 4.85 + 3 v/v/v) containing 1 mmol l-1 sodium hexanesulfonate (40 degrees C) and flow rate, 0.5 ml min-1. Fluorogenic reagent solution, 105 mmol l-1 ED and 175 mmol l-1 imidazole in acetonitrile-ethanol (90 + 10 v/v) and flow rate, 0.25 ml min-1. Reaction coil (15 m x 0.5 mm i.d.) heated at 80 degrees C. Chemiluminogenic reagent solution, 0.25 mmol l-1 TDPO, 150 mmol l-1 hydrogen peroxide and 110 mmol l-1 trifluoroacetic acid in dioxane-ethyl acetate (50:50 v/v) and flow rate, 1.4 ml min-1. The detection limits for all the catecholamines were 1 fmol (signal-to-noise ratio at 2). The standard deviations of the method for the determination of NE, E and DA added to rat plasma (2.5 nM) were 3, 3 and 4%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Summary A new sensitive HPLC-FLD method has been developed and validated for the determination of cisapride in human plasma for a bioequivalence study. A gradient method was used to remove late-eluting plasma components of no interest. The separation was performed on a Li-ChroCART 250-4 Purospher RP-18 (5 μm particle) analytical column fitted with a LiChroCART 4-4 Purospher RP-18 endcapped (5 μm particle) guard column. The excitation and emission wavelengths were 295 and 350 nm during fluorescence detection. The calibration plot was linear in the range of 5–200 ng mL−1. A demethoxy analogue of cisapride was used as internal standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号