首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
This article describes the comparison of different versions of an easy, rapid and low-cost sample preparation approach for the determination of pesticide residues in fruits and vegetables by concurrent use of gas and liquid chromatography (GC and LC) coupled to mass spectrometry (MS) for detection. The sample preparation approach is known as QuEChERS, which stands for “quick, easy, cheap, effective, rugged and safe”. The three compared versions were based on the original unbuffered method, which was first published in 2003, and two interlaboratory validated versions: AOAC Official Method 2007.01, which uses acetate buffering, and European Committee for Standardization (CEN) Standard Method EN 15662, which calls for citrate buffering. LC–MS/MS and GC–MS analyses using each method were tested from 50 to 1000 ng/g in apple–blueberry sauce, peas and limes spiked with 32 representative pesticides. As expected, the results were excellent (overall average of 98% recoveries with 10% RSD) using all 3 versions, except the unbuffered method gave somewhat lower recoveries for the few pH-dependent pesticides. The different methods worked equally well for all matrices tested with equivalent amounts of matrix co-extractives measured, matrix effects on quantification and chemical noise from matrix in the chromatographic backgrounds. The acetate-buffered version gave higher and more consistent recoveries for pymetrozine than the other versions in all 3 matrices and for thiabendazole in limes. None of the versions consistently worked well for chlorothalonil, folpet or tolylfluanid in peas, but the acetate-buffered method gave better results for screening of those pesticides. Also, due to the recent shortage in acetonitrile (MeCN), ethyl acetate (EtOAc) was evaluated as a substitute solvent in the acetate-buffered QuEChERS version, but it generally led to less clean extracts and lower recoveries of pymetrozine, thiabendazole, acephate, methamidophos, omethoate and dimethoate. In summary, the acetate-buffered version of QuEChERS using MeCN exhibited advantages compared to the other tested methods in the study.  相似文献   

2.
Sulphadimethoxine is metabolized in humans by N1-glucuronidation and by N4-acetylation. Sulphadimethoxine-N1-glucuronide can be measured by the direct high-performance liquid chromatographic analysis and without enzymic deglucuronidation. The N1-glucuronide can be measured by an isocratic as well as by a gradient mobile phase. The group contribution of the N1-glucuronide moiety to the capacity factor is a reduction of 0.24 in the isocratic system and 0.55 in the gradient system. N4-Acetylation increases the capacity factor by a factor 1.4 in the isocratic system and by 1.06 in the gradient system.  相似文献   

3.
A simple and rapid sample preparation method for the determination of chloramphenicol in swine muscle tissue at the 10 micrograms/kg level is described. The method comprises sonication-aided extraction with ethyl acetate, addition of hexane to the extract and cleaning up and concentration of the extract on a small column packed with silica gel. Analysis was performed by high-performance liquid chromatography on a ChromSep column with ChromSpher C8 using acetonitrile-sodium acetate buffer as the mobile phase. Detection was performed at 280 nm. Mean recoveries from spiked muscle samples were 79 +/- 3% (10-50 micrograms/kg). The distribution of chloramphenicol in different muscle and fatty tissues from a pig to which a single dose of chloramphenicol was administered was also investigated.  相似文献   

4.
A liquid chromatographic method with diode array detection (DAD) has been developed for the analysis of the antiepileptic agent lamotrigine (LTG) and its metabolites, lamotrigine 2-N-glucuronide and 2-N-methylated in plasma samples. The analytes were separated on a C8 RP column, using a mobile phase composed of methanol and a 0.45 mM, pH 3.5 phosphate buffer containing 0.17% triethylamine (24:76 v/v). Melatonin was used as the internal standard (IS). The DAD detector was set at 220 nm for the detection of all the analytes. A simple protein precipitation with methanol guaranteed high extraction yield values (>90%) and good purification from matrix interference. Good linearity was obtained in the 0.1-15.0 microg/mL range for LTG and lamotrigine 2-N-glucuronide and in the 0.1-2.0 microg/mL range for lamotrigine 2-N-methylated. The analytical method was validated in terms of precision, extraction yield, and accuracy. These assays gave RSD% values for precision always lower than 4.3% and mean accuracy higher than 80%. The method seems to be suitable for the analysis of plasma samples from patients treated with Lamictal.  相似文献   

5.
This work describes a new method for the quantitation of trace amounts of sulfamethazine (SMZ) and its main metabolite, N4-acetylsulfamethazine (Ac-SMZ), in swine urine, using high-performance liquid chromatography (HPLC) tandem mass spectrometric analysis of crude urine after addition of internal standard and simple dilution with water. The aim was to determine whether residues of this sulfamidic drug, normally administered to swine in order to prevent infectious diseases, were present in urine at levels lower than those permitted by regulatory authorities before human consumption (EU Project SMT, contract number CT 96-2092). A 10 microL volume of diluted urine was injected into a very short, narrow-bore chromatographic column (Zorbax SB-C18 2.1 i. d. x30 mm length, 3.5 microm pore size). Elution of the analytes of interest was achieved in less than seven minutes using a rapid gradient (from 20 to 80% methanol in 3 minutes). Either a PE Sciex API 365 triple quadrupole (QqQ), operated in the selected reaction monitoring (SRM) mode, or a Finnigan LCQ ion trap (IT) mass spectrometer, operated in narrow-range product ion scan, was used as the final detector. Electrospray (ESI) was used as the ionization technique. A comparison of the two tandem mass spectrometers was performed by analyzing the same set of test samples, at three concentration levels, on three different days. Linearity of responses of the calibration standards, intra- and inter-assay precision of the samples, specificity and limits of detection were evaluated for both systems. Both the QqQ and the IT instrument was suitable for rapid, sensitive and specific determination of the analytes, although the overall performance of the QqQ was slightly superior in terms of linearity, precision and sensitivity.  相似文献   

6.
Summary Acetonitrile can be salted-out from aqueous solution by adding tetrabutylammonium perchlorate. This phase separation method has been used for the extraction of the Fe(III)-4,7-diphenylphenanthroline complex into acetonitrile followed by direct injection onto an ODS column. The Fe complex is separated by using 9:1 acetonitrile/water as a mobile phase. The proposed reversed-phase high-performance liquid chromatography has been applied to the determination of Fe in serum.  相似文献   

7.
《Mendeleev Communications》2019,29(5):592-594
  1. Download : Download high-res image (68KB)
  2. Download : Download full-size image
  相似文献   

8.
Due to the lack of one universally applicable and commonly used reference method, sample preparation in isoflavone (IF) analysis has been performed by many different methods which renders comparison and quality assessment of published IF contents in foodstuffs difficult.In the present work, the impact of different experimental parameters on the IF concentrations determined in soybeans, tofu, soy drink and textured vegetable protein by different extraction and hydrolysis methods was assessed and IF contents obtained by optimized orthogonal methods were compared. Chromatographic analysis was performed by HPLC-UV-ESI-MS. If possible sources of error - which are also pointed out in this work - are avoided, IF contents obtained by extraction, acid-, base- and enzymatic hydrolysis are similar. However, these sample preparation methods differ in the amount of time, standard compounds and instruments required, ruggedness, and in their applicability to analysis of complex composite samples containing soy as minor ingredient. Enzymatic hydrolysis with Helix pomatia juice after extraction by sonication with first 50, then 80% aqueous acetonitrile in the presence of zinc sulfate heptahydrate and after adjustment to ≤10% organic solvent turned out to be the method of choice if only aglucone equivalent contents are required. The advantages of this method are short chromatographic run times, smallest danger of coelution, lowest achievable limits of quantitation and therefore best suitability for work-up of complex composite samples and that only aglucone standards are needed for quantitation.  相似文献   

9.
10.
Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS < modified QuEChERS < MSPD < modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 microg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21-72% better LOQs than the original method.  相似文献   

11.
A reversed-phase HPLC assay method was developed to determine levels of the drugs trimethoprim, sulfamethoxazole and the N4-acetyl metabolite of the latter in human blood plasma and urine. The organic substances are extracted with ethyl acetate by a single extraction at pH 6.8. The method is rapid, accurate, sensitive and precise and well suited to routine determination of these drugs on patients during clinical pharmacokinetic investigations.  相似文献   

12.
Propofol (2,6-diisopropylphenol) is a short-acting drug with a large volume of distribution and high body clearance. It is suitable both for the induction of anaesthesia by bolus injection and the maintenance of anaesthesia by repeated injections or a continuous infusion. Examining the drug concentration its analysis in whole blood is recommended. This results from the fact that propofol molecules strongly bind with plasma proteins and cellular blood constituents and blood composition variations are observed between individuals or in different disease states or resulting from transfusion etc. In most cases the HPLC analysis follows the extraction of samples. The degree of propofol binding with blood cells can be different, depending on the blood type, and it can change in time, which may affect the results of the analysis. The paper discusses and shows the necessity of blood cell lysis before the extraction procedure. The cell lysis makes possible to determine the total amount of propofol in blood independently of the degree of propofol binding with cellular blood constituents and its changes.  相似文献   

13.
A hazardous-chemical free method for simultaneous determination of sulfamonomethoxine (SMM), sulfadimethoxine (SDM), and their N4-acetyl metabolites in raw milk using shielded column liquid chromatography is developed. The target analytes are extracted by mixing with ethanol-acetic acid (97:3, v/v) followed by centrifugation. The procedure uses a Hisep shielded hydrophobic phase (SHP) column, isocratic elution with 0.1% acetic acid solution (pH 3.1, in water)-ethanol (75:25, v/v), and a photo-diode array detector. Average recoveries from samples spiked at 25-500 ng/ml for each drug were >81% with relative standard deviations within 5%. The limits of quantitation were <25 ng/ml.  相似文献   

14.
This paper describes the use of a quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for extraction and cleanup of 16 pesticide residues of interest in olives and olive oil. These products contain a high lipid content, which can adversely affect pesticide recoveries and harm traditional chromatographic systems. For extraction, the main factors (oil and water content) were studied and optimized in experiments to maximize pesticide recoveries. Dispersive SPE with different sorbents was also investigated to minimize matrix coextractives and interferences. For analysis, a new automated DSI device was tested in GC-MS to avoid nonvolatile coextractives from contaminating the instrument. LC-MS/MS with positive ESI was used for those pesticides that were difficult to detect by GC-MS. The final method was validated for olives in terms of recoveries, repeatabilities, and reproducibilities using both detection techniques. The results demonstrated that the method achieved acceptable quantitative recoveries of 70-109% with RSDs < 20% for DSI-GC-MS and 88-130% with RSDs < 10% for LC-MS/MS, and LOQ at or below the regulatory maximum residue limits for the pesticides were achieved.  相似文献   

15.
The pesticide residues in foods have received increasing attention as one of the most important food safety issues. Therefore, more strict regulations on the maximum residue limits (MRLs) for pesticides in foods have been established in many countries and health organizations, based on the sensitive and reliable analysis methods of pesticide residues. However, the analysis of pesticide residues is a continuing challenge mainly because of the small quantities of analytes as well as the large amounts of interfering substances which can be co-extracted with them, often leading to experimental errors and damage to the analytical instruments. Thus, extensive sample preparation is often required for the pesticide residue analysis for the effective extraction of the analytes and removal of the interferences. This paper focuses on reviewing the recent development in the sample preparation methods for the pesticide residue analysis in foods since 2006. The methods include: liquid-liquid extraction (LLE), supercritical-fluid extraction (SFE), pressurized-liquid extraction (PLE), microwave-assisted extraction (MAE), ultrasound-assisted extraction (UAE), gel permeation chromatography (GPC), solid-phase extraction (SPE), molecularly imprinted polymers (MIPs), matrix solid-phase dispersion (MSPD), solid-phase micro-extraction (SPME), QuEChERS, cloud point extraction (CPE) and liquid phase micro-extraction (LPME), etc. Particularly their advantages, disadvantages and future perspectives will be discussed.  相似文献   

16.
Protein samples should be free of salt and other disturbing agents and have an appropriate concentration to be suitable for two-dimensional (2D) electrophoresis, the principal step of proteomics. To find the most efficient method for sample preparation, we used human plasma and compared four widely applied precipitation methods, using trichloroacetic acid (TCA), acetone, chloroform/methanol and ammonium sulfate, as well as ultrafiltration. Precipitation with TCA and acetone and ultrafiltration resulted in an efficient sample concentration and desalting. We also found that ammonium sulfate fractionation can efficiently remove albumin, which represents more than 50% of plasma proteins.  相似文献   

17.
杨海玉  俞英  郑秀丽 《色谱》2008,26(6):744-748
建立了固相萃取(SPE)-反相高效液相色谱(RP-HPLC)同时测定橙子中痕量辛硫磷、二嗪农有机磷农药残留量的方法。样品经甲醇超声提取、C18固相萃取柱净化后,采用液相色谱柱分离,以乙腈-水(体积比为85∶15)为流动相等度洗脱,于254 nm下紫外检测。结果表明:在0.1~10.0 mg/L和0.4~10.0 mg/L范围内,辛硫磷、二嗪农的质量浓度与峰面积呈良好的线性关系;样品的加标平均回收率为87.3%~102.7%,相对标准偏差(RSD)为0.9%~4.9%。将该分析结果与用基质固相分散法(MSPD)处理样品所得的结果相比较,发现SPE对二嗪农的提取效果较好,而MSPD对辛硫磷的提取效果较好,但两种方法都能较好地净化样品,均能满足残留量的分析要求。  相似文献   

18.
Borszéki J  Halmos P  Gegus E  Kárpáti P 《Talanta》1994,41(7):1089-1093
Pressurized sample preparation devices (High Pressure Asher, Pressurized Microwave Digestion system, compared with a PTFE decomposition vessel) were used to dissolve certified metal alloy samples (steel, copper) for ICP analysis. Based on the results of the analysis it was established that both up-to-date devices can be advantageously applied to quickly and quantitatively dissolve metal alloy samples. To dissolve the samples, two different kinds of acid mixtures (A: nitric and hydrochloric acid; B: nitric and hydrochloric and sulphuric and phosphoric acid) were used. The sample preparation is simpler and less time-consuming than the earlier commonly used methods, sample loss and degree of contamination are also reduced. Steel samples containing tungsten, titanium and niobium (less than 0.5%) can only be analyzed using a mixture of the four acids. By dissolving steel samples in the nitric and hydrochloric acid mixture, the concentration of their most common elements (Cr, Ni, Mn, V, Cu) as well as their S and P content can be determined. Copper alloy samples can be dissolved quickly by the pressurized microwave decomposition device using hydrochloric acid and diluted (1:1) nitric acid.  相似文献   

19.
介绍废弃线路板中有回收价值元素和有害物质分析的采样、制样及检测技术。样品经过分类采样、剪切破碎和高温灰化制样,采用样品全分析或副批混合样分析。通过提高称样量、多次测定求平均值的办法,火试金富集-重量法测定贵金属金、银。湿法王水溶解样品,碘量法测定主体元素铜。电感耦合等离子体发射光谱(ICP-AES)法测定其它杂质元素,被测元素质量浓度在0~10μg/mL范围内与光谱强度呈良好线性关系,相关系数均大于0.9998。测定结果的相对标准偏差小于10%(n=5),加标回收率为97.0%~102.5%。该方法简单、快速,有效地解决了线路板样品不均匀而难采样,以及硬度、韧性强制样难,金属易包裹难分解的技术瓶颈,测定结果准确,具有代表性。该方法适用于废弃线路板化学成分分析,其它废弃电子产品检测可参考此方法。  相似文献   

20.
Quantitative analytical methods, based on high-performance liquid chromatography with electrochemical detection, were developed for fenoldopam and its metabolites in human plasma. Two extraction methods, a liquid-liquid extraction method for fenoldopam and its methoxy metabolites and a liquid-solid extraction procedure for the sulfate and glucuronide conjugates of fenoldopam were developed. The extractions can either be performed manually or by robot. The limit of detection for fenoldopam, its sulfate and methoxy metabolites was 0.025, 2 and 0.5 ng/ml, respectively, at a signal to noise ratio of 4. The intra-assay and inter-assay coefficients of variation for both manual and robotic extraction procedures were comparable. These methods were suitably selective and sensitive for pharmacokinetic and metabolic studies of fenoldopam.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号