首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study examined whether increasing the similarity between informational maskers and signals would increase the amount of masking obtained in a nonspeech pattern identification task. The signals were contiguous sequences of pure-tone bursts arranged in six narrow-band spectro-temporal patterns. The informational maskers were sequences of multitone bursts played synchronously with the signal tones. The listener's task was to identify the patterns in a 1-interval 6-alternative forced-choice procedure. Three types of multitone maskers were generated according to different randomization rules. For the least signal-like informational masker, the components in each multitone burst were chosen at random within the frequency range of 200-6500 Hz, excluding a "protected region" around the signal frequencies. For the intermediate masker, the frequency components in the first burst were chosen quasirandomly, but the components in successive bursts were constrained to fall in narrow frequency bands around the frequencies of the components in the initial burst. Within the narrow bands the frequencies were randomized. This masker was considered to be more similar to the signal patterns because it consisted of a set of narrow-band sequences any one of which might be mistaken for a signal pattern. The most signal-like masker was similar to the intermediate masker in that it consisted of a set of synchronously played narrow-band sequences, but the variation in frequency within each sequence was sinusoidal, completing roughly one period in a sequence. This masker consisted of discernible patterns but not patterns that were part of the set of signals. In addition, masking produced by Gaussian noise bursts--thought to produce primarily peripherally based "energetic masking"--was measured and compared to the informational masking results. For the three informational maskers, more masking was produced by the maskers comprised of narrow-band sequences than for the masker in which the frequencies were not constrained to narrow bands. Also, the slopes of the performance-level functions for the three informational maskers were much shallower than for the Gaussian noise masker or for no masker. The findings provided qualified support for the hypothesis that increasing the similarity between signals and maskers, or parts of the maskers, causes greater informational masking. However, it is also possible that the greater masking was a consequence of increasing the number of perceptual "streams" that had to be evaluated by the listener.  相似文献   

2.
Two experiments investigated the relative influence of components close to and remote from the signal frequency (fs) on the overshoot effect. Overshoot was defined as the difference in threshold between a signal presented 4 ms after, and that for one presented 300 ms after, the onset of a 350-ms masker. Experiment 1 measured the overshoot effect using both wideband and narrow-band maskers (centered on fs), at two signal frequencies and three masker levels. Experiment 2 used a masker consisting of a "middle band" (MB, centered on fs) and two flanking bands (FBs, which, when combined with the MB, produced a flat wideband spectrum). The masker was continuous except for a 300-ms interval just prior to the signal, during which either all three bands, the MB alone, or the FBs alone were turned off. The results of both experiments showed that the overshoot effect was usually determined by off-frequency components. However, the on-frequency components played a substantial role when signal-to-noise ratios (SNRs) at threshold were unusually high, such as at fs = 6500 Hz and intermediate masker levels. It is suggested that two different mechanisms contribute to the overshoot effect: an off-frequency mechanism which operates at all fs and masker levels, and an on-frequency mechanism which contributes to the overshoot effect only at high-threshold SNRs.  相似文献   

3.
When very brief tonal signals are presented immediately after the onset of a gated noise masker, detectability can be 10-20 dB worse than when the signal is delayed by several hundred milliseconds, an effect known as the overshoot. It has long been known that, when an "onset" is created in an otherwise continuous, broadband masker by briefly turning it off and on again, the detectability of a brief signal presented soon after this temporal gap will decline gradually as the gap is increased from a few milliseconds to a few hundred milliseconds. In other words, the auditory system recovers to its quiescent, resting state following an adequate silent interval. Here, the broadband maskers consisted of three adjacent spectral bands--one centered on the frequency of the tonal signal, one low passed below the lower edge of the center band, and one high passed above the upper edge of the center band. The signal was a 2500-Hz tone having a total duration of 6 ms. In different blocks of trials, either all three bands, only the center band, or only the two flanking bands were temporally gapped by a duration ranging from 10-300 ms. When the center band was about 750 Hz wide (about 2.5 critical bandwidths), this differential gapping process resulted in typical recovery functions when all three bands (the entire spectrum) or when just the two flanking bands were gapped. However, when only the center band was gapped, there was no evident recovery--rather, detectability remained near the signal level required with a continuous masker, even for a gap duration of 300 ms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
These experiments examine how comodulation masking release (CMR) varies with masker bandwidth, modulator bandwidth, and signal duration. In experiment 1, thresholds were measured for a 400-ms, 2000-Hz signal masked by continuous noise varying in bandwidth from 50-3200 Hz in 1-oct steps. In one condition, using random noise maskers, thresholds increased with increasing bandwidth up to 400 Hz and then remained approximately constant. In another set of conditions, the masker was multiplied (amplitude modulated) by a low-pass noise (bandwidth varied from 12.5-400 Hz in 1-oct steps). This produced correlated envelope fluctuations across frequency. Thresholds were generally lower than for random noise maskers with the same bandwidth. For maskers less than one critical band wide, the release from masking was largest (about 5 dB) for maskers with low rates of modulation (12.5-Hz-wide low-pass modulator). It is argued that this release from masking is not a "true" CMR but results from a within-channel cue. For broadband maskers (greater than 400 Hz), the release from masking increased with increasing masker bandwidth and decreasing modulator bandwidth, reaching an asymptote of 12 dB for a masker bandwidth of 800 Hz and a modulator bandwidth of 50 Hz. Most of this release from masking can be attributed to a CMR. In experiment 2, the modulator bandwidth was fixed at 12.5 Hz and the signal duration was varied. For masker bandwidths greater than 400 Hz, the CMR decreased from 12 to 5 dB as the signal duration was decreased from 400 to 25 ms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
These experiments investigated whether perceptual cueing plays a role in the "unmasking" effects which have been observed in forward masking for narrow-band noise maskers and brief signals. The forward masking produced by a 100-Hz-wide noise masker at a level of 60 dB SPL was measured for a 1-kHz sinusoidal signal with a raised-cosine envelope and a duration of 10 ms at the 6-dB-down points, both for the masker alone, and with various components added to the masker (and gated synchronously with the masker). Unmasking was found to occur even for components which were extremely unlikely to produce a significant suppression of the masker: these included a 75-dB SPL 4-kHz sinusoid, a 50-dB SPL 1.4-kHz sinusoid, a noise low-pass filtered at 4 kHz with a spectrum level of 0 dB, and a noise low-pass filtered at 4 kHz with a spectrum level of 20 dB presented in the opposite ear to the masker-plus-signal. It is concluded that perceptual cueing can play a significant role in producing unmasking for brief signals following narrow-band noise maskers, and that it is unwise to interpret the unmasking solely in terms of suppression.  相似文献   

6.
Current understanding of the relation monaural estimates of the critical bandwidth for masking and those obtained in binaural listening situations is poor. The present study was designed to improve this situation by obtaining estimates of critical bandwich when the signal and masker were presented: (1) monaurally (NmSm), (2) binaurally with both signal and masker in phase at the ears (NoSo), (3) binaurally with masker in phase and signals 180 degrees out of phase (NoSpi). Threshold estimates were obtained in a two-interval forced-choice paradigm as a function of masker bandwidth for signal frequencies of 500 and 2000 Hz for the three conditions mentioned above. Maskers were computer-synthesized and had essentially infinite rejection slopes. For all conditions, as masker bandwidth was narrowed from wide band, threshold remained relatively constant until some critical bandwidth was reached. Further reductions in bandwidth were followed by progressive lowering of threshold, presumably due to removal of masker energy in the critical band. For both signal frequencies, the derived critical bandwidth estimates for the NmSm and NoSo conditions were similar and were smaller than the critical bandwidth estimates obtained in the NoSpi condition.  相似文献   

7.
This and two accompanying articles [Breebaart et al., J. Acoust. Soc. Am. 110, 1074-1088 (2001); 110, 1105-1117 (2001)] describe a computational model for the signal processing in the binaural auditory system. The model consists of several stages of monaural and binaural preprocessing combined with an optimal detector. In the present article the model is tested and validated by comparing its predictions with experimental data for binaural discrimination and masking conditions as a function of the spectral parameters of both masker and signal. For this purpose, the model is used as an artificial observer in a three-interval, forced-choice adaptive procedure. All model parameters were kept constant for all simulations described in this and the subsequent article. The effects of the following experimental parameters were investigated: center frequency of both masker and target, bandwidth of masker and target, the interaural phase relations of masker and target, and the level of the masker. Several phenomena that occur in binaural listening conditions can be accounted for. These include the wider effective binaural critical bandwidth observed in band-widening NoS(pi) conditions, the different masker-level dependence of binaural detection thresholds for narrow- and for wide-band maskers, the unification of IID and ITD sensitivity with binaural detection data, and the dependence of binaural thresholds on frequency.  相似文献   

8.
The just-noticeable-difference in frequency (jndf) for complex signals with triangular spectral envelopes is found to depend on the envelope slope. For shallow slopes (less than 140 dB/oct), jndf increases with decreasing slope. Addition of noise also impairs frequency discrimination within a region of about 20 dB above masked threshold. This is found for both maskers used: a wideband noise and a narrow-band masker which is below the signal in frequency. When wideband noise is used, frequency discrimination of complex signals with shallow slopes deteriorates more rapidly with decreasing signal-to-noise ratio than it does when the signals have steep spectral slopes.  相似文献   

9.
This study examines how simultaneous masking of a tone by bandlimited noise may be affected by nonlinear interactions among spectral components of the noise. Simultaneous masking patterns (signal threshold versus signal frequency) were obtained with three types of maskers: (A) a narrow-band noise, 50 Hz wide with variable center frequency fv, (B) pairs of narrow-band noises, each band 50 Hz wide with center frequencies fl and fu, and (C) wide-band noise formed by filling the spectral gap between the two bands of (B). The variable frequency fv was set to 1.0, 1.1, 1.2, and 1.3 kHz: fl was fixed at 1.0 kHz, and fu had values of 1.1, 1.2, and 1.3 kHz. In most conditions, the two-band maskers and the wideband maskers produced more masking than would be predicted from the masking produced by the single narrow-band maskers. For certain signal frequencies below the maskers, adding noise to fill the spectral gap of the two-band masker actually resulted in a 3- to 15-dB release from masking. These results reveal factors that may operate to confound modern measures of frequency selectivity.  相似文献   

10.
A common metric of auditory temporal processing is the difference in the threshold for a pure-tone signal masked by either unmodulated or amplitude-modulated noise. This technique may be viewed as a modification of the masking period pattern technique. Such measurements have been proposed as an efficient means of estimating auditory temporal resolution in a clinical setting, although in many cases threshold differences may reflect additional spectro-temporal processes. The primary purpose of the present experiment was to examine interactions among signal frequency and masker bandwidth and the effects of modulation frequency on modified masking period patterns. The results revealed unmodulated-modulated threshold differences that increased with increasing masker bandwidth and decreased with increasing modulation frequency. There was little effect of signal frequency for narrow-band noise maskers that were equal in absolute bandwidth across frequency. However, unmodulated-modulated threshold differences increased substantially with increasing signal frequency for bandwidths proportional to the signal frequency and for wideband maskers. Although the results are interpreted in terms of a combination of both within-channel and across-channel cues, the specific contributions of these cues in particular conditions are difficult to ascertain. Because modified masking period patterns depend strongly upon a number of specific stimulus parameters, and because it is difficult to determine with any precision the underlying perceptual processes, this technique is not recommended for use as a clinical measure of auditory temporal processing.  相似文献   

11.
This study investigated comodulation detection differences (CDD) in children (ages 4.8-10.1 years) and adults. The signal was 30-Hz wide band of noise centered on 2 kHz, and the masker consisted of six 30-Hz wide bands of noise spanning center frequencies from 870 to 4160 Hz. The envelopes of the masking bands were always comodulated, and the envelope of the signal was either comodulated or random with respect to the masker. In some conditions, the maskers were gated on prior to the signal in order to minimize effects related to perceptual fusion of the signal and masker. CDD was computed as the difference between signal detection thresholds in conditions where all bands were comodulated and conditions where the envelope of the signal was random with respect to the envelopes of the maskers. Values of CDD were generally small in children compared to adults. In contrast, masking release related to masker/signal onset asynchrony was comparable across age groups. The small CDDs in children are discussed in terms of sensitivity to comodulation as a perceptual fusion cue and informational masking associated with the detection of a signal in a complex background, an effect that is ameliorated by asynchronous onset.  相似文献   

12.
Release from masking caused by envelope fluctuations   总被引:1,自引:0,他引:1  
This paper examines how short-term energy fluctuations in a masker affect the thresholds for tones at frequencies above those of the masker. Two equally intense tones at 1060 and 1075 Hz produce up to 25 dB less masking than does a 1075-Hz tone set to the overall level of the two-tone complex. At wider frequency separations, two-tone complexes also produce less masking than the pure tone. These results indicate that envelope fluctuations in a masker, whose spectrum is confined to a single critical band, may result in release from masking. The release from masking probably is related to the comodulation masking release reported by Hall et al. [J. Acoust. Soc. Am. 76, 50-56 (1984b)] for modulated-noise maskers with bandwidths greater than one critical band. Further measurements with maskers, whose intensity level in the critical band around 1 kHz was 90 dB SPL, show similar masking by a pure tone and a 625- to 1075-Hz bandpass noise, but less masking by narrow-band noises. These results are inconsistent with a simple frequency selective energy-detector model and indicate that the auditory system can use periods of low masker energy as brief as a few ms to enhance detection of a tone. The results also imply that the upward spread of excitation is best represented by masking patterns for noises with bandwidths of several critical bands.  相似文献   

13.
Confusion effects with sinusoidal and narrow-band noise forward maskers   总被引:2,自引:0,他引:2  
In some forward-masking conditions, signal thresholds may be elevated by the listener's inability to distinguish the signal from the preceding masker. In this study, such "confusion" effects are investigated for both sinusoidal and narrow-band noise forward maskers combined with sinusoidal signals of varying duration. Results for the sinusoidal maskers show effects of off-frequency listening for brief signals and possibly small effects of confusion for longer signals. Results for the narrow-band noise maskers show a marked influence of confusion over a wide range of signal durations. This range is in good agreement with that predicted from previous work with "pulsing" maskers [D. Neff, J. Acoust. Soc. Am. 78, 1966-1976 (1985)]. These results suggest that studies using narrow-band noise forward maskers or studies of psychophysical suppression should include direct tests for confusion effects in key conditions.  相似文献   

14.
Simultaneous masking of a 20-ms, 1-kHz signal was investigated using 50-ms gated and continuous sinusoidal maskers with frequencies below, at, and above 1 kHz. Gated maskers can produce considerably (5-20 dB) more masking than continuous maskers, and this difference does not appear to result from the spread of energy produced by gating either the masker or the signal. For masker frequencies below the signal frequency, this difference in masking is primarily due to the detection of the cubic difference tone in the continuous condition. For masker frequencies at and above the signal frequency, the difference appears to be an important property of masking. Implications of this frequency-dependent effect for measures of frequency selectivity are discussed.  相似文献   

15.
Additivity of simultaneous masking   总被引:1,自引:0,他引:1  
Simultaneous masking functions (signal level at threshold versus masker level) were obtained for equally intense maskers presented individually and in pairs. The signal was a 2.0-kHz sinusoid. The pairs of maskers were (1) two sinusoids with frequencies 1.9 and 2.1 kHz, (2) two narrow bands of noise (50 Hz wide) centered at 1.9 and 2.1 kHz, (3) two narrow bands of noise (50 Hz wide) centered at 1.8 and 1.9 kHz, and (4) the 1.9-kHz sinusoid combined with the narrow band of noise centered at 2.1 kHz. The pairs of maskers produced anywhere from 10 to 17 dB of masking beyond that predicted from the simple sum of the masking produced by the individual maskers. The amount of this "additional masking" was independent of masker level. Adding a continuous low level background noise reduced the amount of additional masking only slightly (approximately 5 dB). The data are consistent with a model in which the effects of the maskers are summed after undergoing independent compressive transformations.  相似文献   

16.
The results of two complementary detection tasks using digitally synthesized noise are reported. In one experiment the bandwidth of the synthetic noise was varied to reveal the region most effective in masking a 1-kHz signal. The bandwidth of the internal filter ("critical band") so measured was about 80 Hz. In another experiment, a wideband noise was used as the masker for a synthetic signal whose bandwidth another experiment, a wideband noise was used as the masker for a synthetic signal whose bandwidth was varied to determine the maximum effective width of the internal filter. Although some earlier experiments suggest maximum effective widths as small as 180-200 Hz (around 1 kHz), the data reported here indicate the range of spectral integration extends from the critical band to a maximum width that may exceed 3 kHz. In addition, the good agreement between the two experiments suggests a new method for estimating critical bandwidths based on the determination of two thresholds: that of a tonal signal in a wideband masker and that of a supracritical-width noise signal in a wider-bandwidth masker.  相似文献   

17.
Fastl and Bechly [J. Acoust. Soc. Am. 74, 754-757 (1983)] reported that the threshold of a brief 900-Hz signal simultaneously masked by a band of noise. 100 Hz wide, centered at 1000 Hz, was reduced by approximately 8 dB by the addition of an 1150-Hz tone having a level of 20 dB above that of the narrow-band masker. They concluded that this decrease in threshold was a demonstration of suppression in simultaneous masking. Here it is argued that Fastl and Bechly's results simply reflect the poorer detectability of signals masked by higher-frequency fluctuating maskers (their narrow-band masker) than by relatively flat-envelope maskers (their composite narrow-band plus tonal masker). The results of three experiments support the masker-envelope explanation. In the first experiment, as in the report of Fastl and Bechly, the masker centered at 1000 Hz (M1) was a narrow-band noise and the masker centered at 1150 Hz (M2) was a tone. Fastl and Bechly's result was replicated. However, thresholds obtained when M1 was presented alone (the M1-only condition) were more affected by the starting level of the signal within each adaptive track than were thresholds obtained when M1 and M2 were presented together (the M1+M2 condition). This result paralleled a previous report that starting level influenced performance more with fluctuating than with flat-envelope maskers. For the four of seven subjects wh showed learning, there was also more improvement in the M1-only than in the M1 + M2 condition. In the second experiment, M1 was a tone and M2 was a narrow-band noise.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
The first part of this paper presents several experiments on signal detection in temporally modulated noise, yielding a general approach toward the concept of comodulation masking release (CMR). Measurements were made on masked thresholds of both long- and short-duration, narrow-band signals presented in a 100% sinusoidally amplitude-modulated (SAM) noise masker (modulation frequency 32 Hz), as a function of masker bandwidth from 1/3 oct up to 13/3 octs, while the masker band was geometrically centered at signal frequency. With the short-duration signals placed in the valley of the masker, a substantial CMR (i.e., a decrease of masked threshold with increasing masker bandwidth) was found, whereas for the long-duration signals CMR was smaller. Furthermore, investigations were carried out to determine whether CMR changes when the bandwidth of the signals, consisting of bandpass impulse responses, is increased. The data indicate that substantial CMR remains even when all masker bands contain a signal component, thus minimizing across-channel differences. This finding is not in line with current models accounting for the CMR phenomenon. The second part of this paper concerns signal detection in spectrally shaped noise. Also investigated was whether release from masking occurs for the detection of a pure-tone signal at a valley or a peak of a simultaneously presented masking noise with a sinusoidally rippled power spectrum, when this masker was preceded and followed by a second noise (temporal flanking burst) with an identical spectral shape as the on-signal noise. Similar to CMR effects for temporal modulations, the data indicate that coshaping masking release (CSMR) occurs when the signal is placed in a valley of the spectral envelope of the masker, whereas no release from masking is found when the signal is placed at a peak of the spectral envelope of the masker. The implications of these experiments for measures of spectral and temporal resolution are discussed.  相似文献   

19.
A psychoacoustic method for measuring masking thresholds based on the application of single-type stimuli and maskers intended for revealing compressive nonlinearity of displacements of the cochlea basila membrane and evaluation of the frequency resolution of hearing in a narrow frequency range near the central frequency of the stimulus is considered. High-frequency pulses with an envelope in the form of a Gaussian function with a sinusoidal filling with the frequency band corresponding to the width of the critical hearing band have been used as stimuli (referred to as compact). Noises with a spike structure of the amplitude spectrum with a limited frequency band width served as maskers. With the central frequencies of stimuli and maskers being equal, a band noise with the central frequency corresponding with a spike of an indented spectrum was called an on(rip)-frequency masker, while that with the central frequency corresponding to a dip in an indented spectrum was called an off(rip)-frequency masker. The central frequencies and frequency bands of the stimuli and maskers were 4 kHz and 1000 Hz, respectively. The spike (dip) frequencies of an indented amplitude spectrum of a masker were 1000 Hz. In the case of successive and simultaneous masking, the dependences of the thresholds of off(rip)-frequency masking of compact stimuli on the masker level revealed compressive nonlinearity of basila membrane displacements. However, threshold on(rip)/off(rip)-frequency masking differences visualized it much better. The estimates of the frequency resolution obtained under conditions of simultaneous masking of compact stimuli during variations in the frequency of spikes of indented masker spectra of low and medium levels corresponded to the width of the critical hearing band measured using a classical method of tone masking by a pair of narrow-band noise maskers. Within the spike frequency range of 500–2000 Hz, the steepness of the dependence of off(rip)-masking of compact stimuli on the spike frequency decreased with an increase in masker levels that pointed to an effect of compressive properties of basila membrane displacements on this parameter.  相似文献   

20.
Masking sounds can be continuously present, gated simultaneously with the signal, or gated somewhat prior to the signal. This continuum of relative onset times was explored using waveforms of the sort commonly employed in studies of comodulation masking release (CMR). There was a 50-Hz masker band centered on the 1250-Hz tonal signal, and four 50-Hz flanker bands centered at 850, 1050, 1450, and 1650 Hz. In some conditions, all four flanker bands had the same temporal envelope, and the masker band either had that same envelope (correlated presentations) or a different envelope (uncorrelated presentations). In other conditions, all five bands had different temporal envelopes (all-uncorrelated presentations). The masker band and/or the four flanker bands were either gated nearly simultaneously with the signal (burst conditions) or were gated prior to the signal by a duration that was systematically varied (fringed conditions). The eight listeners could be partitioned into three groups on the basis of their response to these fringing manipulations. Two listeners (the large fringers) showed a gradual improvement in detectability with increasing fringe duration (called a temporal decline of masking), while three others (the small fringers) showed little improvement in detectability. For the remaining three subjects, there was evidence of a "learning" effect that changed them from large fringers to small fringers over a 10-week period of listening. When present, the temporal decline of masking was greater for the correlated than for the uncorrelated comodulation condition; as a consequence, the difference in detectability between them (the comodulation masking release or CMR) increased with fringe duration. By fringing the masker and flanker bands separately and in combination, it was revealed that the temporal declines of masking were primarily attributable to the fringing of the flanker bands. In contrast, large CMRs required long fringes on both the masker and flanker bands. The above results were obtained with 50-ms signals, but generally similar data were obtained with a signal duration of 240 ms. The difficulties raised for experimentalists and theorists by such long-term practice effects are discussed.  相似文献   