首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Changes in mobile phase composition during high performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray operation modes. In this work, we identify the influences of dynamic changes in bulk conductivity on the cone-jet stability island for aqueous acetonitrile and aqueous methanol mobile phases commonly used in reversed-phase HPLC. Bulk conductivities of the mobile phases were varied by adding different amounts of formic acid. A commercial microchip-HPLC/ESI-MS configuration was modified to enable in situ electrospray diagnostics by frequency analysis of the microchip emitter current and spray imaging. This approach facilitated the detection of different spray modes together with their onset potentials. The established spray modes are described and the differences in onset potentials and stability regions explained by the physicochemical properties of the electrosprayed liquid.  相似文献   

2.
Capillary liquid chromatography based on particulate and monolithic stationary phases was used to screen complex peptide libraries by fast gradient elution coupled on-line to electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). A slightly modified commercial electrospray interface consisting of a fused-silica transfer capillary and low dead volume stainless steel union at which the electrospray voltage was grounded enabled the effluent of all the capillary columns to be directly sprayed into the mass spectrometer. Stable electrospray conditions were generated over a wide range of mobile phase compositions, alleviating the need for a tapered end of the spray capillary, pneumatic assistance or preheated nebulizer gas. Since the identification of complex samples containing numerous isobaric substances is facilitated by chromatographic separation prior to mass spectrometry, stationary phase materials have been employed which offer a fast, efficient elution and, due to the complexity of samples, a high loading capacity. Silica-based monolithic capillary columns combine these three characteristics in a unique manner due to a tailored adjustment of both macro- and mesopore sizes in the highly porous silica structure. As we demonstrate by a comparative study of the silica-based monolithic and packed capillaries for LC/MS analysis of complex peptide libraries, silica monoliths show superior performance over packed beds of small-diameter particles with respect to analysis time and separation efficiency. Libraries with more than 1000 different peptides could be screened in less than 20 min.  相似文献   

3.
A pressurized liquid junction nanoelectrospray interface was designed and optimized for reliable on-line CE-MS coupling. The system was constructed as an integrated device for highly sensitive and selective analyses of proteins and peptides with the separation and spray capillaries fixed in a pressurized spray liquid reservoir equipped with the electrode for connection of the electrospray potential. The electrode chamber on the injection side of the separation capillary and the spray liquid reservoir were pneumatically connected by a Teflon tube filled with pressurized nitrogen. This arrangement provided precisely counterbalanced pressures at the inlet and outlet of the separation capillary. The pressure control system was driven by an electrically operated valve and maintained the optimum flow rate for the electrospray stability. All parts of the interface being in contact with the CEBGE, spray liquid and/or sample were made of glass or Teflon. The use of these materials minimized the electrospray chemical noise often caused by plastic softeners or material degradation. During optimization, the transfer of the separated zones between the separation and electrospray capillaries was monitored by UV absorbance and contactless conductivity detectors placed at the outlet of the separation capillary and inlet of the electrospray tip, respectively. This arrangement allowed independent monitoring of the effects of pressure, CE voltage and geometry of the liquid junction on the spreading and dilution of the separated zones after passage through the interface.  相似文献   

4.
Hyung SW  Kim MS  Mun DG  Lee H  Lee SW 《The Analyst》2011,136(10):2100-2105
The microcapillary liquid chromatography (μLC)/tandem mass spectrometry (MS/MS) system has become a prevailing analytical platform in proteomics. Typical proteomic studies aimed at proteome-wide identification of peptides and proteins rely heavily on producing an accurate and reproducible solvent-composition gradient throughout microcapillary separation columns to improve LC separation. With the recent advent of targeted proteomic approaches utilizing the LC retention time as a physicochemical parameter for peptides, high reproducibility of LC separation additionally becomes an important factor. In this study, column temperature elevation is utilized to improve reproducibility and separation efficiency of the μLC-MS/MS system. The simple incorporation of a semi-rigid gas line heater allowed precise control of the temperature of microcapillary columns longer than 70 cm, up to 60 °C. Tryptic enolase peptides were used as a standard sample to evaluate the effect of the controlled temperature elevation on the peptide separation efficiency and reproducibility. In addition to the increased reproducibility in peptide elution time due to the controlled column temperature, the temperature elevation resulted in a decrease in the column operation pressure, which, in turn, allowed a higher solvent flow-rate to be employed using the same LC pumps, leading to further improvements in the performance of μLC systems.  相似文献   

5.
Probe electrospray ionization (PESI) has recently been developed, in which the electrospray was generated from a solid needle instead of by using a capillary. In this paper, the characteristics of probe electrospray ionization were studied based on the measurement of spray current, optical microscopy, and PESI mass spectrometry. In the experiment, the solid needle was moved up and down a vertical axis, and a small amount of sample was repeatedly loaded to the needle when the tip of the needle touched the surface of the liquid sample at the lowest position. After the application of high voltage, a liquid droplet was formed on the tip of the solid needle probe, with its size was determined by the size of the needle tip. The liquid flow rate to the tip, as indicated by the spray current, depends on the voltage applied to the needle as well as the loaded liquid amount. Stable electrospray can be maintained until the total consumption of liquid sample. The kilohertz current pulsation takes place in the case of overloading the sample to the needle. The influences of the applied voltage and the liquid flow rate on the PESI mass spectra were also examined.  相似文献   

6.
Optimal liquid chromatography/mass spectrometric [LC/MS(/MS)] analysis depends on both the LC selectivity and the electrospray efficiency. Here, we outline a simple and comprehensive LC/MS/MS strategy for the rapid analysis of a wide range of pharmaceutical compounds. To achieve ultrafast LC separation with little sacrifice in peak capacity, one needs to start with a column that provides a good peak capacity at short gradient run times; secondly, it is important to use high flow rates to achieve a good gradient peak capacity. Following this strategy, it was possible to baseline-resolve a mixture (containing acidic, neutral, and basic pharmaceutical analytes) in seconds. By coupling the selectivity provided by fast LC separation with the specificity of MS/MS detection, it is possible to separate and identify a wide range of analytes in 1-min gradient analyses. Also, the impact of mobile phase pH on both the chromatographic selectivity and the MS/MS sensitivity is demonstrated.  相似文献   

7.
液相色谱-串联质谱法检测食品中的多种易滥用着色剂   总被引:4,自引:0,他引:4  
Yi X  Deng X  Yang H  Guo D  Zhu J 《色谱》2011,29(11):1062-1069
建立了硬糖、果酱、液态奶、果汁中酸性红52、红色2G、喹啉黄、专利蓝、酸性红26、柠檬黄、靛蓝、胭脂红、诱惑红、日落黄、亮蓝、苋菜红等12种易滥用着色剂残留量的液相色谱-串联质谱分析方法。样品用水溶液稀释提取,经聚酰胺固相萃取柱净化后,在Agilent XDB-C18色谱柱分离,以20 mmol/L乙酸铵溶液和乙腈为流动相进行梯度洗脱。质谱采用电喷雾负离子(ESI~)模式电离,多反应监测(MRM)模式检测,基质匹配标准溶液外标法定量。易滥用着色剂在0.5~50 mg/L范围内呈线性相关,相关系数(r)均大于0.99,其定量限(信噪比大于10)为0.5 mg/kg,检出限(信噪比大于3)为0.1 mg/kg。各种基质样品在0.5、5和50 mg/kg添加水平时,易滥用着色剂的回收率范围为62.6%~115.3%,相对标准偏差(RSDs)为2.6%~26.3%,可以满足食品中易滥用着色剂含量的检测需要。  相似文献   

8.
The transfer of a gradient method to an isocratic or multistep gradient method employing stationary phase optimized liquid chromatography facilitated a reduction in analysis time by 50% and significantly improved the mass spectrometric detectability of impurities in synthetic thyroid hormones. Four column segments packed with different stationary phases were combined into a single chromatographic column, which allowed the separation and photometric as well as mass spectrometric detection of thyroid compounds in less than 30 min under isocratic- or step gradient elution conditions with 0.10% acetic acid/acetonitrile. Signal instability and baseline drift during detection by negative electrospray ionization time-of-flight mass spectrometry were minimized by optimizing the spray parameters for each individual elution step. This resulted in improved detectabilities and higher mass spectral quality, especially for low-abundance components in the sample mixture. The method was applied to the separation and detection of the low-abundance impurities formed upon the thermal stressing of a sample of synthetic levothyroxine.  相似文献   

9.
A parallel spray interface for mass spectrometry is described. This new electrospray interface enables effluent flow streams from an array of HPLC columns to be sampled independently and sequentially on a chromatographic time-scale. Unlike our previously reported parallel LC-MS interface, which incorporated a dual-sheath spray interface accommodating up to four flow streams that are sampled simultaneously, this new interface permits up to four columns to be sampled sequentially by means of a stepping motor and rotating plate assembly. Effluent flow streams from an array of four HPLC columns are connected to a parallel arrangement of electrospray needles co-axial to the mass spectrometer entrance aperture. Within the needle assembly, the individual spray tips are oriented in a circular array, where each needle is situated 90 degrees relative to one another for four-column operation. An eight-column system is described with needles spaced at 45 degree intervals. In between the needle assembly and the mass spectrometer entrance aperture is a Teflon disk with a through-hole that is mounted to a stepping motor assembly. By precisely controlling the stepping of the motor assembly, it is possible to sample each of the spray positions multiple times per second. By operating the quadrupole mass spectrometer in the single ion monitoring (SIM) mode, it was possible to acquire data at each of the spray positions during the course of the elution of compounds from the HPLC column array while maintaining both good sensitivity and peak shape. Preliminary results suggest this technique will be useful for high throughput combinatorial library analysis and profiling.  相似文献   

10.
A system is described which allows operation of a range of capillary based liquid phase separations including capillary electrophoresis, isocratic and gradient capillary electrochromatography, isocratic and gradient capillary liquid chromatography and electrically assisted gradient capillary liquid chromatography. The system was coupled to electrospray ionization mass spectrometry in the electrically assisted capillary liquid chromatography mode to investigate the effect of applied voltage on the selectivity in peptide mapping separations. Analyses were performed on tryptic digests of recombinant human growth hormone and tissue plasminogen activator. The results show a small but useful effect on selectivity that can be used to fine tune specific separations.  相似文献   

11.
A liquid chromatography/mass spectrometry (LC/MS) method using desorption electrospray ionization (DESI) as a versatile interface has been established, which allows a wide range of elution flow rates, online derivatization via reactive DESI and further combination with electrochemistry.  相似文献   

12.
Modafinil, adrafinil and their related substances were synthesized and analyzed by RP‐LC with ESI‐MS/MS. The ionization mode, polarity, cone voltage, and chromatographic conditions were evaluated. The optimum LC‐MS conditions to obtain fragment ions indispensable for identification of the structures were described. The bulk drugs purity of modafinil and adrafinil was evaluated on Kromasil C18 column with ACN/0.02 M ammonium acetate as mobile phase in gradient elution mode at 30°C. The method was found to be suitable not only for monitoring the reactions during the process development but also for quality assurance of modafinil and adrafinil.  相似文献   

13.
Quantitative analysis of liquid chromatography (LC)-mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data is essential to many proteomics studies. We have developed MASIC(2) to accurately measure peptide abundances and LC elution times in LC-MS/MS analyses. This software program uses an efficient processing algorithm to quickly generate mass specific selected ion chromatograms from a dataset and provides an interactive browser that allows users to examine individual chromatograms with a variety of options.  相似文献   

14.
A methodology has been developed for the rapid identification of gel separated proteins. Following in gel protein digestion with trypsin, the resulting peptide mixture is analyzed by on-line liquid chromatography, electrospray mass spectrometry (LC/MS). The mass spectral data containing either accurate mass values or sequence specific fragment ion information is then matched to a database of known protein sequences. Key features of the LC/MS system are the use of a novel integrated, microscale LC column-electrospray interface and variable flow solvent delivery to optimize the efficiency of sample loading and gradient elution. With these enhancements, only 10 min is required to analyze each sample. The method is routine for sample amounts ranging from 50 to 500 fmol. The analysis parameters for the ion trap mass spectrometer have to be carefully adjusted in order to keep pace with the rapidly eluting LC peaks. Although designed for rapid LC separations, the integrated column-electrospray interface is also able to provide extended analyses of selected components using a technique known as “peak parking. ”  相似文献   

15.
This paper explores the changes in the electrospray signal response of 39 structurally different compounds caused by the quality of the methanol, when used as a component in a gradient elution mobile phase. When three batches of LC–MS grade methanol from one manufacturer were evaluated, the largest variation in the electrospray signal responses of the 39 compounds examined was 18%. However, significant enhancement of the electrospray signals of up to 106% were observed among different brands of LC–MS grade methanol from different manufacturers. The effect of methanol quality on signal response was found to be compound dependent. This study also demonstrated that the senescence of the methanol was important. Using an expired batch of LC–MS grade methanol, electrospray signals were suppressed by as much as 95% for all compounds measured using positive mode electrospray. Conversely, the negative mode electrospray signals of compounds such as 4-octyl benzoic acid showed an enhancement of up to 96% when using the same batch of methanol. Linuron was used as a model compound to examine the change in the electrospray response, during gradient elution, when the proportion of an expired batch of methanol was varied. An infusion experiment showed that the linuron signal intensity decreased as the proportion of expired methanol increased in the mobile phase, which was in direct contrast to the increase in linuron signal observed with a non-expired batch of methanol. A series of isocratic experiments also showed that the linuron signal decreased as the proportion of expired methanol increased in the mobile phase. The ion ratios of several of the compounds studied changed significantly when using the expired batch of LC–MS methanol. The change in the ion ratios accentuates the difficulty of identifying compounds from in-source spectral libraries. A protocol is recommended for assessing the quality of methanol for LC–MS applications.  相似文献   

16.
The feasibility of developing a multi-component bioanalytical method using high-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) is demonstrated using nefazodone and its two metabolites as model compounds. The performance of the bioanalytical method for the three analytes, with three different compensation voltage (CV) values, is assessed using standard curves and quality control samples, which exhibited good accuracy, precision and ruggedness. The number of analytes with different CV values that can be quantitated simultaneously depends on the acquisition cycle time, which is a function of the FAIMS residence time (fixed), chromatographic peak width and selected reaction monitoring (SRM) dwell time. It is established that CV, the FAIMS selectivity parameter, is reproducible for at least 16 h, thus ensuring the constancy of the CV during a large-batch sample analysis. It is also established that change in mobile phase composition or of flow rate does not cause a shift in CV. Thus, CV values determined from a CV scan via infusion of a sample can be used for an LC/ESI-FAIMS-M/MS method based on isocratic or gradient elution.  相似文献   

17.
An adjustable low-mass filter has been developed for an electrospray ionization (ESI) source to block ions associated with unwanted background species from entering the mass spectrometer. The low-mass filter is made by using an adjustable potential energy barrier from the conductance-limiting plate of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from exiting the ESI source. We show that this arrangement provides a linear voltage adjustment for low-mass filtering from m/z 0 to 500. Mass filtering above m/z 500 is also performed; however, higher-mass species are attenuated. The mass filter was tested with a liquid chromatography/mass spectrometry (LC/MS) analysis of a bovine serum albumin (BSA) tryptic digest and resulted in the ability to block low-mass, background species, which accounted for 40-70% of the total ion current immediately behind the ESI source during peak elution and detection.  相似文献   

18.
A liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) multi-residue method for the simultaneous target analysis of a wide range of pesticides and metabolites in fruit, vegetables and cereals has been developed. Gradient elution has been used in conjunction with positive mode electrospray ionization tandem mass spectrometry to detect up to 171 pesticides and/or metabolites in different crop matrices using a single chromatographic run. Pesticide residues were extracted/partitioned from the samples with acetone/dichloromethane/light petroleum. The analytical performance was demonstrated by the analysis of extracts from lettuce, orange, apple, cabbage, grape and wheat flour, spiked at three concentration levels ranging from 0.01 to 0.10 mg/kg for each pesticide and/or metabolite. In general, recoveries ranging from 70 to 110%, with relative standard deviations better than 15%, were obtained. The recovery and repeatability data are in good accordance with EU guidelines for pesticide residue analysis. The limit of quantification for all targeted pesticides and metabolites tested was 0.01 mg/kg. The selectivity and robustness of the LC-MS/MS method was demonstrated by a 1-year comparison of its analytical results with those obtained from our validated GC and LC multi-residue methods applied to more than 3500 routine samples. The validated LC-MS/MS method has been implemented in our analytical scheme since 2004, replacing four of the conventional detection methods, i.e. GC-flame-photometric detection (acephate, methamidophos, etc.), GC-nitrogen-phosphorus detection, LC-UV detection (carbendazim, thiabendazole, imazalil and prochloraz) and LC-fluorescence detection (N-methylcarbamate pesticides). During a 3-year period, the LC-MS/MS method has been applied to the analyses of more than 12,000 samples.  相似文献   

19.
建立了采用增强型脂质去除(EMR-Lipid)固相小柱净化结合液相色谱-串联质谱(LC-MS/MS)测定猪肉和猪肝中双甲脒 (AMZ) 及其3种代谢物2,4-二甲基苯胺(DMA)、单甲脒(DMPF)和2,4-二甲基苯基甲酰胺(DMF)残留量的方法。 样品经乙腈蛋白沉淀及盐析提取,通过Captiva EMR-Lipid 过滤小柱净化,滤膜过滤后,采用Agilent ZORBAX Eclipse Plus C18柱(50 mm×2.1 mm,1.8 μm)分离,以0.1%甲酸水溶液与0.1%甲酸乙腈为流动相进行梯度洗脱,采用电喷雾离子源正离子方式扫描,多反应监测模式进行检测。 结果表明,在猪肝与猪肉中AMZ、DMA线性范围为1~200 μg/kg,DMPF和DMF的线性范围为0.1~200 μg/kg,相关系数(R2)均大于0.991;AMZ、DMA、DMPF和DMF的方法定量限(S/N=10)分别为0.6、0.6、0.05、0.05 μg/kg;对空白猪肉和猪肝进行0.1、1、5、50 μg/kg 4个浓度水平的加标实验,回收率在60.2%~127.4%之间,相对标准偏差均低于12%。 该方法简便、快捷,适用于猪肉和猪肝中双甲脒及其代谢物残留量的同时测定。  相似文献   

20.
Low-flow electrospray ionization is typically a purely electrostatic method, used without supporting sheath-gas nebulization. Complex spray morphology results from a large number of possible spray emission modes. Spray morphology may assume the optimal Taylor cone-jet spray mode under equilibrium conditions. When coupling to nanobore gradient elution chromatography, however, stability of the Taylor cone-jet spray mode is compromised by the gradient of mobile phase physiochemical properties. The common spray modes for aqueous/organic mobile phases were characterized using orthogonal (strobed illumination) transmitted light and (continuous illumination) scattered light imaging. Correlation of image sets from these complementary illumination methods provides the basis for spray mode identification using qualitative and quantitative image analysis. An automated feedback-controlled electrospray source was developed on a computer capable of controlling electrospray potential using an image-processing based algorithm for spray mode identification. The implementation of the feedback loop results in a system that is both self-starting and self-tuning for a specific spray mode or modes. Thus, changes in mobile phase composition and/or flow rate are compensated in real-time and the source is maintained in the cone-jet or pulsed cone-jet spray modes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号