首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A green and robust reverse-phase liquid chromatographic method has been developed for the determination of fenoverine (FEN), by applying combined principles of green analytical chemistry and quality by design approaches on a Spherisorb C18 column (150?×?4.6?mm, 3?µm) with UV detection at 262?nm. A two level fractional factorial design (2^7-3) Res IV was used for screening of influential chromatographic factors. The critical method parameters actively affecting critical quality attributes (CQAs) were identified and further optimized using Box–Behnken design. The predicted optimum assay conditions comprised of methanol and ammonium acetate buffer 20?mM, in an extent of 81:19% v/v individually having a flow rate of 1.0?mL/min with a column oven temperature of 33°C. The drug was stressed in hydrolytic, oxidative, reductive, thermal, and photolytic conditions. The developed method was validated successfully. The detector response was linear in the concentration of 0.5–160?µg/mL with a limit of detection (LOD) and limit of quantitation (LOQ) as 0.1 and 0.3?µg/mL, respectively. The % recovery was found to be 99.7%. The analytical method volume intensity value for developed method was 45?mL and the environment assessment tool (EAT) score was 41.07. The method is simple, environmentally benign, rapid, and robust for the determination of FEN in bulk and in its dosage form.  相似文献   

2.
A fast, feasible, isocratic, stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method has been developed and validated for the quantitative determination of marbofloxacin in marbofloxacin tablets. The method was developed using Zorbax SB C18 (150?mm?×?4.6?mm), 5-µm column thermostated at 30°C, mobile phase A (1?mL of trifluoroacetic acid in 1000?mL of water), mobile phase B (acetonitrile) in the ratio of 83:17?v/v at flow rate of 1.0?mL/min, and an injection volume of 10?µL. The analyte was monitored at a wavelength of 298?nm. The method was validated in accordance with the Food and Drug Administration (FDA) Veterinary International Conference on Harmonization guidelines. To demonstrate stability indicating ability of method, drug product was subjected to the stress condition of acidic, basic, humidity, thermal, oxidative, and photolytic degradation.  相似文献   

3.
Methotrexate (MTX) is an anticancer drug while metoclopramide (MCP) is an antiemetic agent. Both the drugs are commonly coprescribed to avoid the emesis caused by anticancer drug. In this study, a novel, rapid, sensitive, and cost-effective reverse-phase high-performance liquid chromatography method was developed and validated for simultaneous determination of the methotrexate and metoclopramide in biological and pharmaceutical samples using sparfloxacin as internal standard. The analytes were separated on a Kromasil 100-5C18 RP (250?×?4.6?mm, 5?µm) column, methanol, and 0.05% trifloroacetic acid (36:64?v/v) as mobile phase with a flow rate of 1?mL/min, detection wavelength of 290?nm, and column oven temperature at 40°C. Both the analytes were extracted from physiological fluids (bovine aqueous humor, vitreous humor, and human plasma) using mixture of methanol and 10% perchloric acid (50:50 v/v). The method was linear over the concentration range of 0.025–1.0?µg/mL for methotrexate and 0.030–1.0?µg/mL for metoclopramide. The % recovery from human plasma was 98.57 and 96.74% for MTX and MCP, respectively, while from aqueous humor and vitreous humor was 95.84 and 98.51% for MTX.

The developed method was applied for in vitro release of MTX from polymeric nanoparticles and can be applied for analysis of pharmaceutical and biological samples containing both the drugs.  相似文献   

4.
In the present investigation, a simple and isocratic HPLC‐UV method was developed and validated for determination of rilpivirine (RPV) from dosage forms (tablets and nanoparticles) and biological matrices like HeLa cell lysates. The separation and analysis of RPV was carried out under isocratic conditions using (a) a Gemini reversed‐phase C18 column (5 µm; 4.6 × 150 mm) maintained at 35°C, (b) a mobile phase consisting of a mixture of acetonitrile and 25 m m potassium dihydrogen phosphate (in the ratio 50:50 v/v) at a flow rate of 0.6 mL/min and (c) atazanavir as an internal standard. The total run time was 17 min and the analysis of RPV and internal standard was carried out at 290 nm. The method was found to be linear (r2 value > 0.998), specific, accurate and precise over the concentration range of 0.025–2 µg/mL. The lower limit of quantification was 0.025 µg/mL, the limit of detection was 0.008 µg/mL and the recovery of RPV was >90%. The stability of the RPV analytical method was confirmed at various conditions such as room temperature (24 h), ?20°C (7 days), three freeze?thaw cycles and storage in an autosampler (4°C for 48 h). The method was successfully applied for the determination of RPV from conventional dosage forms like tablets, from polymeric nanoparticles and from biological matrices like HeLa cell lysates. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
The current work entails development of rapid, sensitive, and inexpensive high-performance liquid chromatographic method of quercetin dihydrate using the quality by design approach. Quality target method profile was defined and critical analytical attributes (CAAs) were earmarked. Chromatographic separation was accomplished on a C18 column using acetonitrile and ammonium acetate buffer (35:65) %v/v (containing 0.1% acetic acid, pH 3.5) as mobile phase at 0.7?mL/min flow rate with UV detector at 237?nm. Screening studies using fractional factorial design revealed that organic modifier, injection volume, column temperature, and buffer strength have significant influence on method CAAs, namely, peak area, retention time, and peak tailing. The critical method parameters were systematically optimized using Box–Behnken design. Response surface mapping was used along with numerical optimization and desirability function for identifying the optimal chromatographic conditions. Linearity was observed in the drug concentration ranging between 2 and 50?µg/mL. Accuracy analysis revealed mean % recovery between 93.6 and 96.2%, while precision study revealed mean % recovery between 93.7 and 96.5%. Limits of detection and quantification of the developed method were found to be 12.1 and 36.6?ng/mL. Overall, the studies construed successful development of chromatographic method of quercetin with enhanced method performance.  相似文献   

6.
A systematic design-of-experiments was performed by applying quality-by-design concepts to determine design space for rapid quantification of teriflunomide by the ultraperformance liquid chromatography (UPLC) method in the presence of degradation products. Response surface and central composite quadratic were used for statistical evaluation of experimental data using a Design-Expert software. The response variables such as resolution, retention time, and peak tailing were analyzed statistically for the screening of suitable chromatographic conditions. During this process, various plots such as perturbation, contour, 3D, and design space were studied. The method was developed through UPLC BEH C18 2.1?×?100?mm, 1.7-µ column, mobile phase comprised of buffer (5?mM K2HPO4 containing 0.1% triethylamine, pH 6.8), and acetonitrile (40:60 v/v), the flow rate of 0.5?mL?min?1 and UV detection at 250?nm. The method was developed with a short run time of 1?min. Forced degradation studies revealed that the method was stability-indicating, suitable for both assay and in-vitro dissolution of a drug product. The method was found to be linear in the range of 28–84?µg?mL?1, 2.8–22.7?µg?mL?1 with a correlation coefficient of 0.9999 and 1.000 for assay and dissolution, respectively. The recovery values were found in the range of 100.1–101.7%. The method was validated according to ICH guidelines.  相似文献   

7.
A systematic Quality by Design approach was employed for developing an isocratic reversed‐phase liquid chromatographic technique for the estimation of ropinirole hydrochloride in bulk drug and pharmaceutical formulations. LiChrospher RP 18‐5 Endcapped column (25 cm × 4.6 mm id) at ambient temperature (25 ± 2°C) was used for the chromatographic separation of the drug. The screening of factors influencing chromatographic separation of the active pharmaceutical ingredient was performed employing fractional factorial design to identify the influential factors. Optimization of the selected factors was carried out using central composite design for selecting the optimum chomatographic conditions. The mobile phase employed was constituted of Solvent A/Solvent B (65:35 v/v) (Solvent A [methanol/0.05 M ammonium acetate buffer, pH 7, 80:20 v/v] and Solvent B [high performance liquid chromatography grade water]) and used at 0.6 mL/min flow rate, while UV detection was performed at 250 nm. Linearity was achieved in the drug concentration range 5–100 µg/mL (R= 0.9998) with limits of detection and quantification of 1.02 and 3.09 µg/mL, respectively. Method validation was performed as per ICH guidelines followed by forced degradation studies, which indicated good specificity of the developed method for detecting ropinirole hydrochloride and its possible degradation products in the bulk drug and pharmaceutical formulations.  相似文献   

8.
Paliperidone is an antipsychotic drug, which is used for the acute and maintenance treatment of schizophrenia. In this study, a new method was developed for the determination of Paliperidone in its extended-release tablets. Face-centered central composite design was applied for optimization of the method. Factors were decided as acetonitrile content, pH of the mobile phase and buffer concentration through preliminary studies. Optimal flow rate (1?mL/min), column temperature (35°C) and internal standard (Bupropion) were also determined during preliminary studies. Retention factors and tailing factors of Paliperidone and Bupropion were selected as responses. Derringer’s desirability function was applied for simultaneously optimization of these four responses. Optimal conditions were predicted as phosphate buffer (pH:3, 23?mM): acetonitrile (76:24, v:v). Developed method was validated in terms of linearity, detection and quantification limits, accuracy, precision, specificity and robustness. Method was found linear in the concentration range of 0.125-100?µg/mL. Mean equation of the calibration curve was y?=?0.0807 x - 0.0102 (R2?=?0.9999). Accuracy and precision of the method was evaluated with recovery values (98-102%) and relative standard deviation values (<2%), respectively. All other parameters were found acceptable. The method was successfully applied for the determination of Paliperidone in its extended-release tablets.  相似文献   

9.
A micellar high-performance liquid chromatographic method was developed to simultaneously determine ephedrine and pseudoephedrine in human serum. The serum sample pretreatment was a simple dilution in a micellar solution, filtration, and direct injection, thus avoiding time-consuming and tedious steps. Hence, there is no need to use an internal standard. The serum samples were analyzed using a mobile phase containing 1.50?×?10?1?mol/L sodium dodecyl sulfate and 0.02?mol/L sodium dihydrogen phosphate with 7.5% (v/v) 1-propanol at pH 3.0, running at 1.0?mL/min by an Inertsil C18 (150?×?4.6?mm, 5?µm) column at 30°C. The UV wavelength was set at 210?nm. The developed method was validated by linearity (r?>?0.9990) and intra- and inter-day precisions of ephedrine and pseudoephedrine (relative standard deviation; RSD%, 0.04–10.40, and RSD %, 0.30–10.25, respectively), LODs for ephedrine and for pseudoephedrine was 2.63 and 2.70?µg/mL, respectively; lower limit of quantification for ephedrine and for pseudoephedrine was 4.38 and 4.51?µg/mL, respectively. Finally, the proposed method was applied to investigate ephedrine and pseudoephedrine in real human serum samples after oral administration of Kechuanning Koufye including Ephedra herb. It is environmentally friendly, easy-to-handle, and feasible method for routine analysis in clinical laboratory.  相似文献   

10.
A methodical design-of-experiments were performed by applying quality-by-design concepts to establish a design-space for simultaneous and rapid quantification of Carvedilol and Ivabradine by UPLC in the presence of degradation products. Response-surface, central-composite design, and quadratic model were employed for statistical assessment of experimental data using the Design-Expert software. Response variables such as resolution and retention time were analyzed statistically for chromatographic screening. During DoE study, various plots such as perturbation, contour, 3D and design-space plots were considered for method optimization. The method was developed using C8 [100?×?2.1?mm, 1.8?µ] UPLC column, mobile phase comprising 0.5% triethylamine buffer [pH 6.4] and acetonitrile in the ratio of 50:50 v/v, the flow rate of 0.4?mL minute?1 and UV detection at 285?nm for both Carvedilol and Ivabradine. The method was developed with a short run time of two minutes. The method was found to be linear in the range of 25.0–199.9?µg?mL?1 and 8.9–21.3?µg?mL?1 for Carvedilol and Ivabradine, respectively with a correlation coefficient of 0.9998 in each case. The recovery values were found in the range of 99.7–100.8% and 98.9–100.9% for Carvedilol and Ivabradine, respectively. The method was validated according to ICH Q2 (R1) guidelines.  相似文献   

11.
Based on an official standard method of lutein analysis, an improved high performance liquid chromatography (HPLC) method for simultaneously detecting lutein and zeaxanthin was developed as focusing on the sample preparation protocol. The optimal pretreatment conditions included a saponification in a water bath for 15?min at a constant temperature of 50?°C, using a 10?mL 60% (w/v) potassium hydroxide solution, followed by extraction using 100?mL mixture of n-hexane, ethyl ether and cyclohexane (40: 40: 20, v/v/v). A mixture of dichloromethane, acetonitrile and methanol (20: 30: 50, v/v/v) was validated to elute lutein and zeaxanthin on a C30 column (4.6?×?250?mm, 5?µm). The resolution between lutein and zeaxanthin is ≥2.5. A millet sample was used for methodological verification and the results showed that the linear relations for lutein and zeaxanthin were good in ranges of 0.23–9.37?μg/mL and 0.30–12.02?μg/mL, respectively. The relative standard deviations of lutein and zeaxanthin were 1.40% and 5.09%, respectively, and their spiked recoveries were between 86.60% and 98.75%. The lutein and zeaxanthin results from this modified HPLC method are superior to those from the Chinese official method and ultrasonic extraction method.  相似文献   

12.
A rapid high‐performance liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous measurement of venlafaxine and O‐desmethylvenlafaxine in human plasma using fluoxetine as an internal standard. In the liquid–liquid extraction method, compounds and internal standard were extracted from plasma using methyl tertiary butyl ether as an extraction solvent. The HPLC separation of the analytes was performed on a Zorbax SB‐C18, 50 × 4.6 mm, 5 µm column, using a isocratic elution program using a mobile phase consisting of HPLC‐grade methanol: 5 mm ammonium acetate (80:20 v/v) at a flow‐rate of 1.0 mL/min with a total runtime of 3.0 min. The proposed method has been validated with a linear range of 4–400 ng/mL for venlafaxine and 5–500 ng/mL for O‐desmethyl venlafaxine. The method was applied for a bio‐equivalence study of 75 mg tablets formulation in 32 Indian male healthy subjects under fasting conditions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid, accurate, and precise HPLC method has been developed for simultaneous determination of four contraceptive hormonal compounds namely ethinylestradiol (EE), drospirenone (DR), gestodene (GS), and levonorgestrel (LV) in oral contraceptive tablet dosage form. The chromatographic separation was achieved on a C18 (150 × 4.6 mm, 5μ) column; the mobile phase consists of acetonitrile: water (50:50, v/v) pumped at a flow rate of 1.0 mL/min; and UV detection was set at 200 nm. The limit of detection was 0.0086 µg/mL for (EE), 0.0397 µg/mL for (GS), 2.80 µg/mL for (DR), and 0.229 µg/mL for (LV), whereas the limit of quantitation (LOQ) was 0.028 µg/mL for (EE), 0.132 µg/mL for (GS), 9.500 µg/mL for (DR), and 0763 µg/mL for (LV), respectively. The correlation coefficient (r) values of the four compounds ranged from 0.99995 to 0.99999. The method was validated as per ICH guidelines and USP 34 for estimation of (EE), (DR), (GS), and (LV) in commercially available tablet dosage form. The validation results were found satisfactory. The proposed method can be useful in quality control of bulk manufacturing and pharmaceutical dosage forms.  相似文献   

14.
A simple high‐performance liquid chromatography method for the determination of cefovecin in small volume plasma has been developed. Following solid‐phase extraction using Oasis HLB cartridges, samples were separated by reverse‐phase high‐performance liquid chromatography on an XBridge C8 (3.5 µm) 4.6 × 250 mm column and quantified using ultraviolet detection at 280 nm. The mobile phase was a mixture of 10 mm ammonium acetate (pH 3.5) and acetonitrile (89:11), with a flow rate of 0.85 mL/min. The standard curve ranged from 0.1 to 200 µg/mL. Intra‐ and Inter‐assay variability for cefovecin was <10%, and the average recovery was >90%. The lower limit of quantitation was 0.1 µg/mL. This method was successfully applied to the analysis of cefovecin samples at our institution. This is also the first fully validated method with an internal standard that does not use mass spectrometry. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Lansoprazole, a selective proton pump inhibitor, has a chiral benzimidazole sulfoxide structure and is used for the treatment of gastric acid hypersecretory related diseases. To investigate its stereoselective pharmacokinetics, a column‐switching liquid chromatography with tandem mass spectrometry method was developed for the determination of lansoprazole enantiomers in dog plasma using (+)‐pantoprazole as an internal standard. After a simple protein precipitation procedure with acetonitrile, matrix components left behind after sample preparation were further eliminated from the sample by reversed‐phase chromatography on a C18 column. The fluent was fed to a chiral column for the separation of lansoprazole enantiomers. Baseline separation of lansoprazole enantiomers was achieved on a Chiralcel OZ‐RH column using acetonitrile/0.1% formic acid in water (35:65, v/v) as the mobile phase at 40°C. The linearity of the calibration curves ranged from 3 to 800 ng/mL for each enantiomer. Intra‐ and inter‐day precisions ranged from 2.1 to 7.3% with an accuracy of ±1.7% for (+)‐lansoprazole, and from 1.6 to 6.9% with an accuracy of ±3.5% for (–)‐lansoprazole, respectively. The validated method was successfully applied for the stereoselective pharmacokinetic study of lansoprazole in beagle dog after intravenous infusion.  相似文献   

16.
Extraction and determination of seven aromatic amines in environmental water samples were performed with solid-phase extraction (SPE) and micellar liquid chromatography (MLC) using experimental design. Extraction of aromatic amines was carried out with a C18 cartridge modified with sodium dodecyl sulphate (SDS). The washing solution and elution solvent for extraction of aromatic amines were aqueous solution containing 5% (v/v) acetonitrile and 5% (v/v) acetone and 3 mL methanol, respectively. The chemometrics approach was applied for the separation optimisation of these compounds using MLC. Different mobile phase compositions were used for modelling based on retention times to obtain the best separation using central composite design. The optimum mobile phase composition for separation and determination of analytes in water samples was 69 mM SDS, 9% v/v 1-propanol and pH = 6.4. Recoveries were between 84.8–93.5% with relative standard deviation (RSD) less than 5.8% (n = 5). Limits of detection and linear range were 1–4.5 and 3.1–125.0 µg/L, respectively. The proposed method was applied to determine the aromatic amines in real samples (river and well waters). Amount of 4-nitroaniline and 3-nitroaniline in river water sample were 2.15 and 1.91 µg/L, respectively.  相似文献   

17.
A simple, sensitive and specific liquid chromatography tandem mass spectrometry (LC‐ESI‐MS/MS) method was developed for the quantification of desvenlafaxine in human plasma using desvenlafaxine d6 as an internal standard (IS). Chromatographic separation was performed using a Thermo‐BDS hypersil C8 column (50 × 4.6 mm, 3 µm) with an isocratic mobile phase composed of 5 mM ammonium acetate buffer: methanol (20:80, v/v), at a flow rate of 0.80 mL/min. Desvenlafaxine and desvenlafaxine d6 were detected with proton adducts at m/z 264.2/58.1 and 270.2/ 64.1 in multiple reaction monitoring positive mode, respectively. Liquid–liquid extraction was used to extract the drug and the IS. The method was linear over the concentration range 1.001–400.352 ng/mL with a correlation coefficient of ≥0.9994. This method demonstrated intra and inter‐day precision within 0.7–5.5 and 1.9–6.8%, and accuracy within 95.3–107.4 and 93.4–99.5%. Desvenlafaxine was found to be stable throughout the freeze–thaw cycles, bench‐top and long‐term matrix stability studies. The developed and validated method can be successfully applied for the bioequivalence/pharmacokinetic studies of desvenlafaxine in pharmaceutical dosage forms. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
《Analytical letters》2012,45(12):1784-1804
Abstract

High-performance liquid-chromatographic (HPLC) methods were validated for determination of pravastatin sodium (PS), fluvastatin sodium (FVS), atorvastatin calcium (ATC), and rosuvastatin calcium (RC) in pharmaceuticals. Two stability-indicating HPLC methods were developed with a small change (10%) in the composition of the organic modifier in the mobile phase. The HPLC method for each statin was validated using isocratic elution. An RP-18 column was used with mobile phases consisting of methanol–water (60:40, v/v, for PS and RC and 70:30, v/v, for FVS and ATC). The pH of each mobile phase was adjusted to 3.0 with orthophosphoric acid, and the flow rate was 1.0 mL/min. Calibration plots showed correlation coefficients (r) > 0.999, which were calculated by the least square method. The detection limit (DL) and quantitation limit (QL) were 1.22 and 3.08 µg/mL for PS, 2.02 and 6.12 µg/mL for FVS, 0.44 and 1.34 µg/mL for ATC, and 1.55 and 4.70 µg/mL for RC. Intraday and interday relative standard deviations (RSDs) were <2.0%. The methods were applied successfully for quantitative determination of statins in pharmaceuticals.  相似文献   

19.
The determination of alendronate (ALE) in biofluids using a low-cost instrument is potentially useful in preclinical pharmacokinetic studies. This study developed and validated a high-performance liquid chromatography with ultraviolet method for ALE determination in rat plasma using precolumn derivatization with phenyl isothiocyanate (PITC). Inhibiting compounds in the samples were first eliminated using solid-phase extraction. ALE in the sample was subsequently allowed to react with PITC to form a phenylthiocarbamoyl derivative for further analysis. The assay was linear within the concentration range of 0.29–25.0?µg/mL. The precision and accuracy were less than 3.9% and 98.0?±?3.9%, respectively. The limits of detection and quantification were 0.08 and 0.20?µg/mL, respectively. The method was successfully used to evaluate the pharmacokinetic parameters of ALE in rats following a single oral administration (30.0?mg/kg). The results show that the peak plasma ALE concentration is 0.69?±?0.18?µg/mL. The area under the plasma concentration–time curve value of ALE was 2.14?±?0.68?µg/mL hr. This method can suitably evaluate the bioavailabilities of different ALE dosage forms in preclinical pharmacokinetic studies.  相似文献   

20.
This paper describes a sensitive, specific and rapid high‐performance liquid chromatography (HPLC) method for the determination of curcumin in rat plasma. After a simple step of protein precipitation in 96‐well format using acetonitrile containing the internal standard (IS), emodin, plasma samples were analyzed by reverse‐phase HPLC. Curcumin and the IS emodin were separated on a Diamonsil C18 analytical column (4.6 × 100 mm, 5 µm) using acetonitrile–5% acetic acid (75:25, v/v) as mobile phase at a flow rate of 1.0 mL/min. The method was sensitive with a lower limit of quantitation of 1 ng/mL, with good linearity (r2 ≥ 0.999) over the linear range 1–500 ng/mL. All the validation data, such as accuracy and precision, were within the required limits. A run time of 3.0 min for each sample made high‐throughput bioanalysis possible. The assay method was successfully applied to the study of the pharmacokinetics of curcumin liposome in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号