共查询到20条相似文献,搜索用时 15 毫秒
1.
Zeliha Erbas Sadin Ozdemir Ersin Kilinc 《International journal of environmental analytical chemistry》2013,93(11):1112-1122
ABSTRACTIn this study, preconcentration and separation of Cu(II) and Pb(II) ions by using Fe3O4@SiO2@Bacillus pumilis before their determinations by flame atomic absorption spectrometry (FAAS) were investigated. The thermophilic Bacillus pumilis were isolated from Meyremderesi spring, ??rnak, Turkey. Effects of important parameters such as pH, adsorbent amount, eluent type, concentration and volume of eluent and sample volume on magnetic solid phase extraction (MSPE) were examined in details. The preconcentration factors for Cu(II) and Pb(II) ions were calculated as 30 and 40, respectively. The accuracy of the proposed extraction procedure was validated analysing certificated reference materials and addition – recovery tests. The concentration of copper and lead were determined in water samples from Turkey by Flame AAS after application developed preconcentration-separation method. 相似文献
2.
An enrichment procedure for cadmium and lead after their solid phase extraction as dibenzyldithiocarbamate chelates on Dowex Optipore V-493 has been established prior to their flame atomic absorption spectrometric determinations. The analytical parameters including pH, amounts of dibenzyldithiocarbamate, sample volume, etc., were investigated. The effects of alkaline and earth alkaline ions and some metal ions on the retentions of analytes on Dowex Optipore V-493 resin were examined. Under the optimized conditions, the detection limits (3s, n = 21) for cadmium and lead were 0.43 μg L−1 and 0.65 μg L−1, respectively. The relative standard deviation (R.S.D.), and the recoveries of standard addition for this method were lower than 5% (n = 11) and 95-102%, respectively. Three standard reference samples (LGC 6010 Hard drinking water, NIST SRM 2711 Montana soil and GBW 07605 Tea) were introduced for accuracy and precision of analytical data. The proposed solid phase extraction system was successfully applied to the analysis of environmental samples. 相似文献
3.
This study is the development of a new solid phase extraction method based on using magnetic multiwalled carbon nanotubes impregnated with 1-(2-pyridylazo)2-naphthol (PAN) for separation, preconcentration, and flame atomic absorption spectrometric determination of Pb(II) and Cu(II). Optimization of the method was done by investigating pH effect, amount of magnetic multiwalled carbon nanotubes impregnated with PAN, eluent type and volume, matrix effects, and volume of the sample. The optimum adsorbent amount was found to be 75 mg and the optimum pH value was found as 5.5. The detection limits were 16.6 μg L-1 for Pb(II) and 18.9 μg L-1 for Cu(II). The relative standard deviations (RSD%) were less than 4%. Two certified reference materials: SPS-WW2 wastewater and NCS-DC73349 (bush branches and leaves) were used to test the validation of the method. The method was successfully applied to the analysis of Pb(II) and Cu(II) ions in daisy, mint, paprika, sage, rosemary, daphne leaves, heather, green tea, andViburnum opulussamples. 相似文献
4.
A simple and versatile protocol, based on use of solid phase extraction on strong ion exchangers and off-line detection by flame atomic absorption spectrometry, was devised to fractionate iron and zinc in common dietary food and beverages products, i.e., bee honeys, fruit juices and tea infusions. In the procedure proposed, cation exchanger Dowex 50Wx4 and anion exchanger Dowex 1x4 were used separately for distinguishing broadly meant the cationic metal fraction and the fraction of stable anionic metal complexes, respectively, after retention of metal species and their exhaustive elution by means of a 4.0 mol l−1 HCl solution. The third fraction, referred to the residual metal species, was retrieved by difference between total soluble metal contents and sum of metal quantities in separated cationic and anionic fractions. The fractionation pattern observed for both metals was described and discussed. 相似文献
5.
Moslem Afzali Tayebeh Shamspur Ali Mostafavi 《International journal of environmental analytical chemistry》2019,99(4):328-342
In the present work, a simple procedure is presented for the extraction and determination of pre-concentrated trace amounts of palladium ions through solid phase extraction (SPE) and flame atomic absorption spectrophotometry. This process was performed using Nylon-66/5-(4-dimethylaminobenzylidene) rhodanine composite nanofibres. These nanofibres were produced under optimised conditions via two-axial electrospinning technique and characterised by scanning electron microscopy and Fourier-transform infrared spectroscopy. The effect of experimental parameters including solution pH, the type and volume of eluent and contact time was investigated in extraction and desorption process. Under the optimised conditions, good linearity in the range of 0.07–8 μg L?1 and low detection limit of 0.015 μg L?1 were obtained. High enrichment factor of 187.5 and good relative standard deviation of ±2.2% at 5 μg L?1 of palladium had been achieved. The sorbent capacity for palladium adsorption was obtained 27 mg palladium per gram of nanofibres. So, the SPE was successfully applied to pre-concentrate and determine Pd(II) ions with flame atomic absorption spectrophotometer in real samples. 相似文献
6.
7.
Dakova I Karadjova I Ivanov I Georgieva V Evtimova B Georgiev G 《Analytica chimica acta》2007,584(1):196-203
Ion-imprinted polymer (IIP) particles are prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as crosslinking agent and 2,2′-azo-bis-isobutyronitrile as initiator in the presence of Cu(II), a Cu(II)-4-(2-pyridylazo)resorcinol (Cu(II)-PAR) complex, and PAR only. A batch procedure is used for the determination of the characteristics of the Cu(II) solid phase extraction from the IIP produced. The results obtained show that the Cu(II)-PAR IIP has the greatest adsorption capacity (37.4 μmol g−1 of dry copolymer) among the IIPs investigated. The optimal pH value for the quantitative preconcentration is 7, and full desorption is achieved by 1 M HNO3. The selectivity coefficients (SCu/Me) for Me = Ni(II), Co(II) are 45.0 and 38.5, respectively. It is established that Cu(II)-PAR IIPs can be used repeatedly without a considerable adsorption capacity loss. The determination of Cu(II) ions in seawater shows that the interfering matrix does not influence the preconcentration and selectivity values of the Cu(II)-PAR IIPs. The detection and quantification limits are 0.001 μmol L−1 (3σ) and 0.003 μmol L−1 (6σ), respectively. 相似文献
8.
A tandem column solid phase extraction (SPE) procedure has been devised to examine the fractionation of Fe in wine. Wine was filtered through a 0.45 μm filter and then, the filtrate was driven through an adsorbing Amberlite XAD-7HP column followed by a cation exchange Dowex 50W-x8-200 column. Three different Fe groupings are discriminated and assessed, including hydrophobic species of Fe bound to phenolic substances and related species (phenolic fraction), cationic species comprising simple Fe ions and labile Fe forms (cationic fraction), in addition to anionic and/or neutral Fe complexes with organic acids (residual fraction). The suitability of the procedure has been evaluated analyzing four bottled red wines. The results obtained were verified using another tandem column assemblage in which an adsorbing Amberlite XAD-16 column was exchanged by the Amberlite XAD-7HP column. The fractionation pattern ascertained for Fe in analyzed wines is discussed in reference to previously published works. In addition, a conditioning treatment and preparation of Amberlite XAD resins have been revised. 相似文献
9.
I. López-García P. ViñasR. Romero-Romero M. Hernández-Córdoba 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009
This work presents alternative procedures for the electrothermal atomic absorption spectrometric determination of boron in milk, infant formulas, and honey samples. Honey samples (10% m/v) were diluted in a medium containing 1% v/v HNO3 and 50% v/v H2O2 and introduced in the atomizer. A mixture of 20 µg Pd and 0.5 µg Mg was used for chemical modification. Calibration was carried out using aqueous solutions prepared in the same medium, in the presence of 10% m/v sucrose. The detection limit was 2 µg g− 1, equivalent to three times the standard error of the estimate (sy/x) of the regression line. For both infant formulas and milk samples, due to their very low boron content, we used a procedure based on preconcentration by solid phase extraction (Amberlite IRA 743), followed by elution with 2 mol L− 1 hydrochloric acid. Detection limits were 0.03 µg g− 1 for 4% m/v honey, 0.04 µg g− 1 for 5% m/v infant formula and 0.08 µg mL− 1 for 15% v/v cow milk. We confirmed the accuracy of the procedure by comparing the obtained results with those found via a comparable independent procedure, as well by the analysis of four certified reference materials. 相似文献
10.
A magnetic solid phase extraction method based on agarose coated magnetic nanoparticles)ACMNPs(coupled to a new magnetic field agitation (MFA) device was developed and investigated for the separation, preconcentration and determination of Pd(II) in aqueous solutions. For the first time, the formation of the nanoparticles and their encapsulation in agarose micro-flakes was conducted in a single step. For this purpose, preparation of the magnetic iron oxide nanoparticles was performed in an alkaline agarose solution. The sizes of Fe3O4 nanoparticles and agarose micro-flakes were 10–14 nm and 90–130 μm, respectively. The nanomagnetic agarose particles were functionalized by iminodiacetic acid and subjected to magnetic field agitation in the MFA device. The influence of different analytical parameters such as pH, ionic strength, type and volume of desorption solvent and amount of the adsorbent on the preconcentration of Pd(II) were investigated. Eight replicated analysis at the optimized conditions, resulted in a recovery of 94.1% with an RSD of 5.2% for Pd(II). The detection limit of the method (3σ) was 47 ng L−1 for the analyte. The method was successfully applied to the determination of Pd(II) in natural water samples. 相似文献
11.
Ivanka Dakova Irina Karadjova Ventsislava Georgieva George Georgiev 《Journal of separation science》2012,35(20):2805-2812
The influence of polymer matrix on the extraction efficiency for Cu(II) and selectivity against metal ions such as Ni(II), Cd(II), Pb(II) of Cu(II) imprinted copolymer gels was described. The functional monomers investigated include the weakly basic 4‐vinylpyridine (4‐VP) and its mixure with the acidic and hydrogen binding methacrylic acid. Copolymer gels were prepared by dispersion cross‐linking copolymerization using Cu(II)–4‐(2‐pyridylazo)resorcinol complex, Cu(II), or 4‐(2‐pyridylazo)resorcinol as templates. The chemical structure and morphology of the Cu(II)‐imprinted microbeads are defined using elemental analysis, Fourier transform infrared spectroscopy, and scanning electron microscopy. Extraction efficiencies of newly synthesized sorbents were studied by batch procedure. The prepared copolymer gel with 4‐VP as monomer and Cu(II)–4‐(2‐pyridylazo)resorcinol complex has higher capacity and selectivity toward Cu(II) than the copolymer gels prepared using the mixture of methacrylic acid and 4‐VP. This new sorbent can be used as an effective SPE material for the highly selective preconcentration and separation of Cu(II) in sea water samples. It shows high mechanical and chemical stability. 相似文献
12.
Mohammad Hossein Mashhadizadeh Mahnaz Pesteh Mahzad Talakesh Iran Sheikhshoaie Mohammad Mazloum Ardakani Mohammad Ali Karimi 《Spectrochimica Acta Part B: Atomic Spectroscopy》2008
A simple, selective and reliable method for rapid extraction and determination of trace amounts of Cu (II) ions from aqueous samples using octadecyl-bonded silica membrane disks modified with bis-(3-methoxy salicylaldehyde)-1,6-diaminohexane and flame atomic absorption spectrometry (FAAS) is presented. Extraction efficiency, the influence of pH, flow rates, amount of ligand, and type and least amount of eluant were investigated. The linear dynamic range of the proposed method for Cu (II) ions was found in a wide concentration range of 1.0 (± 0.2)–150 (± 2) μg l− 1. The detection limit and preconcentration factor of this method were found 30.0 (± 0.7) ng l− 1 and 100 respectively. The reproducibility of the procedure is at the most 2.0%. The effects of various cationic interferences on the percent recovery of copper ion were studied. The method was used to the recovery of copper ion from different synthetic, alloys and biological samples. 相似文献
13.
Manuela Leticia Kim 《Talanta》2009,79(3):940-930
In this work, a non-chromatographic procedure for the on-line determination of ultratraces of V(V) and V(IV) is presented. The method involves a solid phase extraction-flow injection system coupled to electrothermal atomic absorption spectrometry (SPE-FI-ETAAS). The system holds two microcolumns (MC) set in parallel and filled with lab-made mesoporous silica functionalized with 3-aminopropyltriethoxy silane (APS) and mesoporous silica MCM-41, respectively. The pre-concentration of V(V) is performed by sorption onto the first MC (C1) filled with APS at pH 3, whilst that of V(IV) is performed by sorption onto the second column (C2) filled with mesoporous silica MCM-41 at pH 5. Aqueous samples containing both analytes are loaded and, after pre-concentration (pre-concentration factor PCF = 10, sorption flow rate = 1 mL min−1, sorption time = 10 min), they are eluted in separate vessels with hydroxylammonium chloride (HC) 0.1 mol L−1 in HCl 0.5 mol L−1 (elution volume = 1 mL, elution flow rate = 0.5 mL min−1). Afterwards, both analytes are determined through ETAAS with graphite furnace. Under optimized conditions, the main analytical figures of merit for V(V) and V(IV) are, respectively: detection limits (3 s): 0.5 and 0.6 μg L−1, linear range: 2-100 μg L−1 (both analytes), sensitivity: 0.015 and 0.013 μg−1 L and sample throughput: 6 h−1 (both analytes). Recoveries of both species were assayed in different water samples. Validation was performed through certified reference materials for ultratraces of total vanadium in river water. 相似文献
14.
Magnetic solid‐phase extraction of brominated flame retardants from environmental waters with graphene‐doped Fe3O4 nanocomposites 下载免费PDF全文
Jing Yang Jun‐qin Qiao Shi‐hai Cui Jia‐yuan Li Jin‐jin Zhu He‐xing Yin Cheng‐yan Zhan Hong‐zhen Lian 《Journal of separation science》2015,38(11):1969-1976
Graphene‐doped Fe3O4 nanocomposites were prepared by a solvothermal reaction of an iron source with graphene. The nanocomposites were characterized by transmission electron microscopy, atomic force microscopy, X‐ray diffraction, superconducting quantum interference, Raman spectroscopy, Fourier transform infrared spectroscopy, and X‐ray photoelectron spectroscopy. This nanomaterial has been used as a magnetic solid‐phase extraction sorbent to extract trace brominated flame retardants from environmental waters. Various extraction parameters were optimized including dosage and reusability of the nanocomposites, and pH of sample matrix. The reliability of the magnetic solid‐phase extraction protocol based on graphene‐doped Fe3O4 nanocomposites was evaluated by investigating the recoveries of 2,4,6‐tribromophenol, tetrabromobisphenol A, 4‐bromodiphenyl ether, and 4,4?‐dibromodiphenyl ether in water samples. Good recoveries (85.0–105.0%) were achieved with the relative standard deviation ranging from 1.1–7.1%. Moreover, it is speculated from characterization and magnetic solid‐phase extraction experiment that there is not only π–π stacking but also possible hydrophobic interaction between the graphene‐doped Fe3O4 nanocomposites and analytes. 相似文献
15.
Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L−1 and 8.8 μg L−1, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. 相似文献
16.
A simple solid phase extraction procedure for speciation of selenium(IV) and selenium(VI) in environmental samples has been proposed prior to graphite furnace atomic absorption spectrometry. The method is based on the solid phase extraction of the selenium(IV)-ammonium pyrrolidine dithiocarbamate (APDC) chelate on the Diaion HP-2MG. After reduction of Se(VI) by heating the samples in the microwave oven with 4 mol l−1 HCl, the system was applied to the total selenium. Se(VI) was calculated as the difference between the total selenium content and Se(IV) content. The experimental parameters, pH, amounts of reagents, eluent type and sample volume were optimized. The recoveries of analytes were found greater than 95%. No appreciable matrix effects were observed. The adsorption capacity of sorbent was 5.20 mg g−1 Se (IV). The detection limit of Se (IV) (3sigma, n = 11) is 0.010 μg l−1. The preconcentration factor for the presented system was 100. The proposed method was applied to the speciation of selenium(IV), selenium(VI) and determination of total selenium in natural waters and microwave digested soil, garlic, onion, rice, wheat and hazelnut samples harvested various locations in Turkey with satisfactory results. In order to verify the accuracy of the method, certified reference materials (NIST SRM 2711 Montana Soil, NIST SRM 1568a Rice Flour and NIST SRM 8418 Wheat Gluten) were analyzed and the results obtained were in good agreement with the certified values. The relative errors and relative standard deviations were below 6 and 10%, respectively. 相似文献
17.
Elahe Kazemi Shayessteh Dadfarnia Fatemeh Izadi 《International journal of environmental analytical chemistry》2017,97(11):1080-1093
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples. 相似文献
18.
Mohammad Ali Karimi Abdolhamid Hatefi-Mehrjardi Sayed Zia Mohammadi Alireza Mohadesi Mohammad Mazloum-Ardakani Asghar Askarpour Kabir 《International journal of environmental analytical chemistry》2013,93(12):1325-1340
A new, simple, fast and reliable solid-phase extraction (SPE) method has been developed to separation/preconcentration of trace amounts of silver ion from environmental water samples using dithizone/sodium dodecyl sulfate immobilized on alumina-coated magnetite nanoparticles (DTZ/SDS-ACMNPs) and its determination by flame atomic absorption spectrometry. The coating of alumina on Fe3O4 NPs not only avoids the dissolving of Fe3O4 NPs in acidic solution, but also extends their application without sacrificing their unique magnetization characteristics. This method avoided the time-consuming column-passing process of loading large volume samples in traditional SPE through the rapid isolation of DTZ/SDS-ACMNPs with an adscititious magnet. Optimal experimental conditions including amount of DTZ/SDS, pH value, standing time, sample volume, type, volume and concentration of eluent and co-existing ions have been studied and established. Under the optimal experimental conditions, the detection limit for Ag(I) with enrichment factors of 100 was found to be 0.52?ng?mL?1 and its relative standard deviations (RSD) was 3.4% (n?=?10, C?=?5.0?µg?mL?1). The linear range of calibration curve for Ag(I) was 2–5000?ng?mL?1 with a correlation coefficient of 0.9991. The proposed method was successfully applied to the determination of target analyte in different water and wastewater samples. The validity of the method has been checked by applying it to study the recovery of silver ion in spiked water and wastewater samples. 相似文献
19.
Xiandi Zhu Songlin Zhao Hua Yan Deman Han 《International journal of environmental analytical chemistry》2013,93(10):689-699
In this work, bamboo charcoal (BC) was used as a sorbent for on-line solid phase extraction (SPE) coupling with flame atomic absorption spectrometry (AAS) for trace copper and zinc determination in environmental and biological samples. Under the optimum pH of 5.5 (for Zn) and 7.0 (for Cu), trace copper and zinc were effectively adsorbed on the microcolumn and the retained cations were efficiently eluted with HCl or HNO3 with an appropriate concentration and flow rate for on-line AAS determination. With a sample loading time of 60 s at a sample flow rate of 7.6 mL min?1, the enhancement factors of 39 (for Cu) and 30 (for Zn) and detection limits (3σ) of 0.60 µg L?1 (for Cu) and 0.36 µg L?1 (for Zn), respectively, were achieved. The sample throughput was 45 h?1. At the level of 20 µg L?1of Cu(II) and Zn(II), the precision (RSD, n?=?11) were found to be 0.26% and 1.6%, respectively. The proposed method has been successfully applied to the determination of copper and zinc in environmental and biological samples. 相似文献
20.
The present article reports the application of Thiosemicarbazide‐modified multiwalled carbon nanotubes (MWCNTs‐TSC) as a new, easily prepared selective and stable solid sorbent for the preconcentration of trace Co(II), Cd(II), Cu(II) and Zn(II) ions in aqueous solution prior to the determination by flame atomic absorption spectrometry. The studied metal ions can be adsorbed quantitatively on MMWNTs at pH 5.0 and then eluted completely with HNO3 (1.5 mol L?1) prior to their determination by flame atomic absorption spectrometry. The separation/preconcentration conditions of analytes were investigated, including the pH, the sample flow rate and volume, the elution condition and the interfering ions. The maximum adsorption capacity of the adsorbent at optimum conditions were found to be 32.5, 27.3, 44.5 and 34.1 mg g?1 for Co(II), Cd(II), Cu(II) and Zn(II), and the detection limits of the method were found to be 0.28, 0.13, 0.21 and 0.17 μg L?1, respectively. The proposed method was successfully applied for extraction and determination of the analytes in well water, sea water, wastewater, soil, and blood samples. 相似文献