首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

2.
微波消解-GFAAS测定浅水湖泊底泥中重金属元素   总被引:1,自引:0,他引:1  
探讨了采用微波消解作为底泥样品的前处理方法,运用石墨炉原子吸收法测定浅水湖泊底泥中Cu,Pb,Zn,Cd,Cr含量的实验条件.方法的RSD为2.0%~4.1%,平均回收率为97.4%~101.5%,Cu,Pb,Zn,Cd,Cr的检出限分别为0.4,5,2.8,0.25,2.5ng.该法适合于浅水湖泊底泥中重金属含量的测定.  相似文献   

3.
This paper reports a liquid chromatographic/electrospray ionization mass spectrometric (LC/ESI-MS) method for profiling a wide range of structurally different sulfoconjugated compounds in urine and its application to the characterization of biomarkers for heavy metal toxicity in rat urine. Sulfoconjugates were first isolated by solid-phase extraction and the LC separation was performed on a reversed-phase column. Sulfoconjugates were detected in a triple-quadrupole mass spectrometer by simultaneously monitoring constant losses of 80 u (or 80 Th for doubly charged ions), precursors of m/z 80 (SO(3) (-*)) and precursors of m/z 97 (HSO4-). The ESI-MS detection conditions were optimized on dehydroepiandrosterone sulfate and estradiol sulfate and tested on other sulfoconjugates. The analysis of urine samples from humans and rats by using the developed method allowed the detection of about 15 peaks in each mode of detection. It was then applied to the investigation of heavy metal toxicity in rats. Comparative analysis of the chromatographic fingerprints of urine from control and uranium- and cadmium-treated rats showed several variations in the chromatographic pattern of the sulfoconjugates. Diagnostic m/z ratios were confirmed by analyzing individual urine samples and one of the observed variations seemed to be specific to uranium toxicity. The ion responsible for this variation has been identified as 4-ethylphenol sulfate by comparison of its chromatographic retention time and collision-induced dissociation mass spectra (MS(2) and MS(3) performed on a quadrupole ion trap instrument) with those of the synthesized compound.  相似文献   

4.
Aqueous Pb(II) adsorption on pine bark (Pinus Radiata D.Don), an inexpensive and sustainable natural sorbent material, has been evaluated and the mechanism of metal retention characterized by scanning electron microscopy (SEM), diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and X‐ray photoelectron spectroscopy (XPS). Bark pulp densities >1.5 g l?1 achieve near 100% Pb(II) removal from aqueous solutions containing 100 mg l?1 Pb(II). Adsorption rates increased with pulp density, although adsorption capacity diminished at high densities because of blockage of adsorption sites. The effects of washing and sulfuric acid activation were assessed and found to be less important than in previous metal sorption studies. Pb(II) sorption takes place mainly at the lignocellulosic C―O groups, with adsorption at phenolic sites appearing to be most significant. © 2016 The Authors. Surface and Interface Analysis published by John Wiley & Sons, Ltd.  相似文献   

5.
Atomic spectroscopy is the most popular approach to determine the presence of heavy metals in the environment. Heavy metals are potentially toxic and have various negative effects on many living organisms, including humans. With the rapid increase in the variety of industries and human activities, large amounts of heavy metals are released into the atmosphere, water, and soil. Heavy metal analysis of environmental samples is very important for determining the exposure limits. Environmental samples are highly complex matrices, and various sample preparation techniques have been developed for the extraction of heavy metals from them, including magnetic solid-phase extraction (MSPE). The use of MSPE in heavy metal analysis has recently gained significant attention owing to a number of advantages. MSPE technique overcomes main issues such as phase separation, handling, and column packing. The use of magnetic adsorbents in sample preparation has grown over the past few years, making MSPE a promising technique for sample preparation. The objective of this review article is to provide the latest applications of MSPE coupled with atomic spectroscopy for heavy metal determination in environmental samples. In addition, new magnetic adsorbents and their analytical merits are emphasized.  相似文献   

6.
A graft copolymerization was performed using free radical initiating process to prepare the poly(methyl acrylate) grafted copolymer from the tapioca cellulose. The desired material is poly(hydroxamic acid) ligand, which is synthesized from poly(methyl acrylate) grafted cellulose using hydroximation reaction. The tapioca cellulose, grafted cellulose and poly(hydroxamic acid) ligand were characterized by Infrared Spectroscopy and Field Emission Scanning Electron Microscope. The adsorption capacity with copper was found to be good, 210 mg g?1 with a faster adsorption rate (t1/2 = 10.5 min). The adsorption capacities for other heavy metal ions were also found to be strong such as Fe3+, Cr3+, Co3+ and Ni2+ were 191, 182, 202 and 173 mg g?1, respectively at pH 6. To predict the adsorption behavior, the heavy metal ions sorption onto ligand were well-fitted with the Langmuir isotherm model (R2 > 0.99), which suggest that the cellulose-based adsorbent i.e., poly(hydroxamic acid) ligand surface is homogenous and monolayer. The reusability was checked by the sorption/desorption process for six cycles and the sorption and extraction efficiency in each cycle was determined. This new adsorbent can be reused in many cycles without any significant loss in its original removal performances.  相似文献   

7.
A density functional and ab initio theory investigation on M@B9 and M@B10 molecular wheels containing planar nona-and deca-coordinate heavy group 11, 12 and 13 metals (M=Ag, Au, Cd, Hg, In, Ti) has been performed. These unusual clusters all prove to be true minima on the potential energy surfaces of the systems and σ+π double aromatic in nature. The first two vertical one-electron detachment energies of M@B-10 (M=Ag, Au) anions and first two ionization potentials of M@B9 (M=Ag, Au) and M@B10 (M=Cd, Hg) neut...  相似文献   

8.
Wang J  Nakazato T  Sakanishi K  Yamada O  Tao H  Saito I 《Talanta》2006,68(5):1584-1590
A microwave digestion method with HNO3 alone was conducted at a temperature as high as 250 °C for determination of 19 trace elements (Li, Be, V, Cr, Mn, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Cd, Cs, Ba, Hg, and Pb) in coal jointly by inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), and flow injection ICP-MS (FI-ICP-MS). The validity of determination was assessed by using three standard coals, SRM 1632c, BCR 180, and SARM 19. It was found that the high-temperature digestion led to an extensive decomposition of the organic matrix and clay in coal, and no dissolved and solid carbon remained in the final solution after evaporation. Good recoveries were observed for all trace elements in three coals, with the exception of V, Rb, and Cs in high-ash SARM 19. Additionally, FI-ICP-MS combined with the present digestion without evaporation pretreatment was proved to be a rapid and efficient approach for determination of ultra-trace elements such as Se, Cd, and Hg in coal.  相似文献   

9.
10.
The crystal structures of the first‐row transition‐metal series of tris(ethylenediamine‐κ2N ,N ′)metal(II) diacetate, [M (C2H8N2)3](CH3CO2)2, with M = Mn, Fe, Co, Ni, Cu, and Zn, are reported. The complexes are all isostructural, crystallizing in a centrosymmetric triclinic cell and possessing an asymmetric unit composed of one [M (en)3]2+ cation and two symmetrically independent acetate anions. In the unit cell, the two complex cations are inversion‐generated enantiomers, possessing the energetically favoured Δ(λλλ) and Λ(δδδ) configurations. The complex cations and acetate anions combine through a series of N—H…O hydrogen bonds to generate a three‐dimensional network in the crystals. The other notable feature of the series is a significant Jahn–Teller distortion for the d 9 Cu2+ complex.  相似文献   

11.
12.
13.
14.
田红玉  孙宝国 《化学通报》2004,67(12):934-937
介绍了一种简单的制备(1R,3S)-3-氨基1环己烷羧酸的方法。以环己烷-1,3-二羧酸的顺反混合物为原料。经过关环得顺式的酸酐,然后酯化,在脂肪酶AY-30的作用下进行去对称性水解。得光学活性的环己烷-1,3-二羧酸的单乙酯产物,经过改进的Curtis重排反应后,羧酸基团转变为氨基。然后经过酯水解、去保护基团,得到光学纯的(1R,3S)-3-氨基-1-环己烷羧酸。  相似文献   

15.
Three‐dimensional (3D) paper‐based microfluidics, which is featured with high performance and speedy determination, promise to carry out multistep sample pretreatment and orderly chemical reaction, which have been used for medical diagnosis, cell culture, environment determination, and so on with broad market prospect. However, there are some drawbacks in the existing fabrication methods for 3D paper‐based microfluidics, such as, cumbersome and time‐consuming device assembly; expensive and difficult process for manufacture; contamination caused by organic reagents from their fabrication process. Here, we present a simple printing–bookbinding method for mass fabricating 3D paper‐based microfluidics. This approach involves two main steps: (i) wax‐printing, (ii) bookbinding. We tested the delivery capability, diffusion rate, homogeneity and demonstrated the applicability of the device to chemical analysis by nitrite colorimetric assays. The described method is rapid (<30 s), cheap, easy to manipulate, and compatible with the flat stitching method that is common in a print house, making itself an ideal scheme for large‐scale production of 3D paper‐based microfluidics.  相似文献   

16.
XAD copolymer resins may be functionalized with heavy metal ion-selective ligands either by covalent linkage to the polymer backbone or by impregnation. These resins may be tailored to be specific for certain heavy metals by adjusting the adsorption and elution parameters, thereby enabling simple and cost-effective spectrophotometric and flame atomic absorption spectrometry (FAAS) determinations of these metals without requiring the more sophisticated coupled instrumental techniques. For the synthesis of o-aminobenzoic acid (ABA)-immobilized XAD-4 copolymer resin that is expected to preconcentrate a number of transition and heavy metals, the azo-linkage method was chosen. For this purpose the copolymer was nitrated, reduced to the corresponding amine, converted to the diazonium salt with nitrite, and reacted with o-aminobenzoic acid to produce the XAD-ABA sorbent. This sorbent was capable of preconcentrating Pb(II), Cd(II), Ni(II), Co(II) and Zn(II) from weakly acidic or neutral aqueous solution. The retained metals were eluted with 1.0 M HNO3 from the resin column, and were subsequently determinated with by flame atomic absorption spectrometry. The developed resin preconcentration and determination method was successfully applied to the analysis of a synthetic metal mixture solution, a certified reference material (CRM) of coal sample, and brackish lake water.  相似文献   

17.
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra- and inter-laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.  相似文献   

18.
19.
Zen JM  Hsu CT 《Talanta》1998,46(6):1363-1369
A square-wave voltammetric method together with Nafion®-coated carbon paste electrodes were used for the selective determination of uric acid in the presence of a high concentration of ascorbic acid. Since the oxidation potential of uric acid is about 200 mV more positive than that of ascorbic acid at the Nafion®-coated carbon paste electrode, the selectivity can be greatly improved simply by applying an electrolysis potential of +0.4 V vs. Ag/AgCl where only ascorbic acid is oxidised. The acceptable tolerance of ascorbic acid concentration for the determination of uric acid is as high as 1.5 mM. With 30 s of electrolysis time, a linear calibration curve is obtained over the 0–50 μM range in 0.05 M citrate buffer solution, pH 4.0, with slope (μA/μM) and correlation coefficient of 0.34 and 0.9984, respectively. The detection limit (3σ) is 0.25 μM. The practical analytical utility is illustrated by selective measurements of uric acid in human urine without any preliminary treatment.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号