首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of zafirlukast (ZFK) with 500 microL human plasma using valdecoxib as an internal standard (IS). The API-4,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of ZFK and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with 10 mm ammonium acetate (pH 6.4):acetonitrile (20:80, v/v) on a Hypersil BDS C(18) column. The total chromatographic run time was 2.0 min and the elution of ZFK and IS occurred at approximately 1.11 and 1.58 min, respectively. The MS/MS ion transitions monitored were 574.2 --> 462.1 for ZFK and 313.3 --> 118.1 for IS. The method was proved to be accurate and precise at a linearity range of 0.15-600 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 0.15 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 20 mg ZFK tablet.  相似文献   

2.
A rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and fully validated for simultaneous quantification of donepezil and its active metabolite, 6‐o‐desmethyl donepezil in human plasma. Analytes and the internal standard were extracted from human plasma by liquid–liquid extraction technique using a 30:70 v/v mixture of ethyl acetate and n‐hexane. The reconstituted samples were chromatographed on a C18 column by using a 70:30 v/v mixture of acetonitrile and ammonium formate (5 mm , pH 5.0) as the mobile phase at a flow rate of 0.6 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.09–24.2 ng/mL for donepezil and 0.03–8.13 ng/mL for 6‐o‐desmethyl donepezil. The results of the intra‐day and inter‐day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied for the estimation of the drug in real time plasma samples for pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
A bioanalytical method was developed and validated to estimate donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil simultaneously in human plasma using galantamine as an internal standard (IS). The chromatographic separation was achieved on a reverse‐phase XTerra RP (150 × 4.6 mm, 5 µm) column without affecting recovery (mean recovery > 60% with CV < 10%) for all analytes. ESI‐MS/MS multiple reaction monitoring in positive polarity was used to detect mass pairs for donepezil (m/z 380.3 → 91.3), 6‐desmethyl donepezil (m/z 366.4 → 91.3), 5‐desmethyl donepezil (m/z 366.4 → 91.3) and galantamine m/z (288.1 → 213.0). The linearity was established over a dynamic range of 0.339–51.870, 0.100–15.380 and 0.103–15.763 ng/mL for donepezil, 6‐desmethyl donepezil and 5‐desmethyl donepezil, respectively. The current method shows that minimal conversion of labile metabolites to parent donepezil in plasma as stability was successfully achieved for 211 days at ?15 °C storage temperature. The method was successfully applied to a clinical study after administration of 10 mg donepezil tablets to healthy male Indian volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
《Analytical letters》2012,45(4):737-746
Abstract

A rapid, sensitive, and selective high‐performance liquid chromatography‐tandem mass spectrometric method (HPLC‐MS‐MS) for the determination of coumatetralyl in human serum using warfarin as an internal standard has been developed and validated. Coumatetralyl and the internal standard were extracted from the human serum samples by liquid‐liquid extraction with ethyl acetate, followed by separation on a XDB C18 reversed‐phase column (150 mm×2.1 mm i.d., 5 µm) using a mobile phase consisting of acetic acid‐ammonium acetate (5 mmol/L, pH=4.5)/methanol (20:80, v/v) at a constant flow rate of 0.40 mL/min. Coumatetralyl and the internal standard were ionized by negative ion pneumatically assisted electrospray and detected in the multiple‐reaction monitoring mode using precursor→product ion combinations at m/z 291→247 and 307→161, respectively. The calibration curve was linear (r2=0.9945) in the concentration range of 0.5~100.0 ng/mL, with a lower limit of quantification of 0.5 ng/mL in human serum. Intra‐ and inter‐day relative standard deviations were less than 6.3 and 11.0%, respectively. The mean extraction recovery was 87.9% for coumatetralyl and 90.1% for the internal standard. This method is found to be able to determine trace coumatetralyl in human serum and can be used for the diagnosis of poisoned human beings.  相似文献   

5.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 microL hamster/dog plasma using DRL-16126 as an internal standard (IS). The API-4000 Q Trap LC-MS/MS was operated under multiple-reaction monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of TTB and IS from plasma with acetonitrile, which yielded consistent recoveries of 65.73 and 94.01% for TTB and 79.68 and 90.70% for IS in hamster and dog plasma, respectively. The total chromatographic run time was 3.0 min and the elution of TTB and IS occurred at approximately 2.25 and 2.20 min, respectively. The resolution of peaks was achieved with 0.01 m ammonium acetate:acetonitrile (15:85, v/v) at a flow rate of 0.40 mL/min on an Inertsil ODS-3 column. The method was proved to be accurate and precise at linearity range of 1.00-200 ng/mL with a correlation coefficient (r) of > or = 0.993. The method was rugged with 1.00 ng/mL as the lower limit of quantitation. TTB was stable in the battery of stability studies. The application of the assay to preclinical pharmacokinetic studies confirmed the utility of the assay to derive hamster/dog pharmacokinetic parameters.  相似文献   

6.
A hydrophilic interaction chromatography‐tandem mass spectrometric method (HILIC/MS/MS) for the determination of irbesartan in human plasma was developed. Irbesartan and losartan (internal standard) were extracted from human plasma with ethyl acetate at acidic pH. The analytes were analyzed on a Luna HILIC column with the mobile phase of ACN–ammonium formate (50 mM, pH 6.5) (96:4, v/v) and detected by ESI MS/MS in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.9981) over the concentration range of 10–2500 ng/mL and the lower LOQ was 10 ng/mL using 100 μL of plasma sample. The CV and relative error for intra‐ and interassay at four QC levels were 2.9 to 8.1% and –2.7 to 2.3%, respectively. There were less absolute and relative matrix effects for irbesartan and losartan. The present method was successfully applied to the pharmacokinetic study of irbesartan after oral dose of irbesartan (150 mg tablet) to male healthy volunteers.  相似文献   

7.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry (LC-MS/MS) quantitative detection method, using cefalexin as internal standard, was developed for the analysis of faropenem in human plasma and urine. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a C18 reversed-phase column with 0.1% formic acid-methanol (45:55, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves with good linearities (r=0.9991 for plasma sample and r=0.9993 for urine sample) were obtained in the range 5-4000 ng/mL for faropenem. The limit of detection was 5 ng/mL. Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of faropenem in humans, and to our knowledge, it is the first time the pharmacokinetic of faropenem has been elucidated in vivo using LC-MS/MS.  相似文献   

8.
A sensitive and high‐throughput LC‐MS/MS method has been developed and validated for the combined determination of esomeprazole and naproxen in human plasma with ibuprofen as internal standard. Solid‐phase extraction was used to extract both analytes and internal standard from human plasma. Chromatographic separation was achieved in 4.0 min on XBridge C18 column using acetonitrile–25 mM ammonium formate (70:30, v/v) as mobile phase. Mass detection was achieved by ESI/MS/MS in negative ion mode, monitoring at m/z 344.19 → 194.12, 229.12 → 169.05 and 205.13 → 161.07 for esomeprazole, naproxen and IS, respectively. The calibration curves were linear from 3.00 to 700.02 ng/mL for esomeprazole and 0.50 to 150.08 ng/mL for naproxen. The intra‐ and inter‐batch precision and accuracy across four quality control levels met established criteria of US Food and Drug Administration guidelines. The assay is suitable for measuring accurate esomeprazole and naproxen plasma concentrations in human bioequivalence study following combined administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
A simple and rapid liquid chromatography with tandem mass spectrometry method has been developed and validated for the determination of rabeprazole and its two active metabolites, rabeprazole thioether and desmethyl rabeprazole thioether, in human urine using donepezil as the internal standard. The sample preparation procedure involved a simple dilution of urine sample with methanol (1:3, v/v). The chromatographic separation was achieved on a Hedera ODS‐2 C18 column using a mixture of methanol/10 mmol/L ammonium acetate solution (containing 0.05% formic acid; 55:45, v/v) as the mobile phase. The method was validated over the concentration ranges of 0.15–100 ng/mL for rabeprazole, 0.30–400 ng/mL for rabeprazole thioether, and 0.05–100 ng/mL for desmethyl rabeprazole thioether. The established method was highly sensitive with a lower limit of quantification of 0.15 ng/mL for rabeprazole, 0.30 ng/mL for rabeprazole thioether, and 0.05 ng/mL for desmethyl rabeprazole thioether. The intra‐ and interbatch precision was <4.5% for the low, medium, and high quality control samples of all the analytes. The recovery of the analytes was in the range 95.4–99.0%. The method was successfully applied to a urinary excretion profiles after intravenous infusion administration of 20 mg rabeprazole sodium in healthy volunteers.  相似文献   

10.
A rapid, simple, selective and sensitive LC‐MS/MS method was developed for the determination of curculigoside in rat plasma. The analytical procedure involves extraction of curculigoside and syringin (internal standard, IS) from rat plasma with a one‐step extraction method by protein precipitation. The chromatographic resolution was performed on an Agilent XDB‐C18 column (4.6 × 50 mm, 5 µm) using an isocratic mobile phase of methanol with 0.1% formic acid and H2O with 0.1% formic acid (45:55, v/v) at a flow rate of 0.35 mL/min with a total run time of 2.0 min. The assay was achieved under the multiple‐reaction monitoring mode using positive electrospray ionization. Method validation was performed according to US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over 4.00–4000 ng/mL (R = 0.9984) for curculigoside with a lower limit of quantification of 4.00 ng/mL in rat plasma. The intra‐ and inter‐day precisions and accuracies were 3.5–4.6 and 0.7–9.1%, in rat plasma, respectively. The validated LC‐MS/MS method was successfully applied to a pharmacokinetic study of curculigoside in rats after a single intravenous and oral administration of 3.2 and 32 mg/kg. The absolute bioavailability of curculigoside after oral administration was 1.27%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
《Analytical letters》2012,45(7):1381-1391
Abstract

A rapid, sensitive, and specific liquid chromatography‐electrospray ionization mass spectrometric (LC‐ESI‐MS) method has been developed for quantification of gliclazide in human plasma. The analyte and tolbutamide (internal standard, I.S.) were extracted from plasma samples with n‐hexane–dichloromethane (1:1, v/v) and analyzed on a C18 column. The chromatographic separation was achieved within 4.0 min by using methanol–0.5% formic acid (80:20, v/v) as mobile phase and the flow rate was 1.0 mL/min. Ion signals m/z 324.0 and 271.0 for gliclazide and internal standard were measured in the positive mode, respectively. The method was linear within the range of 2.5–2000 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra‐ and inter‐day precisions were lower than 2.8% in terms of relative standard deviation (RSD). The inter‐day relative error (RE) as determined from quality control samples (QCs) ranged from ?1.93% to 1.85%. This validated method was successfully applied for the evaluation of pharmacokinetic profiles of gliclazide modified‐release tablets in 20 healthy volunteers.  相似文献   

12.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of doxofylline (DFL) with 300 microL human serum using imipramine as the internal standard (IS). The API-3,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved direct precipitation of DFL and IS from human serum with acetonitrile. The resolution of peaks was achieved with formic acid (pH 2.5): acetonitrile (10:90, v/v) on an Amazon C(18) column. The total chromatographic run time was 3.0 min and the elution of DFL and IS occurred at approximately 1.46 and 2.15 min, respectively. The MS/MS ion transitions monitored were 267.5 --> 181.1 for DFL and 281.1 --> 86.2 for IS. The method was proved to be accurate and precise at linearity range of 1.00-5,000 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 1.00 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of DFL tablet.  相似文献   

13.
A selective and sensitive HPLC–MS/MS method was developed for the simultaneous determination of cucurbitacin IIa (cuIIa) and cucurbitacin IIb (cuIIb), the major bioactive cucurbitacins of Hemsleya amabilis, in rat plasma using euphadienol as internal standard (IS). After liquid–liquid extraction with dichloromethane, separation was achieved on a Syncronis HPLC C18 column (150 mm × 4.6 mm, 5 μm) using an isocratic mobile phase system consisting of acetonitrile–water (85:15, v/v) at a flow rate of 0.6 mL/min with a split ratio of 1:2. Detection was performed on a TSQ Quantum Ultra mass spectrometer equipped with an positive‐ion electrospray ionization source. The lower limits of quantification (LLOQs) were 0.25 and 0.15 ng/mL for cuIIa and cuIIb, respectively. The intra‐ and inter‐day precision was <11.5% for the LLOQs and each quality control level of the analytes, and accuracy was between ?9.1 and 7.6%. The extraction recoveries of the analytes and IS from rat plasma were all >87.1%. The method was fully validated and applied to compare the pharmacokinetic profiles of the two cucurbitacins in rat plasma after oral administration of H. amabilis extract between normal and indomethacin‐induced rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
A bioanalytical method for the quantification of rosiglitazone in rat plasma and tissues (adipose tissue, heart, brain, bone, and kidney) using LC–MS/MS was developed and validated. Chromatographic separation was achieved on a Gemini C18 column (50 × 4.6 mm, 3 μm) using a mobile phase consisting of 10 mM ammonium formate (pH 4.0) and acetonitrile (10:90, v/v) at a flow rate of 0.8 mL/min and injection volume of 10 μL (internal standard: pioglitazone). LC–MS detection was performed with multiple reaction monitoring mode using target ions at m/z → 358.0 and m/z → 357.67 for rosiglitazone and pioglitazone (internal standard), respectively. The calibration curve showed a good correlation coefficient (r2) over the concentration range of 1–10,000 ng/mL. The mean percentage recoveries of rosiglitazone were found to be over the range of 92.54–96.64%, with detection and lower quantification limit of 0.6 and 1.0 ng/mL, respectively. The developed method was validated per U.S. Food and Drug Administration guidelines and successfully utilized to measure rosiglitazone in plasma and tissue samples. Further, the developed method can be utilized for validating specific organ-targeting delivery systems of rosiglitazone in addition to conventional dosage forms.  相似文献   

15.
A simple, rapid and sensitive liquid chromatography/positive ion electro‐spray tandem mass spectrometry method (LC‐MS/MS) was developed and validated for the quantification of fexofenadine with 100 μL human plasma employing glipizide as internal standard (IS). Protein precipitation was used in the sample preparation procedure. Chromatographic separation was achieved on a reversed‐phase C18 column (5 μm, 100 × 2.1 mm) with methanol : buffer (containing 10 mmol/L ammonium acetate and 0.1% formic acid; 70 : 30, v/v) as mobile phase. The total chromatographic runtime was approximately 3.0 min with retention time for fexofenadine and IS at approximately 1.9 and 2.1 min, respectively. Detection of fexofenadine and IS was achieved by LC‐MS/MS in positive ion mode using 502.1 → 466.2 and 446.0 → 321.1 transitions, respectively. The method was proved to be accurate and precise at linearity range of 1–600 ng/mL with a correlation coefficient (r) of ≥0.9976. The validated method was applied to a pharmacokinetic study in human volunteers following oral administration of 60 or 120 mg fexofenadine formulations, successfully. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A highly sensitive, rapid assay method was developed and validated for the estimation of lorglumide in mouse plasma using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in positive‐ion mode. The assay procedure involves extraction of lorglumide and phenacetin (internal standard, IS) from mouse plasma with simple protein precipitation. Chromatographic separation was achieved using an isocratic mobile (0.2% formic acid solution–acetonitrile, 20:80, v/v) at a flow‐rate of 0.5 mL/min on an Atlantis dC18 column maintained at 40 °C with a total run time of 4.0 min. The MS/MS ion transitions monitored were 459.2 → 158.4 for lorglumide and 180.1 → 110.1 for IS. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.42 ng/mL and the linearity range extended from 0.42 to 500 ng/mL. The intra‐ and inter‐day precisions were in the ranges of 1.47–10.9 and 3.56–7.53, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A rapid and highly sensitive assay method has been developed and validated for the estimation of galantamine (GLM) in rat plasma using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of GLM and phenacetin (internal standard, IS) from rat plasma using acetonitrile. Chromatographic separation was achieved with 0.2% formic acid:acetonitrile (50:50, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 2.5 min. The MS/MS ion transitions monitored were 288.10 → 213.10 for GLM and 180.10 → 110.10 for IS. Method validation was performed as per United States Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.12 ng/mL and linearity was observed from 0.12 to 525 ng/mL. The intra‐ and inter‐day precision were in the ranges of 4.73–11.7 and 5.83–8.64%, respectively. This novel method has been applied to a pharmacokinetic study in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid and highly sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method for determination of dapiprazole on rat dried blood spots and urine was developed and validated. The chromatographic separation was achieved on a reverse‐phase C18 column (250 × 4.6 mm i.d., 5 µm), using 20 mm ammonium acetate (pH adjusted to 4.0 with acetic acid) and acetonitrile (80:20, v/v) as a mobile phase at 25 °C. LC‐MS detection was performed with selective ion monitoring using target ions at m/z 326 and m/z 306 for dapiprazole and mepiprazole used as internal standard, respectively. The calibration curve showed a good linearity in the concentration range of 1–3000 ng/mL. The effect of hematocrit on extraction of dapiprazole from DBS was evaluated. The mean recoveries of dapiprazole from DBS and urine were 93.88 and 90.29% respectively. The intra‐ and inter‐day precisions were <4.19% in DBS as well as urine. The limits of detection and quantification were 0.30 and 1.10 ng/mL in DBS and 0.45 and 1.50 ng/mL in urine samples, respectively. The method was validated as per US Food and Drug Administration guidelines and successfully applied to a pharmacokinetic study of dapiprazole in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A rapid and sensitive liquid chromatography–tandem mass spectrometric method (LC‐MS/MS) for the determination of bromotetrandrine in rat plasma has been developed and applied to pharmacokinetic study in Sprague–Dawley (SD) rats after a single oral administration. Sample preparation involves a liquid–liquid extraction with n‐hexane–dichlormethane (65:35, containing 1% 2‐propanol isopropyl alcohol, v/v). Bromotetrandrine and brodimoprim (internal standard, IS) were well separated by LC with a Dikma C18 column using methanol–ammonium formate aqueous solution (20 mm ) containing 0.5% formic acid (60:40, v/v) as mobile phase. Detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 703.0 → 461.0 and m/z 339.0 → 281.0 for bromotetrandrine and IS, respectively. The present method exhibited good linearity over the concentration range of 20–5000 ng/mL for bromotetrandrine in rat plasma with a lower limit of quantification of 20 ng/mL. The intra‐ and inter‐day precisions were 2.8–7.5% and 3.2–8.1%, and the intra‐ and inter‐day accuracy ranged from ?4.8 to 8.2% and ?5.6 to 6.2%, respectively. The method was successfully applied to a pharmacokinetic study after a single oral administration to SD rats with bromotetrandrine of 50 mg/kg. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method has been developed and validated for the determination of asperosaponin VI in beagle dog plasma using glycyrrhizic acid as the internal standard (IS). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on a Hedera ODS‐2 column using mobile phase of methanol–10 mm ammonium acetate buffer solution containing 0.05% acetic acid (71:29, v/v) at a flow rate of 0.38 mL/min. Asperosaponin VI and the IS were eluted at 2.8 and 1.9 min, respectively, ionized in negative ion mode, and then detected by multiple reaction monitoring. The detection used the transitions of the deprotonated molecules at m/z 927.5 → 603.4 for asperosaponin VI and m/z 821.4 → 645.4 for glycyrrhizic acid (IS). The assay was linear over the concentration range of 0.15–700 ng/mL and was successfully applied to a pilot pharmacokinetic study in beagle dogs. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号