首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For the fluorimetric determination of isatin in human urine and serum, HPLC-postcolumn photoirradiation using a mobile phase has been developed. Isatin in the urine or serum sample was separated on a Capcell Pak C1 column (250 x 4.6 mm id). The mobile phase consisted of 70 mmol l-1 phosphate buffer (pH 7.2)-tetrahydrofuran (85 + 15% v/v) containing 5 mmol l-1 hydrogen peroxide, which was irradiated with germicidal light to induce fluorescence (lambda ex 302 nm, lambda em 418 nm). The addition of tetrahydrofuran to the mobile phase led to the peaks showing good separation as well as increased sensitivity. The calibration graph for isatin was linear over the range of 0.16-10.7 ng. The pretreatment of the acidified urine or serum samples consisted of diluting steps or deproteinizing steps using perchloric acid, respectively. The mean recovery of isatin from urine and serum was greater than 94%.  相似文献   

2.
Nano-liquid chromatography-mass spectrometry (nano-LC-MS) was evaluated for the separation of basic compounds of pharmaceutical interest. The separation of selected beta-blockers, namely nadolol, oxprenolol, alprenolol and propranolol in the presence of terbutaline was performed using two 75 microm I.D. capillaries packed with two different RP18 stationary phases (SP). The best results concerning resolution and efficiency were achieved using the SP where free silanol groups were not present. As expected, this latter SP proved to be very efficient and symmetry factors were observed mainly in the case of the more retained analytes. Baseline resolution of all studied basic compounds was achieved with the Cogent bidentate C18 silica phase (CBC18) eluting analytes at 800 nL/min with a mobile phase containing 500 mM ammonium acetate pH 4.5-water-methanol (1:8:91, v/v/v). The separated basic compounds were revealed using on-column UV detector at 205 nm and electrospray-ion-trap mass spectrometer (ESI-MS). The packed capillary was connected to the MS through a commercial sheath liquid interface or a sheathless nano-spray interface and in both cases the sensitivity was studied and the results compared. Limit of detection (LOD) as low as 0.1 ng/mL was measured for nadolol using the sheathless nano-spray interface and the capillary column packed with the CBC18 stationary phase.  相似文献   

3.
A direct injection analysis by high-performance liquid chromatography has been developed for oxytetracycline in serum of animals and fish. A Hisep shielded hydrophobic phase column (15 cm x 4.6 mm I.D.) and a mobile phase of methanol-0.2 M oxalic acid (10:90, v/v, pH 7.0) with ultraviolet detection at 360 nm were used. The standard calibration curves in serum of chicken, hog, cattle and rainbow trout were linear over the range 0.1-20 micrograms/ml. The recoveries of oxytetracycline from all serum samples determined at two different concentrations (0.5 and 2.0 micrograms/ml) were 88-103%. The detection limit was 0.05 micrograms/ml for every serum sample.  相似文献   

4.
《Analytical letters》2012,45(3):424-436
Abstract

High‐performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of nadolol in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 230 and 300 nm, respectively. A mobile phase composed by acetonitrile‐water containing 0.1% triethylamine (15∶85 v/v) and pH adjusted to 4.6 with formic acid was used. The UVDS method was performed taken a signal at 279.5 nm. The correlation coefficient (r) obtained for both methods was 0.9999. The proposed methods are simple, precise, accurate, and can be used in routine analysis.  相似文献   

5.
A procedure was developed for the determination of caffeine and theophylline using a C18 column (5 microm, 250 mm x 4.6 mm) and micellar liquid chromatography using hybrid mobile phases containing sodium dodecyl sulfate (SDS) and propanol, butanol or pentanol as modifiers. Detection was performed with a variable wavelength UV-vis detector at 272 nm. After the application of an interpretative strategy for the selection of the optimimum mobile phase, caffeine and theophylline can be resolved and determined in serum samples by direct injection, using a mobile phase made up of 50 mM SDS-2.5% (v/v) propanol-10 mM KH2PO4, pH 7, with an analysis time below 5 min. Calibration was linear in the range 0.05 to 50 microg mL(-1) with r > 0.999. The statistical evaluation of the method was examined by performing intra-day (n = 6) and inter-day calibration (n = 7) and was found to be satisfactory, with highly accurate and precise results. The proposed method was suitably validated and applied to the determination of caffeine and theophylline in serum samples of patients treated with bronchodilators.  相似文献   

6.
A simple and sensitive high-performance liquid chromatographic method for a routine assay of gliclazide in serum is described. Serum samples spiked with glibenclamide (internal standard) were applied to Bond Elut C18 cartridges. After washing with phosphate buffer (pH 7.5) and water, the cartridge was eluted with 60% methanol. The eluate was evaporated to dryness. The residue was dissolved in methanol and injected onto an octadecyl silica column (5 microns, 150 mm x 4.6 mm I.D.). The mobile phase was 0.04 M potassium dihydrogenphosphate (pH 4.6)-acetonitrile-isopropyl alcohol (5:4:1, v/v). Ultraviolet detection at 227 nm was used. The minimum detectable level of gliclazide was 20 ng/ml.  相似文献   

7.
For the determination of khellin in urine and serum, fluorometry using HPLC-postcolumn photoirradiation has been developed. Khellin and visnagin of similar structure were separated on a column of Capcell Pak C8. The mobile phase consisted of 40%(v/v) ethanol containing 75 mmol l(-1) H2O2. The postcolumn reagent, 70 mmol l(-1) KH2PO4-NaOH buffer (pH 12.7) containing 50%(v/v) ethanol, were mixed with the mobile phase, which was irradiated with ultraviolet light to induce fluorescence. The fluorescence was monitored with excitation at 378 nm and emission at 480 nm. The calibration graph for khellin was linear over the range of 65 - 2620 ng ml(-1) using an injection volume of 20 microl. The pretreatment of the urine or serum samples consisted of diluting steps or deproteinizing steps using perchloric acid, respectively.  相似文献   

8.
Jiang M  Qin F  Xiong Z  Zhang S  Pan L  Li F 《色谱》2011,29(11):1137-1140
以纤维素三-(3,5-二甲基苯基氨基甲酸酯)为手性固定相(Lux Cellulose-1),建立了在正相色谱条件下直接分离盐酸川丁特罗对映体的高效液相色谱法。考察了乙醇、异丙醇等有机改性剂,三氟乙酸、二乙胺等流动相添加剂和柱温对对映体分离的影响。结果显示,酸性和碱性添加剂对对映体分离的影响最为显著: 添加二乙胺时两对映体无分离趋势;添加三氟乙酸时对映体保留强,且分离趋势明显;而同时添加三氟乙酸和二乙胺则两对映体分离显著改善,分离度可达4.0。优化后的色谱条件: 色谱柱为Lux Cellulose-1手性柱(250 mm×4.6 mm, 5 μm),流动相为正庚烷-乙醇-三氟乙酸-二乙胺(88:12:0.3:0.05, v/v/v/v),流速为1.0 mL/min,紫外检测波长为246 nm,柱温为25 ℃。该方法简便,快速,可用于左旋盐酸川丁特罗原料中右旋异构体杂质的检查。  相似文献   

9.
This work presents an HPLC method for the quantification of free amino acids in lyophilized protein fraction from shrimp waste hydrolysate which is obtained by acid lactic fermentation and analyzed using pre-column derivatization with 9-fluorenylmethyl-chloroformate. The amino acids were separated in a Hypersil ODS 5 microm column (250 mm x 4.6 mm) at 38 degrees C. The mobile phase was a mixture of phase A: 30 mM ammonium phosphate (pH 6.5) in 15:85 (v/v) methanol/water; phase B: 15:85 (v/v) methanol/water; and phase C: 90:10 (v/v) acetonitrile/water, with flow rate 1.2 ml/min. Fluorescence detection was used at an excitation wavelength of 270 nm and an emission wavelength of 316 nm. Method precisions for the different amino acids were between 4.4 and 7.1% (relative standard deviation, RSD); detection limits were between 23 and 72 ng/ml; and the recoveries were between 89.0 and 95.0%. The amino acid present at the highest concentration was tyrosine.  相似文献   

10.
A normal phase (NP) high performance liquid chromatography (HPLC) method was developed for analysis of paclitaxel incorporated in poly(sebacic-co-ricinoleic acid), a lipophilic polymer matrix utilized for preparation of an injectable formulation for the localized delivery of paclitaxel. Thin layer chromatography experiments revealed that separation of paclitaxel from the polymer is dependent on the eluting strength (solvent strength) of the mobile phase. The HPLC system consists of a Purospher STRAR Si analytical HPLC column (5 microm, 250mm x 4mm, Merck), and 1-2.5% (v/v) methanol in dichloromethane as the mobile phase. Detection was by UV absorbance at 240 and 254 nm. The effect of the mobile phase composition on paclitaxel retention, peak shape and column efficiency, and the influence of the sample loading on the shape of the paclitaxel peak were studied. The mobile phases used for the chromatography consisted of 1.5% (v/v) methanol in dichloromethane. Paclitaxel was determined in the formulation and in the samples from degradation studies using UV detection at a wavelength of 254 nm. UV detection at 240 nm has advantages for following polymer matrix degradation products due to higher detector response at this wavelength. The utility of the proposed NP HPLC approach was demonstrated by assessment of intra- and inter-batch content uniformity, and by the determination of paclitaxel content after 7 and 60 days exposure of the paclitaxel-loaded polymer matrix to in vitro and in vivo degradation.  相似文献   

11.
An enantioselective liquid chromatographic assay for the simultaneous determination of the S-(+) and R-(-) enantiomers of the monohydroxylated metabolite of oxcarbazepine in human plasma is described. The metabolite is the active principle. The method is based on the extraction of plasma with diethyl ether-dichloromethane (2:1, v/v), separation of the organic phase, evaporation of the solvent and dissolution of the residue in the mobile phase. The two enantiomers were resolved on a Chiralcel OD (250 mm x 4.6 mm I.D.) high-performance liquid chromatographic column. The separation was achieved by isocratic elution with n-hexane-2-propanol (77:23, v/v). The flow-rate of the mobile phase was 1.0 ml/min and the two enantiomers were detected by ultraviolet absorbance at 210 nm. The analytical method is suitable for the quantitative and simultaneous determination of the two enantiomers in plasma at concentrations down to 0.4 mumol/l after administration of oxcarbazepine.  相似文献   

12.
Abstract

A high-performance liquid chromatography was developed for simultaneous determinations of Cinobufagin (CB) and its metabolites deacetylcinobufagin, 3-epideacetyl-cinobufagin, 3-ketodeacetylcinobufagin, 3-epicinobufagin and 3-ketodeacetylcinobufagin in serum and urine of rat. The biological samples were extracted with diethylether-ethylacetate (4:1v/v) in the presence of bufalin as the internal standard. Recoveries for CB and all other compounds were in the range of 80.8%–100.2%. Excellent resolution was obtained by reversed-phase chromatography on a 4.6 mm I.D.×150 mm ODS column using acetonitrile:water (50:50 v/v) as the mobile phase at a flow-rate of 0.7 ml/min with UV detector at 300 nm. Standard curve data revealed linearity over a range of 10–500 ng per ml serum and urine. The detection limits of CB and its metabolites were less than 10 ng/ml. Coefficients of variation for the analysis were less than 10. CB and its some metabolites were observed in  相似文献   

13.
Summary This work focuses on the separation and identification of p-tert butyl calix[4]arene derivatives. An isocratic mixture of 65% (v/v) acetonitrile and 35% (v/v) water with 0.1% (v/v) phosphoric acid was used as the mobile phase. A Bio-Rad Bio-Sil ODS-5S (250 mm×4 mm) column was used as the stationary phase with UV detection of the analytes at 274 nm. The reversed-phase high performance liquid chromatographic method which was developed provided baseline separation of five p-tertbutyl calix[4]arene derivatives in twenty minutes.  相似文献   

14.
卢铁刚  杨茂俊 《色谱》2007,25(6):830-833
建立了帕罗西汀及其中间体的高效液相色谱手性拆分分析方法。选用C18柱(4.6 mm×250 mm,5 μm),流动相为0.1%磷酸-甲醇(体积比为65∶35,含0.38 g/L羧甲基-β-环糊精,以三乙胺调pH 7.2),柱温25 ℃,检测波长210 nm。结果表明,帕罗西汀及其中间体HFP的对映异构体在30 min内同时得到了基线分离,该法与手性固定相法相比具有分离效果更好的优势。  相似文献   

15.
A new high-performance liquid chromatographic (HPLC) method with fluorescence detection is described for the direct determination of four serum 17-oxosteroid sulphates. Each serum sample was deproteinated with methanol, the methanol was evaporated and 17-oxosteroid sulphates in the residue were extracted with benzene as ion pairs in the presence of tetrapentylammonium ion. The ion pairs were labelled with dansylhydrazine and the hydrazones were separated by HPLC on a Capcell-Pak C8 (silicone polymer-coated silica gel modified with octyl groups) reversed-phase column using methanol-0.5% (w/v) sodium acetate-50% (v/v) acetic acid (57:42:1, v/v/v) as the mobile phase. The eluent was monitored with a fluorometric detector at an excitation wavelength of 330 nm and an emission wavelength of 540 nm.  相似文献   

16.
高效液相色谱手性固定相法拆分阿折地平对映体   总被引:2,自引:0,他引:2  
张恺  薛娜  李林  李凡  杜玉民 《色谱》2010,28(2):215-217
建立了阿折地平对映体的高效液相色谱拆分方法。采用Chiralpak AD-H (250 mm×4.6 mm, 5.0 μm, Daicel公司)手性色谱柱在正相条件下直接拆分阿折地平对映体,考察了固定相种类、流动相组成及柱温等对阿折地平对映体分离的影响。确定了最佳的拆分条件: 流动相为正己烷-异丙醇(90:10, v/v),流速为0.8 mL/min,检测波长为254 nm;柱温为20 ℃;在此条件下阿折地平对映体的分离度为3.3。该法简单快速,重现性好。  相似文献   

17.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

18.
A method is proposed for the determination of vitamin K1 concentration in blood serum using HPLC on a Gemini C18 (250 mm × 4.6 mm ID, 5 μm) column and elution with a methanol–acetonitrile–dichloromethane (45 : 50 : 5, v/v) mobile phase at a flow rate of 1 mL/min and detection at 248 nm. The limit of detection for the vitamin is 0.5 ng/mL and relative error is 19%. The volume of sample in the column is 100 μL. The method has been applied to the evaluation of vitamin K1 deficit in a human body in medical practice.  相似文献   

19.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

20.
Micellar liquid chromatography with sodium dodecyl sulphate or Brij-35 as surfactants in the mobile phase was evaluated and compared with reversed phase liquid chromatography using conventional acetonitrile-water eluents for the separation and determination of desferrioxamine (DFO) and its complexes with aluminium (AIDFO) and iron (FeDFO) in uremic serum. Reversed phase liquid chromatography proved to be superior in terms of sensitivity and selectivity. The three solutes investigated were separated with a mobile phase of 13% (v/v) acetonitrile/phosphate buffer (5 mM, pH = 3.5) on a C(18) column and detected by ultraviolet absorption at 210 nm (DFO) and 220 nm (AlDFO and FeDFO). Limits of detection of 0.1 mug ml(-1) and relative standard deviation of 3-4% were obtained. The recovery from serum samples after ultramicrofiltration was around 90%. The method was applied to the determination of DFO, AlDFO and FeDFO in uremic serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号