首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The precision of atomic mass measurements in a Penning trap is directly proportional to the charge state q of the ion and, hence, can be increased by using highly charged ions (HCI). For this reason, charge breeding with an electron beam ion trap (EBIT) is employed at TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) on-line facility in Vancouver, Canada. By bombarding the injected and trapped singly charged ions with an intense beam of electrons, the charge state of the ions is rapidly increased inside the EBIT. To be compatible with the on-line requirements of short-lived isotopes, very high electron beam current densities are needed. The TITAN EBIT includes a 6 Tesla superconducting magnet and is designed to have electron beam currents and energies of up to 5 A and 60 keV, respectively. Once operational at full capacity, most species can be bred into a He-like configuration within tens of ms. Subsequently, the HCI are extracted, pass a Wien filter to reduce isobaric contamination, are cooled, and injected into a precision Penning trap for mass measurement. We will present the first results and current status of the TITAN EBIT, which has recently been moved to TRIUMF after assembly and commissioning at the Max-Planck-Institute (MPI) for Nuclear Physics in Heidelberg, Germany.  相似文献   

2.
TITAN is an on-line facility dedicated to precision experiments with short-lived radioactive isotopes, in particular mass measurements. The achievable resolution on mass measurement, which depends on the excitation time, is limited by the half life of the radioactive ion. One way to bypass this is by increasing the charge state of the ion of interest. TITAN has the unique capability of charge-breeding radioactive ions using an electron-beam ion trap (EBIT) in combination with Penning trap mass spectrometry. However, the breeding process leads to an increase in energy spread, ??E, which in turn negatively influences the mass uncertainty. We report on the development of a cooler Penning trap which aims at reducing the energy spread of the highly charged ions prior to injection into the precision mass measurement trap. Electron and proton cooling will be tested as possible routes. Mass selective cooling techniques are also envisioned.  相似文献   

3.
The TITAN facility at TRIUMF-ISAC will use four ion traps with the primary goal of determining nuclear masses with high precision, particularly for short lived isotopes with lifetimes down to approximately 10 ms. The design value for the accuracy of the mass measurement is 1 ×10???8. The four main components in the facility are an RF cooler/buncher (RFCT) receiving the incoming ion beam, an electron beam ion trap (EBIT) to breed the ions to higher charge states, a cooler Penning trap (CPET) to cool the highly charged ions, and finally the measurement Penning trap (MPET) for the precision mass determination. Additional goals for this system are laser spectroscopy on ions extracted from the RFCT and beta spectroscopy in the EBIT (in Penning trap mode) on ions that are purified using selective buffer gas cooling in the CPET. The physics motivation for the mass measurements are manifold, from unitarity tests of the CKM matrix to nuclear structure very far from the valley of stability, nuclear astrophysics and the study of halo-nuclei. As a first measurement the mass of 11Li will be determined. With a lifetime of 8.7 ms and a demonstrated production rate of 4×104 ions/sec at ISAC the goal for this measurement at TITAN is a relative uncertainty of 5×10???8. This would check previous conflicting measurements and provide information for nuclear theory and models.  相似文献   

4.
The proposed Penning trap mass spectrometer, to be located at the TASCC facility of the Chalk River Laboratories, is described. The facility will be used for precise atomic mass determinations among both stable and unstable nuclides. The unstable nuclides would be produced in heavy ion reactions using the TASCC facility. The products from these reactions would be collected using an He-jet transport system loaded with NaCl aerosols. After transport to a background free area, the nuclides of interest would be laser desorbed and resonantly ionized. Subsequently, these ions would be accumulated in a Paul trap, cooled and injected into a precision Penning trap mass spectrometer for mass analysis.  相似文献   

5.
We present simulations of electron and proton cooling of highly charged ions in a Penning trap, including the potentially detrimental effects of radiative, dielectronic, and three-body recombination in electron cooling. We show a preliminary design for a cooler trap accommodating both electron and proton cooling, which will be a component of the TITAN ion-trap facility under construction at TRIUMF for precision mass measurements of short-lived radioactive nuclei.   相似文献   

6.
The introduction of Paul traps, in particular linear radio-frequency quadrupoles in the early 2000s, has revolutionized the use of ion traps for probing the properties of radioactive nuclides. It opened the path to trapping all available nuclides, independent of their chemical properties. We present an overview of direct mass measurements of short-lived nuclides using TITAN, a Penning trap mass spectrometer facility particularly suitable for precision measurements of ms-half-life nuclides.  相似文献   

7.
T. Eronen 《Pramana》2010,75(2):333-341
The JYFLTRAP Penning trap set-up at the University of Jyväskylä, Finland is a Penning trap facility that has provided high-precision atomic mass values for short-lived nuclides since 2003. Until now, masses of more than 250 short-lived nuclides have been measured. Since JYFLTRAP is coupled to the chemically insensitive IGISOL mass separator, any element can be accessed. So far, a huge mass surface extending from magnesium (Z = 12) to lead (Z = 82) has been covered.  相似文献   

8.
9.
Described in this paper is an experimental facility which measures atomic masses by using multiply charged ions from an electron beam ion source. The ions are injected into a Penning trap and the cyclotron frequencies measured. A precision of 2×10–9 has been reached using highly charged carbon, nitrogen, oxygen and neon.  相似文献   

10.
ISOLTRAP is a Penning trap mass spectrometer for high-precision mass measurements on short-lived nuclides installed at the on-line isotope separator ISOLDE at CERN. The masses of close to 300 radionuclides have been determined up to now. The applicability of Penning trap mass spectrometry to mass measurements of exotic nuclei has been extended considerably at ISOLTRAP by improving and developing this double Penning trap mass spectrometer over the past two decades. The accurate determination of nuclear binding energies far from stability includes nuclei that are produced at rates less than 100 ions/s and with half-lives well below 100ms. The mass-resolving power reaches 107 corresponding to 10keV for medium heavy nuclei and the uncertainty of the resulting mass values has been pushed down to below 10-8. The article describes technical developments achieved since 1996 and the present performance of ISOLTRAP.  相似文献   

11.
The low-energy beam and ion trap facility LEBIT at the NSCL at MSU has demonstrated that rare isotopes produced by fast-beam fragmentation can be slowed down and prepared such that precision experiments with low-energy beams are possible. For this purpose high-pressure gas-stopping is employed combined with advanced ion manipulation techniques. Penning trap mass measurements on short-lived rare isotopes have been performed with a 9.4 T Penning trap mass spectrometer. Examples include 66As, which has a half-live of only 96 ms, and the super-allowed Fermi-emitter 38Ca, for which a mass accuracy of 8 ppb (280 eV) has been achieved. The high accuracy of this new mass value makes 38Ca a new candidate for the test of the conserved vector current hypothesis.   相似文献   

12.
In the SMILETRAP facility externally produced highly charged ions are captured in a Penning trap and utilized for high precision measurements of atomic masses. Accuracy tests on a ppb level have been performed, using highly charged carbon, oxygen and neon ions. In all cases hydrogen ions served as a reference for the calibration and monitoring of the magnetic field in the trap. Deviations smaller than 3 ppb from the expected results were found in mass measurements of the16O and20Ne atomic masses. The proton atomic mass, determined from the reference measurements on hydrogen ions, is in good agreement with the accepted value [1]. A direct mass measurement on the86Kr-isotope, using trapped86Kr29+-ions is reported.  相似文献   

13.
The low-energy beam and ion trap facility LEBIT at NSCL/MSU is at present the only facility where precision experiments are performed with stopped rare isotope beams produced by fast-beam fragmentation. LEBIT combines high-pressure-gas stopping with advanced ion manipulation techniques to provide brilliant low-energy beams. So far these beams have mainly been used for mass measurements on short-lived rare isotopes with a 9.4T Penning trap mass spectrometer. Recent examples include 70m Br , located at the proton dripline, 32Si and the iron isotopes 63-65Fe . While the measurement of 32Si helps to solve a long-standing dispute over the validity of the isobaric multiplet mass equation (IMME) for the A = 32 , T = 2 multiplet, the mass measurements of 65m,g Fe marked the first time a nuclear isomeric state has been discovered by Penning trap mass spectrometry.  相似文献   

14.
15.
The LEBIT (Low Energy Beam and Ion Trap) facility is the only Penning trap mass spectrometry (PTMS) facility to utilize rare isotopes produced via fast-beam fragmentation. This technique allows access to practically all elements lighter than uranium, and in particular enables the production of isotopes that are not available or that are difficult to obtain at isotope separation on-line facilities. The preparation of the high-energy rare-isotope beam produced by projectile fragmentation for low-energy PTMS experiments is achieved by gas stopping to slow down and thermalize the fast-beam ions, along with an rf quadrupole cooler and buncher and rf quadrupole ion guides to deliver the beam to the Penning trap. During its first phase of operation LEBIT has been very successful, and new developments are now underway to access rare isotopes even farther from stability, which requires dealing with extremely short lifetimes and low production rates. These developments aim at increasing delivery efficiency, minimizing delivery and measurement time, and maximizing use of available beam time. They include an upgrade to the gas-stopping station, active magnetic field monitoring and stabilization by employing a miniature Penning trap as a magnetometer, the use of stored waveform inverse Fourier transform (SWIFT) to most effectively remove unwanted ions, and charge breeding.  相似文献   

16.
The investigation of simple atomic systems in extreme electromagnetic fields with highest precision demands intense beams of heavy and highly charged ions to be decelerated and cooled to extremely low energies for long-time observation. Resistive cooling, i.e., the electronic dissipation of energy of a stored ion cloud on an external impedance, seems to be a good candidate for in-trap cooling of highly charged ions and has been chosen for the upcoming HITRAP (Highly charged Ion TRAP) facility at GSI, Darmstadt. Nevertheless, resistive cooling of large ensembles of ions confined in a Penning trap has never been thoroughly studied until now and the understanding of this highly nonlinear phenomenon is far from complete. Through the use of systematic simulations we give a proof of the feasibility of resistive cooling of large numbers of highly charged ions as well as the interpretation of some specific features observed experimentally.  相似文献   

17.
A special problem in atomic physics research with highly charged ions is to prepare ions with a unique charge state inside of EBIS or EBIT devices. On the other hand, there are great losses resulting from the transport of the ions from the source to an external trap. Therefore we are setting up an EBIS/T with internal Penning trap. This new set-up will be able to study electron–ion interaction with well-defined initial and final charge states, distinguishing between single step successive ionisation and multiple step ionisation of charge states similar to the crossed beams method but for much higher charge states. Another feature of this system is to determine with high precision the ion charge state distribution in the EBIS/T by application of Fourier Transform Ion Cyclotron Resonance (FT-ICR). This method allows the on-line monitoring of the ion distribution and the evolution of the charge state population together with its dependence on the degree of space charge compensation of the electron beam in the EBIS/T. It will be possible to study ion dynamics in compensated space charge potentials. In case of high homogeneity of the magnetic field in the trap region, experiments may be considered to measure directly binding energies of highly-charged ions and other topics of high resolution mass spectroscopy. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

18.
Penning traps are powerful instruments for the precise and accurate mass determination of rare isotopes. At present, many Penning trap facilities installed at radioactive beam facilities provide key data for nuclear astrophysics, for the study of nuclear structure evolution far from stability, and the test of fundamental interactions. This article summarizes the present status and current limits in the field of high-precision Penning trap mass measurements on short-lived exotic ions.  相似文献   

19.
An ECR ion source for charge breeding of radioactive ions from the ISAC facility at TRIUMF has been set up at a test stand.It has been operated with different ion sources for the injection of singly charged ions and the efficiency,breeding time and emittance have been determined for several elements.A maximum efficiency of more than 6% for the breeding of Kr~(12 ) has been achieved so far.Additionally the charge exchange of Rb and Cs ions in the range of 10 to 23 with residual gas molecules in the transport beam lines has been investigated.The absolute values for the cross sections at 10—15 q keV agree with predictions extrapolated from lower charge states but the strong dependence on the ionization energy of the gas molecules could not be verified.  相似文献   

20.
High-precision mass measurements as performed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN are an important contribution to the investigation of nuclear structure. Precise nuclear masses with less than 0.1 ppm relative mass uncertainty allow stringent tests of mass models and formulae that are used to predict mass values of nuclides far from the valley of stability. Furthermore, an investigation of nuclear structure effects like shell or sub-shell closures, deformations, and halos is possible. In addition to a sophisticated experimental setup for precise mass measurements, a radioactive ion-beam facility that delivers a large variety of short-lived nuclides with sufficient yield is required. An overview of the results from the mass spectrometer ISOLTRAP is given and its limits and possibilities are described.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号