首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Feng J  Sun M  Xu L  Li J  Liu X  Jiang S 《Journal of separation science》2011,34(18):2482-2488
Multi-walled carbon nanotubes-coated solid-phase microextraction fiber was prepared by a novel protocol involving mussel-adhesive-protein-inspired polydopamine film. The polydopamine was used as binding agent to immobilize amine-functionalized multi-walled carbon nanotubes onto the surface of the stainless steel wire via Michael addition or Schiff base reaction. Surface properties of the fiber were characterized by field emission scanning electron microscope and X-ray photoelectron spectroscope. Six phenols in aqueous solution were used as model compounds to investigate the extraction performance of the fiber and satisfactory results were obtained. Limit of detection was 0.10 μg/L for 2-methylphenol (2-MP) and 4-methylphenol (4-MP), and 0.02 μg/L for 2-ethylphenol (2-EP), 4-ethylphenol (4-EP), 2-tert-butylphenol (2-t-BuP), and 4-tert-butylphenol (4-t-BuP), which were much lower than commercial fiber and fibers made in laboratory. RSDs for one unique fiber are in the range of 1.92-7.00%. Fiber-to-fiber (n=3) reproducibility ranges from 4.44 to 8.41%. It also showed very high stability and durability to acid, alkali, organic solvent, and high temperature. Real water sample from Yellow river was applied to test the reliability of the established solid-phase microextraction (SPME)-GC method and recoveries with addition level at 5 and 100 μg/L were in the range from 81.5 to 110.0%.  相似文献   

2.
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1-100 ng/mL (R2 = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment.  相似文献   

3.
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L?1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.  相似文献   

4.
This study is the development of a new solid phase extraction method based on using magnetic multiwalled carbon nanotubes impregnated with 1-(2-pyridylazo)2-naphthol (PAN) for separation, preconcentration, and flame atomic absorption spectrometric determination of Pb(II) and Cu(II). Optimization of the method was done by investigating pH effect, amount of magnetic multiwalled carbon nanotubes impregnated with PAN, eluent type and volume, matrix effects, and volume of the sample. The optimum adsorbent amount was found to be 75 mg and the optimum pH value was found as 5.5. The detection limits were 16.6 μg L-1 for Pb(II) and 18.9 μg L-1 for Cu(II). The relative standard deviations (RSD%) were less than 4%. Two certified reference materials: SPS-WW2 wastewater and NCS-DC73349 (bush branches and leaves) were used to test the validation of the method. The method was successfully applied to the analysis of Pb(II) and Cu(II) ions in daisy, mint, paprika, sage, rosemary, daphne leaves, heather, green tea, andViburnum opulussamples.  相似文献   

5.
A coprecipitation method using a combination of 2-mercaptobenzothiazole (MBT) as a chelating reagent and copper as the coprecipitate carrier is described for the determination of trace lead and cadmium by flame atomic absorption spectrometry. The coprecipitation conditions, such as the effect of pH, the amount of carrier element and reagent, standing time, sample volume and matrix effects were examined in detail. It was found that lead and cadmium are coprecipitated quantitatively (≥95%) with Cu(II)-MBT at pH 9 and that the relative standard deviations (n = 7) were ≤1.6%. When using the enrichment factors of 150-fold for lead and cadmium, the detection limits (3s/b) obtained are 1.08 for lead and 0.04 μg L−1 for cadmium. The method was validated with spiked sea water, stream water, well water, and vegetable samples.  相似文献   

6.
Multiwalled carbon nanotubes chemically functionalized with 2-((3-silylpropylimino) methyl) phenol (SPIMP-MWCNT) and successfully applied for the solid phase extraction (SPE) of some metal ions in food samples. The influences of the analytical parameters including pH, amounts of solid phase, eluent conditions (type, volume and concentrations), sample volume and interference of some metal ions on the recoveries of ions Cu2+, Pb2+, Fe2+, Ni2+ and Zn2+ ion were investigated. The metal ions retained on SPIMP-MWCNT was eluted using 6?mL of 4?mol?L?1 HNO3 solution and their content was determined by flame atomic absorption spectrometry (FAAS) with recoveries more than 95% and relative standard deviations (n?=?5) between 2.4–3.4% for both reproducibility and repeatability. The detection limit of this metal ions was between 1.0–2.6?ng?mL?1 (3S b , n?=?10) and their preconcentration factor was 100, while their loading capacity was above 32.9?mg?g?1 of SPIMP-MWCNT. The proposed method was successfully applied for the preconcentration and determination of analytes in different samples.  相似文献   

7.
The effect of dimensions (length and external diameter) of multi-walled carbon nanotubes (MWCNTs) on its preconcentration efficiency towards some metal ions (Pb2+, Cd2+, Cu2+, Zn2+ and MnO4) from environmental waters prior to their analysis by flame atomic absorption spectroscopy (FAAS) was investigated. MWCNTs (as-received from the manufacturer) of various external diameters and lengths were involved. Other variables optimized included effects of pH of water sample, composition and volume of eluent, mass of the MWCNTs, breakthrough volume and coexisting ions. Maximum recovery of metal ions was obtained at pH 9 where it was thought that precipitation of metals as their hydroxides played the major factor in metals uptake by MWCNT. It was suggested that the use of appropriate dimensions of MWCNTs may support the trapping process of the precipitated metal hydroxides by MWCNTs. It was found that long MWCNT of length 5-15 μm and external diameter 10-30 nm gave the highest enrichment efficiency towards almost all the targeted metal ions. It could be used for preconcentration of MnO4, Cu2+, Zn2+ and Pb2+ with almost full recovery; but not for Cd2+ due to its low recovery. The optimized solid phase extraction (SPE) procedure was capable of determining metal ions in the linear range 20-100 ng mL−1 (except for Zn2+ from 20 to 150 ng mL−1). Detection limits were 0.709 ng mL−1 for MnO4, 0.278 ng mL−1 for Pb2+, 0.465 ng mL−1 for Cu2+, 0.867 ng mL−1 for Zn2+. Application of the optimized SPE procedure to environmental waters (tap water, reservoir water and stream water) gave spike recoveries of the metals in the range of 81-100%.  相似文献   

8.
Fe3O4 nanoparticles coated with SiO2 and modified with ammonium pyrrolidine dithiocarbamate as a new adsorbent for the single-step extraction and preconcentration of trace amounts of copper and nickel from tobacco samples were prepared. The particle sizes of nanoparticles were characterised by transmission electron microscope. Several parameters affecting the analytical performance, such as the amount of ammonium pyrrolidine dithiocarbamate, amount of magnetic nanoparticles, pH, contact time, coexisting ions, desorption solution and reuse times of magnetic solid-phase extraction, were discussed and optimised. The analytes desorbed from magnetic nanoparticles were determined by flame atomic absorption spectrometry. Under the optimum conditions, the analytical linear ranges were 0.02–15 mg/L for Cu and 0.02–20 mg/L for Ni (R2 > 0.9992). The relative standard deviations (RSDs, n = 5) of 1.8% and 2.1% were obtained for Cu and Ni, respectively. The method detection limits were 0.0028 μg/g for Cu and 0.0037 μg/g for Ni. The proposed method was successfully applied to tobacco sample analysis and got excellent recoveries in the range of 89.6–102.3% and RSDs (n = 5) of 1.2–2.5%. This method is much faster and more effective than traditional methods, and it is promising for the analysis of heavy metals.  相似文献   

9.
Fang Wu  Wanping Lu  Wei Liu 《Talanta》2010,82(3):1038-57
Using a single-walled carbon nanotubes (SWCNTs) as stationary phase of solid-phase microextraction (SPME) fibers, a simple, low cost and environmentally friendly method for extraction of 13 pesticides in Tea samples has been developed following gas chromatography-mass spectrometric determination. Potential factors affecting the extraction efficiency were investigated and optimized, including extraction and desorption time, extraction temperature, stirring rate, solution pH and ionic strength. Under optimized conditions, the linearity of the developed method was in the range of 0.125-25 ng/mL with correlation coefficients greater than 0.9928 and the limits of detections (LODs) were 0.027-0.23 ng/mL (S/N = 3). Meanwhile, the relative standard deviations (RSDs) for five successive measurements with single fiber, fiber-to-fiber, day-to-day were 2.3-13.0, 8.2-14.6 and 4.1-12.5%, respectively, indicating good reproducibility of the proposed method. The fiber had high extraction efficiency for studied pesticides in comparison with commercial poly(dimethylsiloxane) (PDMS) and polyacrylate (PA) fibers and could be used for more than 70 times without decrease of efficiency. The developed method was successfully applied for the analysis of real samples including green Tea, oolong Tea, white Tea, and flower Tea, and the recoveries of the pesticides spiked in these samples ranged from 75.1 to 118.4%. Chlorfenapyr and λ-cyhalothrin were found in the Tea samples bought randomly from local market. The results demonstrated that the developed SWCNTs-SPME method was a simple, efficient pretreatment and enrichment procedure for pesticides in complex matrices.  相似文献   

10.
周喜  葛鑫  唐荣芝  陈彤  王公应 《催化学报》2014,35(4):481-489
制备了表面修饰多壁碳纳米管负载TiO2的催化剂,并将其应用于碳酸二甲酯与苯酚的酯交换反应. 采用X射线电子能谱、透射电子显微镜、低温N2吸附-脱附和X射线衍射等对催化剂进行了表征. 结果表明,以低浓度的氨水(0.4%)代替去离子水作为沉淀剂时,制备的催化剂显示出更好的催化活性、分离性与重复使用性. 考察了TiO2负载量、催化剂用量及反应时间对反应性能的影响. 在最佳反应条件下,苯酚转化率为42.5%,碳酸甲苯酯与碳酸二苯酯的总选择性达到99.9%以上. 经过4次重复使用后,催化剂的活性略有下降.  相似文献   

11.
A micro-column packed with PDDA-wrapped MWNTs in sequential injection system facilitates selective sorption of acidic protein species. Proteins adsorbed onto the PDDA-MWNT composites are afterwards collected by elution with a citrate buffer as stripping reagent. With a sample loading volume of 2.0 mL and an eluent volume of 200 microL, a retention efficiency of 100% and a recovery of 90% are achieved for BSA in the range 6-120 microg, resulting in an enrichment factor of 14. A sampling frequency of 15 h(-1) is achieved, along with a precision of 4.5% at 25 microg x mL(-1) BSA. The practical applicability of this system is demonstrated by processing human whole blood for successive isolation of acidic proteins.  相似文献   

12.
In this work, a solid phase extraction method has been developed using a column filled with double-walled carbon nanotubes (DWNT) for preconcentration-separation of gold(III) ions prior to their flame atomic absorption spectrometric determination. Gold(III) ions were quantitatively recovered on DWNT in 1.0?mol?L?1 HCl. The influences of the analytical conditions including eluent type, sample volume, etc. on the recoveries of gold(III) ions were examined. The effects of concomitant ions were also investigated. The detection limits for gold(III) based on 3σ was calculated as 1.5?µg?L?1. The procedure presented in this paper was applied to the gold content of a number of water, geological and anodic slime samples with successful results.  相似文献   

13.
建立了以二乙基二硫代氨基甲酸钠为配位剂,十二醇为萃取剂,乙醇为分散剂的悬浮固化分散液-液微萃取—火焰原子吸收光谱法测定水样中痕量铅的方法。详细探讨了影响萃取效率的因素。优化条件为:二乙基二硫代氨基甲酸钠的用量为10-6 mol,十二醇体积为90.00μL,乙醇体积为1.00 mL,pH为7.00。在最佳条件下,铅的检出限为1.12μg/L,富集倍率为16.00,线性范围5.00~600.00μg/L,对含有20.00μg/L和600.00μg/L Pb的标准溶液平行萃取测定11次,测定结果的RSD分别为3.73%和2.62%。本方法应用于自来水、河水及海水中痕量铅的分析,加标回收率为90.10%~100.70%。  相似文献   

14.
通过以Nation为黏合剂、不锈钢丝为涂层载体,制备了多壁碳纳米管固相微萃取纤维.该纤维的制备方法快速、简便、成本低,并具有热稳定性好(300℃)、使用寿命长(〉100次)、对多溴联苯萃取效率高等特点.研究优化了影响萃取及分离效率的解吸温度和时间、萃取时间、搅拌速度、盐度等实验条件,进行了海水中多溴联苯的测定.对一溴联苯的线性范围为0.1-5.0ng/mL,而二溴联苯、三溴联苯、四溴联苯和五溴联苯的线性范围均为0.01~5.0ng/mL.方法的检测限为0.1~0.8ng/L.在优化的条件下分别测定了0.1和1ng/mL多溴联苯的海水加标样品,回收率在91.1%~107.3%之间,相对标准偏差小于12%.该方法分析时间短、灵敏度高、操作简便,适用于水样中多溴联苯的痕量分析.  相似文献   

15.
Yue Liu  Zhi-Qiang Wu 《Talanta》2009,79(5):1464-57
Hexahistidine-tagged protein functionalized multi-walled carbon nanotubes (MWCNTs/6His-tagged protein) were prepared and characterized by ultraviolet-visible spectrophotometry and atomic force microscopy. Both static and dynamical adsorption experiments showed that the MWCNTs/6His-tagged protein served as good sorbent for the solid-phase extraction of Cu2+ and Ni2+. Effective on-line sorption of Cu2+ and Ni2+ on the MWCNTs/6His-tagged protein packed microcolumn was achieved in a pH range of 3.0-4.5 and 4.5-6.0, respectively. The retained Cu2+ and Ni2+ were efficiently eluted with 0.2 mol L−1 imidazole-HCl solution for on-line flame atomic absorption spectrometric determination. The MWCNTs/6His-tagged protein exhibited fairly fast kinetics for the sorption of Cu2+ and Ni2+, and offered up to 20,000 and 1800 times improvement in the tolerable concentrations of co-existing ions over the MWCNTs for solid-phase extraction of Cu2+ and Ni2+, respectively. On-line solid-phase extraction at a flow rate of 5.0 mL min−1 for 60 s gave an enhancement factor of 29 for Cu2+ and 28 for Ni2+, a sample throughput of 45 h−1, and a detection limit (3s) of 0.31 μg L−1 for Cu2+ and 0.63 μg L−1 for Ni2+. The precision for 11 replicate measurements was 2.4% for 10 μg L−1 Cu2+, and 2.5% for 15 μg L−1 Ni2+.  相似文献   

16.
研究了十六烷基三甲基溴化铵(CTMAB)/多壁碳纳米管修饰玻碳电极的制备以及多巴胺和抗坏血酸在该修饰电极上的电化学行为。在CTMAB和多壁碳纳米管的协同作用下,该修饰电极对多巴胺和抗坏血酸均具有显著的催化氧化作用,多巴胺和抗坏血酸的氧化峰电位分别为223mV和15mV,实现了在抗坏血酸共存时测定多巴胺。在pH7.0的磷酸盐缓冲溶液中,多巴胺和抗坏血酸的线性范围分别为2.0×10-6~2.0×10-3mol/L和4.0×10-5~1.0×10-2mol/L,检出限分别为6.0×10-7mol/L和1.0×10-5mol/L。  相似文献   

17.
In this study, poly(ethylene glycol) (PEG) grafted onto multi-walled carbon nanotubes (PEG-g-MWCNTs) were synthesized by the covalent functionalization of MWCNTs with hydroxyl-terminated PEG chains. For the first time, functionalized product of PEG-g-MWCNTs was used as selective stationary phase to prepare the sol-gel solid-phase microextraction (SPME) fiber in combination with gas chromatography-flame ionization detector (GC-FID) for the determination of ultra-trace levels of benzene, toluene, ethylbenzene and o-xylene (BTEX) in real water samples. The PEG-g-MWCNTs were characterized by Fourier transform infrared spectra and also thermo-gravimetric analysis, which verified that PEG chains were grafted onto the surface of the MWCNTs. The scanning electron micrographs of the fiber surface revealed a highly porous structure which greatly increases the surface area for PEG-g-MWCNTs sol-gel coating. This fiber demonstrated many inherent advantages, the main being the strong anchoring of the coating to the fused silica resulting from chemical bonding with the silanol groups on the fused-silica fiber surface. The new PEG-g-MWCNTs sol-gel fiber is simple to prepare, robust, with high thermal stability and long lifetime, up to 200 extractions. Important parameters influencing the extraction efficiency such as desorption temperature and time, extraction temperature, extraction time, stirring speed and salt effect were investigated and optimized. Under the optimal conditions, the method detection limits (S/N=3) were in the range of 0.6-3 pg mL(-1) and the limits of quantification (S/N=10) between 2 and 10 pg mL(-1). The relative standard deviations (RSDs) for one fiber (repeatability) (n=5) were obtained from 4.40 up to 5.75% and between fibers or batch to batch (n=3) (reproducibility) in the range of 4.31-6.55%. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples at 20 pg mL(-1) were from 90.21 to 101.90%.  相似文献   

18.
For the first time, a new platform based on electrochemical growth of Au nanoparticles on aligned multi-walled carbon nanotubes (A-MWCNT) was developed for sensitive lable-free DNA detection of the TP53 gene mutation, one of the most popular genes in cancer research. Electrochemical impedance spectroscopy (EIS) was used to monitor the sequence-specific DNA hybridization events related to TP53 gene. Compared to the bare Ta or MWCNT/Ta electrodes, the synergistic interactions of vertically aligned MWCNT array and gold nanoparticles at modified electrode could improve the density of the probe DNA attachment and resulting the sensitivity of the DNA sensor greatly. Using EIS, over the extended DNA concentration range, the change of charge transfer resistance was found to have a linear relationship in respect to the logarithm of the complementary oligonucleotides sequence concentrations in the wide range of 1.0 × 10−15 − 1.0 × 10−7 M, with a detection limit of 1.0 × 10−17 M (S/N = 3). The prepared sensor also showed good stability (14 days), reproducibility (RSD = 2.1%) and could be conveniently regenerated via dehybridization in hot water. The significant improvement in sensitivity illustrates that combining gold nanoparticles with the on-site fabricated aligned MWCNT array represents a promising platform for achieving sensitive biosensor for fast mutation screening related to most human cancer types.  相似文献   

19.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

20.
The potential of multiwalled carbon nanotubes (MWNTs) as solid-phase extraction adsorbent for the separation and preconcentration of gold has been investigated. Gold could be adsorbed quantitatively on MWNTs in the pH range of 1–6, and then eluted completely with 2 mL of 3% thiourea in 1 mol L− 1 HCl solution at a flow rate of 0.5 mL min− 1. A new method using a microcolumn packed with MWNTs as sorbent has been developed for the preconcentration of trace amount of Au prior to its determination by flame atomic absorption spectrometry. Parameters influencing the preconcentration of Au, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been examined and optimized. Under the optimum experimental conditions, the detection limit of this method for Au was 0.15 µg L− 1 with an enrichment factor of 75, and the relative standard deviation (R.S.D) was 3.1% at the 100 µg L− 1 Au level. The method has been applied for the determination of trace amount of Au in geological and water samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏