首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The experimental sensitivity for 72 different elements using 3 MeV neutron activation has been investigated. Using a 200 kV Cockcroft-Walton neutron generator with a 3 MeV neutron flux of about 1.5·106n·cm−2·sec−1, γ-ray spectra of 51 elements were obtained with a sufficient number of photopeak counts for sensitivity calculations using a photopeak integration method. A useful table summarizing the sensitivity results is given. That 3 MeV neutron activation analysis is practical, is demonstrated by the experimental sensitivities obtained. Guest worker from the Institute of Nuclear Techniques, Academy of Mining and Metallurgy, Krakow, Poland, at the National Bureau of Standards, 1968–1969.  相似文献   

2.
At the GKSS Research Center Geesthacht, a new 14 MeV activation facility—a 5·1012 n/s neutron generator combined with a fast rabbit system (KORONA)—is being installed. Homogeneous neutron flux at a level of 5·1010 n·cm−2·s−1 and sample transfer times of 140 ms to a 16m distant detector station are characteristic features of the facility described in the paper. With special consideration of short-lived nuclides and including cyclic activation, the analytical prospects with the intense neutron source are discussed, and sensitivities for 78 elements are presented.  相似文献   

3.
A new intense 14 MeV neutron generator with cylindrical acceleration structure has been put in operation at the GKSS Research Center Geesthacht. The sealed neutron tube is combined with a fast pneumatic rabbit system with particular capabilities for neutron activation analysis involving shortlived reaction products. The sample transfer time is less than 140 ms. The maximum neutron flux available for activation is 5.2·1010 n/cm2s. Theoretical sensitivity predictions made in a previous study have been verified for some important trace elements. As a first application, samples of freeze-dried suspended matter and fishes of the Elbe river were analyzed.  相似文献   

4.
The purpose of this study was to define experimentally the sensitivity of determination for 63 different elements by 14 MeV neutron activation, with a 150 kV Cockroft-Walton accelerator at a neutron flux of 2·108 n·cm−2·sec−1 on the sample. The obtained gamma ray spectra are given, and the origin of the photopeaks observed are explained. A maximum irradiation time of five minutes was used as a convenient experimental limit to obtain the maximum sensitivity, considering, however, that the tritium target life is limited, and that the time to perform an analysis has to be reasonable. The practical use of 14 MeV neutron activation analysis is demonstrated by the detection limits obtained.  相似文献   

5.
Representative banded iron-formations (BIFs) from various locations of the eastern Indian geological belt were investigated by instrumental neutron activation analysis (INAA). After pre-concentration, irradiation was carried out using a neutron flux of 5.1·1016 m−2·s−1, 1.0·1015 m−2·s−1 and 3.7·1015 m−2s−1, with thermal, epi-thermal and fast neutrons, respectively. The activities in these samples were measured by a HPGe detector. Ten rare-earth elements, such as La, Ce, Nd, Sm, Eu, Tb, Ho, Tm, Yb and Lu, have been qualitatively identified and quantitatively estimated in these samples. The present investigation is an example of employing a pre-concentration method for high iron-containing ores prior to neutron activation analysis.  相似文献   

6.
7.
A delayed neutron counting system has been implemented at the HANARO research reactor in 2007. Thermal neutron flux measured at the NAA #2 irradiation hole coupled to the delayed counting system, was higher than 3 × 1013 n cm−2 s−1. The delayed neutron counting system is composed of 18 3He detectors which are divided into three groups with six detectors and the collected signals of each group are processed to a digital signal. The count numbers were measured with the uranium mass by using NIST SRMs under fixed analytical condition and their correlation could be determined. Finally, delayed neutron activation analysis has been carried out for the determination of uranium mass fraction in the collected environmental samples.  相似文献   

8.
The applicability of fast and thermal neutron activation analyses for the determination of gold in rock samples has been studied. Using a Ge/Li/ detector limit of 0.45 mg g−1 was obtained for a fast neutron flux of 8.107 n cm−2.s−1. With a thermal neutron flux of 6.105 n cm−2.s−1 and the same detector a value of 35 μg g−1 was obtained. Using a NaI/Tl/ crystal a sensitivity of 14 μg g−1 was attained at the same thermal flux. This work was supported in part by the Hungarian Academy of Sciences.  相似文献   

9.
An alternative method of approach has been developed for the measurement of thermal neutron flux. The method depends only on the activity of the bare foil if the cadmium ratio at the irradiation position is known. The method has been tested on the GHARR-1 facility at the Ghana Atomic Energy Commission using gold and indium foils for the measurement of the thermal neutron flux in the flux range of 1010–1012 n·cm−2·s−1 and the results compare very well with those obtained using the conventional method (cadmium separation method).  相似文献   

10.
Vanadium in serum has been investigated by the aid of neutron activation analysis (8 min irradiation at 8·1013 n·cm−2·s−1 in the reactor FR-II of the Kernforschungszentrum in Karlsruhe). The lyophilized samples were dry-ashed before irradiation and the52V activity extracted after irradiation. The values for V in the sera of 22 healthy males ranged from 0.029–0.939 ng V·ml−1. There is a real assumption that some of the high figures are due to persons being contaminated with V. The 18 healthy females yielded a mean value of 0.033±0.012 ng V·ml−1 for 17 of them and one additional value of 0.139 ng V·ml−1. These V-data are the lowest ever reported in the literature. The analyses of two packed blood cell samples yielded 0.031 and 0.020 ng·g−1, indicating that about 68% of the total V in blood is present in serum. There was no correlation between the V-content and age, nor between the V-content and the cholesterol, triglycerides or the lipoprotein fractions in serum.  相似文献   

11.
Characteristics of a source of thermal neutrons based on an evacuated NG-400 neutron generator with the maximum flux (Φf) 2 × 1011 neutron/s for 14 MeV neutrons and 2 × 109 neutrons/s for 3 meV neutrons have been investigated. The possibilities of its application for neutron activation analysis have been estimated. The distribution, composition, and density (φT) values of the thermal neutron flux have been measured in the inner cavity of the moderator using activation detectors. φT was 2 × 108 and 2 × 106 neutrons/cm2 s for thermalized neutrons with energies of 14 and 3 MeV, respectively. The possibilities of the apparatus have been estimated theoretically and experimentally for the cases of thermalized neutrons of 14 MeV and 3 MeV.  相似文献   

12.
A procedure involving the irradiation of coal samples with 14 MeV neutrons and subsequent gamma-ray spectrometry of the irradiated sample for the estimation of solfur in coal, has been outlined. The samples were irradiated with 14MeV neutrons from a Cockroft-Walton type generator for one minute and then subjected to gamma-ray spectrometry for another minute using an automated transfer cyclic system. Ten such cycles were repeated for accumulating events under the 2130 keV gamma ray photopeak belonging to34P (T=12.4 s) produced by the34S(n, p)34P reaction for assessing the lower level of detection, LLD, of Sulfur. Interferences due to the presence of other elements in coal were also determined. Sulfur can be determined at LLD of 0.25% in coal provided a 5 g sample of the coal is irradiated with a neutron flux of 5·109 n·cm−2·sec−1 assayed with a gamma ray spectrometer having a large hollow core Ge(Li) detector and an anti-Compton shield.  相似文献   

13.
Loaded and unloaded polyurethane foams were examined as a preconcentration matrix in combination with neutron activation analysis. The structure of the foamed polymer is not damaged by short irradiation periods. However the foam skeleton degraded after irradiations for one hour or longer in a neutron flux of 3·1013 n ·cm−2·s−1. The presence of tin as a major impurity in the polyether-type foam has been detected. This may affect the sensitivity of determination of the relatively short lived isotopes of the elements collected on the foam. On the other hand the polyester-type foam was found to contain only very low amounts of tin. Antimony, indium, gold and mercury collected on the foams were determined with reasonable accuracy.  相似文献   

14.
Recently a new rapid pneumatic tube facility was inserted into a long unused location in the NIST 20 MW nuclear reactor. This facility was designed and constructed specifically for rapid INAA using short lived activation products. Included is a computer controlled console which uses fast sensors to accurately measure the irradiation capsule flight time, and a loss-free counting system connected to a 32% efficient PHGe detector with a transistor reset preamplifier. Measurement of travel, times from end-of-irradiation to detector were 473±8 ms. Measurement of the thermal neutron fluence rate was 5.0·1013 n·cm−2·s−1. The other three pneumatic tubes in the NIST reactor have transfer times of 3 to 15 seconds, and no timing capability more accurate than human response. This new facility substantially improves our ability to accurately determine activation products with half-lives from 1 to 100 seconds. Characterization information reported on this new irradiation facility includes absolute fluence measurements, fluence rate variations within the capsule and variations with time, and determination of analytical sensitivities for fluorine-20 selenium-77m, and silver-110g.  相似文献   

15.
China Advance Research Reactor (CARR) at China Institute of Atomic Energy (CIAE), with a non-perturbed maximum thermal neutron flux of 1 × 1015 cm−2 s−1 at the center of active area, is one of the most powerful research reactors in the world. Three neutron channels have been allocated for conventional neutron activation analysis (NAA), thermal neutron prompt gamma activation analysis (PGAA) and cold neutron PGAA, respectively. Two irradiation tube systems are installed in the conventional NAA channel. One of them is for short irradiation with the rabbit size of diameter (Φ)19 × 40 mm, the other one is for long irradiation with the rabbit size of Φ39 × 70 mm. The medium temperature is about 45 °C and the thermal neutron flux is about 3 × 1014 cm−2 s−1 at sample positions. The flux gradient is expected to be very small according to the designed neutron flux distribution. Pneumatic systems are used for samples transfer. The speed of rabbits is designed to be about 20 m/s, and it takes 3 s to travel from irradiation position to detector. Three sets of gamma counting systems and one delayed neutron counting system are being equipped for routine analysis. They are designed for running continuously and automatically. And all the functions can be operated at laboratory or office through remote controlled computer. Software has been made domestically for spectrum peak search, concentration calculation with relative method and k0 method with interference corrections and some other functions for the convenience of users.  相似文献   

16.
A combination of solid phase extraction, coprecipitation, and neutron activation techniques has been used to develop a speciation analysis method based on green chemistry for the major arsenic species in drinking water. Arsenate as As(V), monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA) are separated and preconcentrated by strongly anion and cation exchange columns in tandem while As(III) remains in the effluent. These species are then selectively eluted and As(III) coprecipitated with bismuth sulphide. This simple method has been applied to the analysis of water reference materials with good results. The detection limits are 0.9, 1.7, 1.6, 3.8 and 16 ng mL−1 for As(III), As(V), MMA, DMA and total arsenic, respectively, using a neutron flux of 2.5 × 1011 cm−2 s−1 at the Dalhousie University SLOWPOKE-2 reactor (DUSR) facility and anti-coincidence gamma-ray spectrometry.  相似文献   

17.
Stray neutron distribution in a medical cyclotron vault room was evaluated by neutron activation analysis (NAA). Neutrons were generated in the production of radioactive nuclides, such as 18F, 11C, 13N and 15O, for diagnostic usage. Indium foil was adopted to evaluate the stray fast and thermal neutron intensity based on 115In(nf, n′)115mIn and 115In(nth, γ)116m1In reactions, respectively. The indium foils were weighed, sealed and placed at 62 points around the 6.7×8.2 m2 cyclotron room. Additionally, each indium foil was exposed for over 80 minutes during cyclotron operation and γ-peaks were analyzed using an HPGe detector to evaluate the number of stray fast (Φ f) or thermal (Φ th) neutrons. The minimum to maximum numbers of fast and thermal neutrons were (3.47±0.11)×103 to (1.06±0.21)×104 n·cm−2·s−1 and 9 to 965 n·cm−2·s−1, respectively. The minimum detectable limit for stray neutrons was included herein to demonstrate the reliability. Accordingly, 60 and two points, respectively, the confidence level associated with the reported intensities of fast and thermal neutrons reached 95%. The low qualified ratio in the evaluation of stray thermal neutrons might have been caused by either the high Compton scattering plateau or the low intensity of the gamma-ray peak in the relevant spectrum.  相似文献   

18.
The medium energy intense neutrons (MEIN) available at the Brookhaven Chemistry Linac Irradiation Facility have an energy distribution up to ∼160 MeV an effective neutron flux of ∼1.3×1011 cm−2s−1. The present work explores the feasibility of using this facility for the analysis of Tl, Pb and Bi by activation with MEIN. The most sensitive reactions, from a practical standpoint, were found to be Tl (n, xn)200Tl (x=4, 6), Pb (n, xn)204mPb (x=0, 3, 4. 5) and209Bi (n, 6n)204Bi. The absolute sensitivities attainable with these reactions are 0.1, 0.05 and 0.08 μg of Tl, Pb and Bi respectively, for 1 h irradiation at 1.3×1011 n cm−2s−1 with samples counted 2 h after the end of irradiation. The advantages of the method over thermal neutron activation analysis are that all three elements can be assayed at the sub-microgram concentration levels by γ-spectrometry with the help of a simple radiochemical purification and the analytical results can be verified by cross checking via the multiple (n, xn) reaction products. However, interference from Bi in the determination of Pb and from Pb and Bi in the determination of Tl limits its usefulness to the analysis of Bi. This research was sponsored under contract with the United States Department of Energy supported by its Office of Basic Energy Sciences (support for H.L. FINSTON is under Contract no. DE-AC02-76-ER03126).  相似文献   

19.
The Si-contents of flue-dust and sedimented dust from Czechoslovak mines were determined by instrumental activation analysis with 14 MeV neutrons using a flux of 107 cm−2·s−1. The amounts determined range from 3 to 30 mg.  相似文献   

20.
A sensitive, simple and time-saving method has been developed for the neutron activation analysis of gallium at concentrations around 10−4 ppm in biological tissues. After a 24-hour irradiation in a thermal neutron flux of 2.8·1013 n·cm−2·s−1 and a purification by ion-exchange chromatography to eliminate troublesome elements such as sodium, iron and copper, the72Ga activity is measured with enough accuracy for the method to be applicable in animal physiology and clinical toxicology.  相似文献   