首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary Comparative results of pre-treatment methods for the extracts of polycyclic aromatic hydrocarbons (PAHs) from airborne particulate matter for quantitative determination by gas chromatography (GC) are presented. The first method included liquid-liquid extraction and column liquid adsorption chromatography. In the second procedure the extract was fractionated by liquid-liquid chromatography and liquid adsorption chromatography. In the last procedure two different solid phase extraction (SPE) cartridges examined makes it possible to separate PAHs and remove paraffinic compounds which is very important for the quantitative GC analysis of the PAHs. Recoveries of PAH standards and some their derivatives were determined and the contents of 15 of the most important PAHs, were compared. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

2.
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring.  相似文献   

3.
Summary Using a two-step liquid chromatographic separation on normalphase cartridges, crude extracts of diesel particulate matter can be separated without time-consuming sample handling into special fractions which mainly contain slightly-polar oxygenated polycyclic aromatic hydrocarbons (oxy-PAH) and nitrated polycyclic aromatic hydrocarbons (nitro-PAH). Subsequent analysis was by fused-silica capillary gas chromatography on a SE54 column along with flame-ionisation (GC/FID) and positive-ion electron-impact mass spectrometric detection (GC/MS) respectively. A number of individual oxy-PAH belonging to four different chemical classes (ketones, quinones, anhydrides and aldehydes) and several individual nitro-PAH were characterized by their retention times and mass spectra. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

4.
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid‐phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid‐phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0–1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015–0.591 and 0.045–1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1‐monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m?3. 9,10‐Dichloroanthracene and 1‐monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water.  相似文献   

5.
Thermal desorption gas chromatography mass spectrometry (TD-GC/MS) is becoming more commonly used for the quantification and identification of organic compounds in particulate matter (PM), including ambient and source PM such as diesel particulate matter (DPM). It has been proven as an alternative to the traditional solvent extraction (SE) method and liquid injection gas chromatograph mass spectrometry (LI-GC/MS). However, little information is available on how different types of TD-GC/MS systems compare to each other for analysis of real-world PM samples or to direct LI-GC/MS for analysis of PM components in a test solution. To address this, CanmetENERGY Characterization Laboratory initiated a round robin with the participation of 10 laboratories worldwide. Three sample types were analysed: (i) a test solution with a suite of pure compounds commonly found in PM, analysed by TD-GC/MS and LI-GC/MS; (ii) a DPM sample, analysed by TD-GC/MS and SE; and (iii) an ambient PM sample, analysed by TD-GC/MS. The first part of the study showed good overall performance and comparability between the different TD-GC/MS systems and LI-GC/MS method for the analysis of PM components in a test solution, with some variability of results due to system types and parameters used, concentration of calibration standards, and whether or not an internal standards was used. The analysis of the DPM sample showed greater variability between laboratories and methods as many PM components were present near the detection limit and matrix effects particularly affected the TD-GC/MS analysis of heavier n-alkanes. In the last part of the study, for the analysis of an ambient PM sample by TD-GC/MS, the analysis of variance showed good comparison between labs for polycyclic aromatic hydrocarbons (94% non-significant), but slightly lower for n-alkanes (68%) and biomarkers (57%).  相似文献   

6.
Thirteen polycyclic aromatic hydrocarbons have been determined in soy‐based nutraceutical products. First, an optimization of extraction procedure was performed, and a solid–liquid extraction assisted by sonication and a dilute and shoot procedure were compared, selecting the dilute and shoot approach for the extraction of target compounds, utilizing a mixture of acetone/n‐hexane (1:1 v/v) as extractant solvent. After this, a clean‐up step was needed bearing in mind the complexity of these matrices. Dispersive solid‐phase extraction, using a mixture of C18 and Zr‐Sep+ (25 mg/mL each) was used. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. For quantification purposes, matrix‐matched calibration was used. The validation was applied at three concentration levels (20, 100 and 250 μg/kg), obtaining recoveries between 70 and 120% and precision values equal to or lower than 23%. Limits of detection and quantification were below 8 and 20 μg/kg, respectively. The method was applied in 11 samples, detecting five polycyclic aromatic hydrocarbons at concentrations ranging from 4.1 to 18.5 μg/kg.  相似文献   

7.
Abstract

The methodologies are described for isolating clean fractions of polycyclic aromatic compounds from diverse environmental samples such as air particulate matter, sediments, and fish tissue. The common step in all procedures is the separation of the polycyclic aromatic compound fraction into well-defined chemical classes by adsorption chromatography on an alumina column. These procedures greatly facilitate the detailed characterization of the polycyclic aromatic hydrocarbons, sulfur heterocycles, and nitrogen heterocycles by capillary column gas chromatography.  相似文献   

8.
Semivolatile organic compounds are a category of organic micropollutants including phthalate esters, polycyclic aromatic hydrocarbons and so on, which are commonly analyzed by solid‐phase extraction followed by gas chromatography with mass spectrometry. In this work, a highly sensitive and feasible method of magnetic solid‐phase extraction combined with gas chromatography with mass spectrometry was established for the determination of semivolatile organic compounds in water. The novel method was based on a permanent magnetic resin with uniform particle size and high surface area (1154.3 m2/g). The results demonstrated that the extraction efficiency of the resin was superior to that of a C18 cartridge. The method was proved to be of satisfactory recoveries (75–115.7%) and limits of detection and quantification (0.063–6.524 and 0.212–21.745 μg/L, respectively). The method was applied to the analysis of semivolatile organic compounds in the midstream Huai River. It was observed that polychlorinated biphenyls exceeded current water standards. To further illustrate the potential effects on human health, health risk assessment was conducted based on the obtained data. The existence of health risk was proved, with hexachlorobenzene and 2,2’,4,4’‐tetrachlorobiphenyl as the major causes. The method possesses the characteristics of high efficiency and rapid analysis, offering a good prospect of applications in large quantities of practical water.  相似文献   

9.
Nitrated polycyclic aromatic hydrocarbons (NPAHs) in airborne particulate were determined by column liquid chromatography with electrochemical detection. NPAHs were extracted ultrasonically prior to being injected into the separation system. A reversed-phase C18 column was used to separate the NPAHs with an aqueous eluent containing acetonitrile and sodium monochloroacetate as buffer. Calibration graphs were linear with very good correlation coefficients (r>0.999) and the detection limits were ca. 20 pg for all analytes. The proposed method provides a relatively simple and convenient procedure for determining the NPAHs in airborne particulate.  相似文献   

10.
A method for the determination of 16 polycyclic aromatic hydrocarbons in water has been developed. First, we made a solid‐phase extraction column. After this, the parameters affecting the efficacy of the experimental method were optimized, including appropriate selection of a solid‐phase extraction column and cleanup conditions on columns. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. The method showed satisfactory linearity (R> 0.999) over the range assayed (0.01–1 μg/mL), and limits of quantification ranging from 0.0011 to 0.0199 μg/L. The recoveries ranged from 83 to 113%. The relative standard deviation is in the range 0.86–3.1%. The results indicated that this method had high selectivity and precision that was suitable for the simultaneous determination of 16 polycyclic aromatic hydrocarbons in water.  相似文献   

11.
A stable isotope dilution liquid chromatography tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04–1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 versus 2859.50 ng/cig, p < 0.05). Meanwhile, the concentration of individual polycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurate quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking.  相似文献   

12.
Nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) are widespread environmental pollutants that are generated by incomplete combustion and by atmospheric transformation of polycyclic aromatic hydrocarbons (PAHs). Many nitro-PAH compounds are potent genotoxins and some are direct acting mutagens. Detection of nitro-PAHs in aerosols is complicated by small sample sizes and nitro-PAH abundances that are 1–2 orders of magnitude less than analogous unsubstituted PAHs. Selective detection of several nitro-PAHs by using laser desorption ionization time-of-flight mass spectrometry in negative ion mode has been achieved. Desorption and ionization of nitro-PAHs were effected by using pulsed UV radiation at 266 and 213 ran. Intense molecular anions were observed in addition to fragments identified as CN? and NO 2 ? , which were characteristic indicators of the presence of nitro-PAHs. Selective detection of nitro-PAHs in negative ion mode was demonstrated in the analysis of a diesel particulate sample.  相似文献   

13.
A sensitive method is described for the determination of mono-, di- and tri-methylarsenic compounds in airborne particulate matter by hydride-generation and gas-liquid chromatography with atomic absorption spectrometric detection. Interferences of various species are discussed. Absolute detection limits are 70, 80 and 100 pg As, respectively for the mono-, di- and tri-methylarsenic species. Recoveries of methylarsenic compounds added to airborne particulate matter are almost 100%. An iron/nitrate mixture interfered strongly but this was overcome by adding EDTA.  相似文献   

14.
An efficient clean-up procedure coupled with a high performance liquid chromatography (HPLC) with on-line electrochemical (EC) reduction and fluorescence detection (FLD) was developed to quantify nitrated polycyclic aromatic hydrocarbons (NPAHs) in the airborne particulate. In this process, NPAHs were extracted ultrasonically followed by analysis by using a reversed phase column with an aqueous eluent containing 70% aqueous acetonitrile and sodium monocholoroacetate as a buffer solution. The extraction efficiencies were above 83% for 1-nitropyrene and 1,3-dinitropyrene (1,3-DNP) 1,6-DNP, and 1,8-DNP, and calibration graphs were linear with very good correlation coefficients (r>0.999) and the detection limits were in the range of 1.0-2.2 pg for dinitropyrenes and nitropyrene. The proposed method provides a relatively simple and convenient procedure for determining the NPAHs samples in airborne particulate.  相似文献   

15.
A gas chromatography with ion trap mass spectrometry method has been developed and validated for the analysis of 27 polar organic compounds in atmospheric aerosols. The target analytes were low‐molecular‐weight carboxylic acids and methoxyphenols, as relevant markers of source emissions and photochemical processes of organic aerosols. The operative parameters were optimized in order to achieve the best sensitivity and selectivity for the analysis. In comparison with the previous gas chromatography with mass spectrometry procedure based on single ion monitoring detection, the tandem mass spectrometry technique increased the analytical sensitivity by reducing detection limits for standard solutions from 1–2.6 to 0.1–0.4 ng/μL ranges (concentrations in the injected solution). In addition, it enhanced selectivity by reducing matrix interferences and chemical noise in the chromatogram. The applicability of the developed method in air quality monitoring campaigns was effectively checked by analyzing environmental samples collected in the Po Valley (Northern Italy) in different seasons. The obtained results indicate that the ion trap mass spectrometer may be an ideal alternative to high‐resolution mass spectrometers for the user‐friendly and cost‐effective determination of a wide range of molecular tracers in airborne particulate matter.  相似文献   

16.
An analytical method using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization for the determination of polycyclic aromatic hydrocarbons in asphalt fractions has been developed. The 14 compounds determined, characterized by having two or more condensed aromatic rings, are expected to be present in asphalt and are considered carcinogenic and mutagenic. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection ranged from 0.5 to 346.5 μg/L and the limits of quantification ranged from 1.7 to 1550 μg/L. The method was validated against a diesel particulate extract standard reference material (NIST SRM 1975), and the obtained concentrations agreed with the certified values. The method was applied to asphalt samples after its fractionation according to ASTM D4124 and the method of Green. The concentrations of the seven polycyclic aromatic hydrocarbons quantified in the sample ranged from 0.86 mg/kg for benzo[ghi]perylene to 98.32 mg/kg for fluorene.  相似文献   

17.
We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid–liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1–84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono‐ and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment.  相似文献   

18.
A multiclass method has been developed for screening, quantification and confirmation of organic micro-pollutants in water by gas chromatography coupled to mass spectrometry with a triple quadrupole analyzer. The work has been focused on the determination of more than 50 compounds belonging to different chemical families: 19 organochlorine and organophosphorus insecticides, 6 herbicides, 7 polychlorinated biphenyls, 16 polycyclic aromatics hydrocarbons, 2 brominated diphenyl ethers, and 3 octyl/nonyl phenols and pentachlorobenzene. Most of these analytes are included in the list of priority substances in the framework on European Water Policy.Analyte extraction was performed by solid phase extraction using C18 cartridges, and five isotopically labeled standards were added before extraction as surrogates. Analyses were performed by gas chromatography with tandem mass spectrometry (MS/MS) in electron impact mode. Accuracy and precision were evaluated by means of recovery experiments using water samples fortified at two concentration levels (25 and 250 ng L−1), with satisfactory results for most of analytes. The excellent selectivity and sensitivity reached in selected reaction monitoring mode allowed us satisfactory quantification and confirmation at levels as low as 25 ng L−1. Two MS/MS transitions were acquired for each analyte, using the Q/q intensity ratio as a confirmatory parameter. The method developed was applied to the analysis of surface, ground and wastewater samples collected from the Valencia Region (Spain).Analytical methodology using negative chemical ionization mode was also validated for the organochlorine compounds selected, showing a superior sensitivity and lower detection limits.  相似文献   

19.
A method for the separation of polycyclic aromatic hydrocarbons (PAHs) by high-performance liquid chromatography using a hybrid micellar mobile phase is described. The detection of PAHs was carried out using the fluorescence method with programmable excitation and emission wavelength. The method is applied to the analysis of several environmental samples (sea water, sediments, limpets, sea worms) and several of these compounds are quantitated at concentration below 70 ng L−1(kg−1) in the original samples.  相似文献   

20.
The methodologies are described for isolating clean fractions of polycyclic aromatic compounds from diverse environmental samples such as air particulate matter, sediments, and fish tissue. The common step in all procedures is the separation of the polycyclic aromatic compound fraction into well-defined chemical classes by adsorption chromatography on an alumina column. These procedures greatly facilitate the detailed characterization of the polycyclic aromatic hydrocarbons, sulfur heterocycles, and nitrogen heterocycles by capillary column gas chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号