首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Potyrailo RA  Burns A  Surman C  Lee DJ  McGinniss E 《The Analyst》2012,137(12):2777-2781
We demonstrate roll-to-roll (R2R) fabrication of highly selective, battery-free radio frequency identification (RFID) sensors on a flexible polyethylene terephthalate (PET) polymeric substrate. Selectivity of our developed RFID sensors is provided by measurements of their resonance impedance spectra, followed by the multivariate analysis of spectral features, and correlation of these spectral features to the concentrations of vapors of interest. The multivariate analysis of spectral features also provides the ability for the rejection of ambient interferences. As a demonstration of our R2R fabrication process, we employed polyetherurethane (PEUT) as a "classic" sensing material, extruded this sensing material as 25, 75, and 125-μm thick films, and thermally laminated the films onto RFID inlays, rapidly producing approximately 5000 vapor sensors. We further tested these RFID vapor sensors for their response selectivity toward several model vapors such as toluene, acetone, and ethanol as well as water vapor as an abundant interferent. Our RFID sensing concept features 16-bit resolution provided by the sensor reader, granting a highly desired independence from costly proprietary RFID memory chips with a low-resolution analog input. Future steps are being planned for field-testing of these sensors in numerous conditions.  相似文献   

2.
Optical array‐based sensors are attractive candidates for the detection of various bio‐analytes due to their convenient fabrication and measurements. For array‐based sensors, multichannel arrays are more advantageous and used frequently in many electronic sensors. But most reported optically array based sensors are constructed on a single channel array. This difficulty is mainly instigated from the overlap in optical responses. In this report we have used nano‐graphene oxide (nGO) and suitable fluorophores as sensor elements to construct a multichannel sensor array for the detection of protein analytes. By using the optimized multichannel array we are able to detect different proteins and mixtures of proteins with 100 % classification accuracy at sub‐nanomolar concentration. This modified method expedites the sensing analysis as well as minimizes the use of both analyte and sensor elements in array‐based protein sensing. We have also used this system for the single channel array‐based sensing to compare the sensitivity and the efficacy of these two systems for other applications. This work demonstrated an intrinsic trade‐off associated with these two methods which may be necessary to balance for array‐based analyte detections.  相似文献   

3.
An investigation into suitable mathematical techniques which can be used to select sensor components for a gas sensor array is reported. Data from a tin dioxide Taguchi semiconductor sensor array were obtained individually for various organic solvents and analysed using multivariate techniques, including principal component analysis, cluster analysis and star symbol plots. It was shown that the array data produced a series of characteristic response patterns for the analytes. It was also found that analytes of similar chemical nature had similar response patterns, indicating a correlation between sensor interaction and the chemical functional groups of the analyte. The multivariate techniques used proved to be very useful in enabling a suitable selection of the components of the array to be made by identifying which of the components or sensors were acting independently.  相似文献   

4.
Spectroelectrochemical sensors combine electrochemistry, spectroscopy, and partitioning into a film to provide improved selectivity for the target analyte. The sensor usually consists of an optically transparent electrode (OTE) coated with a charge selective polymer film. The polymer film is chosen to pre‐concentrate analyte at the OTE surface to improve the sensitivity and provide selectivity against like charged interferences. OTEs such as Indium Tin Oxide (ITO) have been used extensively for spectroelectrochemical sensors, but little is known about the applicability of such sensors using other OTE materials, such as Boron Doped Diamond (BDD). One distinct advantage of BDD OTEs over ITO OTEs is their significant increase in sensitivity for organic compounds, such as 4‐aminophenol and hydroquinone. We have developed absorption and fluorescence‐based sensing methods with a BDD OTE coated with a sulfonated ionomer film, Nafion. This is demonstrated with tris(2,2′‐bipyridyl)ruthenium(II) ion [Ru(bpy)32+] using an attenuated total reflectance (ATR) flow cell setup for both absorption and fluorescence. With a Nafion coated BDD optically transparent thin layer electrode (OTTLE), we developed a fluorescence based sensor for a common polyaromatic hydrocarbon (PAH), 1‐hydroxypyrene (1‐pyOH), achieving a detection limit of 80 nM (17 ppb). This work manifests new sensing applications while broadening the use of spectroelectrochemistry, OTEs, and BDD as an electrode material.  相似文献   

5.
Micro- and nanoelectromechanical systems, including cantilevers and other small scale structures, have been studied for sensor applications. Accurate sensing of gaseous or aqueous environments, chemical vapors, and biomolecules have been demonstrated using a variety of these devices that undergo static deflections or shifts in resonant frequency upon analyte binding. In particular, biological detection of viruses, antigens, DNA, and other proteins is of great interest. While the majority of currently used detection schemes are reliant on biomarkers, such as fluorescent labels, time, effort, and chemical activity could be saved by developing an ultrasensitive method of label-free mass detection. Micro- and nanoscale sensors have been effectively applied as label-free detectors. In the following, we review the technologies and recent developments in the field of micro- and nanoelectromechanical sensors with particular emphasis on their application as biological sensors and recent work towards integrating these sensors in microfluidic systems.  相似文献   

6.
Not only are sensors a revolution in analysis; they themselves are also experiencing a revolution brought about by parallel developments in sensor fabrication techniques and materials, polymer chemistry, signal processing methodologies, the increased use of biomolecular processes as a means of analyte detection, and the coupling of sensors to other techniques such as flow injection analysis. Many of these developments have been incorporated into the present study, which we are undertaking in the development of our immunosensor technology. The system described here utilises screen-printed electrodes which are low-cost, disposable devices that are simple to fabricate. Incorporated into our sensor is the electroactive polymer, polyaniline, which brings about mediatorless redox coupling between the electrode and biomolecular components attached to the polymer surface. This system also utilises enzyme-labelled antibodies as the biomolecular recognition component for the analysis of the test analyte, biotin. The system has also been integrated into a flow injection system. This has led to the monitoring of real-time antibody-antigen interactions using electrochemical methods and foreshadows the development of single-step immunosensors.  相似文献   

7.
Modular aptameric sensors   总被引:7,自引:0,他引:7  
We report the first examples of modular aptameric sensors, which transduce recognition events into fluorescence changes through allosteric regulation of noncovalent interactions with a fluorophore. These sensors consist of: (a) a reporting domain, which signals the binding event of an analyte through binding to a fluorophore; (b) a recognition domain, which binds the analyte; and (c) a communication module, which serves as a conduit between recognition and signaling domains. We tested recognition regions specific for ATP, FMN, and theophylline in combinations with malachite green binding aptamer as a signaling domain. In each case, we were able to obtain a functional sensor capable of responding to an increase in analyte concentration with an increase in fluorescence. Similar constructs that consist only of natural RNA could be expressed in cells and used as sensors for intracellular imaging.  相似文献   

8.
A general approach is described for the de novo design and construction of aptamer-based electrochemical biosensors, for potentially any analyte of interest (ranging from small ligands to biological macromolecules). As a demonstration of the approach, we report the rapid development of a made-to-order electronic sensor for a newly reported early biomarker for lung cancer (CTAP III/NAP2). The steps include the in vitro selection and characterization of DNA aptamer sequences, design and biochemical testing of wholly DNA sensor constructs, and translation to a functional electrode-bound sensor format. The working principle of this distinct class of electronic biosensors is the enhancement of DNA-mediated charge transport in response to analyte binding. We first verify such analyte-responsive charge transport switching in solution, using biochemical methods; successful sensor variants were then immobilized on gold electrodes. We show that using these sensor-modified electrodes, CTAP III/NAP2 can be detected with both high specificity and sensitivity (K(d) ~1 nM) through a direct electrochemical reading. To investigate the underlying basis of analyte binding-induced conductivity switching, we carried out F?rster Resonance Energy Transfer (FRET) experiments. The FRET data establish that analyte binding-induced conductivity switching in these sensors results from very subtle structural/conformational changes, rather than large scale, global folding events. The implications of this finding are discussed with respect to possible charge transport switching mechanisms in electrode-bound sensors. Overall, the approach we describe here represents a unique design principle for aptamer-based electrochemical sensors; its application should enable rapid, on-demand access to a class of portable biosensors that offer robust, inexpensive, and operationally simplified alternatives to conventional antibody-based immunoassays.  相似文献   

9.
Linear sensor arrays made from small molecule/carbon black composite chemiresistors placed in a low-headspace volume chamber, with vapor delivered at low flow rates, allowed for the extraction of new chemical information that significantly increased the ability of the sensor arrays to identify vapor mixture components and to quantify their concentrations. Each sensor sorbed vapors from the gas stream and, thereby, as in gas chromatography, separated species having high vapor pressures from species having low vapor pressures. Instead of producing only equilibrium-based sensor responses that were representative of the thermodynamic equilibrium partitioning of analyte between each sensor and the initial vapor phase, the sensor responses varied depending on the position of the sensor in the chamber and the time since the beginning of the analyte exposure. The concomitant spatiotemporal (ST) sensor array response therefore provided information that was a function of time, as well as of the position of the sensor in the chamber. The responses to pure analytes and to multicomponent analyte mixtures comprised of hexane, decane, ethyl acetate, chlorobenzene, ethanol, and/or butanol were recorded along each of the sensor arrays. Use of a non-negative least-squares (NNLS) method for analysis of the ST data enabled the correct identification and quantification of the composition of two-, three-, four-, and five-component mixtures from arrays using only four chemically different sorbent films. In contrast, when traditional time- and position-independent sensor response information was used, these same mixtures could not be identified or quantified robustly. The work has also demonstrated that, for ST data, NNLS yielded significantly better results than analyses using extended disjoint principal components modeling. The ability to correctly identify and quantify constituent components of vapor mixtures through the use of such ST information significantly expands the capabilities of such broadly cross-reactive arrays of sensors.  相似文献   

10.
Novel chemical sensors based on a time-dependent nonlinear response are reviewed. The strategy is to artificially mimic information transduction in living organisms. In taste and olfaction, information of chemical structure and concentration is transformed into nervous impulses in the nervous cell, i.e., time-dependent multi-dimensional information. Because the excitation and pulse generation in the nervous cell are typically nonlinear phenomena, it may be worthwhile to utilize the nonlinearity as the multi-dimensional information for molecular recognition. The principle of a "nonlinear" sensor is that a sinusoidal modulation is applied to a system, and the output signal is analyzed. The output signal of the sensor is characteristically deformed from the sinusoidal input depending on the chemical structure and concentration of the chemical stimuli. The characteristic nonlinear responses to chemical stimuli are discussed in relation to the kinetics of chemical compounds on the sensor surface. As a practical application, we introduced electrochemical sensors based on the differential capacitance, semiconductor gas sensors under the application of sinusoidal temperature or diffusion change, and a chemical sensor based on the spatio-temporal information. We demonstrated that mutli-dimensional information based on nonlinearity can provide quite useful information for the analysis of chemical species, even in the presence of another analyte or an interference with a single detector.  相似文献   

11.
To detect biomarkers from human exhalation, air flow dynamics on the nanoparticle surface were explored by a surface‐enhanced Raman scattering (SERS) sensor. A hollow Co‐Ni layered double hydroxide (LDH) nanocage on Ag nanowires (Ag@LDH) was prepared. Ag nanowires provided amplified Raman signals for trace determination; hollow LDH nanocages served as the gaseous confinement cavity to improve capture and adsorption of gaseous analytes. The Raman intensity and logarithmic analyte concentration exhibit an approximately linear relationship; the detection limit of SERS sensors for aldehyde is 1.9×10?9 v/v (1.9 ppb). Various aldehydes in mixed mimetic gas are distinguished by Raman spectra statistical analysis assisted by multivariate methods, including principal component analysis and hierarchical cluster analysis. The information was recorded in a barcode, which can be used for the design and development of a desktop SERS sensor analysis system for large‐scale lung cancer detection.  相似文献   

12.
DNA conformational switches as sensitive electronic sensors of analytes   总被引:4,自引:0,他引:4  
The electrical conductivity of DNA is dependent on its conformational state. We demonstrate here that such a dependence may be harnessed for the electronic sensing of external analytes, for instance, adenosine. Such a DNA sensor incorporates an analyte "receptor", whose altered conformation in the presence of bound analyte switches the conformation, and hence, the conductive path between two DNA double-helical stems. Two distinct designs for such sensors are described here, that permit significant electrical conduction through a "detector" double-helical stem only in the presence of the bound analyte. In the first design, current flows through the analyte receptor itself, whereas in the second, current flows in a path adjacent to the receptor. The former design may be especially suitable for certain categories of analytes, including heterocycle-containing compounds such as adenosine, whereas the latter design should be generally applicable to the detection of any molecular analyte, large or small. Since analyte detection in these DNA sensors is electronic, the potential exists for their application in rapid and automated chip-based detection of small molecules as well as of proteins and other macromolecules.  相似文献   

13.
Adsorption dynamics and their influence on signal transduction for carbon nanotube-based chemical sensors are explored using continuum site balance equations and a mass action model. These sensors are shown to possess both reversible and irreversible binding sites that can be modeled independently. For the case of irreversible adsorption, it is shown that the characteristic response time scales inversely with analyte concentration. It is inappropriate to report a detection limit for this type of sensor since any nonzero analyte concentration can be detected in theory but at a cost of increasing transduction time with decreasing concentration. The response curve should examine the initial rate of signal change as a function of analyte concentration. Conversely, a reversible sensor has a predefined detection limit, independent of the detector geometry with a characteristic time scaling that becomes constant in the zero analyte concentration limit. A simple analytical test is presented to distinguish between these two mechanisms from the transient response of a nanotube sensor array. Two systems appearing in the literature are shown to have an irreversible component, and regressed surface rate constants for this component are similar across different sensor geometries and analytes.  相似文献   

14.
Magnetic nanoparticles (NPs) have been used to obtain NMR-based sensors for analytes ranging from small molecules to viruses by the conjugation of biomolecules (antibodies, proteins, oligonucleotides) to the surface of NPs. In the presence of an analyte, the NPs form clusters that alter the relaxation time of the surrounding water protons. Here, we show that an organic molecule that binds calcium ions of nonbiological origin, rather than a biomolecule, can be employed to modify the surface of a magnetic NP. When calcium ions are added, they induce NP clustering, providing an NMR-based sensor for these ions. Our work suggests that the many chemistries of nonbiological origin, such as those employed for ion-selective electrodes, can be adapted to obtain NMR-based sensors for ions.  相似文献   

15.
Array‐based sensor “chemical nose/tongue” platforms are inspired by the mammalian olfactory system. Multiple sensor elements in these devices selectively interact with target analytes, producing a distinct pattern of response and enabling analyte identification. This approach offers unique opportunities relative to “traditional” highly specific sensor elements such as antibodies. Array‐based sensors excel at distinguishing small changes in complex mixtures, and this capability is being leveraged for chemical biology studies and clinical pathology, enabled by a diverse toolkit of new molecular, bioconjugate and nanomaterial technologies. Innovation in the design and analysis of arrays provides a robust set of tools for advancing biomedical goals, including precision medicine.  相似文献   

16.
Qi X  Crooke E  Ross A  Bastow TP  Stalvies C 《The Analyst》2011,136(18):3731-3738
This paper presents a system and method developed to identify a source oil's characteristic properties by testing the oil's dissolved components in water. Through close examination of the oil dissolution process in water, we hypothesise that when oil is in contact with water, the resulting oil-water extract, a complex hydrocarbon mixture, carries the signature property information of the parent oil. If the dominating differences in compositions between such extracts of different oils can be identified, this information could guide the selection of various sensors, capable of capturing such chemical variations. When used as an array, such a sensor system can be used to determine parent oil information from the oil-water extract. To test this hypothesis, 22 oils' water extracts were prepared and selected dominant hydrocarbons analyzed with Gas Chromatography-Mass Spectrometry (GC-MS); the subsequent Principal Component Analysis (PCA) indicates that the major difference between the extract solutions is the relative concentration between the volatile mono-aromatics and fluorescent polyaromatics. An integrated sensor array system that is composed of 3 volatile hydrocarbon sensors and 2 polyaromatic hydrocarbon sensors was built accordingly to capture the major and subtle differences of these extracts. It was tested by exposure to a total of 110 water extract solutions diluted from the 22 extracts. The sensor response data collected from the testing were processed with two multivariate analysis tools to reveal information retained in the response patterns of the arrayed sensors: by conducting PCA, we were able to demonstrate the ability to qualitatively identify and distinguish different oil samples from their sensor array response patterns. When a supervised PCA, Linear Discriminate Analysis (LDA), was applied, even quantitative classification can be achieved: the multivariate model generated from the LDA achieved 89.7% of successful classification of the type of the oil samples. By grouping the samples based on the level of viscosity and density we were able to reveal the correlation between the oil extracts' sensor array responses and their original oils' feature properties. The equipment and method developed in this study have promising potential to be readily applied in field studies and marine surveys for oil exploration or oil spill monitoring.  相似文献   

17.
This focused review presents various approaches or formats in which liquid crystals (LCs) have been used as stimuli-responsive sensors. In these sensors, the LC molecules adopt some well-defined arrangement based on the sensor composition and the chemistry of the system. The sensor usually consists of a molecule or functionality in the system that engages in some form of specific interaction with the analyte of interest. The presence of analyte brings about the specific interaction, which then triggers an orientational transition of the LC molecules, which is optically discernible via a polarized optical image that shows up as dark or bright, depending on the orientation of the LC molecules in the system (usually a homeotropic or planar arrangement). The various applications of LCs as biosensors for glucose, protein and peptide detection, biomarkers, drug molecules and metabolites are extensively reviewed. The review also presents applications of LC-based sensors in the detection of heavy metals, anionic species, gases, volatile organic compounds (VOCs), toxic substances and in pH monitoring. Additionally discussed are the various ways in which LCs have been used in the field of material science. Specific attention has been given to the sensing mechanism of each sensor and it is important to note that in all cases, LC-based sensing involves some form of orientational transition of the LC molecules in the presence of a given analyte. Finally, the review concludes by giving future perspectives on LC-based sensors.  相似文献   

18.
To investigate the behavior of chemiresistive vapor sensors operating below or around the percolation threshold, chemiresistors have been formed from composites of insulating organic polymers and low mass fractions of conductive carbon black (CB, 1-12% w/w). Such sensors produced extremely large relative differential resistance changes above certain threshold vapor concentrations. At high analyte partial pressures, these sensors exhibited better signal/noise characteristics and were typically less mutually correlated in their vapor response properties than composites formed using higher mass fractions of CB in the same set of polymer sorption layers. The responses of the low-mass-fraction CB sensors were, however, less repeatable, and their nonlinear response as a function of analyte concentration required more complicated calibration schemes to identify and quantify analyte vapors to compensate for drift of a sensor array and to compensate for variability in response between sensor arrays. Because of their much larger response signals, the low-mass-fraction CB sensors might be especially well suited for use with low-precision analog-to-digital signal readout electronics. These sensors serve well as a complement to composites formed from higher mass fractions of CB and have yielded insight into the tradeoffs of signal-to-noise improvements vs complexity of signal processing algorithms necessitated by the use of nonlinearly responding detectors in array-based sensing schemes.  相似文献   

19.
Herein we report the combination of a library of resin-bound sensors along with a multicomponent sensor array. This novel combinatorial array sensor system shows selectivity for nucleotide phosphates in solution. The design of the anchored receptor includes a 1,3,5-trisubstituted-2,4,6-triethylbenzene scaffold coupled with peptide libraries. Each chemosensor is placed into a micromachined cavity within a silicon wafer, and the optical changes observed by a charged-coupled device result in near-real-time digital analysis of solutions. A colorimetric displacement assay was performed, and time-dependent imaging studies of the selected sensing ensembles result in a differential responses upon addition of adenosine 5'-triphosphate (ATP), adenosine 5'-monophosphate (AMP), or guanosine 5'-triphosphate (GTP). An advantage to this approach is that it creates an array of sensors that gives a fingerprint response for each analyte. Principal component analysis indicates that the library of chemosensors can differentiate between ATP, GTP, and AMP. On the basis of factor loading values, individual sensors from the library were sequenced to elucidate their chemical composition.  相似文献   

20.
Reliable sensing of structurally similar anions in water is a difficult problem, and analytical tests and sensor devices for reliable sensing of multiple anions are very rare. This study describes a method for fabrication of simple colorimetric array-based assays for aqueous anion solutions, including complex analytes encountered in real-life applications. On the fundamental level, this method shows how the discriminatory capacity of sensor arrays utilizing pattern recognition operating in multianalyte environments may be dramatically improved by employing two key features. The synergy between the sensor and hydrogel host resembles the cooperative effects of an apoenzyme and cofactor: the host hydrogel helps extract the target anions from the bulk analyte while stripping the solvate molecules off the anions. In addition, the supramolecular studies of the affinity and selectivity of the potential sensors for target analytes allow for constructing an array predesigned for a particular analyte. To illustrate both aspects, an eight-sensor array utilizing colorimetric sensor materials showing selectivity for fluoride and pyrophosphate while displaying significant cross-reactivity for other anions such as carboxylates, phosphate, or chloride was used to differentiate between 10 anions. The quantitative analyses were also performed to show that the eight-sensor array was found to operate across 4 orders of magnitude concentrations (0.20-360 ppm; 10 microM to 20 mM). The applicability of this approach was demonstrated by analyzing several toothpaste brands. The toothpastes are complex analytes comprising both known and unknown anions in various concentrations. The fluoride-selective yet cross-reactive array is shown to utilize the fluoride content as the main differentiating factor while using the remaining anionic components for further differentiation between toothpaste brands.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号