首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
An ion chromatography system employing a low-cost three-dimensional printed absorbance detector for indirect ultraviolet detection towards portable phosphate analysis of environmental and industrial waters has been developed. The optical detection cell was fabricated using stereolithography three-dimensional printing of nanocomposite material. Chromatographic analysis and detection of phosphate were carried out using a CS5A 4 × 250 mm analytical column with indirect ultraviolet detection using a 255 nm light-emitting diode. Isocratic elution using a 0.6 mM potassium phthalate eluent combined with 1.44 mM sodium bicarbonate was employed at a flow rate of 0.75 mL/min. A linear calibration range of 0.5 to 30 mg/L PO43− applicable to environmental and wastewater analysis was achieved. For retention time and peak area repeatability, relative standard deviation values were 0.68 and 4.09%, respectively. Environmental and wastewater samples were analyzed with the optimized ion chromatography platform and the results were compared to values obtained by an accredited ion chromatograph. For the analysis of environmental samples, relative errors of <14 % were achieved. Recovery analysis was also carried out on both freshwater and wastewater samples and recovery results were within the acceptable range for water analysis using standard ion chromatography methods.  相似文献   

2.
The potential of microwave-assisted derivatization techniques in systematic toxicological analysis using gas chromatography coupled with mass spectrometry (GC–MS) was evaluated. Special emphasis was placed on the use of dedicated microwave reactors incorporating online temperature and pressure control. The use of such equipment allowed a detailed analysis of several microwave-assisted derivatization protocols comparing the efficiency of microwave and conventional heating methods utilizing a combination of GC–MS and liquid chromatography coupled with mass detection (LC–MS and LC–MS/MS) techniques. These studies revealed that for standard derivatization protocols such as acetylation (exemplified for codeine and morphine), pentafluoropropionylation (for 6-monoacetylmorphine) and trimethylsilylation (for Δ9-tetrahydrocannabinol) a reaction time of 5 min at 100 °C in a microwave reactor was sufficient to allow for an effective derivatization. Control experiments using standard operating procedures (30 min at 60 °C conventional heating) indicated that the faster derivatization under microwave irradiation is a consequence of the higher reaction temperatures that can rapidly be attained in a sealed vessel and the more efficient heat transfer to the reaction mixture applying direct in core microwave dielectric heating. The results suggest that microwave derivatization procedures can significantly reduce the overall analysis time and increase sample throughput for GC–MS-based analytical methods.  相似文献   

3.
Summary Reversed-phase liquid chromatography with fluorescence detection (RPLC-FD) and with electrospray ionization (ESI) tandem mass spectrometric detection (RPLC-ESI-MS-MS), both coupled with automated solid-phase sample extraction, have been used for trace enrichment and analysis of octylphenol and nonylphenol (NP) in municipal wastewater. Quality data calculated for the methods were detection limits (LOD), quantitation limits, linearity, precision, and accuracy. For LC-ESI-MS-MS theLOD were below 0.08 μg L−1. Unequivocal detection of NP in wastewater samples was achieved by use of LC-ESI-MS and LC-ESI-MS-MS. In particular, application of the LC methods to wastewater samples revealed that the selectivity of LC-MS-MS was more than that of LC-FD for qualitative and quantitative analysis of complex matrices.  相似文献   

4.
Reversed-phase high-performance liquid chromatography (RPLC) of 17 amino acids and ammonium ion, pre-derivatized with o-phthalaldehyde and ethanethiol, has been investigated using on-line recycled mobile phase. The mobile phase was sodium phosphate buffer, pH 7.2, containing acetonitrile and 1 mM potassium peroxodisulfate. Fifty consecutive separations on an octadecyl silica gel column, kept at 35 °C, could be achieved by use of 50 mL mobile phase, at a flow rate of 2.0 mL min−1, without significant changes of peak height and retention times of valine (Val), methionine (Met), and isoleucine (Ileu). RSD of peak heights and retention times were, respectively, 7.6 and 1.1% for Val, 9.6 and 0.9% for Met, and 4.9 and 0.8% for Ileu. The volume of mobile phase used was only one sixtieth that used for conventional RPLC. Analysis of Val, Met, and Ileu in beverages was achieved by use of this method. The results were in agreement with those obtained by conventional RPLC. This method could be also used for analysis of the other amino acids.  相似文献   

5.
A simple, reliable, and highly sensitive method for the simultaneous determination of aflatoxin B1, B2, G1, G2 in Fructus Bruceae was developed using high‐performance liquid chromatography coupled to online postcolumn photochemical derivatization and fluorescence detection. Aflatoxins were first extracted by a methanol/water mixture and then cleaned up with an AflaTest? immunoaffinity column. Different clean‐up and derivatization methods were compared and optimized. The established method was extensively validated to show satisfactory performance of linearity (R2 ≥ 0.9997), recovery (74.3–100.8%), and precision (RSDs ≤ 2.8%) for the investigated aflatoxins. This proposed method was also applied to 11 F. Bruceae samples and the results showed that 10 out of 11 were contaminated with aflatoxins ranging from 0.26 to 27.52 μg/kg and the occurrence of aflatoxin B1, the most toxic one, was as high as 91% in all the samples, highlighting the severe contamination and the necessity to set legal limits for aflatoxins in F. Bruceae.  相似文献   

6.
A fast and sensitive method was developed for the determination of the absolute configuration of selenomethionine. The enantiomers of selenomethionine were converted into diastereomeric isoindole derivatives by reaction with o-phthaldialdehyde and N-isobutyryl-l-cysteine. This easy-to-handle reaction proceeds quantitatively in a few minutes at room temperature. Separation and detection of the diastereomers was achieved by reversed-phase high-performance liquid chromatography–inductively coupled plasma-mass spectrometry (RP-HPLC/ICP-MS) using a conventional C18 reversed-phase column. Detection limits of about 4 µg L–1 were obtained. The method was applied to the determination of the configuration of selenomethionine extracted from antarctic krill, which turned out to possess the l-configuration.  相似文献   

7.
The simultaneous determination of Tyr, catecholamines and their metabolites in one whole metabolic pathway using high performance liquid chromatography coupled with fluorescence detection (HPLC–FLD) based on pre-column derivatization has been achieved successfully. 1,3,5,7-Tetramethyl-8-(N-hydroxysuccinimidyl butyric ester)-difluoroboradiaza-s-indacene (TMBB-Su), a highly reactive fluorescent reagent synthesized in our previous work, was used for the labeling of tyrosine (Tyr), l-3,4-dihydroxyphenylalanine (l-DOPA), dopamine (DA), norepinephrine (NE), epinephrine (E) and metanephrine (MN). Derivatization conditions including reagent concentration, buffer, reaction temperature and reaction time were also investigated to improve the derivatization efficiency and thus the sensitivity of the detection. The separation of the derivatives was obtained on C18 column with the mobile phase of 20 mM pH 3.5 citric acid (H3Cit)–sodium hydrogen phosphate (Na2HPO4) buffer and methanol. Good linearities with correlation coefficients square (R2) greater than 0.998 in the corresponding concentration ranges were observed and the detection limits (S/N = 3) were found in the range from 0.10 to 0.40 nM (l-DOPA: 1.45 nM). The proposed method has been applied to the detection of catecholamines and related compounds in mice liver and brain samples without tedious extraction or purification procedure, which exhibits excellent selectivity and sensitivity in the analysis of complex samples. This work provides an alternative approach in the metabolic research of catecholamines and is helpful for the study of catecholamine metabolism.  相似文献   

8.
A new method for the determination of baicalin in Scutellariae Radix extract and its preparations by high performance liquid chromatography (HPLC) coupling with flow injection chemiluminescence detection (FIA‐CL) has been developed. The method was based on the chemiluminescence reaction of potassium permanganate with baicalin in nitric acid medium; the CL intensity can be enhanced by formaldehyde. In this study, the conditions of chemiluminescence and chromatography were examined, and the schematic diagram of the HPLC‐FIA‐CL analyzer was optimized. The analytes were separated on Hypersil RP‐C18 columns (100 × 4.6 mm, I.D., 5 μm) by equality elution with 47:53 (v/v) methanol‐0.3% phosphoric acid as a mobile phase at a flow rate of 0.8 mL·min?1 and a column temperature of 40 °C. Under the optimum condition, the CL intensity was proportional to the concentration of baicalin over the range of 4.10 × 10?7 ? 6.15 × 10?5mol·L?1. The limit of detection (S/N = 3) was 2.79 × 10?7mol·L?1 with the relative standard deviation 2.5% (Cs = 6.15 × 10?6 mol·L?1, n = 5). The method has been applied to the determination of baicalin in Scutellariae Radix extract and its preparations, and satisfactory results were obtained.  相似文献   

9.
Ultra‐performance convergence chromatography is an environmentally friendly analytical technique that employs dramatically reduced amounts of organic solvents compared to conventional chromatographic methods. In this study, a rapid, sensitive, and environmentally friendly method based on ultra‐performance convergence chromatography was developed for the quantification of four major chromones present in the roots of Saposhnikovia divaricata (Turcz.) Schischk. Using this method, the analysis time was significantly shortened compared to conventional high‐performance liquid chromatography techniques. In addition, the influence of cosolvent type, cosolvent ratio, column temperature, system pressure, and flow rate on the peak resolution was investigated. The proposed method was validated in terms of its limits of detection, limits of quantitation, linearity, precision, and accuracy. More specifically, the limits of detection of the four chromones ranged from 0.006 to 0.033 μg/mL, while the limits of quantitation ranged from 0.019 to 0.101 μg/mL. Our method also exhibited a good regression (r2 > 0.999), excellent precision (RSD < 0.60%), and acceptable recoveries (99.48–102.89%). Finally, the quantities of these four chromones present in 20 commercial samples from Korea and China were successfully evaluated using the developed method, indicating that the proposed method is suitable for the rapid and accurate quality control of Saposhnikovia divaricata.  相似文献   

10.
A simple and sensitive liquid chromatographic method has been developed for the determination of low molecular weight aliphatic amines after their pre-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). Derivatization conditions, including the NDA concentration, reaction pH and reaction time have been investigated for method optimization. The chromatographic separation of five amines was performed on ABZ PLUS column using mobile phase of methanol-water (80:20, v/v) at a flow rate of 0.2 mL min−1. The detection was carried out with a 6 mm glassy carbon electrode at the applied potential of 0.7 V versus Ag/AgCl reference electrode. The detection limits were between 23.3 and 34.4 nmol L−1 of amines with a sample injection volume of 2 μL. The present method was applied for the determination of aliphatic amines in lake water. The recovery ranged 52.2-127.9%. The RSD in analytes retention time was less than 0.3% and 2.4% for intra- and inter-day analyses, respectively. The RSD in peak area was below 5.8% for both intra-day and inter-day analyses. The total analysis was completed within 20 min.  相似文献   

11.
Chen L  Ding L  Yu A  Yang R  Wang X  Li J  Jin H  Zhang H 《Analytica chimica acta》2007,596(1):164-170
This paper describes a new method for the determination of total flavonoids in Platycladus orientalis (L.) Franco. The method was based on dynamic microwave-assisted extraction (DMAE) coupled with on-line derivatization and ultraviolet-visible (UV-vis) detection. The influence of the experimental conditions was tested. Maximum extraction yield was achieved using 80% aqueous methanol of extraction solvent; 80 W of microwave output power; 5 min of extraction time; 1.0 mL min−1 of extraction solvent flow rate. The derivatization reaction between aluminium chloride and flavonoid is one of the most sensitive and selective reactions for total flavonoids determination. The optimized derivatization conditions are as follows: derivatization reagent 1.5% aluminium chloride methanol solution; reaction coil length 100 cm; derivatization reagent flow rate 1.5 mL min−1. The detection and quantification limits obtained are 0.28 and 0.92 mg g−1, respectively. The intra-day and inter-day precisions (R.S.D.) obtained are 1.5% and 4.6%, respectively. Mean recovery is 98.5%. This method was successfully applied to the determination of total flavonoids in P. orientalis (L.) Franco and compared with heat reflux extraction. The results showed that the higher extraction yield of total flavonoids was obtained by DMAE with shorter extraction time (5 min) and small quantity of extraction solvent (5 mL).  相似文献   

12.
A new reversed-phase ion-pair high-performance liquid chromatographic (HPLC) method has been developed for the determination of the following bisphosphonic acids: alendronic acid (ALEN), etidronic acid (ETID), ibandronic acid (IBAN) and risedronic acid (RISE). Separation was achieved on a C18 column using a mixture of 50 mmol L−1 borate buffer pH 9.0 containing 0.25 mmol L−1 tetrabutylammonium chloride and 0.5 mmol L−1 EDTA and acetonitrile (97:3) as the mobile phase. The sensitive detection of the above bisphosphonic acids was based on their oxidation to orthophosphate by the on-line peroxydisulfate-assisted photolysis followed by post-column reaction with molybdate to yield phosphomolybdate. This subsequently reacted with thiamine to generate thiochrome and, finally, the fluorescence of thiochrome was measured at 440 nm with excitation at 375 nm. The developed method is precise with a mean relative standard deviation of 1.3%, sensitive (with a detection limit at the nmol L−1 level), accurate, specific, rapid (analysis time approximately 13 min) and inexpensive because to the low cost of the reagents. The assay was applied to the analysis of the four bisphosphonic acids in commercial dosage formulations, in which the excipients did not interfere with the determination. The method was also applied to the determination of etidronate, risedronate and ibandronate in human urine. Sample preparation involves precipitation of the analytes from urine along with endogenous phosphates such as calcium salts by addition of calcium chloride at alkaline pH and dissolution of the precipitate in 0.05 mol L−1 ethylene glycol-bis(β-aminoethyl ether)-N,N,N′,N′-tetraacetic acid.  相似文献   

13.
A method based on direct immersion solid‐phase microextraction (DI‐SPME) coupled with high performance liquid chromatography combined with post‐column photochemically induced fluorimetry derivatization and fluorescence detection (HPLC‐PIF‐FD) was developed to extract three pyrethroid insecticides, i.e. cyfluthrin, cypermethrin, and flumethrin from water samples. A sol‐gel based coating fiber using 3‐(trimethoxysilyl propyl) amine as precursor was prepared and used for the extraction of the pyrethroids from groundwater samples. A post‐column photochemical reactor was designed and constructed for the derivatization of these environmentally important pollutants to increase their fluorescence sensitivity and determination in HPLC. The parameters affecting extraction process (extraction time and temperature, pH, salt addition, and co‐solvent) and desorption step (solvent, desorption time, and temperature) of the analytes from the sol‐gel‐based fiber, along with photochemical reaction conditions were investigated. The developed method proved to be relatively rapid, simple, and easy and offers high sensitivity and reproducibility. Linear dynamic ranges (LDR) for these insecticides were ranged between 0.25 to 50 μg/L. The regression coefficients were satisfactory (R2 > 0.984) for these pyrethroids. The limits of detection and limits of quantification varied between 0.09 and 0.35 μg/L and 0.25 and 1.00 μg/L, respectively. Relative standard deviation RSDs values varied between 4.41% and 6.20%. Relative recoveries obtained from analysis of Jajroud river water sample ranged between 94% and 104%.  相似文献   

14.
Trans-fatty acids are unsaturated fatty acids that are considered to have health risks. 1,3,5,7-Tetramethyl-8-butyrethylenediamine-difluoroboradiaza-s-indacene is a highly sensitive fluorescent labeling reagent for carboxylic acids developed by our lab. In this study, using this precolumn fluorescent derivatization reagent, a rapid and accurate high-performance liquid chromatography with fluorescence detection method was developed for the determination of two trans-fatty acids in food samples. Under the optimized derivative conditions, two trans-fatty acids were tagged with the fluorescent labeling reagent in the presence of 1-ethyl-3-(3-dimethyl-aminopropyl) carbodiimide at 25°C for 30 min. Then, the baseline separation of trans- and cis-fatty acids and their saturated fatty acid with similar structures was achieved with less interference using a reversed-phased C18 column with isocratic elution in 14 min. With fluorescence detection at λexem = 490 /510 nm, the linear range of the TFAs was 1.0-200 nM with low detection limits in the range of 0.1–0.2 nM (signal-to-noise ratio = 3). In addition, the proposed approach was successfully applied for the detection of trans-fatty acids in food samples, and the recoveries using this method ranged from 96.02 to 109.22% with low relative standard deviations of 1.2–4.3% (= 6).  相似文献   

15.
Monomethylarginine, asymmetric dimethylarginine and symmetric dimethylarginine were separated on a Wakopak Combi ODS with an acetonitrile–100 mm potassium phosphate buffer (pH 7.0; 1:1, v/v). Dimethylarginines were derived from o‐phthalaldehyde for the fluorescence detector and from 6‐ferrocenyl‐1‐hexanethiol for the electrochemical detector. The detection limits of the dimethylarginines in spiked plasma were 0.3–0.5 pmol by electrochemical detection and 1–2 pmol by fluorescence detection. The detection limits were improved over 30 times by electrochemical detection and 10 times by fluorescence detection compared with previous reports. In previous derivatization liquid chromatography, the reaction solutions, o‐phthalaldehyde, 2‐mercaptethanol and dimethylarginines were unstable and required quick derivatization at 4°C. By our proposed pre‐column methods, the dimethylarginines were derivatized at room temperature and the fluorescent products were stable for 6 h. The manipulation performance was greatly advanced compared with previous LC reports. This is the first report on stable and sensitive dimethylarginines by dual detection. The selectivity was also improved by dual detection. The proposed method was applied to preliminary monitoring of dimethylargines in plasma and urine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg2+, Ca2+, and Sr2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV‐absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg2+, Ca2+, and Sr2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg2+, Ca2+, and Sr2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S /N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded.  相似文献   

17.
A continuous wave, argon ion laser-induced fluorescence detector was designed for use with conventional high performance liquid chromatography. Palmitic acid was selected as a model analyte to evaluate the performance of the detector. Using the intense 488.0 nm emission line, a concentration detection limit of 7.5 × 10–10 M (38 femtomoles on-column) was established for palmitic acid at a signal to noise ratio of three. The linear dynamic range extended over two orders of magnitude with a correlation coefficient of 0.9998. The contribution of scattered radiation to the analytical signal was minimal. The concentration detection limit achieved with the constructed laser fluorometer was superior to other reports for fatty acids.  相似文献   

18.
A high-performance liquid chromatographic method with evaporative light-scattering detection (ELSD) has been developed for analysis of spectinomycin and related impurities. Separation of spectinomycin from structurally related impurities was achieved on a C18 column. The optimized mobile phase was 25 mmol L−1 ammonium acetate (pH 7.5)-methanol, 90:10 (v/v), at a flow rate of 0.6 mL min−1. The temperature of the drift tube of the ELSD was 95°C and the flow rate of carrier gas was 2.2 L min−1. The accuracy, specificity, precision, linearity, sensitivity, and robustness of the method were validated in accordance with ICH guidelines. In addition to determination of spectinomycin and related impurities, the method is also ideal for determination of the salts spectinomycin hydrochloride and spectinomycin sulfate.  相似文献   

19.
《Electroanalysis》2005,17(23):2156-2162
In this work an automated flow methodology based on a tubular amperometric detector coupled to a multicommutated flow system was developed and applied in the determination of uric acid in urine. The exploitation of the analytical potential of multicommutated flow systems allowed the implementation of an expeditious and easily controlled on‐line sample dilution, based on the zone sampling approach. The dilution capability exhibited by the developed methodology allowed a direct insertion of the samples in the flow system, without any pretreatment, assuring faster, simpler and less expensive analyses when compared to the enzymatic based methods with spectrophotometric detection commonly used in clinical analyses. The results obtained with the developed system in the determination of uric acid in urine were compared with those obtained by the enzymatic method used in clinical analysis laboratories, and no statistical difference between both methods (for a confidence level of 95%) was found. The proposed system showed good repeatability (RSD<3%, n=10) and a detection limit of 4×10?7 mol L?1.  相似文献   

20.
This study proposes, a simple, rapid and sensitive chemiluminescent (CL) method for determination of carbofuran based on diperiodatoargentate(III) (DPA)-sulfuric acid (H2SO4) reaction coupled with flow injection (FI) methodology. Under optimum conditions, a linear standard curve is achieved in the range of 0.001–8.0 mg L–1 (R2= 0.9994 (n = 11) with relative standard deviation (RSD) of 1.4–3.7% (n = 4)), a limit of detection (LOD) 5.0 × 10–4 mg L–1 (S/N = 3) and injection throughput 180 h–1. The proposed method was applied satisfactorily for the analysis of carbofuran in freshwater samples using solid phase extraction (SPE) technique with the recoveries of 94–110% (% RSD = 1.7–3.8, n = 4). A possible CL reaction mechanism has also been discussed briefly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号