首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Simultaneous determination of aliphatic C2–C20 carboxylic acids and their methyl esters was carried out using SE-30 and OV-351 quartz capillary columns with temperature programming. Complete resolution of all 36 components was achieved. On SE-30 the methyl ester and the corresponding free acid are eluted in turn, whereas on OV-351 acetic acid eluted after methyl octanoate, after which the Cn methyl ester and Cn-6 carboxylic acid (n>9) are eluted one after the other. A non-polar SE-30 column is better for long-chain acids giving sharp peaks without tailing, the analysis time of the mixture being less than 16 minutes. The weight response correction factors for compounds under optimum operating conditions are given.  相似文献   

2.
A procedure is described for the quantitative determination of amino acids in hepatic and brain tissue samples from the rat. Because the presence of certain matrix components in the tissue material led to interference with chromatographic analysis they were removed by a prechromatographic “clean-up” step. Quantitative analysis of amino acids, as their N-heptafluorobutyryl iso-butyl ester derivatives, was achieved by high resolution gas chromatography on an apolar fused silica open tubular column. Reproducibility data from the complete procedure are presented; coefficients of variation for arginine and histidine in hepatic tissue varied between 7.1 and 10.1% whereas those for most other amino acids were better than 5%, with a mean recovery of 90%.  相似文献   

3.
A gas-liquid chromatographic procedure is described which will separate and quantitate the seventeen amino acids typically found in protein acid hydrolyzates. If present, tryptophan, cysteine and carboxymethylcysteine can also be simultaneously assayed via this method. The amino acids, as their tert.-butyldimethylsilylated derivatives, are readily separable on SE-30 (wall-coated open-tubular) and OV-17 (bonded) capillary columns, as well as on packed gas-liquid chromatographic columns coated with the same liquid phases. Retention times and responses for all amino acids and internal standards are given. Mass spectral analysis of all tert.-butyldimethylsilylated amino acids is presented and displays a characteristic and unique [M- 57] fragment ion for each amino acid which often dominates the mass spectrum. Application of this method is demonstrated using four well characterized proteins.  相似文献   

4.
The retention behaviour of C1---C18n-alkyl esters of butanoic 2-, 3- and 4-chlorobutanoic acids was examined isothermally at several temperatures on SE-30 and OV-351 capillary columns. Retention increments showing the effects of each position of chlorine substitution are presented. The considerable enhancement of terminal chlorine substitution is discussed together with the corresponding behaviour of the monochloropropanoate esters.  相似文献   

5.
The gas chromatographic behavior of di-n-alkylketones and isomeric methylcyclohexanones at variable temperatures in the isothermal runs has been studied using three capillary columns coated with SE-30, OV-225, and PEG-40M/KF stationary phases. The retention indices and their temperature increments were determined, and the partial molar free energies of the compounds under study were calculated. A linear dependence of the values of the partial molar free energy of sorption on the homologue number in di-n-alkylketones is not observed for the first member on the nonpolar SE-30 phase and for the third member on the polar OV-225 and PEG-40M/KF phases. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 2, pp. 328–332, February, 1997.  相似文献   

6.
The Saccharomyces strains uvarum, montuliensis, bayanus, capensis and florentinus were grown in liquid media prepared from a 1% aqueous glucose solution to which 0.05% of ammonium sulfate or urea were added as the only nitrogen supply. The amino acids exuded during incubation were isolated by cation exchange and derivatized as the corresponding N,O-heptafluorobutyryl isopropyl esters. Separation was achieved on a highly deactivated glass capillary column coated with OV-101. A characteristic amino acid profile was obtained for each of the species studied, allowing the construction of a chemotaxonomic tree, on the basis of present or absent acids.  相似文献   

7.
High-resolution gas chromatography (HRGC) and gas chromatography/mass spectrometry (GC/MS) are the techniques of choice to determine the retention indices of more than 200 organic acids as their trimethylsilyl (TMS) or oxime-trimethylsilyl derivatives. Several types of apolar and semipolar fused-silica capillary columns (OV-1, SE-52, and OV-1701), used to analyze and separate organic acids isolated from urine samples, are evaluated.  相似文献   

8.
Summary Gas chromatography of mixtures of aliphaticn-alkyl acetates (CH3–COOR), chloroacetates (CHCl2–COOR), dichloroacetates (CHCl2–COOR) and trichloroacetates (CCl3–COOR), where the alcohol chain length (R) varied between 1 and 8, has been studied on SE-30, Carbowax 20M and OV-351 glass capillary columns with programmed temperatures from 50°C at 2, 4, 6, 8 and 10°C/min. Compounds in the homologous series are eluted in the direct order from methyl ton-octyl acetate. The isomeric chloro esters are eluted on SE-30 according to their boiling points in the order: mono-, di- and trichloro isomer, whereas on polar columns di- and trichloro esters are eluted in the reverse order. The complete separation of all 32 individual components from the mixture could not be reached by any single column, the best separation occurred on SE-30. The mixture can, however, be separated by using columns with polar and non-polar stationary phases. The relative retention times for the compounds are given and the retention order discussed.  相似文献   

9.
Studies have been performed on the analysis of 21 amino acids using a fused-silica open tubular (FSOT) capillary column, and electron-capture detection (ECD) or flame-ionization detection (FID). It was shown with the N(O)-heptafluorobutyryl (HFB) amino acid isobutyl esters that the ECD response was several hundred times more sensitive than the FID response. The relative standard deviation (RSD) of retention relative to norleucine is determined with the ECD. RSD values for all N(O)-HFB amino acid isobutyl esters are relatively small (≦ 0.5%). This method has been successfully applied to trace analysis of most of the amino acids from fossil brachiopods and black shales.  相似文献   

10.
A procedure is described in which a wide bore capillary column is used as an alternative to the more traditional packed column for the quantitative analysis of amino acids as their N-heptafluorobutyryl isobutyl ester (HBB) derivatives. The column, installed in a gas chromatograph previously configured for use with a packed column, is shown to give good reproducibility by repeated determination of amino acid response factors (RSD values for all amino acids are below 3%). A number of problems, encountered during the use of this column, are discussed and suitable techniques to overcome them are reported.  相似文献   

11.
A method is given for a one-step derivatization and gas chromatography of amino acids in blood and protein hydrolysates. Blood samples are partially purified by solvent extraction. Protein hydrolysates are neutralized with a triethylamine solution. Then tert.-butyldimethylsilyl derivatives of the amino acids are prepared in a one-step procedure and separated on a 30-m fused-silica SE-30 capillary column. Except for tryptophan and cystine, amino acids are eluted within 30 min. Amino acids are derivatized more rapidly than their corresponding trimethylsilyl derivatives and do not degrade on the long fused-silica columns.  相似文献   

12.
Summary The gas chromatography of acetyl derivatives of guaiacol and all chlorinated guaiacols has been studied on SE-30, OV-351 and Carbowax 20M capillary columns. The retention order and relative retention times under isotermal and temperature-programmed conditions are discussed. Different retention times for all mono- and dichloro compounds have been observed on the SE-30 column. However, all trichloroguaiacol isomers were separated only on polar columns. The best overall temperature-programmed separations have been achieved on an SE-30 capillary column.  相似文献   

13.
An analytical method for phenols has been adapted for the analysis of chlorophenylmercapturic acids in rat urine. Chlorothiophenols were produced from the mercapturic acids by hydrolytic cleavage with sodium hydroxide. Acetate esters of the chlorothiophenols were formed by addition of acetic anhydride to the aqueous alkaline solution. After acylation, the acetate derivatives were extracted into hexane. Forming the acetate esters of the chlorothiophenols prevented their oxidation to disulfides and significantly improved their chromatographic properties. Electron-capture gas chromatographic analysis of the stable acetate esters was performed on a mixed phase column, 4% SE-30 + 6% OV-210. Recoveries of four chlorothiophenols ranged from 82 to 93%. This method required no sample transfer steps; therefore, sample loss and analysis time were minimized.  相似文献   

14.
Retention indices of 54 alcohols and 55 alcohol benzoyl derivatives measured on short stainless steel columns (1 m × 2 mm i.d.) filled with Chromosorb G (AWDMCS (HP)) coated with 5% (ww) SE-30, OV-3, OV-7, OV-11, OV-17 or OV-25 stationary phases at 100°C, 120°C and 140°C, appear to be very accurate, provided that there is careful control of the Chromatographic process. Values of the temperature dependence of retention index of alcohols and benzoates, and variations of these values with the polarity of the phase used, are given.  相似文献   

15.
Nitrilotriacetic acid was separated (as its tri-n-butyl ester) from twenty-four other fatty, phenolic and polycarboxylic acids, using prepacked commercial OV-210 columns. Quantitative analysis down to 0.010 mg nitrilotriacetic acid per liter was demonstrated. The molar responses and retention times of the acids, relative to phthalic acid, were determined.  相似文献   

16.
Summary Columns of SE-30 and OV-17 on Chromosorb W, Apiezon N on Chromosorb G and Tenax-GC porous polymer were compared for their ability to separate bacterial amines converted to carbethoxy, dinitrophenyl, trimethylsilyl, Schiff base and fluorinated Schiff base derivatives.Tenax-GC performed less well than the other packings with respect to the number of plates and peak resolution. Dinitrophenyl and trimethylsilyl derivatives were both unsatisfactory for analysis of bacterial amines. Schiff bases and their fluorinated derivatives were found to be the most suitable. However, the former were preferred as the use of fluorinated Schiff bases confered little advantage when a flame ionization detector was employed. A maximum of 16 amines was separated, using columns of OV17 on Chromosorb W programmed from 110 °C to 280 °C at 5.5 °C min–1 after an initial holding time of 6 min. The application of the method to analysis of cultures ofProteus mirabilis yielded two amines tentatively identified asiso-butylamine andiso-amylamine.  相似文献   

17.
常东亮  哈成勇 《色谱》1999,17(6):576-577
 摘要:研究了单萜/顺酐加成物及其酯化衍生物在OV-17和SE-30柱上的某些色谱性能和定量分析的线性相应关系。结果表明,这两种化合物在涂渍量为5%~10%的OV-17和SE-30柱上均能正常出峰;在峰形对称性和出峰时间上,OV-17柱具有优势。260℃以后,色谱峰面积与汽化温度无关。  相似文献   

18.
A new mixed crosslinking agent composed of dicumyl peroxide and tetra(methylvinyl)cyclotetrasiloxane was used to prepare fused silica capillary columns with in situ crosslinked stationary phases including PEG-20M, SE-54, and OV-1. These columns proved to have good thermostability and inertness. As examples of potential applications a mixture of isomers of nitrotoluene and dinitrotoluene, and pyrolyzates of polystyrene were separated by using these columns.  相似文献   

19.
Reaction of amino acids with N-methyl-N-(tert-butyldimethylsilyl)trifluoroaceamide (MTbSTFA) in acetonitrile affords good yields of amino acid derivatives with excellent gas chromatographic and mass spectrometric properties. The single-step derivatization procedure is highly reproducible. The TBDMS amino acids are stable at room temperature for at least three days. Only a single peak is observed for each amino acid. The procedure allows simultaneous analysis of asparagine and glutamine together with other serum amino acids. Separation is achieved on a borosilicate glass capillary coated with OV-1. The mass spectra of the TBDMS amino acids possess characteristic diagnostic ions. These properties were used in the sensitive detection by GC-MS and SIM-GC-MS of GABA and pipecolic acid in the serum of a newborn suspected of a Zellweger-type syndrome, which could not be detected by other methods.  相似文献   

20.
Relative retention times and methylene unit (MU) values were determined for 56 bile acids of the allo (5 alpha, A/B-trans) and normal (5 beta, A/B-cis) series, which differ from one another in the number, position and configuration of the hydroxyl groups at positions C-3, C-6, C-7 and/or C-12. The bile acids were derivatized to their methyl ester O-trimethylsilyl ethers (Me-TMS) and methyl ester O-dimethylethylsilyl ethers (Me-DMES), and chromatographed on fused-silica capillary columns, chemically bonded with non-selective OV-1 and selective PEG-20M liquid phases. Of the four possible combinations of derivatives and columns examined, Me-DMES on OV-1 and Me-TMS on PEG-20M were most suitable. The differences in the MU values between the 5 alpha- and 5 beta-series, and between the Me-DMES and Me-TMS ether derivatives, are also summarized. These retention data would be helpful in the identification of closely related bile acid stereoisomers or for estimation of their structures. photolysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号