1.
Susceptibility artifacts due to metallic prostheses are a major problem in clinical magnetic resonance imaging. We theoretically and experimentally analyze slice distortion arising from susceptibility differences in a phantom consisting of a stainless steel ball bearing embedded in agarose gel. To relate the observed image artifacts to slice distortion, we simulate images produced by 2D and 3D spin-echo (SE) and a view angle tilting (VAT) sequence. Two-dimensional SE sequences suffer from extreme slice distortion when a metal prosthesis is present, unlike 3D SE sequences for which--since slices are phase-encoded--distortion of the slice profile is minimized, provided the selected slab is larger than the region of interest. In a VAT sequence, artifacts are reduced by the application of a gradient along the slice direction during readout. However, VAT does not correct for the excitation slice profile, which results in the excitation of spins outside the desired slice location and can lead to incorrect anatomical information in MR images. We propose that the best sequences for imaging in the presence of a metal prosthesis utilize 3D acquisition, with phase encoding replacing slice selection to minimize slice distortion, combined with excitation and readout gradient strengths at their maximum values.  相似文献   

2.
An MR imaging technique has been developed producing head and body images of diagnostic quality in only a few seconds acquisition time. The Fourier type imaging technique uses excitation with relatively small excitation angels, echoes produced by gradient inversion, and extremely fast profile repetition. A typical result at 0.5 T is an artifact-free head image of 128 x 128 resolution, 10 mm slice thickness in an acquisition time of 2 seconds.  相似文献   

3.
In previous work we have shown that wavelet encoding spectroscopic imaging (WE-SI) reduces acquisition time and voxel contamination compared to the standard Chemical Shift Imaging (CSI) also known as phase encoding (PE). In this paper, we combine the wavelet encoding method with parallel imaging (WE-PI) technique to further reduce the acquisition time by the acceleration factor R, and preserve the spatial metabolite distribution. Wavelet encoding provides results with a lower signal-to-noise ratio (SNR) than the phase encoding method. Their combination with parallel imaging, introduces an intrinsic SNR reduction. The rate of SNR reduction is slower in wavelet encoding with PI than PE with parallel imaging (PE-PI). This is due to the fact that in WE-PI, the SNR reduction is a function of the acceleration factor R and the voxel number N, whereas in PE-PI it is a function of the acceleration factor R only.  相似文献   

4.
磁共振成像(MRI)无创无害、对比度多、可以任意剖面成像的特点特别适合用于心脏成像,却因扫描时间长限制了其在临床上的应用.为了解决心脏磁共振电影成像屏气扫描时间过长的问题,该文提出了一种基于同时多层激发的多倍加速心脏磁共振电影成像及其影像重建的方法,该方法将相位调制多层激发(CAIPIRINHA)技术与并行加速(PPA)技术相结合,运用到分段采集心脏电影成像序列中,实现了在相位编码方向和选层方向的四倍加速,并使用改进的SENSE/GRAPPA算法对图像进行重建.分别在水模以及人体上进行了实验,将加速序列图像与不加速序列图像进行对比,结果验证了重建算法的有效性,表明该方法可以在保障图像质量以及准确测量心脏功能的前提下成倍节省扫描时间.  相似文献   

5.
近年来,为提高磁共振成像(MRI)信号信噪比(SNR)、缩短成像时间,同时多层成像技术受到了极大的关注.为了实现同时多层的选择性激发,现有的多层成像序列大多使用组合射频(RF)脉冲,该脉冲可包含多个独立的幅值相同相位不同的简单脉冲,由于其采用简单的线性叠加方法,该类脉冲射频功率随脉冲数量呈现平方增长,因而应用受限.针对这一问题,基于自旋动力学和优化控制原理,本文提出了一种针对同时多层MRI的选择性射频脉冲的数值优化方法,该方法充分运用射频脉冲的调控机制,获得优化脉冲,并配合层选梯度,可实现任意层厚、层间距、层数的同时高效选择性激发.最后,通过数字模体的同时多层模拟成像实验验证了优化脉冲的有效性.  相似文献   

6.
Rapid MR imaging techniques either deposit high amounts of radio frequency power or require powerful gradient systems with high slew rates, which might not be available on conventional scanners. QUEST provides a fast imaging method with scan times of the order of hundreds of milliseconds and avoids these problems at the cost of low signal-to-noise ratios (SNR). In this work, QUEST was optimized with regard to image quality and measuring time. With the use of a Hybrid QUEST technique, that refocuses the image echoes several times, a spatial resolution of 1.9 mm x 1.6 mm x 5 mm was achieved. By acquiring both the necessary correction data and the image information in a single echo train, the Hybrid QUEST technique was implemented as a true single-shot measurement with a total scan time of 190 ms. Optimization of the excitation flip angles and the amplitude and phase correction methods for image reconstruction resulted in an improved SNR of 53.7 in the white matter of the human head for a 10 mm slice thickness at 1.5 T. In contrast to echo planar imaging techniques, no image distortions were observed with Hybrid QUEST in anatomic regions with many tissue interfaces.  相似文献   

7.
We introduce an accelerated gradient echo (GRE) sequence combining simultaneous multislice excitation (SMS) with echo-shifting technique for high spatial resolution blood oxygen level dependent (BOLD) functional MRI (fMRI). The simulation was conducted to optimize scan parameters. To validate the feasibility of the proposed technique, the visual and motor task experiments were performed at 7.0 Tesla (T). The single-shot EPI sequence was also applied in comparison with the proposed technique. The simulation results showed that an optimized flip angle of 9° provided maximal BOLD contrast for our scanning scheme, allowing low power deposition and SMS acceleration factor of 5. Additionally, parallel acquisition imaging with acceleration factor of 2 was utilized, which allowed a total acceleration factor of 10 in volunteer study. The experiment results showed that geometric distortion-free BOLD images with voxel size of 1.0 × 1.0 × 2.5 mm3 were obtained. Significant brain activation was identified in both visual and motor task experiments, which were in accordance with previous investigations. The proposed technique has potential for high spatial resolution fMRI at ultra-high field because of its sufficient BOLD sensitivity as well as improved acquisition speed over conventional GRE-based techniques.  相似文献   

8.
Three-dimensional (3D) twisted projection imaging (TPI) trajectory has a unique advantage in sodium (23Na) imaging on clinical MRI scanners at 1.5 or 3 T, generating a high signal-to-noise ratio (SNR) with a short acquisition time (∼10 min). Parallel imaging with an array of coil elements transits SNR benefits from small coil elements to acquisition efficiency by sampling partial k-space. This study investigates the feasibility of parallel sodium imaging with emphases on SNR and acceleration benefits provided by the 3D TPI trajectory. Computer simulations were used to find available acceleration factors and noise amplification. Human head studies were performed on clinical 1.5/3-T scanners with four-element coil arrays to verify simulation outcomes. In in vivo studies, proton (1H) data, however, were acquired for concept–proof purpose. The sensitivity encoding (SENSE) method with the conjugate gradient algorithm was used to reconstruct images from accelerated TPI-SENSE data sets. Self-calibration was employed to estimate coil sensitivities. Noise amplification in TPI-SENSE was evaluated using multiple noise trials. It was found that the acceleration factor was as high as 5.53 (corresponding to acceleration number 2×3, ring-by-rotation), with a small image error of 6.9% when TPI projections were reduced in both polar (ring) and azimuthal (rotation) directions. The average noise amplification was as low as 98.7%, or 27% lower than Cartesian SENSE at that acceleration factor. The 3D nature of both TPI trajectory and coil sensitivities might be responsible for the high acceleration and low noise amplification. Consequently, TPI-SENSE may have potential advantages for parallel sodium imaging.  相似文献   

9.
The shortest possible delay (Td) between slice selection and data acquisition is important for producing high quality 31P spectra. In single slice multivoxel spectroscopic imaging, conventional excitation using sinc-shaped rf pulses within typical gradient limitations can have values of Td that lead to significant spectral distortion and loss of signal. Truncated sinc excitation, which ends the excitation close to the center of the main rf lobe has been suggested for MR angiographic applications to produce short values of Td. In this work, the slice profiles, spectral signal-to-noise ratio (SNR) and spectral distortions are compared using the minimum delay achievable on a commercial MRI system for conventional 'sinc' rf excitation and truncated sinc excitation. Slice profiles are calculated using the Bloch equations and measured with a phantom. SNR and spectral distortions are evaluated from whole slice spectra on a human volunteer. On an MRI system with 1 G/cm gradients (0.5 msec risetime), for a 2.5-cm slice at 31P frequencies, conventional excitation can be adjusted to achieve Td = 2.5 msec while truncated sinc excitation yields Td = 1.5 msec. The truncated sinc excitation's shorter value of Td leads to much smaller spectral distortions, but its slice profile has "dispersive tails" which increase as more of the rf is truncated. Slice profile corrected SNR for the beta-ATP peak of 31P on a human volunteer is equivalent for both sequences while, qualitatively, in the PDE region the truncated sinc approach has improved SNR.  相似文献   

10.
Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA), which are both applied to a gradient-echo sequence. Both methods were tested on 12 patients with coronary artery disease. The order of perfusion sequences was inverted in every other patient. Image acquisition was started during the administration of a contrast bolus followed by a 20-ml saline flush (3 ml/s), and the next perfusion was started at least 15 min thereafter using an identical bolus. An acceleration rate of 2 was used in both methods, and acquisition was performed during breath-holding. Significantly higher SNR, CNR and image quality were obtained with GRAPPA images than with TSENSE images. GRAPPA, however, did not yield a higher CNR when applied after the second bolus. GRAPPA perfusion imaging produced larger differences between subjects than did TSENSE. Compared to TSENSE, GRAPPA produced significantly better CNR on the first bolus. More consistent SNR and CNR were obtained from TSENSE images than from GRAPPA images, indicating that the diagnostic value of TSENSE may be better.  相似文献   

11.
T2?-weighted blood oxygen level-dependent functional magnetic resonance imaging is adversely affected by susceptibility-induced field gradients in brain regions adjoining air interfaces that cause image distortion and signal dropout. Reducing slice thickness diminishes signal dropout but is accompanied by reduced signal-to-noise ratio (SNR). This study proposes simultaneous excitation of subslices with total width equal to the desired slice thickness, employing alternating Hadamard-encoded radiofrequency pulses coupled with incoherent addition of the subslices to achieve reduction of through-plane dephasing with minimal SNR loss but at the expense of a reduction in temporal resolution. Using a sensory task and hypercapnic challenge with breathholding (BH), results with two subslices per slice and a twofold reduction in temporal resolution show improved activation relative to a conventional acquisition. Average (eight subjects) T-scores in the BH task increased by 16% (P<.0003), and activation extent increased by 12% (not significant). In frontal brain regions, significant improvements in BH activation extent (11.4%, P<.05) and T-scores (18%, P<.0002) were demonstrated. Higher temporal resolution can be achieved by tradeoff of SNR.  相似文献   

12.
Pediatric oncology patients with large metallic prostheses were imaged with one of two MR imaging techniques: 1) the "tilted view-angle" technique, 2) or a higher readout bandwidth technique. The tilted view-angle method uses an additional gradient in the slice selection direction during readout. The high bandwidth technique increases the readout bandwidth and shortens the echo time (TE). High bandwidth and short echo times were implemented in both T(1)-weighted (T(1)W) turbo spin echo and turbo short tau inversion recovery (STIR) sequences. Both imaging techniques reduced the size of metal-induced image artifacts. The tilted view-angle method reduced the artifact to a greater degree but had inherent shortcomings. The reformatted images were blurred and shifted. The area of interest was often moved outside of the field of view, unless parameters were adjusted on the basis of a pre-scan calculation. The high readout bandwidth, short echo technique required no special preparation and reduced metal artifacts without image blurring. The combination of high-bandwidth, shorter echo turbo STIR and T(1)W turbo spin echo sequences with subtraction of pre- from post-contrast images allowed effective fat suppression without local field inhomogeneity affects. This greatly improved our ability to evaluate suspected disease near metallic implants in pediatric cancer patients.  相似文献   

13.
An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.  相似文献   

14.
The simultaneous dual-frequency operation of a resonant photoacoustic gas sensor based on the differential mode excitation photoacoustic (DME-PA) technique is presented. The DME-PA method uses the excitation of two different modes in a resonant photoacoustic cell and the gas concentration is derived from the amplitude ratio of these acoustic modes. With the simultaneous dual-frequency excitation, the amplitude ratio needed by the DME-PA technique is obtained instantaneously, in contrast to the sequential modulation scheme where additional time delays are introduced by changing the modulation frequency. For a given excitation power reaching the photoacoustic cell, and a total acquisition time longer than 7 s, the simultaneous modulation scheme provides an improved measurement uncertainty compared to the sequential scheme. The proposed sensor allows measuring water vapour with a ±150 ppmV uncertainty using current-modulated near-infrared LEDs and a 15 s total acquisition time.  相似文献   

15.
马亚军  李莎  高嵩 《中国物理 B》2017,26(11):118701-118701
Controlled aliasing in parallel imaging results in higher acceleration(CAIPIRINHA) for simultaneous multislice imaging has been proposed recently, which combines multiband excitation and phase cycling techniques to reduce scan time and improve subsequent imaging reconstruction. In this work, the total variation(TV) regularization method is used to further improve CAIPIRINHA. The TV regularization uses an edge-preserving prior, which establishes a relationship between neighboring pixels for image reconstruction. It reduces artifacts and suppresses noise amplification simultaneously.The results are presented with a standard eight-channel head coil with an acceleration factor of 4, where the TV-regularized CAIPIRINHA generates an improved reconstruction as compared with a typical nonregularized CAIPIRINHA.  相似文献   

16.
At high magnetic field, B(1)(+) non-uniformity causes undesired inhomogeneity in SNR and image contrast. Parallel RF transmission using tailored 3D k-space trajectory design has been shown to correct for this problem and produce highly uniform in-plane magnetization with good slice selection profile within a relatively short excitation duration. However, at large flip angles the excitation k-space based design method fails. Consequently, several large-flip-angle parallel transmission designs have recently been suggested. In this work, we propose and demonstrate a large-flip-angle parallel excitation design for 90 degrees and 180 degrees spin-echo slice-selective excitations that mitigate severe B(1)(+) inhomogeneity. The method was validated on an 8-channel transmit array at 7T using a water phantom with B(1)(+) inhomogeneity similar to that seen in human brain in vivo. Slice-selective excitations with parallel RF systems offer means to implement conventional high-flip excitation sequences without a severe pulse-duration penalty, even at very high B(0) field strengths where large B(1)(+) inhomogeneity is present.  相似文献   

17.
Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the behavior of a magnetic field gradient waveform in an MR scanner. The method employs excitation of a thin slice, followed by application of the studied gradient and simultaneous FID acquisition. Measurements of different gradient waveforms were performed with a spherical phantom filled with doped water and positioned at the isocenter of the gradient set. The presented experiments demonstrate the capability of the technique to measure different gradient waveforms with an estimated error of less than 200 microT/m.  相似文献   

18.
Sodium MR imaging is considered to provide clinically important information about the human body that is not achievable by hydrogen-based approaches. However, due to the low natural abundance in biological tissues, sodium signals usually lead to low spatial resolution, low SNR, and long acquisition times compared to conventional 1H imaging, even using well-adapted surface coils. For our study, a volume coil was designed with nearly homogeneous excitation/receive characteristics and a suitable geometry fitting the human torso. A sufficient penetration throughout the entire thorax, abdomen, or pelvis is provided allowing for sodium imaging of the kidneys, the liver with gall bladder, or the myocardium. All measurements were performed on a 1.5 T whole body scanner using a spoiled 3-D gradient echo sequence. Imaging parameters TE, TR, and readout bandwidth were optimized for sensitive recording of the sodium component with slow transverse relaxation. Nonselective RF excitation pulses with a duration of 2.5 ms and rectangular shape were applied to avoid SAR problems. Narrow receiver bandwidth and excitation near the Ernst angle provided clinically practicable examinations with measuring times of less than 15 min at a spatial resolution of 8 x 8 x 8 mm3. Under these conditions, SNR of 11 for the kidneys and vertebral disks, 9 for the spinal canal, and 6 for the liver was achieved. A special 3-D spin echo sequence was used to determine T2, times which resulted to 15.3 +/- 1.1 ms for liver, 27.7 +/- 7.2 ms for kidneys, and 24.0 +/- 4.7 ms for the content of the spinal canal.  相似文献   

19.
A method was implemented and tested that allows the simultaneous acquisition of magnetic resonance 2D slice selective perfusion and 3D angiographic data during a single bolus injection of a contrast agent. High quality contrast-enhanced perfusion images and angiograms of the lung, kidney and heart were obtained in healthy volunteers. Combined perfusion and angiography provided additional information with an acceptable increase in acquisition time. No image artifacts were attributed to the technique. The combined information may be useful in detecting, as well as characterizing, vascular abnormalities.  相似文献   

20.
A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180° out-of-phase, respectively, and generates automatically separate water and fat images for each slice. The image reconstruction algorithm uses an improved and robust region-growing scheme for phase correction and achieves consistency in water and fat identification between different slices by exploiting the intrinsic correlation between the complex images from two neighboring slices. To further lower the acquisition time to that of a regular fast spin echo acquisition with a single signal average, we combined the fast 2PD technique with sensitivity encoding (SENSE). Phantom experiments show that the fast 2PD and SENSE are complementary in scan efficiency and signal-to-noise ratio (SNR). In vivo data from scanning of clinical patients demonstrate that T2-weighted imaging with uniform and consistent fat separation, including breath-hold abdominal examinations, can be readily performed with the fast 2PD technique or its combination with SENSE.  相似文献   